N566JB
Service difficulty reports · 78
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N566JB' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N566JB' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YENA201701100026Seal · damagedCREW EXECUTED AN AIR RETURN AFTER DISCOVERING OIL QTY ON NR 1 ENGINE DROPPED TO 5.5 FROM 18.0 ON CLIMBOUT THROUGH 2,000 FT. LANDED WITHOUT INCIDENT. FOUND EVIDENCE OF OIL LEAK IN DEOILER BREATHER TUBE. FOUND DEOILER SEAL ASSY DAMAGED. R & R DEOILER SEAL ASSYSDR YENA20160918813Shear Plate · corrodedCORROSION ON SHEAR PLATE STRINGER 23R LOCATED FRAMES 69 TO 70 AT AFT GALLEY AREA. REPLACED THE SHEAR PLATE IAW SRM A320-51-72-11 AND DRAWING D53174180SDR YENA20160918815Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y 1292 ON FRAME 64+9 AT AFT GALLEY. REPLACED THE FLOOR SUPPORT BETWEEN FRAMES 64 - 66 IAW SRM 51-72-11 AND DRAWING D53472816.SDR YENA20160918814Structure · corrodedCORROSION ON LOWER SILL, FRAME 66 LEFT SIDE AT AFT GALLEY AREA. REPAIRED IAW SRM 53-41-14-300-001.SDR YENA20160918812Shear Plate · corrodedCORROSION ON SHEAR PLATE STRINGER 23L, FRAMES 69 - 70. REPLACED THE SHEAR PLATE IAW SRM A320-51-72-14 AND DRAWING D53174180.SDR YENA20160918811Web · corrodedCORROSION FOUND ON WEB STRINGER FRAMES 69 - 70 STRINGER 23R AT AFT GALLEY AREA. WEB FOUND TO BE OUT OF LIMITES, REPLACED THE WEB STRINGER IAW 72-11 AND DRAWING D53174180SDR YENA20160918810Floor Support · corrodedCORROSION ON FLOOR SUPPORT Y1292 FRAME 66+2 AT AFT GALLEY AREA. CORROSION WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-41-15 FIG 001 ( SHEET 1) FLOOR SUPPORT REPLACED IAW 51 -72 - 11, AND DWG D53472815.SDR YENA20160918809Web · corrodedCORROSION ON WEB STRINGER LOCATED FRAME 69 STRINGER 23L AT AFT GALLEY AREA. REPLACED WEB STRINGER IAW SRM 51-72-11 AND DRAWING D53174180.SDR YENA20160918808Floorbeam · corrodedCORROSION ON FLOORBEAM Y465 ON FRAME 66+ 1 AT AFT GALLEY AREA. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14 FIG 001 SHEET 1. REPLACED THE FLOORBEAM IAW SRM 51-72-11 AND DRAWING 053472816.SDR YENA20160918807Floorbeam · corrodedCORROSION ON FLOORBEAM Y1292. FOUND TO BE OUT OF LIMITS IAW SRM 53-41-15 FIG 001 SHEET 1. REPLACED FLOORBEAM IAW SRM 51-72-11 AND DRAWING 053472812.SDR YENA20160918806Floorbeam · corrodedCORROSION ON FLOORBEAM Y919 ON FRAME 66+4 AT AFT GALLEY AREA. REPLACED THE FLOORBEAM IAW SRM 51-72-11 AND DRAWING 053472812.SDR YENA20150806328Beam · pulledDURING SPECIAL MAINTENANCE, FOUND DUMMY BEAM CORRODED AT FRAME 16, Y503, REPLACED BEAM IAW REF 51-42-11 AND 53-11-14. THIS ITEM HAS BEEN CLASSIFIED AS A LEVEL 2 CORROSION.SDR YENA20150806327Beam · pulledDURING SPECIAL MAINTENANCE, FOUND DUMMY BEAM CORRODED AT FRAME 16, Y503.2. REPLACED BEAM IAW REF 51-42-11 AND 53-11-14. THIS ITEM HAS BEEN CLASSIFIED AS A LEVEL 2 CORROSION.SDR YENA20141004211Battery Pack · no testDURING MAINTENANCE, FOUND FWD EPSU BATTERY FAILED CAPACITY CHECK AT POSITION 10WL. R & R FORWARD EPSU BATTERY AT POSITION 10WL IAW AMM 33-51-38. BATTERY CAPACITY CHECK OK. EMERGENCY LIGHT SYS TEST OK.SDR YENA20120411473Release Cable · no testFLT 