INSPECTION TYPE:C2 BS 630 LBL 19 LT FLOOR TO SIDEWALL IS CORRODED. BLENDED AREA PER SRM 53-00-53-1AI DETAIL V FOUND TO BE WITHIN LIMITS PER SRM 53-00-53. ALODINED AND REFINISHED PER SRM 51-20-01-0G IAW IPXA EOB757-5310-32833A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2 BS 630 LBL 19 LT FLOOR TO SIDEWALL IS CORRODED. BLENDED AREA PER SRM 53-00-53-1AI DETAIL V FOUND TO BE WITHIN LIMITS PER SRM 53-00-53. ALODINED AND REFINISHED PER SRM 51-20-01-0G IAW IPXA EOB757-5310-32833A.