N506CA
Service difficulty reports · 216
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N506CA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N506CA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA202056345Seat Track · corrodedLEFT FLOOR SEAT RAIL CORRODED BETWEEN FS 559+4.00 AND FS 559+85.50 AT LBL 9 (C-CHECK) RO 2/17/2021. REPLACED THE LT FLOOR SEAT RAIL AT FS 559+4.00 AND FS 559-85.50 AT LBL 9 IAW CRJ 200 AMM 53-01-11-400-802.SDR SWIA202056344Seat Track · corrodedRIGHT SIDE SEAT RAIL CORRODED BETWEEN FS 495.98 AND FS 439 AT STGR 15R (C-CHECK) RO 2/17/2021. INSTALLED REPLACEMENT RT SIDE SEAT RAIL BETWEEN FS 495.98 AND FS 439 AT STG 15R IAW CRJ 200 AMM 53-01-11-400-802 REF CAMP NR 22138913 FOR FABRICATION.SDR SWIA202056343Seat Track · corrodedRIGHT SIDE SEAT RAIL CORRODED BETWEEN FS 444.02 AND FS 495.98 AT STGR 15R (C-CHECK) RO 2/17/2021. REMOVED AND REPLACED THE RT SIDE SEAT RAIL BETWEEN FS 444.02 AND FS 495.58 AT STGR 15R IAW CRJ 200 AMM 53-01-11-400-802 REFERENCE ATTACHED CONTINUATION CARD FOR SDR SWIA202056342Seat Track · corrodedRIGHT SIDE SEAT RAIL CORRODED BETWEEN FS 409+112 AND FS 439 AT STGR 15R (C-CHECK) RO 2/17/2021. TECH REMOVED AND INSTALLED RT SIDE SEAT RAIL FROM FS 409+112 TO FS439 AT STGR 15R IAW AMM 53-01-11-400-802, REFER TO CAMP NR 22050271 FOR FABRICATION.SDR SWIA202056341Seat Track · corrodedRIGHT SIDE SEAT RAIL CORRODED BETWEEN FS 364 AND FS 409+18.02 AT STGR 15R (C-CHECK) RO 2/17/2021. REMOVED AND REPLACED THE RT SIDE SEAT RAIL IAW CRJ 200 AMM 53-01-11-400-802.SDR SWIA202056340Seat Track · corrodedLEFT SIDE SEAT RAIL CORRODED BETWEEN FS 535.02 AND FS 559.+79 AT STGR 15L (C-CHECK) RO 2/17/2021. TECH REMOVED AND REPLACED SEAT RAIL IAW CRJ 200 AMM 53-01-11-000/400-802.SDR SWIA202056339Seat Track · corrodedLEFT SIDE SEAT RAIL CORRODED BETWEEN FS 495.98 AND FS 535.02 AT STGR 15L (C-CHECK) RO 2/17/2021. TECH REMOVED AND REPLACED LT SIDE SEAT RAIL CORRODED BETWEEN FS 495.98 AND FS 535.02 AT STGR 15L IAW CRJ 200 AMM 53-01-11-400-802 REFER TO CAMP NR 22050222 FOR FASDR SWIA202056338Seat Track · corrodedLEFT SIDE SEAT RAIL CORRODED BETWEEN FS 444.02 AND FS 495.98 AT STGR 15L (C-CHECK) RO 2/17/2021. REMOVED AND REPLACED THE LT SIDE SEAT RAIL BETWEEN FS 444.02 AND 495.98 AT STGR 15L IAW CRJ 200 AMM 53-01-11-000/400-802 REFERENCE ATTACHED CONTINUATION CARD FOR SDR SWIA202056337Seat Track · corrodedLEFT SIDE SEAT RAIL CORRODED BETWEEN FS 409+112 AND FS 439 AT STGR 15L (C-CHECK) RO 2/17/2021. TECHNICIAN REMOVED OLD AND INSTALLED NEW SERVICEABLE LT SIDE SEAT RAIL BETWEEN FS 409+112 AND FS 439 AT STGR 15L IAW CRJ 200 AMM 53-01-11-000-802/ 53-01-11-400-802.SDR SWIA202056336Seat Track · corrodedLEFT SIDE SEAT RAIL CORRODED BETWEEN FS 409+18.02 AND FS 