N470UP
Service difficulty reports · 152
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N470UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N470UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA3579877Floor Panel · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 232XQF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3579876Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 232XCF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579875Floor Panel · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 232XAF IS DAMAGED. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3579874Floor Panel · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 221XCF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13579787Floorboard · damagedINSPECTION TYPE:C-8 MAIN CABIN FLOORBOARD 211XAF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO, B757-5320-9692-HSDR IPXA3579761Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 251XMF IS DAMAGED. FABRICATE NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579760Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 252XTF IS DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579759Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 251XNF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579758Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 251XPF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579757Floor Panel · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 251XQF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579755Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 252XLF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579754Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 252XJF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579752Floorboard · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD 251XBF IS DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579751Floorboard · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD 251-XFF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579750Floorboard · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD 251XEF IS DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579749Floorboard · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD 252XFF DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3580065Floorbeam · corrodedC-8 INSPECTION, MAIN CABIN FLOORBEAM TEE CORRODED AT BS 1100, LBL24-36. REPAIRED CORRODED TEE IAW EO B757-5310-51942-A AND REO-G16556, REV A.SDR IPXA3580064Floorbeam · corrodedC-8 INSPECTION, MAIN CABIN UNDER FLOORBEAM TEE IS CORRODED AT BS 1100, LBL 0 TO LBL 24. REPAIRED CORRODED TEE IAW EO B757-5310-51920-A AND REO-G16556, REV A.SDR IPXA3580048Frame · damagedC8 INSPECTION, BS 660 AT STRINGER 16L HAS A SCREW STRIKE. INSTALLED FRAME REPAIR IAW REO G16501, REV B.SDR IPXA2013083080016Frame · damagedC8 INSPECTION, BS 440 AT STRINGER 16R HAS SCREW STRIKE. DRILLED HOLE AT DAMAGE LOCATION AND INSTALLED RIVETS IAW EO B757-5310-51920-A & REO -G16538, REV IR.SDR IPXA3579970Attach Fitting · corrodedINSPECTION C8, MAIN CABIN ATTACH FRAME AT STA 1060, LBL 20 HAS CORROSION. REPLACE TEE, PN 144N5005-5.SDR IPXA3579957Support · corrodedINSPECTION C8, MAIN CABIN UNDER FLOORBOARD, ATTACH FRAME ON SEAT TRACK CORRODED AT STA 1050 TO STA 1100. REPLACED TRACK SUPPORT, PN 144N8031.SDR IPXA3579900Frame · corrodedINSPECTION TYPE:C8, MAIN CABIN FLOOR, ONE ATTACH FRAME CORRODED NR 1060, LBL 24-26. REPLACE TEE.SDR IPXA3579896Frame · corrodedINSPECTION TYPE:C8, MAIN CABIN CENTER SECTION UPPER ATTACH FRAME AT BS 1070, RBL 12 IS CORRODED. REPLACE TEE.SDR IPXA13579784Floor Panel · corrodedINSPECTION TYPE:C8, MAIN CABIN, UNDER FLOOR PANEL, AFT DECK PLATE HAS CORROSION BS 1680, RBL5. REPAIRED AFT DECK PLATE IAW SRM 53-60-51-2R-8.SDR IPXA13579783Deck Plate · corrodedINSPECTION TYPE: C8, MAIN CABIN PRESSURE DECK PLATE IS CORRODED AT NUTPLATE HOLES AT BS 1681, RBL 31-39. REMOVED CORROSION AND CHECKED LIMITS IAW SRM 53-60-51-1A-1, FOUND TO BE WITHIN LIMITS APPLIED PROTECTIVE TREATMENT IAW SRM 51-20-01.SDR IPXA3580073Angle · corrodedINSPECTION TYPE:C8, MAIN CABIN BS 1610-1630, RBL 60 CREASE BEAM RETAINER ANGLE CORRODED IN TWO PLACES. R & R RETAINER ANGLE IAW PRODUCTION DWG 146N5353-70-2.SDR IPXA3579857Floorbeam · corrodedINSPECTION TYPE:C-8, MAIN CABIN BS 1200 LBL 45.5 