N465UA
Service difficulty reports · 124
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N465UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N465UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2019082301411Fitting · corrodedL2 DOOR AFT CORNER FITTING CORRODED A3NB-05-3-6056 REFERENCE HAEC O LCQ NR 9296863 GENERATED BY V061629 REMOVED AND REPLACED L2 DOOR AFT CORNER FITTING IAW A320 SRM 51- 72-11-911-001 BY MECH V075620 MECH V061680 INSP BY LC-98SDR CALA2019081601362Floor Support · corrodedUNDER L2 DOOR UNDER CABIN FLOR STRUCTURE CORROSION ON STRINGER 2 5LT FR66+7 AND 66-3. REMOVED AND REPLACED STR25 LT REPAIR WITH NEW STR IAW A320 53-41 -13-300-004 .SDR CALA2019081091332Shear Plate · corrodedAFT CABIN LT SHEAR PLATE IS CORRODED. REMOVED AND REPLACED AFT CABIN L/H SHEAR PLATE AND APPLIED TOPCOAT TO ALL ATTACHING FASTENERS IAW SRM 51-72-11-911-01 AND SRM 51-42-11-801.SDR CALA2017071702279Battery · faultyEPSU EMERG BATT L AND EPSU EMERG BATT R MESSAGES GENERATED DURING EMERGENCY SYSTEM TEST REMOVED AND REPLACED EPSU BATTERIES AT LT AND RT OVER WING POSITIONS OP TEST PASS REF AMM 33-51-33.SDR CALA2016092795772Probe · malfunctionedNR 2 ENGINE OVERSPEED FAULT DURING ROLLOUT. REPLACED N1 SENSOR PROBE.SDR CALA2016092095756Strut · dischargedAIR RETURN DUE TO LANDING GEAR FAILING TO RETRACT. EMERGENCY DECLARED. SERVICED STRUT, SECURED LOOSE NLG PROXIMITY TARGET, REPLACED MLG SENSOR. SYSTEM GOOD, OK TO CONTINUESDR CALA2016090895725Strut · dischargedAIR TURNBACK DUE TO MLG SHOCK ABSORBER FAULT MESSAGE ON ECAM, NO RETRACTION. SWUNG NLG, NO FAULTS, GEAR SWING NORMAL. IAW TSM PERFORMED BOROSCOPE OF THE ALIGNMENT TANGS, FOUND ENGAGED AND NORMAL. FOUND NLG STRUT H DIMENSION APPROX ONE INCH LOW. SERVICED THE SDR CALA2016070195502Pump · leakingGREEN RESERVOIR LOW LEVEL TO NEAR ZERO DISPLAYED ON ECAM. FOUND NR 1 HYDRAULIC PUMP LEAKING, REPLACED PUMP, OPS GOODSDR CALA2014060991235Oxygen Mask · defectiveCAPTAIN'S OXYGEN HARNESS FAILS TO INFLATE, IS LEAKING. REPLACED CAPTAIN`S O2 MASK, OPERATIONS CHECKED OK.SDR CALA2014050690960Windshield · defectiveFIRST OFFICER'S WINDSHIELD HEAT IS INOPERATIVE. PLACED FIRST OFFICER'S WINDSHIELD R1 INOPERATIVE IAW MEL. CHECKED CAPTAIN'S WINDSHIELD HEAT OPERATIONS CHECKED NORMAL. REPLACED 2DG2 WHC-2, NR 2 WINDOW HEAT COMPUTER IAW AMM TASK 30-42-34-400-001-A & 000-00 1-ASDR CALA2013110892741Structure · dentedDENT IN LT LOWER AFT CARGO DOOR. DENT IS 3 IN. AFT EDGE 3 IN FROM BOTTOM, DENT IS 1IN X .5IN DEEP .004. VISUALLY INSPECTED NO CRACKS FOUND. OK TO CONTINUE.SDR CALA2013110892739Servo · malfunctionedSPOILER SERVO CNTL NR 1 RT, THERE HAVE BEEN REPEAT GRIPES & RESETS FOR FLT CONTROL SPOILER FAULTS AFTER ENG START. CFDS