N473UP
Service difficulty reports · 105
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N473UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N473UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2025041047242Skin · corrodedRH PYLON INSIDE PANEL 443CR FWD LOWER CORNER HAS CORROSION. DOT 28-45. ACOOMPLISHED STEP 23 INSTALLED REPAIR DOUBLER I.A.W EA# 757-5450-27-A3854 PRELIMINARY 3 AND SRM 51-40-02-OG. REVIEWEDSDR IPXA2025031647242Skin · corrodedRH PYLON INSIDE PANEL 443CR FWD LOWER CORNER HAS CORROSION. DOT 28-45 NOT ABLE TO REMOVE NOTED MEASUREMENTS. ALL MEASUREMENTS WERE ADDED TO CPCP AND SDR TASKS.SDR IPXA2025040845454Floor Panel · damagedMCD, ABOVE CENTER BOX, FLOOR PANEL241XBF HAS SEVERAL DENTS/PUCTURES (APPROX 45 EA), LOWER/UPPER SURFACE AND EDGE DAMAGED. DOT 103-35. FABRICATED MCD FLOOR PANEL 241XBF IAW UPS SREO: B757-9692-REQ 001.SDR IPXA2025040745296Floor Panel · damagedCOMP, MCD, ABOVE CENTER BOX, FLOOR PANEL241XDF, LOWER SURFACE HAS DENTS/PUCTURES (APPROX 2 EA) AND EDGE DAMAGED. DOT 103-29. FABRICATED MCD FLOOR PANEL 241XDF, IAW UPS SREO: B757-9692-REQ 001 REVIEWEDSDR IPXA2025040745550Floor Panel · damagedFAULT - Z200, COMP, MCD, ABOVE CENTER BOX, FLOOR PANEL241XAF HAS UPPER SURFACE AND EDGE DAMAGED. DOT 103-38. FABRICATED MCD FLOOR PANEL 241XAF, IAW UPS SREO: B757-9692-REQ 001 REVIEWEDSDR IPXA2025040744836Floor Panel · damagedMCD, ABOVE CENTER BOX, FLOOR PANEL242XJF HAS LOWER SURFACE AND EDGE DAMAGED. DOT 103-10. FABRICATED MCD FLOOR PANEL 242XJF, IAW UPS SREO: B757-9692-REQ 001 REVIEWEDSDR IPXA2025040745419Floor Panel · damagedFAULT - Z200, COMP, MCD, ABOVE CENTER BOX, FLOOR PANEL241XCF, LOWER SURFACE HAS SEVERAL DENTS/PUCTURES(APPROX 30 EA) AND EDGE DAMAGED. DOT 103-34. FABRICATED MCD FLOOR PANEL 241XCF, IAW UPS SREO: B757-9692-REQ 001 REVIEWEDSDR IPXA2025040744465Floor Panel · damagedFAULT - Z200, COMP, MCD, ABOVE CENTER BOX, FLOOR PANEL242XCF HAS SEVERAL DENTS AND PUCTURES (APPROX 23 EA). DOT 103-03. FABRICATED MCD FLOOR PANEL 242XCF, IAW UPS SREO: B757-9692-REQ 001 REVIEWEDSDR IPXA2025040744904Floor Panel · damagedFAULT - Z200, COMP, MCD, ABOVE CENTER BOX, FLOOR PANEL 242XEF HAS EDGE DAMAGED. DOT 103-15. FABRICATED MCD FLOOR PANEL 242XEF, IAW UPS SREO: B757-9692-REQ 001 REVIEWEDSDR IPXA2025040744974Floor Panel · damagedCOMP, MCD, ABOVE CENTER BOX, FLOOR PANEL 242XHF HAS EDGE DAMAGED. DOT 103-16. FABRICATED MCD FLOOR PANEL 242XHF, IAW UPS SREO: B757-9692-REQ 001 REVIEWEDSDR IPXA2025040444974Floor Panel · puncturedMCD, ABOVE CENTER BOX, FLOOR PANEL 242XHF HAS EDGE DAMAGED.SDR IPXA2025040405454Floor Panel · puncturedMCD, ABOVE CENTER BOX, FLOOR PANEL241XBF HAS SEVERAL DENTS/PUCTURES (APPROX 45 EA), LOWER/UPPER SURFACE AND EDGE DAMAGED. REJECT- SREO AMT LABOR ROW NEEDS SIGNED OFF FINISH.SDR IPXA2025040445296Floor