TO RBL 45.5 FLOORBEAM UPPER FLANGE, UPPER SURFACE CORRODED. FABRICATED NEW REPAIR IAW SRM 53-00-51-2R-6.SDR IPXA1569680Strap · corrodedINSPECTION TYPE:C-1, STRAP BS 1700 RBL 9.2, CORRODED OUT OF LIMITS. REPLACED WITH NEW.SDR IPXA1569627Tie Down · corrodedINSPECTION TYPE:CK BULK CARGO COMPT TIEDOWN FITTING STA1480 STR 20R CORRODED BEYOND LIMITS. R & R IAW SRM-51-40-02SDR IPXA1569626Tie Down · corrodedINSPECTION TYPE:CK, BULK CARGO COMPT TIEDOWN FITTING AT STA 1500 STR 20R CORRODED BEYOND L IMITS. REPLACED IAW B757-SRM-51-40-02.SDR IPXA1569625Panel · corrodedINSPECTION TYPE:CK, AFT PIT RT SIDE PANEL AT BS 1470 CORRODED BEYOND LIMITS. REPLACED SIDE PANEL IAW B757-SRM-51-40-02.SDR IPXA10558075Floorboard · dentedINSPECTION TYPE:C2 FLOORBOARD PANEL HAS SEVERAL DENTS BS 900-1020 RBL 25-45 WL208. FABRICATED NEW FLOOR PANEL FROM STOCK MATERIAL A402H IAW EO NR B757-5320-9692-F.SDR IPXA09557776Floorbeam · corrodedINSPECTION TYPE:C2 BS 1200 FLOORBEAM HAS 1 AREA OUT OF LIMITS PER SRM. REPAIR IAW ATS ER 09-5034, B757-5310-35333-A.SDR IPXA09557724Support · corrodedINSPECTION TYPE:C2 BS 640 TO 769 LT FLOOR TO SIDEWALL IS CORRODED. REMOVED CORROSION AND REPAIRED AREA THAT WAS FOUND TO BE OUT OF LIMITS AT BS 714, LBL 21 IAW EO NR B757-5310-32833, SRM 51-70-13-0G AND SRM 51-40-02-0G.SDR IPXA09557726Sill · corrodedINSPECTION TYPE:C2 BS 560 TO 620 FWD CARGO DOOR LOWER SILL IS CORRODED. REMOVED AND REPLACED FWD CARGO DOOR LOWER DOOR SEAL RETAINER SUPPORT IAW SRM 51-40-05-0G AND SRM 51-40-02-0G.SDR IPXA09557657Channel · corrodedINSPECTION TYPE:C2 BS 630 LBL 19 LT FLOOR TO SIDEWALL IS CORRODED. BLENDED AREA PER SRM 53-00-53-1AI DETAIL V FOUND TO BE WITHIN LIMITS PER SRM 53-00-53. ALODINED AND REFINISHED PER SRM 51-20-01-0G IAW IPXA EOB757-5310-32833A.SDR IPXA09557778Floorbeam · corrodedINSPECTION TYPE:C2 BS 1100 FLOORBEAM HAS CORROSION FROM LBL65 TO RBL 65. REPAIR IAW ATS ER 09-5051.SDR IPXA09557777Floorbeam · corrodedINSPECTION TYPE:C2 MC FLOORBEAM 1200 HAS NUMEROUS AREAS OF CORROSION FROM LBL 65 TO RBL 65 AROUND FLOOR PANEL MOUNT SCREW HOLES. REPAIRED IAW ATS ER 09-5034 B757-5310-35333-A.SDR IPXA09557741Skin · delaminatedINSPECTION TYPE:C2 WHILE WORKING REPAIR ASSESSMENT FOUND PREVIOUS REPAIR (SEG NR 470-W3-02) ON NR 3 SLAT T/E WEDGE UPPER SURFACE AT OSS 467 TO OSS 475.5 DISBONDED AT UPPER EDGE. REPAIRED PER SRM 51-70-10.SDR IPXA09557725Floorbeam · corrodedINSPECTION TYPE:C2 MAIN CABIN FLOOR PANEL SUPPORT IS CORRODED STA 1055 RBL 29. REMOVED AND REPLACED FLOOR PANEL SUPPORT IAW SRM 51-10-02-0G, SRM 51-40-02-0G AND SRM 51-40-05-0G.SDR IPXA09557709Support · corrodedINSPECTION TYPE:C2 BS 840 TO 760 RIGHT FLOOR TO SIDEWALL IS CORRODED REPAIRED OUT OF LIMITS AREA OF FLOOR TO SIDEWALL IAW SRM 51-70-13-0G SRM 51-20-01-0G AND EO NR B757-5310-32833.SDR IPXA09557622Floor Support · corrodedINSPECTION TYPE:C2 FLOOR SUPPORT IS CORRODED, BS 1055, LBL35 WL 208. REMOVED, FABRICATED, AND INSTALLED FLOOR SUPPORT PER SRM 51-40-02-0G AND DWG 144N5005-3.SDR IPXA09557806Mount Bracket · crackedINSPECTION TYPE:C2 48 SECTION, APU FIRE MOUNT BRACKET IS CRACKED AT THE FWD O/B CORNER. REMOVED FABRICATED AND INSTALLED REPLACEMENT MOUNT.SDR IPXA09557774Structure · corrodedINSPECTION TYPE:C2 TAIL COMPARTMENT, APU INLET DOOR FWD MOUNT STRUCTURE HAS CORROSION. REPAIRED PER ATS ENGINEERING REPAIR NR 09-5025 DATED 12OCT09.SDR IPXA09557763Floorboard · dentedINSPECTION TYPE:C2 MAIN CARGO COMPARTMENT FLOORBOARD IS DENTED AT BS 971, LBL36. FABRICATED NEW FLOORBOARD PER SRM ADDENDUM EO NR B757-5320-9692-G.SDR IPXA09557727Floorboard · dentedINSPECTION TYPE:C2 MAIN CARGO COMPARTMENT FLOORBOARD IS DENTED AT BS 1240 RBL 55. MADE A REPLACEMENT FLOOR PANEL PER EO NR B757-5320-9692-G.SDR IPXA09557674Floorboard · dentedINSPECTION TYPE:C2 MAIN CARGO COMPARTMENT FLOORBOARD IS DENTED AT BS 1419 RBL15. FLOOR BOARD WAS REPLACED PER EO 757-5320-9692-G.SDR UPS08553418Seal · brokenINSPECTION TYPE:N/A FWD EMERGENCY DESCENT DEVICE HAS ONE SEAL BROKEN. REMOVED AND REPLACED DESCENT DEVICE REF MM 25-61-02-2.SDR UPS08553008Engine · vibrationLT ENG VIBRATION IN AMBER BAND. VIBRATION NORMAL AT IDLE. OCCURRED AT THRUST REDUCTION AT TOP OF CLIMB. COMPLIED WITH STEPS 1-4 OF FIM 71-05-00 FIG 108 WITH NO DEFECTS NOTED. COMPLETED ALL REMAINING STEPS OF FIM 71-05-00 FIG 108. VIBRATION SURVEY C/W ALL WITH
Back to N470UP