409+111.02 AT STGR 15L (C-CHECK) RO 2/17/2021. REPLACED THE LT SEAT RAIL BETWEEN FS 409+18.02 AND FS 409+111.02 AT STGR 15L IAW CRJ 200 AMM 53-01-11-400-802. REFERENCE ATTACHED CONTINUATION CARD FOR WOSDR SWIA202056365Floor Support · damagedRIGHT FLOOR SILL AT APPROX FS 559+32 AND RBL 42, NUT PLATE DAMAGED AND FASTENER HOLE ELONGATED. (C-CHECK) RO 2/17/2021. REMOVED AND REPLACED NUTPLATE AT RT FLOOR SILL AT APPROX FS 559+32 AND RBL 42 AND REAMED NUTPLATE HOLE IAW CRJ 200 SRM 51-45-00, 51-40-11.SDR SWIA202056356Floor Support · corrodedCARGO BAY RT FLOOR SILL, NUTPLATES CORRODED AT APPROX RBL 47 BETWEEN FS 589 TO FS 621. (C-CHECK) RO 2/17/2021. REMOVED DAMAGED NUTPLATES AND INSTALLED NEW NUTPLATES IAW CRJ 200 SRM 51-45-00.SDR SWIA202056335Clamp · corrodedPASSENGER DOOR, STGR 17L, FS 364.00 CORRODED HARDWARE THRU CORRUGATED PLATE (1 EACH) (C-CHECK) RO 2/17/2021. REPLACED CORRODED HARDWARE AND CORRUGATED PLATE AT PAX DOOR STGR 17L FS 364 IAW CRJ 200 AMM 52-11-17-400-804 REFERENCE ATTACHED CONTINUATION CARD FORSDR SWIA202056334Floor Support · corrodedFLOOR BEAM AT RBL 9 HAS MINOR CORROSION FROM FS 409.00 +128 TO FS 559.00 (C-CHECK) RO 2/17/2021. REPAIRED AREA OF CORROSION ON FLOOR BEAM AT RBL 9 BETWEEN FS 409+128 TO FS 559 IAW REO 601R-53-41-2839 REV -- DATED 2021-01-11.SDR SWIA202056333Strap · corrodedFLOOR SUPPORT STRAP AT FS 559.00 HAS MULTIPLE SPOTS OF CORROSION FROM LBL 27 TO LBL 45 (C-CHECK) RO 2/17/2021. REMOVED AND REPLACED FLOOR SUPPORT STRAP AT FS 559.00 IAW CRJ 200 SRM 51-42-06 AND 51-42-10. PRESSURE CHECK GOOD IAW CRJ 200 AMM 21-32-00-863-801.SDR SWIA202056332Strap · corrodedFLOOR SUPPORT STRAP AT FS 559.00 HAS MULTIPLE SPOTS OF CORROSION FROM RBL 27 TO RBL 45 (C-CHECK) RO 2/17/2021. REMOVED AND REPLACE FLOOR SUPPORT STRAP AT FS 559.00 RBL 27 TO RBL 45 IAW CRJ 200 SRM 51-42-06 AND 51-42-13.SDR SWIA202056331Intercostal · corrodedINTERCOSTAL AT STGR 20L CORRODED BETWEEN FS 319.70 AND FS 349.00 (C-CHECK) RO 2/17/2021. REPLACED THE INTERCOSTAL AT STGR 21L BETWEEN FS 319.70 TO FS 349.00 IAW CRJ 200 SRM 51-40-11, 51-42-06, 51-42-21. REFERENCE ATTACHED CONTINUATION CARD FOR WORK PERFORMEDSDR SWIA202056329Floor Support · corrodedRIGHT FLOOR SILL ANGLE HAS MULTIPLE SPOTS OF CORROSION FROM FS 409.00 +128 TO FS 559.00 (C-CHECK) RO 2/17/2021. COMPLIED WITH BOMBARDIER REO 601R-53-41-666 REV-C DATE 2012-11-06 STEP 2.2.SDR SWIA202056325Attach Angle · crackedPAX DOOR, CRACK AT @ FS 347.25, @ DATUM 7, CHANNEL BRACKETING AT PULLEY MOUNT INBD (C-CHECK) RO 2/17/2021. REMOVED AND REPLACED DAMAGED AFT DRAG ANGLE IAW CRJ 200 SRM 51-42-13 AND 51-42-06.SDR SWIA202056319Former · corrodedFORMER @ FS329.41 (PN 601R318088-1) CORRODED (C-CHECK) RO 2/17/2021. REMOVED AND REPLACED IAW CRJ200 