Panel · punctured**SDR FILED OPEN** FAULT - Z200, COMP, MCD, ABOVE CENTER BOX, FLOOR PANEL241XDF, LOWER SURFACE HAS DENTS/PUCTURES (APPROX 2 EA) AND EDGE DAMAGED. DOT 103-29 AUDIT COMPLETESDR IPXA2025040244732Floor Panel · puncturedMCD, ABOVE CENTER BOX, FLOOR PANEL242XFF HAS SEVERAL DENTS/PUCTURES. FABRICATED MCD FLOOR PANEL 242XFF, IAW UPS SREO: B757-9692-REQ 001.SDR IPXA2025040345137Floor Panel · puncturedMCD, ABOVE CENTER BOX, FLOOR PANEL241XGF, LOWER SURFACE HAS DENTS/PUCTURES (APPROX 7 EA). FABRICATED MCD FLOOR PANEL 241XGF, IAW UPS SREO: B757-9692-REQ 001.SDR IPXA2025040144998Floor Panel · damagedMCD, ABOVE CENTER BOX, FLOOR PANEL 242XGF HAS CORNER AND EDGE DAMAGED. FABRICATED MCD FLOOR PANEL 242XGF, IAW UPS SREO: B757-9692-REQ 001.SDR IPXA2025040344864Floor Panel · puncturedMCD, ABOVE CENTER BOX, FLOOR PANEL242XBF HAS SEVERAL DENTS/PUCTURES (APPROX 33 EA) FABRICATED MCD FLOOR PANEL 242XBF, IAW UPS SREO: B757-9692-REQ 001.SDR IPXA2025040345010Floor Panel · puncturedMCD, ABOVE CENTER BOX, FLOOR PANEL242XDF HAS LOWER/UPPER SURFACE AND EDGE DAMAGED. FABRICATED MCD FLOOR PANEL 242XDF,, IAW UPS SREO: B757-9692-REQ 001 U.SDR IPXA2025040345190Floor Panel · puncturedMCD, ABOVE CENTER BOX, FLOOR PANEL241XJF HAS DENTS/PUCTURES AND EDGE DAMAGED. DOT 103-23. FABRICATED MCD FLOOR PANEL 241XJF, IAW UPS SREO: B757-9692-REQ 001. REVIEWEDSDR IPXA2025040245283Floor Panel · puncturedMCD, ABOVE CENTER BOX, FLOOR PANEL241XEF HAS SEVERAL DENTS/PUCTURES(APPROX 7 EA) AND EDGE DAMAGED. FABRICATED MCD FLOOR PANEL 241XEF, IAW UPS SREO: B757-9692-REQ 001.SDR IPXA2025040345063Floor Panel · puncturedMCD, ABOVE CENTER BOX, FLOOR PANEL241XHF LOWER SURFACE HAS SEVERAL DENTS/PUCTURES(APPROX 20 EA) AND EDGE DAMAGED. FABRICATED MCD FLOOR PANEL 241XHF, IAW UPS SREO: B757-9692-REQ 001.SDR IPXA2025041037198Firewall · crackedNR 1 ENG LP COMPRESSOR INNER CASE AFT BULKHEAD FIREWALL WITH CRACK BTW 8-9 O'CLOCK. INSTALLED ENGINE#1 LH CENTER COMPRESSOR FAIRING OF LP COMPRESSOR INNER CASE. I.A.W AMM 72-03-01-424-006-R00. ACCOMPLISHED STEP 15 OF EO 535-7200-14571. INSTALLATION OF ENGINESDR IPXA2025041037319Case · crackedNR 1 ENG LP COMPRESSOR INNER CASE AFT AREA BTW 8-10 O'CLOCK WITH CRACKS AROUND HOLES (2 EA). REPAIR OF #1 ENG LP COMPRESSOR INNER CASE AFT AREA BTW 8-10 O'CLOCK ACCOMPLISHED ON JOB # T3F18E00694S2. I.A.W AMM 72-03-01-024-007-R00.SDR IPXA2025040837319Case · crackedNR 1 ENG LP COMPRESSOR INNER CASE AFT AREA BTW 8-10 O'CLOCK WITH CRACKS AROUND HOLES (2 EA)-DOT 139/45-MR/139. REVIEWEDSDR IPXA2025032503443Sill Drain · corrodedFLOOR STRUCTURE, SUB-FLOOR PANEL AT MAIN CABIN COMPARTMENT RBL 50. UNDER FWD RH DRAIN HAS CORROSION AT NUTPLATE AREA. DOT 28-16. REPLACED NUTPLATE AT MAIN CABIN COMPARTMENT RBL 50 IAW SRM 51-40-02-0G-0. REVIEWED.SDR IPXA2025031311399Floorbeam · corrodedFS 1180- FS1240 LBL 62 UPPER T-CHORD FALNGE IS EXFOLIATED AT FS1218-FS1224.REMOVED CORROSION FROM UPPER T-CHORD SURFACE, FS 1218-FS 1224 LBL 62, IAW 757-200PF SRM 51-10-02. EVALUATED REWORK.REMOVED CORRODED T-CHORD FROM FS1180-FS1240 LBL 62 IAW 757-200PF SRM 5SDR IPXA2025031311380Floorbeam · corrodedFS 1220 LBL 65 TO LBL 70 UPPER PART OF T-CHORD FLANGE IS EXFOLIATED.REMOVED T-CHORD ON FS 1220 LBL 65 TO LBL 70 IAW B757-200, SRM 51-40-02, EVALUATED AND FOUND OUT OF LIMITS IAW B757-200, SRM 53-00-71-1A-1 DETAIL IX.INSTALLED NEW T-CHORD AT STA1220 LBL65-70 ANSDR IPXA2025041087698Skin · damagedRIGHT WING SLAT NR 8 OUTER SURFACE T/E WEDGE HAS 5 DENTS. INSTALLED #8 SLAT IAW AMM 27-81-02-424-021. REVIEWEDSDR IPXA2025031180414Skin · cracked**SUPPLEMENTAL SDR** Z600 STR FAULT: RH WING FIXED LE SKIN UNDER SLAT #7 HAS A CRACK ON OB SIDE OF SKIN. INSTALLED RH WING FIXED LE SKIN REPAIR UNDER SLAT #7 IAW SREO-11855-REQ002 STEPS 1 THROUGH 31 WITHOUT DEVIATIONS. ACCCOMPLISH SREO-11855-REQ002 (APPX B)SDR IPXA2025040180414Skin · crackedRH WING FIXED LE SKIN UNDER SLAT #7 HAS A CRACK ON OB SIDE OF SKIN VERIFIED STEPS 31 TO 33 OF SREO-11855-REQ002 (APPX B) ARE COMPLETED.<BR>RIGGING OF SLATS WILL BE ACCOMPLISHED ON TASK CARDS T3F18E0068H5E & T3F18E0068KDC.SDR IPXA2025031265344Floorbeam · erodedFS 900 BL 0 TO RBL 72 HAS CHAFING ON T-CHORD AND PAINT ERODED AWAY. INSTALLED 1EA OUTER CHORD & 8EA SPLICE IAW SRM B757-200 TASK: 51-40-02. REVIEWEDSDR IPXA2025041065680Strap · corrodedUPPER APU INTAKE DOOR SURROUND STRAP P/N 148N3138-20 AT FS 1787 HAS CORROSION WITH CORRODED NUTPLATES. INSTALLED FWD STRAP P/N 148N3138-20 PER B757 SRM 51-40-02 P/N BACR15CE8KE7 BACH # 4256147 (35 EA) RIVETSSDR IPXA2025041065760Strap · damagedFS 1825 UPPER FUSELAGE APU DOOR SURROUND STRAP P/N 148N3138-8000 HAS CORROSION AND CORRODED NUTPLATES. INSTALLED (3EA) STRAPS AND (1EA) FILLER PER B757 SRM 53-80-15-2R-1 HL P/N BACB30NW8K8X BACH #4374992 COLLAR P/N HL70-8 (235 EA) HL.SDR IPXA2025031265885Support Angle · corrodedUPPER FUSELAGE FS 1820-FS1795 DOOR SURROUND LOWER STRAP AT STR 6R P/N 148N3152-1 HAS CORROSION. INSTALLED ANGLE STR6 PER SRM 51-40-02 RIVET P/N BACR15FT6D7C BACH #4364973 (30 EA)RIVETS.SDR IPXA2025031265833Support Angle · corrodedUPPER FUSELAGE APU DOOR SURROUND FS1795 - FS1820 P/N 148N3152-2 AT STR 3R IS CORRODED. INSTALLED ANGLE STR3 PER SRM 51-40-02 RIVET P/N BACR15FT6D7C BACH #4364973 (30 EA) RIVETS.SDR IPXA2024092765141Indicator · malfunctionedENTRY DOOR LIGHT DID NOT GO OUT UPON CLOSING DOOR AT DEPARTURE R&R L1 DOOR PROX SENSOR PER MM 52-71-00-000-802. ADJ PER MM 52-71-00-825-223. TESTS GOOD. CLEARS DEFERRALSDR IPXA2024092465141Indication Sys · faultedENTRY DOOR LIGHT DID NOT GO OUT UPON CLOSING DOOR AT DEPARTURE PLACARDED CREW ENTRY DOOR INDICATION IAW MEL 