N465MC
Service difficulty reports · 223
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N465MC' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N465MC' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2014071400328Lens · missingEMERGENCY LIGHT LENS AT SEAT 47C IS MISSING. REPLACED EMER LIGHT LENS AT SEAT 47C IAW AMM 33-51-02.SDR UIEA2014071400332Lens · missingSEAT 4C END BAY COVER MISSING ESCAPE PATH LIGHTING LENS. FOUND LIGHT LENS FOR END BAY COVER FOR SEAT4C. UNDER SEAT INSTALLED AS REQUIRED IAW AMM 33-51-12.SDR UIEA2014051200175Warning System · false activationHYD QTY LOW 4 EICAS, QRH COMPLIED WITH. COMPLIED WITH FIM 32-61 TASK 808, HYDIM 4 GND TEST PASSED, NO FAULTS NOTED. PRESSURIZED HYDS, CYCLED FLIGHT CONTROLS & PERFORMED LEAK CHECK, NO LEAKS FOUND & OPERATIONS CHECKED GOOD.SDR UIEA2014042100152Switch · stuckDURING TRANSIT CHECK FOUND EMERGENCY LIGHT SWITCH STUCK IN ARMED POSITION ON OVERHEAD COCKPIT. R & R OVERHEAD EMERGENCY LIGHTING SWITCH IAW MM 33-50-00, POSITION CHECKED NORMAL.SDR UIEA2014040700141Connector · unsecureEMERGENCY ESCAPE PATH FLOOR LIGHTING ADJACENT TO SEAT 45H IS INOPERATIVE. SECURED CONNECTOR TO EMERGENCY PATH LIGHT AT SEAT 45H. OPERATIONS CHECKED GOOD IAW AM 33-50-00.SDR UIEA2014021500066Light · inoperativeEMERGENCY LIGHTING ON FLOOR AT R2 INOPERATIVE. R & R LIGHT ASSEMBLY IAW AMM 33-51-12. OPERATIONAL CHECKED OK IAW AMM 33-51-00.SDR UIEA2014021500065Battery · dischargedLEFT HAND FIRST CLASS EMERGENCY FLOOR LIGHTING INOPERATIVE. R & R LT HAND FIRST CLASS EMERGENCY FLOOR LIGHTING BATTERY ASSEMBLY IAW AMM 33-51-00. ALL OPERATIONAL CHECKS NORMAL.SDR UIEA2014021500064Wire · damagedUPPER DECK FLOOR EMERGENCY LIGHTING INOPERATIVE. REPAIRED WIRING IAW SWPM 20-30-12. OPERATIONAL CHECK OK IAW AMM 33-51-00.SDR UIEA2014021100052Warning System · false activationEICAS MESSAGE, DOOR FWD CGO, ON DEPARTURE PASSING 4000 FEET. PERFORMED DOOR OPERATIONAL CHECK IAW AMM 52-34-00-705-001, ALL OPERATIONS NORMAL. WARNING SYS CHECKED IAW AMM 52-71-00-715-005, NO DEFECTS NOTED.SDR UIEA2013121500602Light · damagedFLOOR TRACK EMERGENCY LIGHT DAMAGED AT DOOR 2R. REPAIRED EMERGENCY LIGHT AT 2R DOOR IAW SWPM 20-30-12. SYS OPERATIONS CHECKED GOOD.SDR UIEA2013102800542Cap · missingEMERGENCY LIGHTS FLOOR BY SEAT ROW 11ABC IS MISSING PARTS. INSTALLED EMERGENCY LIGHT END CAPS IAW AMM 25-27-05).SDR UIEA2013102800541Light · looseEMERGENCY FLOOR LIGHTS BY SEAT ROW 16AC IS TAPED DOWN. SECURED IAW AMM 33-51-12-422-021.SDR UIEA2013102800540Light · looseEMERGENCY; LIGHTS ON FLOOR BY SEAT ROW 12AC HAVE; TAPE HOLDING THEM DOWN. SECURED IAW AMM 33-51-12-422-021.SDR UIEA2013102800539Light · looseUPPER DECK BETWEEN LT AND RT WING DOORS, TWO EMERGENCY EXIT FLOOR LIGHTS ARE TAPED DOWN. SECURED IAW AMM 33-51-12-422-021.SDR UIEA2013100800514Actuator · failedEICAS CABIN ALTITUDE AUTO; EICAS OUTFLOW VALVE LIGHT. R & R OUTFLOW VALVE ICU, VALVE ACTUATOR, & DIODES.SDR UIEA2013071700386Frame · crackedWHILE ACCOMPLISHING EO:4453A295, REV 6, FOUND CRACK ON LOWER FRAME WEB BS 320, LBL 28. WEB REPLACED IAW EO:4453A295, PART 2 WHICH IS RELATED TO SB747-53A2784. NOTE: EO COMPLIES WITH AD 2012-22-02.SDR UIEA2013071700387Stringer · dentedDENT FOUND ON STRINGER 31R, BS 140-160. WHILE ACCOMPLISHING REPAIR IAW STA-SA EA 747-5300-28-A4695 ON NRC A000442. REPACED STRINGER IAW 51-40-02 AND DWG 65B07656.SDR UIEA2013071700388Stringer · dentedDENT FOUND ON STRINGER 34R, 140-160, WHILE ACCCOMPLISHING REPAIR IAW STA-SA 747-5300-28-A4695 ON NRC A000442. REPAIRED IAW EA 747-5300-28-A4724.SDR UIEA2013071700389Slide · no testL3 DOOR OVERWING SLIDE FAILED TO DEPLOY SUCCESSFULLY DURING AN INADVERTENT DEPLOYMENT. (OUTSIDE SERVICE) REPACKED L3 DOOR SLIDE IAW CMM 25-65-05, REV 11. L3 DOOR SLIDE REINSTALLED IAW AMM 25-65-16-404-022.SDR UIEA2013071700383Skin · dentedEXTERNAL FUSELAGE, DENT IN SKIN ON RT SIDE OF FUSELAGE BETWEEN BSTA 140-160 & STR 24R-26R. ACCOMPLISHED PERMANENT REPAIR BY INSTALLING REINFORCING DOUBLER AND TRIMMING OUT DENT IAW EA 5300-28-A4695, REV ORIG & IAW EO.SDR UIEA2013041000189Battery · dischargedFLASHLIGHT NEXT TO L2 DOOR INOPERATIVE. FOUND BATTERY INOPERATIVE AND CRADLE BROKEN. OPENSDR UIEA2013030200109Skin · damagedDURING LIGHTNING STRIKE INSPECTION, MX FOUND HOLE DAMAGE (APROX. 0.455 IN. DIA) ON THE FUSELAGE SKIN AND RING FRAME AT BS 134.75, S-45L. THE DAMAGE ON THE FUSELAGE SKIN WAS TRIMMED OUT AND REPAIR BASED ON SRM 53-00-01, REPAIR 1. THE SKIN (PN: 65B07658- 1001)SDR UIEA2013010400003Wire · damagedUPPER DECK L1 DOOR FWD EMERGENCY LIGHT INOPERATIVE. REPAIRED WIRE IAW SWPM 20-10-13. OPS CHECKED OK IAW AMM 33-51-00.SDR UIEA2013010400004Wire · damagedMAIN DECK ZONE A, EMERGENCY LIGHT INOPERATIVE. LT AND RT ROWS 12-16. REPAIRED WIRING IAW SPWM 20-10-13. EMERGENCY SYS