What was found
INSPECTION TYPE:C10, NLG CEILING UPPER SURFACE, CLIP AT BS 270.5, BL 0 CRACKED INSIDE ACCESS PANEL 113AZ. REMOVED, FABRICATED & INSTALLED NEW CLIP IA DWG 141N9910, REV 4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C10, NLG CEILING UPPER SURFACE, CLIP AT BS 270.5, BL 0 CRACKED INSIDE ACCESS PANEL 113AZ. REMOVED, FABRICATED & INSTALLED NEW CLIP IA DWG 141N9910, REV 4.