N553AA
Service difficulty reports · 96
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N553AA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N553AA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20090805TUL09Battery Pack · dischargedEMERGENCY AISLE BATTERY PACK IS WEAK. REMOVED AND REPLACED WITH SERVICEABLE BATTERY PACK IAW MM 33-60-98-4.SDR AALA20090731TUL19Stop Fitting · crackedFORWARD CARGO AFT SECOND FROM INBOARD DOOR STOP CASTING CRACKED. REMOVED AND REPLACED STOP BRACKET UNDER ESO 80174.SDR AALA2009021400742Strap · brokenLGA FORWARD UPPER EMERGENCY FLASHLIGHT SAFETY STRAP BROKEN. REPLACED SAFETY STRAP FOR FORWARD UPPER EMERGENCY FLASHLIGHT.SDR AALA2009021400489Battery · dischargedLGA FORWARD UPPER EMERGENCY FLASHLIGHT BATTERY LOW. REPLACED BATTERY FOR FORWARD UPPER EMERGENCY FLASHLIGHT.SDR AALA2009021400488Battery Pack · dischargedLGA AFT EMERGENCY EXIT PATH LIGHTING INOPERATIVE. REPLACED BATTERY PACK AT AFT EMERGENCY EXIT.SDR AALA200800752Battery Pack · inoperativeLGA - EMERGENCY LIGHT AT MID CABIN OVERWING INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS AT MID CABIN OVERWING. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA200800751Battery Pack · inoperativeLGA - EMERGENCY LIGHTS AT FORWARD GALLEY INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS AT FORWARD GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20072529Battery Pack · inoperativeLGA - EMERGENCY LIGHTS AT FIRST CLASS GALLEY INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS AT FIRST CLASS GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20072528Battery Pack · inoperativeLGA - EMERGENCY LIGHT AT SEAT ROW 29 INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHT AT SEAT ROW 29. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20072361Wire · chafedPHX INFLIGHT T1658/02DEC PSP-DFW - DURING CLIMB AIRCRAFT EXPERIENCED AN UNCOMMANDED RUDDER INPUT. LANDED PHX WITHOUT INCIDENT. FOUND CHAFED WIRE FOR RIGHT POSITION SENSOR IN AFT TAIL COMPARTMENT. REPAIRED WIRE FOR RIGHT DUEL SERVO RUDDER POSITION SENSOR IN SDR AALA20072277Lens · missingLGA - EMERGENCY LIGHT AT SEAT 13D MISSING LENS. REPLACED LENS FOR EMERGENCY LIGHT AT SEAT 13D. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20072276Lamp · missingLGA - EMERGENCY LIGHT AT SEAT 13D MISSING LAMP. REPLACED LAMP FOR EMERGENCY LIGHT AT SEAT 13D. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20071904Tube · leakingDFW INFLIGHT T2485/09OCT ORD TO AUS - NUMBER ONE ENGINE HIGH OIL TEMPERATURE INDICATION. ALL OTHER ENGINE INDICATIONS NORMAL. CREW SHUT DOWN NUMBER ONE ENGINE. DIVERTED TO DFW AND LANDED WITHOUT INCIDENT. SINGLE ENGINE TIME 25 MINUTES. FOUND OIL LEAK FROSDR AALA20071344Battery Pack · inoperativeLGA - EMERGENCY LIGHTS AT TAILCONE INOPERATIVE. REPLACED BATTERY PACK AT LEFT AFT LAVATORY OVERHEAD FOR EMERGENCY LIGHTS AT TAILCONE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20070692Seal · damagedJFK INFLIGHT T1977/15APR NOSE LANDING GEAR WOULD NOT RETRACT. LANDED JFK WITHOUT INCIDENT. REPLACED NOSE LANDING GEAR STRUT SEALS AND SERVICED NOSE LANDING GEAR. SYSTEM GROUND CHECKED NORMAL OPERATION. (CLOSED)SDR AALA20061175Compressor · stalledDFW - ON TAKEOFF ROLL CREW HEARD LOUD BANG AND AIRCRAFT YAWED TO THE RIGHT. RETURNED TO DFW AND LANDED WITHOUT INCIDENT. REPLACED NUMBER TWO ENGINE ON 07 DEC 2006 AT DFW DUE TO STEADY STATE COMPRESSOR STALLS. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20040773Battery Pack · inoperativeDFW - EMERGENCY CEILING LIGHTS AT SERVICE DOOR AND STATIONS 1100 THROUGH 1200 INOPERATIVE. REPLACED BATTERY PACK AT STATION 1190R FOR EMERGENCY CEILING LIGHTS AT SERVICE DOOR AND STATIONS 1100 THROUGH 1200. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20040266Battery · not seatedRDU - OVERHEAD EMERGENCY LIGHTS AT AFT GALLEY SERVICE AREA INOPERATIVE. RESEATED BATTERY AT POSITION B5-107 FOR OVERHEAD EMERGENCY LIGHTS AT AFT GALLEY SERVICE AREA. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031326Slide · malfunctionedL2 DOOR SLIDE INADVERTENTLY AND UNSUCCESSFULLY DEPLOYED BY CABIN SERVICE. DRIVER OPENED AFT SERVICE DOOR WHILE SLIDE WAS ARMED. RUG TRUCK PLATFORM PREVENTED FULL DEPLOYEMENT OF SLIDE. REPLACED SLIDE ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20030743Battery · inoperativeORD - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT IN FIRST CLASS INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT BATTERY IN FIRST CLASS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20021532Casting · gougedTUL - FOUND LEADING EDGE SLAT CABLE PULLEY CUT GROOVE IN NR 1 SLAT CASTING INBOARD SIDE FORWARD SIDE OF CASTING RT WING. BLENDED GOUGE AND INSTALLED DOUBLER PER ESO 80559. (M)SDR AALA20021531Longeron · damagedTUL - FOUND LONGERON DAMAGED 1 INCH AFT OF STATION 1338, STRINGER 17L. INSTALLED LONGERON SPLICE PER SRM 53-02-00 AND AARD 53-00-00-05. (M)SDR AALA20021521Frame · gougedTUL - FOUND GOUGE IN STATION 1380 FRAME FORWARD SIDE AT STATION 5L. FABRICATED DOUBLER, ALODINED AND PRIMED AND INSTALLED DOUBLER AT STATION 1380 SRM 51-70-4. (M)SDR AALA20021530Frame · crackedTUL - FOUND FRAME CRACKED IN RADIUS AFT SIDE STATION 1418, LONGERON 2R. STOP DRILLED CRACK. INSTALLED DOUBLER REPAIR PER SRM 53-01-0 PAGE 10. (M)SDR AALA20021529Skin · gougedTUL - FOUND 2 GOUGES STATION 231 LEFT BETWEEN LONGERON 17L AND 18L. DYE CHECKED DAMAGE, NO CRACKS. INSTALLED REPAIR DOUBLER PER SRM 53-04-00 FIG 38. (M)SDR AALA20021528Door Frame · corrodedTUL - FOUND INTERIM REPAIR ACCOMPLISHED ON AFT CARGO BEAM CORROSION, STATION 1174. REPLACED AFT CARGO DOOR CUT OUT, LOWER BEAM PER SRM 53-01-00. (M)SDR AALA20021527Web · crackedTUL - FOUND STATION 627 LEFT CUSP HAS .5 INCH CRACK EMITTING FROM INBOARD EDGE OF CENTER LIGHTENING HOLE. INSTALLED REPAIR DOUBLER PER AARD 53-00-00-02. (M)SDR AALA20021526Web · corrodedTUL - FOUND CORROSION ON FLOOR WEB AROUND GALLEY TIE DOWN STATION 170 RBL 11. REMOVED DAMAGE. INSTALLED DOUBLER PER SRM 53-01-00 FIG 4 SHEET 3. (M)SDR AALA20021523Web · crackedTUL - FOUND STATION 225-227 LEFT CUSP OUTBOARD OF NR 1 TRACK, CUSP HAS 2 INCH CRACK EMITTING FROM FORWARD SIDE OF LIGHTENING HOLE. STOP DRILLED, DYE CHECKED AND NO CRACKS FOUND. FABRICATED DOUBLER ALODINED, PRIMED AND INSTALLED PER MM 53-10-01. (M)SDR AALA20021522Skin · crackedTUL - FOUND SKIN CRACK AT FASTENER LONGERON 14L STATION 1380. REMOVED DAMAGE AND INSTALLED DOUBLER REPAIR PER SRM 53-01-00. (M)SDR AALA20021524Seat Track · crackedTUL - FOUND NR 4 SEAT TRACK, LUG CRACKED AT STATION 270. INSTALLED REPAIR PLUG PER AARD 53-20-00-10. (M)SDR AALA20021525Window Frame · crackedTUL - FOUND WINDOW INNER FRAME CRACKED AT STATION 845 UPPER CORNER. INSTALLED DOUBLER PER AARD 53-10-00. (M)SDR AALA20020109Battery Pack · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTS AT SEAT 18-21 INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20011178Wire · shortedDFW - FLT 369 - EN ROUTE DFW-BOS, SHORTLY