LIGHT OPS CHECKED OK IAW AMM 33-51-00.SDR UIEA2013010400005Wire · damagedMAIN DECK ROWS 29-32 LT EMERGENCY LIGHT INOPERATIVE. REPAIRED LIGHT. EMERGENCY LIGHT WIRING IAW SWPM 20-10-13. EMERGENCY LIGHT SYS OPS CHECKED OK IAW AMM 33-51-00.SDR UIEA2013010400006Wire · damagedMAIN DECK ROW 45, RT EMERGENCY LIGHT INOPERATIVE. REPAIRED ROW 45 RT EMERGENCY LIGHT WIRE AND OPS CHECKED OK IAW SWPM 20-10-13 AND AMM 33-51-00.SDR UIEA2013010400007Lamp · inoperativeMAIN DECK R05 SLIDE LIGHT INOPERATIVE. LAMPED R5 SLIDE SLIGHT. OPS CHECKED NORMAL REF AMM 33-51-00.SDR UIEA2013010400008Lamp · inoperativeMAIN DECK L1 AFT DOOR SILL THRESHOLD EMERGENCY LIGHT INOPERATIVE. "L1854", LAMPED EMERGENCY LIGHT. OPS CHECKED NORMAL REF AMM 33-51-00.SDR UIEA2013010400011Wire · damagedRIGHT OVER WING FWD EMERGENCY LIGHT AFT BULB INOPERATIVE. REPAIRED RT OVERWING EMERGENCY LIGHT WIRE IAW SWPM 20-10-13. PERFORMED EMERGENCY LIGHT SYS OPS CHECK, OK IAW AMM 33-51-00.SDR UIEA2013010400009Lamp · inoperativeMAIN DECK L3 DOOR SILL THRESHOLD EMERGENCY LIGHT INOPERATIVE. LAMPED EMERGENCY LIGHT. OPS CHECKED NORMAL, REF AMM 33-51-00.SDR UIEA2013010400010Lamp · inoperativeMAIN DECK R-4 FWD DOOR SILL THRESHOLD EMERGENCY LIGHT INOPERATIVE. LAMPED LIGHT. OPS CHECKED NORMAL.SDR UIEA2012101400474Oven · inoperativeOVEN AT GALLEY G-02 STOP WORKING, FOUND EVIDENCE OF SMOKE AND CIRCUIT BREAKER POPPED. CIRCUIT BREAKER PULLED AND COLLARED.SDR UIEA2012091700435Light · inoperativeMAIN PASSENGER CABIN FLOOR EMERGENCY LIGHT IN L2 ENTRY DOOR AREA INOPERATIVE. R & R LIGHT AT L2 DOOR IAW MM 33-51-00. OPS CHECKED OK.SDR UIEA2012091700434Lamp · inoperativeMAIN DECK, ONE EMERGENCY LIGHT OUT AT R1 DOOR ENTRY AREA. RELAMPED LIGHT. OPS CHECKED OK IAW MM 33-51-00.SDR UIEA2012091700433Lamp · inoperativeMAIN DECK SEAT 55H EMERGENCY LIGHT INOPERATIVE, RELAMPED, OPS CHECKED OK IAW MM 33-51-00.SDR UIEA2012091700432Connector · unsecureMAIN DECK SEAT 23C EMERGENCY LIGHT INOPERATIVE. SECURED LOOSE CONNECTOR AT LIGHT ASSY. OPS CHECKED OK IAW MM 33-51-00.SDR UIEA2012091700431Connector · unsecureMAIN DECK 2 FLOOR PROXIMITY LIGHTS OUT AFTER 16H SEAT. SECURED LOOSE CONNECTION AT LIGHT ASSY ON FLOOR AT 16H. OPS CHECKED OK IAW MM 33-51-00.SDR UIEA2012091700430Connector · unsecureMAIN DECK BESIDE 14K SEAT, 2 FLOOR PROXIMITY LIGHTS INOPERATIVE. REINSTALLED LIGHT ASSY CONNECTOR AT SEAT 14K. OPS CHECKED OK IAW MM 