SDR AALA960773

Service difficulty report · Outflow Vlv Act · Doug DC982

Difficulty date
May 14, 1996
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N553AA
Make and model
Doug DC982
Aircraft serial
53083
Part
Outflow Vlv Act
Part number
20219742
Condition
Defective
Location
Cabin
Stage of operation
CL
Nature of condition
J
Precautionary procedure
B, G, A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PHX - FLT 1172 - AFTER TAKEOFF PHX DURING CLIMB-OUT, UNABLE TO PRESSURIZE A/C IN EITHER AUTO OR MANUAL MODE. ACCOMP EMERGENCY DESCENT AND ALL PAX OXYGEN MASKS SUCCESSFULLY DEPLOYED. A/C RETURNED TO PHX AND LANDED W/O INCIDENT. REPLACED NR 1 PRESSURIZATION CONTROLLER AND GROUND CONTROL RELAYS R2-4 AND R2-106. SYSTEM GROUND CHECKED NORMAL OPERATION. A/C MAINTENANCE FERRY PHX/TUL. RESTOWED ALL PAX OXYGEN MASKS AND SERVICED PAX OXYGEN SYS. ACCOMPLISHED FUNCTIONAL CHECK FLIGHT AND PRESSURIZATION PROBLEM REPEATED. REPLACED OUTFLOW VALVE ACTUATOR. SYSTEM GROUND CHECKED NORMAL OPS. ACCOMP FUNCTIONAL CHECK/FERRY FLIGHT WITH NO DEFECTS FOUND. SYS OPS CHECKED NORMAL. (M)

More about the Doug DC-9-82