REPORTING FAULT "RT SPOILER 1 POS X-DUCER, 31CE2." AT NEXT MX OPPORTUNITY, REPLACE THE RT GRN NR 1 SPOILER SERVO-CONTROL, PCN 644-9561 IAW SDR CALA2013102192200Unknown · malfunctionedAPU WILL NOT PICKUP ELECTRICS WHEN COMING OFF EXTERNAL POWER.SDR CALA2013100891871Battery · dischargedEMERGENCY LIGHTS FAILED AT CIDS. REPLACED BATTERY AT EPSU 12WL, OPERATION TESTED OKAY.SDR CALA2013100791794Blade · damagedUPON ARRIVAL ACCOMPLISHED TAP TEST ON ENG NR 1 & FOUND THAT BLADE NR 21 FAILS TAP TEST READ OUT ARE 1867 DB PER SEC. REPLACED FAN BLADE IAW AMM. RAN BOTH ENGINES UP AS PER VIBRATION SURVEY INSTRUCTIONS. N 1 & N 2 VIBRATION OF ENG NR 1 ARE WITHIN LIMITS.SDR CALA2013082990840Skin · crackedNR 2 ENGINE RT THRUST REVERSER OUTER SKIN HAS 7-10 RIVETS PULLING THREW SKIN WITH A CRACK 5.75 INCHES LONG AT 1 O-CLOCK POSITION.SDR UALA2013070904777Warning Light · false activationNR 1 ENGINE FIRE DISCHARGE LIGHT ON. NO OTHER INDICATIONS. . VERIFIED BOTTLE PROPERLY CHARGED AND BOTTLE 2 DISCHARGE LIGHT IS WORKING PROPERLY.SDR UALA2013062604454Extinguisher · dischargedENGINE FIRE EXTINGUISHER DISCHARGED LIGHT OF "AGENT 1" ILLUMINATED WITHOUT FIRING BOTTLE 1. R & R NR 1 ENGINE FIRE EXTINGUISHING BOTTLE IAW MM.SDR UALA2013040802299Limiter · malfunctionedBCL 1 FAULT DISPLAYED ON UPPER ECAM SCREEN. - ELEC REMOVED AND REPLACED BCL1 PER AMM, OPS CHECK PASS PER AMM. NO FAULTS NOTED.SDR UALA2013040802298Contactor · faultyREFERENCE LOG 3 ON 5 APR, BCL 1 FAULT REPLACE BCL 1 AS PRECAUTIONARY. REMOVED AND REPLACED BCL NR 1 PER AMM 24-38-3-P401. PERFORMED TEST PER AMM 24-38-00-710-00 1-A. GOT FAULT IN 6PB1 CIRCUIT. LOG 3 REMAINS OPEN FOR T/S. REMOVED AND REPLACED NR 1 BATTERY SDR UALA2013030801390Computer · faultedCREW REPORTED ELAC 2 FAULT MESSAGES. REPLACED NR 2 ELAC IAW AMM 27-93-00-710-001A, TESTED OK.SDR UALA2013020800760Switch · malfunctionedMANUAL RUDDER TRIM KNOB HAS TO BE HELD IN DIRECTION OF DESIRED TRIM EXCESSIVE TIME FOR MOVEMENT. REPLACED RUDDER TRIM SWITCH IAW MM 22-62-11, OPS CHECKED NORMAL.SDR UALA2013020600721Unknown · vibrationNOSE LANDING GEAR VIBRATION DURING TAKEOFF. INSPECTED NLG AND WHEEL ASSYS, NO DEFECTS FOUND, LUBED GEAR. AIRCRAFT OK FOR SERVICESDR UALA2012121207194Angle · brokenLEFT WING FIXED L/E NR 5 SLAT TRACK CUTOUT OTBD REINFORCEMENT ANGLE IS BROKEN. MAJOR REPAIR ACCOMPLISHED: INSTALLED REPAIR ANGLE PER ECRA #5720-02364 AND REO-L01386 ON NR #39669. PERMANENT REPAIR WITH NO SUBSEQUENT INSPECTIONS REQUIRED.SDR UALA2012121207193Plate · damagedLEFT WING TANK ACCESS LANDING AT PANEL 540KB HAS ELONGATED HOLE. MAJOR REPAIR. BUSH-BRIDGING PLATE REPAIRED PER ECRA #5720-02345, REO-L01385 AND A-B RAS #70570268 -003-2012 ON NR #39591. PERMANENT REPAIR