- Registered owner
- Hawaiian Airlines Inc
- Location
- Honolulu, HI
- Owner type
- Corporation
- Serial number
- 55184
- Year built
- 2005
- Type
- Fixed wing multi engine
- Engine
- Turbo-fan
- Airworthiness
- Standard, transport
- Airworthiness date
- March 30, 2005
- Certificate issued
- February 21, 2024
- Expires
- February 28, 2031
- Mode S code
- A61BED
From the FAA registry file of October 24, 2026. The registry lists only the engine series, so ADs for every Rolls-Royce BR-700 model are included below.
On this page
Airworthiness directives that may apply · 78
Matched by this aircraft’s airframe and engine models. Each AD’s applicability may narrow it by serial number, part number or equipment.
| 1999 | 1 |
|---|---|
| 2000 | 3 |
| 2001 | 5 |
| 2002 | 3 |
| 2003 | 6 |
| 2004 | 5 |
| 2005 | 4 |
| 2006 | 2 |
| 2007 | 7 |
| 2008 | 5 |
| 2009 | 4 |
| 2011 | 4 |
| 2012 | 3 |
| 2013 | 6 |
| 2014 | 5 |
| 2015 | 1 |
| 2016 | 2 |
| 2017 | 2 |
| 2018 | 4 |
| 2020 | 1 |
| 2021 | 5 |
| 2022 | 1 |
| 2023 | 5 |
| 2024 | 2 |
| 2025 | 2 |
| 2026 | 4 |
See all 92 ADs
Information bulletins that may apply · 4
Advisory, not mandatory.
NTSB investigations
No NTSB investigations matched to N493HAMatched by N-number and event date, checked against the reported serial number, make and model. Investigations from before this aircraft carried the mark are under Earlier aircraft. Investigations on Boeing 717-200 aircraft
FAA incident reports
No FAA accident or incident reports matched to N493HAMatched by N-number and event date, checked against the reported make and model. Reports from before this aircraft carried the mark are under Earlier aircraft. Reports on Boeing 717-200 aircraft
Service difficulty reports · 37
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR HALA20250530030Light · detachedROW 18D,E,F, FLOOR GUIDE LIGHT DETACHED. REPLACED DETACHED LUMINESCENT STRIP AT ROW 18DEF. OK FOR SERVICE.SDR HALA20250121002Pump · faultedBTB "HYD L PUMP FIL" AFTER ENG START . PERFORMED FAULT ISOLATION PROCEDURE 29-10 TASK 801, UP TO ND INCLUDING STEP 801. F. (3) 01/19/2025. REMOVED AND REPLACED #1 ENG ENGINE DRIVEN HYDRAULIC PUMP PER AMM 29-11-01/401. OPS CHECK GOOD. LEAK CHECK GOOD. NO FAULTSSDR HALA20240729035Electrical Sys · faultedAIR TURNBACK (ATB) IN CLIMB BETWEEN 10,000 + 11,000 THERE WERE TWO (2) SEPARATE POWER INTERRUPTIONS, EACH LASTING 2-3 SECONDS, RESULTING IN MOMENTARILY LOSS OF ALL DU'S + VHFS. PERFORMED BITE OF EPCU PER AMM 24-21-02. NO FAULTS. RESET VIA 1+2. PERFORMED VIA 1+
See all 37 reportsSTCs that may be installed · 71
Approved for this aircraft’s airframe or engine model. The registry doesn’t record which STCs an aircraft has; its records do.
Airframe · Boeing 717-200
STC ST00885LAInstallation of fire extinguisher cartridges as replacements for Pacific Scientific fire extinguisher cartridges in fire extinguisher bottles.STC ST02463ATInstallation of an Intrusion/Penetration Resistance Flightdeck Door and Reinforced Flightdeck Door Surround.STC ST04122ATInstallation of an oven