N472UP
Service difficulty reports · 112
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N472UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N472UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2014012201531Floorboard · damagedINSPECTION C-8, MAIN CABIN FLOORBOARD 252XTF HAS EDGE DAMAGE. FABRICATED FLOORBOARD IAW SREO B757-5320-6962-H.SDR IPXA2014012201529Floorboard · damagedINSPECTION C-8, MAIN CABIN FLOORBOARD 251XRF HAS EDGE DAMAGE. FABRICATED FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014012201528Floorboard · damagedINSPECTION C-8, MAIN CABIN FLOORBOARD 251XQF HAS EDGE DAMAGE. FABRICATED FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014011501353Frame · dentedC8 INSPECTION, AFT CARGO BAY FRAME DENTED ON RADIUS AT BS 1580, S26L. REPAIRED FRAME IAW SRM 53-00-07-2R-5.SDR IPXA2014011301303Floorboard · damagedC-8 INSPECTION, MAIN CABIN FLOORBOARD 251XCF IS DAMAGED. FABRICATED NEW FLOORBOARD.SDR IPXA2014011301301Floorboard · damagedC-8 INSPECTION, MAIN CABIN FLOORBOARD 251XHF IS DAMAGED. FABRICATED NEW FLOORBOARD.SDR IPXA2014011301300Floorboard · damagedC-8 INSPECTION, MAIN CABIN FLOORBOARD 251XGF IS DAMAGED. FABRICATED NEW FLOORBOARD.SDR IPXA2014011301298Floorboard · damagedC-8 INSPECTION, MAIN CABIN FLOORBOARD 242XMF IS DAMAGED. FABRICATED NEW FLOORBOARD.SDR IPXA2014011301295Floorboard · damagedC-8 INSPECTION, MAIN CABIN FLOORBOARD 242XUF IS DAMAGED. FABRICATED NEW FLOORBOARD.SDR IPXA2014011301288Floorboard · damagedC8 INSPECTION, MAIN CABIN FLOORBOARD 232XSF90 IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014011301287Floorboard · damagedC8 INSPECTION, MAIN CABIN FLOORBOARD 232XSF89 DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014011301286Floorboard · damagedC8 INSPECTION, MAIN CABIN FLOORBOARD 231XCF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SERO B757-5320-9692-H.SDR IPXA2014011301284Floorboard · damagedC8 INSPECTION, MAIN CABIN FLOORBOARD 231XNF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014011301283Floorboard · damagedC8 INSPECTION, MAIN CABIN FLOORBOARD 231XCF IS DAMAGED. FABRICATED FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014011301282Floorboard · damagedC8 INSPECTION, MAIN CABIN FLOORBOARD 231XAF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014011301281Floorboard · damagedC8 INSPECTION, MAIN CABIN FLOORBOARD 231XWF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014011301280Floorboard · damagedC-8 INSPECTION, MAIN CABIN FLOORBOARD 231XEF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014011301279Floorboard · damagedC-8 INSPECTION, MAIN CABIN FLOORBOARD 231XMF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014010801232Seat Track · corrodedC8 INSPECTION, MAIN CABIN SEAT TRACK CORRODED BS 480, LBL 48. REMOVED CORROSION IAW SRM 53-00-52-1A-1.SDR IPXA201401081231Pressure