WITH NO SUBSEQUENT INSPECTIONS REQUIRED.AND SDR REPORSDR UALA2012121007135Sill · corrodedAFT CABIN R2 DOOR SILL CORROSION REQUIRES SRI INSPECTION. MAJOR REPAIR. MAINT TEXT: REPAIRED PER SRM 53-41-14 FIG 201.SDR UALA2012120707076Sill · corrodedAFT CABIN RT DOOR SILL HAS CORROSION. BLENDED AREA, FOUND TO BE OUT OF LIMITS PER SRM 53-41-14 FIG 101. FABRICATED AND INSTALLED REPAIR ANGLE PER SRM 53-41-14. SRI REQUIREMENTS FIRST INSP AT 92731 FC OR 208644 FH AFTER IMBODIMENT OF REPAIR, CURRENT PTC 1689SDR UALA2012120707077Sill · corrodedAFT CABIN LT DOOR SILL HAS CORROSION. BLENDED AREA, FOUND TO BE OUT OF LIMITS PER SRM. FABRICATED AND INSTALLED REPAIR ANGLE PER SRM 53-41-14. REPAIRED PER SRM 53-41-14 FIG 201. MAJOR REPAIR.SDR UALA2012102206044Bellows · damagedCAPTAINS SIDE STICK BOOT STARTING TO RIP. ITEM TEMP REPAIRED PER MT 27-031. RPLC'D CAPTAINS SIDE STICK BELLOWS.SDR UALA2012092105360Skin · damagedFOUND SKIN DAMAGE ON LEFT MAIN LANDING GEAR DOOR. DAMAGE MEASURES L=.5IN X W=.375IN X D=.048IN. PER SRM 52-81-14 FIGS 103-105-107. DAMAGE WITHIN ALLOWABLE LIMITS. PERFORMED TEMPORARY REPAIR PER SRM 51-77 -12 PARAGRAPH 2A. REPAIRED LEFT MAIN LANDING DOOR SKSDR UALA2012092105357Battery · dischargedCABIN EMERGENCY LIGHT TEST FAILED. (MSG: EPSU BATTERY LEFT). REPLACED BATTERY 11WL, 10WL AND 13WL PER AMM. RII CIDS TEST.SDR UALA2012091905301Seal · damagedCREW REPORTS SEAL BETWEEN LEFT INBOARD AND OUTBOARD FLAP LOWER SURFACE IS DAMAGED AT THE AFT AFT END. SEAT HAS SMALL TEAR AT AFT SIDE, NO LOOSE PIECES. NEEDS LEFT WING FLAP KINK SEAL (110-1856) ITEM #180 OF IPC 57-52-21 PG6A. REPLACED FLAP SEAL.SDR UALA2012080704256Liner · damagedRIGHT ENGINE HAS A HOLE IN THE ACCOUSTIC LINER AT THE 6 O'CLOCK POSITION. ATTRITION LINER DAMAGED AT THE 6 O'CLOCK POSITION, 1 INCH HOLE BY 3 INCH DELAMINATION. RT ENGINE HAS A THREE QUARTER INCH CHUNK OF HONEYCOMB MISSING AT THE 1730 POSIT NEXT TO FAN. OK SDR UALA2012051602769Warning Light · false activationRECEIVED MASTER WARNING BELL AFTER TAKEOFF WHEN GEAR LEVER RAISED. LOWERED GEAR HANDLE AND GOT TEXT, RAISED GEAR HANDLE AFTER 1 MIN. GEAR RAISED NORMAL. ALMOST LIKE SENSOR STUCK. VERIFIED SECURITY OF GEAR POSITION AND LOCK SENSORS. PERFORMED BITE TEST TO BOSDR UALA2012040402087Windshield · faultyECAM LEFT WINDSHIELD HEAT INOPERATIVE. WINDOW HEAT SENSOR & SPARE IS INOPERATIVE. INSTALLED CAPTAIN'S WINDSHIELD UP TO STEP E8 OF MM. ALSO COMPLETED STEP 'F' CHECK OF CLEARANCES. ICE DETECTION PROBE WIRES NOT CONNECTED. FINISHED INSTALLATION OF CAPTAIN'SSDR UALA2012040402095Sleeve · out of positionGAP BETWEEN ENGINE THRUST REVERSER SLEEVE AND FAN COWLING. NR 1 ENGINE APPROX 7 O'CLOCK POSITION. REPAIRED RUB STRIP. STILL MISMATCHED