AFTER TAKEOFF TAIL COMPARTMENT HIGH LIGHT ILLUMINATED. RETURNED DFW AND LANDED WITHOUT FURTHER INCIDENT. REPAIRED TAIL TEMPERATURE SENSOR WIRE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20010590Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, FORWARD EMERGENCY EXIT LIGHT DIM. REPLACED EMERGENCY EXIT LIGHT BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20010169Coalescer Bag · dirtyJFK - EN ROUTE LGA-ORD, DETECTED SMOKE AND HAZE IN CABIN AND COCKPIT. DIVERTED JFK AND LANDED WITHOUT FURTHER INCIDENT. REPLACED LEFT AND RIGHT SIDE COALESCER BAGS. ACCOMPLISHED HIGH POWER RUN UP. NO SMOKE OR HAZE NOTED. SYSTEM GROUND CHECKED NORMAL OPERASDR AALA20010152Sensor · malfunctionedMIA - FLT 1304 - EN ROUTE MIA-CLE, DETECTED TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED. AIR INTERRUPTED, RETURNED MIA AND LANDED WITHOUT FURTHER INCIDENT. REPLACED LEFT SIDE AFT TAIL COMPARTMENT OVERHEAT SENSOR. SYSTEM GROUND CHECKED NORMAL OPERATISDR AALA20001216Strut · lack of lubeDFW - FLT 1314 - AFTER TAKEOFF DURING GEAR RETRACTION, RED NOSE GEAR LIGHT AND GEAR DOOR OPEN LIGHT ILLUMINATED. NOSE GEAR REMAINED EXTENDED. RECYCLED AND GEAR RETRACTED NORMAL. CHECKED SENSORS, LUBRICATED STRUT AND ACCOMPLISHED GEAR SWING. SYSTEM GROUND CSDR AALA20001112Landing Gear · lack of lubeDFW - FLT 1126 - AFTER TAKEOFF, NOSE WHEEL FAILED TO RETRACT. RECYCLED DOWN THEN UP, RETRACTED NORMAL, CONTINUED AND LANDED DFW WITHOUT INCIDENT. GREASED GEAR. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA20000665Switch · defectiveLAX - FLT 1258 - AFTER TAKEOFF, RED NOSE GEAR LIGHT WOULD NOT EXTINGUISH WHEN GEAR HANDLE SELECTED UP. RE-CYCLED GEAR, NO HELP. LOUD NOISE HEARD. RETURNED AND LANDED LAX WITHOUT INCIDENT. REPLACED NOSE GEAR UP POSITION PROXIMITY SWITCH. ACCOMPLISHED GEAR SDR AALA991961Connector · looseDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT OVERHEAD LIGHT AT ROWS 19-20 INOPERATIVE. TIGHTENED LOOSE CONNECTOR ON EMERGENCY EXIT OVERHEAD LIGHT BATTERY PACK. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA991128Fan · defectiveLIT - FLT 791 - EN ROUTE LGA, DFW SMOKE AND ELECTRICAL SMELL DETECTED. AIRCRAFT AIR INTERRUPTED AND LANDED LIT WITHOUT INCIDENT. REPLACED CABIN AIR RECIRCULATION FAN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA971278Hyd Pump · defectiveDTW - FLT 1652 - EN ROUTE DFW/DTW, DURING CRUISE, RIGHT SIDE HYDRAULIC PRESSURE LOW LIGHT ILLUMINATED. ACCOMPLISHED ABNORMAL PROCEDURES AND AIRCRAFT PROCEEDED TO DTW, LANDING WITHOUT INCIDENT. REPLACED RIGHT ENGINE DRIVEN HYDRAULIC PUMP AND FILTER. SERVICEDSDR AALA960773Outflow Vlv Act · defectivePHX - FLT 1172 - AFTER TAKEOFF PHX DURING CLIMB-OUT, UNABLE TO PRESSURIZE A/C IN EITHER AUTO OR MANUAL MODE. ACCOMP EMERGENCY DESCENT AND ALL PAX OXYGEN MASKS SUCCESSFULLY DEPLOYED. A/C RETURNED TO PHX AND LANDED W/O INCIDENT. REPLACED NR 1 PRESSURIZATION CSDR AALA960135Wire · shortedORD - DURING MAINTENANCE TO REPAIR AN INOPERATIVE LT AIR CYCLE MACHINE COOLING FAN PREVIOUSLY PLACARDED INOP AT DFW/24, FOUND COOLING FAN WIRE BUNDLE SHORTED AND BURNED DUE TO CHAFING AT FIRST CLAMP AND BRACKET. REPLACED LT ACM COOLING FAN, REPLACED ELECTRICASDR AALA950910Clamp · brokenDFW - FLT 789 - AFTER TAKEOFF DFW DURING CLIMB-OUT, TAIL COMPARTMENT HIGH TEMPERATURE LIGHT ILLUMINATED. ACCOMPLISHED QRH PROCEDURES AND AIRCRAFT RETURNED DFW, LANDING WITHOUT INCIDENT. REPLACED LT AIR CYCLE MACHINE SUPPLY DUCT CLAMP. SYSTEM LEAK AND GROUND