Deck · corrodedC8 INSPECTION, PRESSURE DECK FLOOR CORRODED BS 518, LBL 48. REMOVED CORROSION IAW SRM 53-30-15-1A-3.SDR IPXA2014010801230Pressure Deck · corrodedC8 INSPECTION, PRESSURE DECK FLOOR CORRODED BS 500, LBL 60. REMOVED CORROSION IAW SRM 53-30-15-1A-3.SDR IPXA2014010801229Pressure Deck · corrodedC8 INSPECTION, PRESSURE DECK FLOOR CORRODED BS 570, LBL 60. REMOVED CORROSION IAW SRM 53-30-15-1A-3.SDR IPXA2014010801228Pressure Deck · corrodedC8 INSPECTION, PRESSURE DECK FLOOR CORRODED BS 580 TO 615, LBL 48. REMOVED CORROSION IAW SRM 53-30-15-1A-3.SDR IPXA2014011301290Frame · dentedC8 INSPECTION, FORWARD CARGO BAY FRAME DENTED BS 820, STR25R. REPAIRED FRAME IAW SRM 53-00-07-2R-5, DETAIL III.SDR IPXA2014011001263Frame · dentedC-8 INSPECTION, FORWARD CARGO BAY FRAME DENTED BS 820, S25L. REPAIRED FRAME IAW SRM 53-00-07-2R-5, DETAIL III.SDR IPXA2013121101035Window · out of adjustDURING TROUBLESHOOTING R2 WINDOW SEAL, FOUND WINDOW EXTREMELY HARD TO OPEN & CLOSE WITH CRANK HANDLE. PERFORMED ADJUSTMENT TEST OF R2 WINDOW OPS NORMAL.SDR IPXA2575273Lamp · inoperativeINSPECTION TYPE: PS, UNARMED INDICATOR LIGHT FOR EMERGENCY EXIT LIGHT ON CONTROL PANEL BURNED OUT. RELAMPED IAW AMM 33-16-02-962, OPS CHECKED GOOD.SDR IPXA2571193Skin · damagedINSPECTION TYPE:C-CK, LT ELEVATOR UPPER SURFACE HAS DAMAGE JUST INBD OF STATIC WICS. REPAIRED LT ELEVATOR UPPER SURFACE JUST INBD OF STATIC WICS IAW SRM 55-20-01-2R-1 AND SRM 51-70-04-0G.SDR IPXA2571165Frame · dentedINSPECTION TYPE:C-CK, AFT CARGO COMPARTMENT FRAME AT BS 1260 STR 26R IS DENTED. FABRICATED AND INSTALLED REINFORCING REPAIR IAW EA 120010 AND EO B757- 5310-45584-A FROM 7075 T6 .080" MATERIAL.SDR IPXA12570973Closeout Panel · corrodedINSPECTION TYPE:C-CK, FLIGHT DECK UPPER FLOOR CLOSEOUT PANEL CORRODED FROM FLOOR TO 9G WALL AT BS 330. FABRICATED NEW CLOSE OUT PANEL IAW DWG NR141N6007.SDR IPXA12570972Floor Panel · dentedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 231 XAF DENTED AND PUNCTURED. FABRICATED MAIN CARGO COMPARTMENT FLOOR PANEL 231 XAF IAW EO B757-5320-9692-H.SDR IPXA12570971Floor Panel · puncturedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 221XCF CRUSHED AND PUNCTURED. FABRICATED MAIN CARGO COMPARTMENT FLOOR PANEL 221 XCF IAW EO B757-5320-9692-H.SDR IPXA12570938Floorboard · damagedINSPECTION TYPE:CK, UPPER FLOORBOARD FLIGHT DECK PANEL DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692.SDR IPXA12570937Floorboard · damagedINSPECTION TYPE:CK, UPPER FLOORBOARD FLIGHT DECK PANEL DAMAGED. FABRICATE NEW FLOORBOARD IAW EO B757-5320-9692.SDR IPXA2570886Floor Panel · puncturedINSPECTION TYPE:C-CK, AFT BULKHEAD FLOOR PANEL RT SIDE-UPPER SIDE PUNCTURED (252XUF). FABRICATED NEW AFT BULKHEAD FLOOR PANEL (252XUF) IAW EO B757-5320-9692-H.SDR IPXA10558147Door Frame · damagedINSPECTION TYPE:C2, MAIN CARGO HAS SCREW SCARS