SRM 51-42-06, 51-23-00, 51-25-16 REV 38B DATED 11/25/2020. SKYCARD 51-900-1003-SKY COMPLETED, FORM M-337 ATTACHED. WEIGHT AND BALANCE NOT AFFECTED.SDR SWIA202056318Intercostal · corrodedPAX DOOR, INTERCOSTAL, DD4 CORRODED (PN 601R318081-1) 52-10-14 ITEM 43 (C-CHECK) RO 2/17/2021. REMOVED AND REPLACED IAW CRJ 200 SRM 51-42-06, 51-42-21, 51-23-00, 51-25-16 REV 38B DATED 11/25/2020. SKYCARD 51-900-1003-SKY COMPLETED, FORM M-337 ATTACHED. WEIGSDR SWIA202056310Floor Support · corrodedRH FLOOR SILL HAS MULTIPLE SPOTS OF CORROSION FROM F.S. 409.00 +128 TO F.S. 559.00 (C-CHECK) RO 2/17/2021 REPAIRED RH FLOOR SILL FROM FS 409+128 TO FS 559 IAW REO 601R-53-41-666 REV C, DATED 2012-11-06, MAJOR REPAIR TASK CARD 51-900-1003-SKY COMPLETED ANDSDR SWIA202056309Former · corrodedPAX DOOR, FORMER @ FS329.76 (PN 601R318078-3) CORRODED (C-CHECK) RO 2/17/2021. REMOVED AND REPLACED IAW CRJ 200 51-42-06, 51-23-00, 51-25-16 REV 38B DATED 11/25/2020. SKYCARD 51-900-1003-SKY COMPLETED, FORM M-337 ATTACHED. WEIGHT AND BALANCE NOT AFFECTED.SDR SWIA202056308Floor Support · corrodedLEFT FLOOR SILL HAS MULTIPLE SPOTS OF CORROSION FROM FS 409.00 +128 TO FS 559.00 (C-CHECK) RO 2/17/2021. REPAIRED LT FLOOR SILL FS 409+128 TO FS 559.00 IAW C REO 601R-53-41-666 REV C, DATED 2012-11-06, COMPLETED TASK CARD 51-900-1003- SKY AND FORM M-337. SDR SWIA202056307Intercostal · corrodedPAX DOOR, INTERCOSTAL, DD6 CORRODED (PN 601R318057-1) 52-10-14 ITEM 33 (C-CHECK) RO 2/17/2021. REMOVED AND REPLACED IAW SRMS 51-42-06 REV 38B DATED 11/25/2020 AND 51-42-21 REV 38B DATED 11/25/2020. SKYCARD 51-900-1003-SKY COMPLETED FORM M-337 ATTACHED. WEIGSDR SWIA202056303Floor Support · corrodedFLOOR BEAM AT LBL 9 HAS MINOR CORROSION FROM FS 409.00 +128 TO FS 559.00 (C-CHECK) RO 2/17/2021. REPAIRED AREA OF CORROSION AT LBL 9 BETWEEN FS 409.00+128 TO FS 559.00 IAW REO 601R-53-41-2846 REV -- DATED 2021-01-22, SKYWEST TASK CARD 51-900-1003-SKY AND FORMSDR SWIA202056364Floorbeam · crackedFOUR EA FS 280.00 ATTACH CLIPS CRACKED AT RBL 9 AND LBL 9. (C-CHECK) RO 2/17/2021. REPLACED 4 EA ATTACHING CLIPS AT FS 280 FROM RBL 9 TO LBL 9 IAW CRJ 200 SRM51-40-11 AND 51-24-36.SDR SWIA202056330Dampener · corrodedLEFT AILERON FLUTTER DAMPENER, LOWER AFT ATTACH BOLT ON ROD END HAS CORRODED NUT (C-CHECK) RO 2/17/2021. R & R LT AILERON FLUTTER DAMPENER, ATTACH BOLT ON ROD END IAW CRJ 200 AMM 27-15-01-000/400-801.SDR SWIA202056324Doubler · crackedFS 280.00 BEAM REPAIR DOUBLER AT RBL 13 CRACKED. (C-CHECK) RO 2/17/2021. REPLACED THE DOUBLER ON FS 280 AT RBL13 IAW CRJ 200 SRM 51-40-11 AND 51-24-36.SDR SWIA202056317Floor Support · corrodedFLOOR BEAM AT LBL 9 HAS MULTIPLE SPOTS OF MINOR CORROSION FROM FS 409.00 +80 TO FS 409.00 +128 (C-CHECK) RO 2/17/2021. REPAIRED