33-51-00.SDR UIEA2012091700429Connector · unsecureMAIN DECK AT FIRST CLASS SECTION, BETWEEN LT SEAT ROWS 12 AND 16, ALL FLOOR PROXIMITY LIGHTS ARE OUT. RESECURED CONNECTOR AT SEAT 12A. OPS CHECKED OK IAW MM 33-51-00.SDR UIEA2012091700428Light · burned outONE EMERGENCY LIGHT OUT AT DOOR ENTRY AREA. NEED PN S417N509, LT ASSY. R & R LIGHT ASSY AT L1 DOOR IAW MM 33-51-00. OPS CHECKED OK.SDR UIEA2012091700427Connector · looseEMERGENCY LIGHTS OUT AFTER LT SEAT ROW 11 AT STAIR AREA. SECURED LOOSE CONNECTOR AT FLOOR LIGHT ASSY, OPS CHECKED OK IAW MM 33-51-00.SDR UIEA2012091700425Connector · looseUPPER DECK, 2 FLOOR PROXIMITY LIGHTS OUT BETWEEN LT SEAT ROW 6 AND 7 IN FRONT OF EMERGENCY EXIT DOOR. SECURED LOOSE CONNECTION AT FLOOR LIGHT ASSY, OPS CHECK OK IAW MM 33-51-00/ SOP.SDR UIEA2012062800291Panel · inoperativeWHILE ON GROUND, PRIOR TO DEPARTURE, CREW INADVERTENTLY DEPLOYED THE OXYGEN SYSTEM. MAINTENANCE SECURED ALL OXYGEN MASKS, RESET OXYGEN SYSTEM. UNABLE TO CLOSE SEATS 16DG & 60 DEG OXYGEN PANELS, PANELS SECURED AND SEATS BLOCKED ACCORDINGLY. OPENSDR UIEA2012050900207Light · damagedUPPER DECK EMERGENCY PATH LIGHTING AT LT EXIT DOOR DAMAGED.SDR UIEA2012050900206Light · missingEMERGENCY LIGHT MISSING FROM SEAT 17R. AISLE LOCATOR EMERGENCY LIGHT ASSY INSTALLED AT SEAT 17 RT; OPS CHECKED OK IAW AMM 33-51-12.SDR UIEA2012050900205Wire · brokenUPPER DECK E-PATH FLOOR LIGHTS AFT TO DOOR INOP. FOUND WIRES TO FLOOR LIGHT ASSY BROKEN BY SEAT 11A. R & R FLOOR AISLE LOCATOR 11A SEAT; OPS CHECKED OK IAW AMM 33-51-12.SDR UIEA2012050900204Connector · disconnected"A" ZONE FLOOR E-PATH RT AND LT SIDE INOPERATIVE. LT SIDE AFT A ZONE FOUND OPEN WIRE FROM CONNECTOR DM 2915 PIN 14; TRACED WIRE BACK FROM EMERGENCY LIGHT ASSY TO SIDEWALL. REMOVED SIDEWALL AND TRACED WIRE BEHIND SIDEWALL TO CONNECTOR D23661A. FOUND CONNECTOSDR UIEA2012050900203Light · brokenUPPER DECK LT DOOR AFT FLOOR LIGHT INOP. FOUND LIGHT ASSY DISCONNECTED AND BROKEN. INSTALLED U/D FLOOR LIGHT LT DOOR, OPS CHECKED OK IAW AMM 33-07-00)SDR UIEA2012050900202Connector · looseLEFT AFT LAV FLOOR EMERGENCY LIGHT INOPERATIVE. RESECURED LOOSE CONNECTOR IAW SWPM 20-60-06, PERFORMED OPS CHECK IAW MM 33-50-00; OPS CHECKED NORMAL.SDR UIEA2011112200693Light · failedFOUND RIGHT NR 4 OVERWING EMERGENCY LIGHT LENS BROKEN AND GROUND STUD LOOSE. LIGHT ASSY REPLACED AND CHECKED NORMAL IAW AMM 33-51-03.