ON TOP OF LOWER FRAME ASSY AT STA-486. REMOVED DAMAGED FRAME, INSTALLED NEW IAW SLM 52-30-02-1A, 51-40-02- OG.SDR IPXA10558132Skin · chafedINSPECTION TYPE: C2, NR 9 SLAT LWR SURFACE CHAFED THROUGH. REPAIR CHAFES IAW SRM 51-70-10.SDR IPXA10558131Skin · chafedINSPECTION TYPE: C2, NR 9 SLAT LWR SURFACE T/E CHAFED THROUGH. REPAIR CHAFES IAW SRM 51-70-10-2R.SDR IPXA10558130Skin · chafedINSPECTION TYPE: C2, NR 9 SLAT LWR SURFACE CHAFED THROUGH. REPAIRED CHAFE IAW SRM 51-70-10.SDR IPXA10558137Support · crackedINSPECTION TYPE:C2, BS 1530 TO 1640 LBL 21 FLOOR TO SIDEWALL IS CORRODED AND CRACKED. CRACK FOUND AT BS 1598-25 LBL 16 FOUND OUT OF LIMITS IAW SRM 53-00-53-1A1, REPAIRED IAW SRM 51-70-11-0G, FIG 1. (ALL CORRODED AREAS BLENDED AND FOUND IN LIMITS BS 1530 TO 1SDR IPXA10558114Support · crackedINSPECTION TYPE:C2 BS 1530 TO 1640 LBL 21 FLOOR TO SIDEWALL IS CORRODED AND CRACKED. CRACK FOUND AT BS 1598.25 LBL 16 FOUND OUT OF LIMITS IAW SRM 53-00-53-1A1, REPAIRED IAW SRM 51-70-11-0G FIG 1. (ALL CORRODED AREAS BLENDED AND FOUND IN LIMITS BS 1530 TO 1640SDR IPXA10558078Support · corrodedINSP TYPE:C2-BS 1440 TO 1530 RBL 21 FLOOR TO SIDEWALL IS CORRODED & PUNCTURED. CORROSION BLENDED IN LIMITS IAW E.O B757-5310-328 33A REPAIRED PUNCTURED IAW SRM 51-40-06, 54-40-05-06, 51-10-02-06.SDR IPXA10558156Door Frame · corrodedINSPECTION TYPE:C2, MAIN CARGO DOOR, DOOR FRAME BS530 HAS 3EA SCREW STARTS ON FRAME BETWEEN WL 213-218. (MARKED) REPAIRED DOOR FRAME IAW ER 10-1028 DATED 1-14-10.SDR IPXA10558218Panel · damagedPANEL 443 ER OUTER SURFACE HAS MECHANICAL DAMAGE ADJACENT TO A FASTENER HOLE (MARKED AND AREAS OF BARE METAL. REMOVED THE MECHANICL DAMAGE. ACCOMPLISHED HFEC INSP OF REWORKED AREA. COUNTERSINK AROUND THE AFFECTED FASTENER HOLE; ALODINED AND APPLIED (1) COAT OSDR IPXA10558155Floorbeam · corrodedINSPECTION TYPE:C2, CORROSION ON UPPER SURFACE OF BS 1100 FLOORBEAM WL 208 LBL36 TO RBL 55 (MARKED). REPAIRED FLOORBEAM IAW ATS ER NR 09-6023 DATED 1-13-10.SDR IPXA10558148Floorbeam · corrodedINSPECTION TYPE: C2, CORROSION FOUND ON LWR SURFACE OF THE UPPER CHORD AT LBL 4.7" BS 1200 OUT OF LIMITS. REPAIRED FLOORBEAM AT BS 1200, IAW REV ATS ER NR 10-1000, AND EO NR B757-5310-36265-A.SDR IPXA10558079Floor Panel · damagedINSPECTION TYPE:C2 MCB FLOOR PANEL BS 1055 TO BS 1100 LBL 45-60 HAS DAMAGED INSERT AND DAMAGE ON LWR SURFACE. (MARKED) REPLACED FLOOR PANEL IAW EO B757-5320-9692-F.SDR IPXA10558045Floor Panel · damagedINSPECTION TYPE:C2 MCB FLOOR PANEL BS 900-1020 RBL 45-60 DAMAGED. REPAIRED IAW EO B757-5320-9692.SDR IPXA10558044Floor Panel · damagedINSPECTION TYPE:C2 MCB FLOOR PNL BS 1020-1055 LBL 45-60 DAMAGED. FABRICATED NEW IAW EO B757-5320-9692.SDR IPXA10558043Floor Panel · damagedINSPECTION TYPE:C2 MCB FLOOR PANEL BS1016-1055 LBL 25-45 DAMAGED. FABRICATED NEW IAW EO B757-5320-9692
Back to N472UP