FLOOR BEAM AT LBL 9 BETWEEN FS 409.00+80 TO FS409.00+128 IAW CRJ200 SRM 51-42-21, 51-42-10, 51-42-22 AND SKYWEST TASK CARD 51-900-1SDR SWIA202056312Pressure Deck · gougedWHILE REMOVING SCREWS UNDER FLOOR PANEL 262DRF PRESSURE FLOOR RT SIDE SILL FOUND GOUGE BETWEEN FS 484.00 AND 499.00. (MARKED WITH RED TAPE) (C-CHECK) RO 2/17/2021. REPAIRED FLOOR SILL GOUGES UNDER FLOOR PANEL 262DRF PRESSURE FLOOR RT BETWEEN FS 484.00 AND 49SDR SWIA202056367Floor Panel · brokenFLOOR PANEL 262DRF WAS DISCOVERED TO HAVE MULTIPLE SCREW SHANKS BROKEN OFF INSIDE NUTPLATES STICKING OUT OF PRESSURE FLOOR RT SIDE SILL. (C-CHECK) RO 2/17/2021. REMOVED AND REPLACED NUTPLATES FOR FLOOR BOARD 262DRF IAW CRJ 200 SRM 51-42-06.SDR SWIA202056362Tape · chafedRIGHT WING FRONT SPAR IS MISSING WHITE ANTI-CHAFE TAPE AT NUMEROUS LOCATIONS. REPLACE AS REQUIRED. (UPPER AND LOWER) (C-CHECK) RO 2/17/2021. REPLACED UPPER AND LOWER RT WING FRONT SPAR MISSING ANTI CHAFE TAPE IAW CRJ200 AMM 57-41-01-400-803, AMM 57-41-01-40SDR SWIA202056361Stop Fitting · chafedFOUR MAIN AVIONICS BAY DOOR STOP FITTINGS AROUND AVIONICS DOOR CUTOUT ARE CHAFED, (2) AFT, (1) RT AND (1) RT FORWARD. (C-CHECK) RO 2/17/2021. REMOVED AND REPLACED 4 EA STOP FITTINGS AROUND THE AVIONICS BAY DOOR CUTOUT IAW CRJ-200 AMM 20-21-00-910-801.SDR SWIA202056328Link · corrodedRIGHT AILERON POSITION TRANSMITTER LINK ARM HARDWARE IS CORRODED (C-CHECK) RO 2/17/2021. REMOVED CORRODED HARDWARE, INSTALLED SERVICEABLE HARDWARE TO RT AILERON POSITION TRANSMITTER LINK ARM IAW CRJ-200 AMM 27-15-01-400-801 & CRJ-200 AMM 27-15-15-400-801.SDR SWIA202056327Rod · corrodedLEFT AILERON MOST OTBD-LOWER AFT ATTACHMENT ROD, NUT ON MOUNT BOLT IS CORRODED (C-CHECK) RO 2/17/2021. REMOVED AND REPLACED NUT ON LT AILERON FLUTTER DAMPER AFT MOUNT BOLT IAW CRJ 200 AMM 27-15-01-000/400-801.SDR SWIA202056313Stringer · crackedSTRINGER 3L IS CRACKED AT FS 379.00. (C-CHECK) RO 2/17/2021. REMOVED AND REPLACED STRINGER 3L FS 379.00 IAW CRJ-200 SRM 53-00-03, TASK CARD 51-900-1003-SKY AND 337 FORM NO WEIGHT CHANGES. REFER TO CONTINUE CARD FOR MAINTENANCE ACTION.SDR SWIA202056360Stop Fitting · corrodedPAX DOOR FUSELAGE FWD LWR PIN STOP FITTING IS CHAFED. (C-CHECK) RO 2/17/2021. REPLACED THE PAX DOOR FUSELAGE FWD LWR PIN STOP FITTING IAW CRJ 200 AMM 53-21-23-400-801 REFERENCE ATTACHED CONTINUATION CARD FOR WORK PERFORMED.SDR SWIA202056359Stop Fitting · chafedPAX DOOR FUSELAGE FWD CENTER PIN STOP FITTING IS CHAFED. (C-CHECK) RO 2/17/2021. REPLACED THE PAX DOOR FUSELAGE FWD CENTER PIN STOP FITTING IAW CRJ 200 AMM 53-21-23-400-801 REFERENCE ATTACHED CONTINUATION CARD FOR WORK PERFORMED.SDR SWIA202056316Skin · dentedMULTIPLE DENTS FOUND ON RT SIDE OF FUSELAGE BETWEEN LE OF WING AND AFT OF