52-71-1. DMP COMPLIED WITH. PLACARD INSTALLED OPENSDR IPXA2024012929679Bumper · missing*** SUPPLEMENTAL SDR *** CREW DOOR DAMPER BUMPER MISSING REPLACED MISSING BUMPERSDR IPXA2024012529679Bumper · missing**SDR FILED OPEN**CREW DOOR DAMPER BUMPER MISSING REPLACED MISSING BUMPERSDR IPXA2023031191744Frame · dentedINSPECTION TYPE:CK1CAFT CARGO PIT FRAME STA 1500 BETWEEN STR 25R AND 26R HAS A DENT.FRAME WAS REPAIRED PER RCD 272034 / SRM 53-00-07-2R-5 DETAIL IIISDR IPXA2023031091731Frame · dentedINSPECTION TYPE:C13*MAJOR REPAIR* FWD CARGO PIT FRAME 680 RH BETWEEN STR 23 TO STR 27 HAS AN EXISTING REPAIR WITH DENTREPAIRED PER UPS RCD 267664 - SRM 53-00-07-2R-5 DETAIL I.SDR IPXA2023031191748Frame · dentedINSPECTION TYPE:SEG1*MAJOR REPAIR* AFT CARGO PIT - FRAME AT STA 1220 BETWEEN STR 26 AND 27 RH SIDE HAS A DENTFRAME WAS REPAIRED IAW RCD 272032 / SRM 53-00-07-2R-6 DETAIL ISDR IPXA2022053082667Eicas · fault messageINSPECTION TYPE:NA***DIVERSION*** CABIN ALT WARNINGT/S IAW FIM 21-30-00-815-802, FOUND AC MOTOR #2 AT FAULT. M.M 7392277. R/R AC MOROT #2 IAW AMM 21-31-05 PB401 NO HELP .NN 7392277; REMOVED AND REPLACED OUTFLOW VLV ASSY IAW AMM 21-31-03. ACCOMPLISHED OPS CHECKSDR IPXA2022012578266Tat Probe · noneINSPECTION TYPE:N/A**ATB SDR FILED**NO EMERG**REQ'D RADAR VECTORS**A/C LANDED WITHOUT INCIDENT** AFTER ROTATION ON T.O RECIEVED TAT PROBE EICAS. A FEW MINUTES LATER RECIEVED L AND R ENG EEC EICAS. ACCOMPLISHED APPROPRIATE QRH CHECHLIST AIR TURNBACKFOLLOWED FIMSDR IPXA2021110575635Floor Panel · damagedINSPECTION TYPE:SEG4MAIN CARGO COMPARTMENT, FLOOR PANEL 241XKF IS DAMAGED.FABBED PANEL 241XKF FROM 5024N400001SS-G, BATCH# 3855547 PER SREO B757-5320-9662-KSDR IPXA2021110575633Floor Panel · damagedINSPECTION TYPE:SEG4MAIN CARGO COMPARTMENT, FLOOR PANEL 241XFF IS DAMAGED.FABBED PANEL 241FF FROM 5024N400001SS-G, BATCH#3855547 PER SREO B757-5320-9692-K.SDR IPXA2021021065528Inertia Reel · brokenINSPECTION TYPE:N/AIN TURBULENCE COVER FELL OFF INERITAL REEL AND HANDLES FELL OUT TO THE FLOORREMOVED AND REPLACED 2EA DESCENT DEVICES IAW AMM 25 61 02 252 005 IPC 25 61 01 01 ITEM 70SDR IPXA2020060155925Transmission · malfunctionedEMERGENCY DECLARED LANDED W/O INCIDENT. DURING APPROACH, WHEN FLAPS 1 SELECTED, TE FLAP DISAGREE EICAS MSG RECEIVED. USED ALT FLAPS PER CHECKLIST. LT INBD FLAP INBD FLAP TRANSMISSION PREVIOUSLY INDICATED AN OVERLOAD. IAW FIM 27-51-00-815, FOUND LT INBD TE SDR IPXA2019101657945Floor Panel · damagedINSPECTION TYPE:C1MAIN CARGO COMPARTMENT, FLOOR PANEL 221XCF DAMAGEDFABBED PANEL 221XCF FROM 5024N00001SS-G, BATCH# 3546253 PER SREO B757-5320-9692-KSDR IPXA2019101647905Floor Panel · damagedINSPECTION TYPE:C1, MAIN CABIN FLOOR BOARD #231XCF IS SATURATED WITH SKYDROL FLUID.FABBED 231XCF FROM 5024N40000155-G, BATCH# 3546253 PER SREO B757-5320-9692-K