BY 070. OK PER MT 71-031 AND AMM 71-10-00-607 FOUND THAT .070 INCH UNDERFAIR (OUT OF WIND) TO BE ACCEPTABLE. THE REVERSSDR UALA2012030801515Line · unserviceableLIFE LINE PACK IS OPEN. REPLACED LIFE LINE PACK.SDR UALA2012022001021Floor Panel · damagedAFT CABIN FWD LAVATORY FLOOR IS SPONGY. NO EVIDENCE OF LIQUID LEAKING. REMOVED LAVATORY FROM STRUCTURE, ACCOMPLISHED FLOOR PAN REPLACEMENT.SDR UALA2012020900776Fire Bottle · dischargedLAV 'F' FIRE EXTINGUISHER SYSTEM - SMOKE. CREW COMMENTS: DISCHARGED. :MX FOUND THE FIRE BOTTLE IN THE RED BAND, LAV INOP IAW MEL PLACARD 2617M. ^06FEB OPB CQT- :ACCMP'D CHK OF LAV 'F' SMOKE DET SYSTEM. FOUND SMOKE DET SYS OPS NORMAL. LAV IS USEABLE PER MEL SDR UALA2011121206815Microphone · inoperativeFIRST OFFICER'S OXYGEN MASK MICROPHONE INOPERATIVE. REPLACED OBSERVER O2 MASK.SDR UALA2011110305963Oxygen Mask · defectiveCAPTAIN'S OXYGEN MASK MICROPHONE IS INOPERATIVE. REPLACED O2 BOX AND MASK. LEAK TESTED INSTALLATION.SDR UALA2011093005295Seal · missingFIRE EXTINGUISHER MISSING YELLOW SEAL IN AFT CABIN. SEAL REPLACED BY IAD MM.SDR UALA2011092205124Screw · looseCAPTAIN'S O2 WILL NOT TEST. FOUND SCREW ON SLIDER LOOSE. TIGHTENED SCREW. TESTED NORMAL.SDR UALA2011092105099Battery · dischargedEMERGENCY LIGHTING TEST FAILED TEST WITH MESSAGE EPSU BATTERY AFT LT. REPLACED EPSU BATTERY AT AFT LOCATION. EMER LIGHTS TEST PASSED.SDR UALA2011081004182Apu · malfunctionedBURNING SMELL IN AFT CABIN ON TAKEOFF AND LANDING. LAST 2 LEGS REPEAT WRITEUP. ACP HIGH POWER RUNS ISOLATING PACKS AND ENGINE BLEED SOURCES. TESTED LIGHTS AT ALL SETTINGS TESTED COFFEMAKERS, NO ABNORMAL SMELLS. FOUND OIL IN APU COMPARTMENT AND COMPRESSOR ISDR UALA2011071103455Filter · dirtyCABIN - FLT DECK ODOR BELOW 5K EXTREMELY BAD, DIRTY SOCK SMELL. FILTER CHECK - CLEANING NEEDED. REPLACED 2 EACH RECIRC FAN FILTERS IAW AMM.SDR UALA2011061002860Unknown · odorCREW REPORT: STRONG ODOR IN COCKPIT AND CABIN ON CLIMB AND DESCENT AROUND 7000FT. SAMC TEXT: OPERATE BOTH PACKS ON GND- NOTE ANY ODOR. REVIEWED HISTORY. RAN BOTH PACKS, NO ODOR NOTED.SDR UALA2011042101931Circuit Breaker · trippedMULTIPLE CB TRIPPED RELATED TO THE ELEC SYSTEM. AFTER ACCOMPLISHMENT OF COA406283, ACFT EXPERIENCED CB TRIP, DISCOVERED CB'S AB10 (TR1 SUPPLY), AD11 (101XP SUPPLY), AD12 (L WING PUMP STBY SUPPLY), BC1 (TR2), & BG (202PP SUPPLY) TRIPPED. RESET BREAKERS & MANUSDR UALA2011030401076Rod End · wornLT ELEVATOR OTBD SERVO FAILS EXCESSIVE PLAY CHECK PER MM. REPLACED OTBD SERVO EYE-END. COMPLETED INSTALLATION UP TO PARAGRAPH A(6) OF MM.SDR UALA2011022400925Slide · out of toleranceRIGHT OVERWING SLIDE PAINTED OVER ENCLOSURE DOOR BALL LOCK PINS. REPLACED RT OVER WING SLIDE IAW MM.
Back to N465UA