SERVICE DOOR JUST ABOVE FLOOR LINE. ALL DENTS MARKED. PLOT, MAP, AND EVALUATE DAMAGE IF WITHIN ACCEPTABLE LIMITS OR REWORKED, ELIMINATE EVIDENCE USING STANDARD ACFT PRACTICES. (C-CHECSDR SWIA20190405694Skin · chafedRT INBOARD FLAP VANE LEADING EDGE INBOARD MOST SKIN HAS CHAFING DAMAGE. (C-CHECK) RO: 03/29/2019 REMOVED AND INSTALLED NEW RH IB FLAP VANE IB LE CAP IAW AMM.SDR SWIA201904025711Angle · corrodedPAX DOOR FLOOR SURROUND STRUCTURE VERTICAL ANGLE HAS CORROSION ON FUSELAGE SIDE. (C-CHECK) RO: 03/29/2019 REMOVED AND REPLACED PAX DOOR FLOOR SURROUND STRUCTURE VERTICAL ANGLE IAW SRM. ALL CHECKS GOOD.SDR SWIA201904025710Cleat · corrodedPAX DOOR FLOOR SURROUND STRUCTURE ON FUSELAGE SIDE FWD AND AFT CLEATS HAVE CORROSION. (C-CHECK) RO: 03/29/2019 INSTALLED NEW FWD AND AFT CLEATS IAW SRM.SDR SWIA2019040245709Intercostal · corrodedPAX DOOR INTERCOSTAL AT DD4 BETWEEN FS.347.27 AND FS.339.27 (AFT SIDE OF DOOR) HAS CORROSION. (C-CHECK) RO: 03/29/2019 INSTALLED NEW PASSENGER DOOR INTERCOSTAL DD4 P/N 601R31902-317 IAW SRM. NO LEAKS NOTED, OPS CHECKS GOOD .SDR SWIA201904025708Intercostal · corrodedPAX DOOR INTERCOSTAL AT DD3 BETWEEN FS.347.27 AND FS.339.27 (AFT SIDE OF DOOR) HAS CORROSION. (C-CHECK) RO: 03/29/2019 INSTALLED NEW PASSENGER DOOR INTERCOSTAL DD3 P/N 601R318055-1 IAW SRM. NO LEAKS NOTED.SDR SWIA201904025707Skin · dentedPROTRUDING DENT ON L/H FUSELAGE SKIN BETWEEN FS 755. TO REAR STABILIZER SPAR BELOW TIE DOWN ATTACH FITTING APROX STGR 22L (C-CHECK) RO: 03/29/2019 COMPLIED WITH REPAIR TO THE PROTRUDING DENT ON L/H FUSELAGE SKIN BETWEEN FS 755 REF IAW REO ALL STEPS.SDR SWIA201904025705Frame · corrodedREPLACE LOWER FRAME SECTOR FS.605.00 WITH NEW DUE TO CORROSION. (C-CHECK) RO: 03/29/2019 REMOVED DAMAGED LOWER FRAME SECTOR FS.605.00 ASSY FROM STR 20R TO ST 20L AND INSTALLED NEW LOWER FRAME SECTOR FS 605.00 ASSY IAW SRM. NO LEAKS NOTEDSDR SWIA201904025706Floor Support · corrodedLEFT FLOOR SILL HAS CORROSION AROUND THE FASTENER HOLES FS559.00 €“ FS559.00+80. (C-CHECK) RO: 03/29/2019 REMOVED AND REPLACED DAMAGED LH FLOOR SILL BETWEEN FS 559.00- FS 559+80 WITH NEW LH FLOOR SILL P/N: 601R31133-77S IAW SRM.SDR SWIA201904025704Floor Support · corrodedFEED THRU PLATE ON TOP OF RH FLOOR SILL BETWEEN FS 409+112 AND FS 409+128 HAS CORROSION. (C-CHECK) RO: 03/29/2019 BLENDED CORROSION ON R/H FEED THRU PLATE/REINFORCING DOUBLER ON FLOOR SILL BETWEEN FS 409+112 AND FS 409+128 IAW SRM AND REO.SDR SWIA201904025703Floor Support · corrodedFEED THRU PLATE ON TOP OF LH FLOOR SILL BETWEEN FS 409+112 AND FS 409+128 HAS CORROSION. (C-CHECK) RO: 03/29/2019 BLENDED CORROSION ON L/H FEED THRU PLATE/REINFORCING DOUBLER ON FLOOR SILL BETWEEN FS 409+112 AND FS 409+128 IAW SRM AND REO.
Back to N506CA