What was found
INSPECTION TYPE:N/A**ATB SDR FILED**NO EMERG**REQ'D RADAR VECTORS**A/C LANDED WITHOUT INCIDENT** AFTER ROTATION ON T.O RECIEVED TAT PROBE EICAS. A FEW MINUTES LATER RECIEVED L AND R ENG EEC EICAS. ACCOMPLISHED APPROPRIATE QRH CHECHLIST AIR TURNBACKFOLLOWED FIM 30-33-00-815-802 FIG 103 FOUND POPPED TAT PROBE BREAKER, FOLLOWED FIM TO BLOCK 21. R&R K10264 IAW SWPM 20-81-12. OPS TEST OF TOTAL AIR TEMPERATRE PROBE HEAT SYSTEM CHECKED GOOD FIM 30-33-00-815-802. OPS TESTED TAT PROBE EAT SYS W ENG'S RUNNING IAW AMM 30-33-00. NO FAUTLS FOUND. OPS CHECK GOOD.