What was found
INSP TYPE:C2-BS 1440 TO 1530 RBL 21 FLOOR TO SIDEWALL IS CORRODED & PUNCTURED. CORROSION BLENDED IN LIMITS IAW E.O B757-5310-328 33A REPAIRED PUNCTURED IAW SRM 51-40-06, 54-40-05-06, 51-10-02-06.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSP TYPE:C2-BS 1440 TO 1530 RBL 21 FLOOR TO SIDEWALL IS CORRODED & PUNCTURED. CORROSION BLENDED IN LIMITS IAW E.O B757-5310-328 33A REPAIRED PUNCTURED IAW SRM 51-40-06, 54-40-05-06, 51-10-02-06.