6403, ON HEAVY MAINTENANCE CHECK, FOUND LEFT OVERWING SLIDE RELEASE CABLE FAILED THE OPS CHECK. REPLACED LEFT OVERWING SLIDE RELEASE CABLE AND PERFORMED RIGGING AND OPS CHECKED GOOD IAW TASK CARD A320-53-1227.SDR YENA20120411472Cable · no testFLT 6403, HEAVY MAINTENANCE CHECK, FOUND RIGHT OVERWING SLIDE RELEASE CABLE FAILED THE OPS CHECK. REPLACED RIGHT OVERWING SLIDE RELEASE CABLE AND PERFORMED RIGGING AND OPS CHECKED GOOD IAW TASK CARD A320-53-1227.SDR YENA20111024373Wire · chafedFLT 787 JFK-SXM, AIR TURNBACK DUE TO MULTIPLE CIRCUIT BREAKER / RELAY CYCLES (HEARD AUDIBLY) FOLLOWED BY MULTIPLE ECAM WARNINGS. AUTOMATION FAILURES AND LOSS OF CAPT AND F/O PFD AND ND. ALL SYSTEMS RESTORED AFTER RELAYS STOPPED CYCLING. FOUND WIRE INSULATIOSDR YENA20110218201Idg · failedFLT 453 BOS-FLL, CREW DECLARED EMERGENCY AND AIRCRAFT DIVERTED TO MCO DUE TO SEC 3, FAC 2 FAULTS, F/O SCREENS AND LOWER ECAM WENT DARK AND EVENTUALLY CAME BACK. CABIN LIGHTS ALSO WENT OUT AND FLICKERED. REMOVED AND REPLACED IDG NR 2 AND OPS TEST NORMAL. PERSDR YENA20110214198Unknown · malfunctionedFLT 741 MCO-SJU, AIR TURNBACK TO MCO DUE TO CLIMBING THRU 27000 FT NUMEROUS FAULTS INCLUDING ELACS, SECS AND FACS ALL HAPPENED WITHIN 2 SECONDS THEN FAC 3 FAULT WAS ALL THAT WAS LEFT NO RECOVER OF OTHER FAULTS, DID FAC 3 RESET ALL NORMAL FOR REST OF FLIGHT. ISDR YENA20110213196Gcu · failedFLT 523 EWR-MCO, CREW DECLARED EMERGENCY DUE TO DURING CRUISE ELEC MALFUNCTIONS CAUSED NUMEROUS FAULTS INCLUDING SEC 3, FAC 2, F/O PFD, F/O ND, LWR ECAM, COCKPIT DOOR, CABIN LIGHTING, LIVE TV. ALL OF THESE ITEMS FLICKERED ON/OFF NUMEROUS TIMES. THE ECAM ACTISDR YENA20100207018Battery · failedFLT JB381 LGA-FLL DURING RON MAINTENANCE FOUND CABIN EMERGENCY LIGHTS AT OVERWING DOORS LEFT (11WL) AND RIGHT (12WL) ESPU BATTERIES FAILED EMERGENCY LIGHT TEST. REMOVED AND REPLACED RIGHT AND LEFT EMERGENCY LIGHT BATTERIES IAW AMM 33-51-38, OPS CHECK NORMAL. SDR YENA2007085Battery Pack · failedFWD LEFT EPSU BATTERY FAILED ON EMERGENCY POWER TEST. REMOVED AND REPLACED FWD LEFT EPSU BATTERY PACK IAW AMM 33-51-00, OPS CHECK OK.SDR YENA200603Cooling Fan · inoperativeAFT AVIONICS RACK SMOKE WARNING AFTER CUTOFF/RESET, HAPPENED AGAIN. FOUND COOLING FAN LIGHT ON, LTV SYSTEM PLACED ON MEL 25-22-03. LTV SYSTEM DEACTIVATED DUE COOLING FAN LIGHT ON. REMOVED AND REPLACED COOLING FAN MOTOR. OPS CHECK GOOD, REF LTV MM 23-39-00.SDR YENA200556Cylinder Damper · leakingR1 DOOR ASSIST CYLINDER LEAKING WILL NOT HOLD NITROGEN. REMOVED AND REPLACED R1 DOOR ASSIST CYLINDER PER AMM 52-11-14.SDR YENA200430Cylinder · leakingR1 DOOR DAMPER CYLINDER READS 0 PSI. REMOVED AND REPLACED DOOR DAMPER CYLINDER IAW AMM 52-11-00-000-001 / 52-11-00-400-001.SDR YENA200414Electrical Box · odorELECTRICAL ODOR AROUND ROW 13/14. TURNED OFF LIVE TV SYSTEM. ODOR SUBSIDED. INSPECTED PER INFORMATION NOTICE 2003-T050TRA ROW 11-14 R/L. NO DEFFECTS NOTED. REMOVED AND REPLACED SEB AT 13 RT AS PRECAUTION IAW AMM 23-39-00. OPERATIONS CHECK GOOD AT THIS TISDR 200414Electrical Box · odorELECTRICAL ODOR AROUND ROW 13/14. TURNED OFF LIVE TV SYSTEM. ODOR SUBSIDED. INSPECTED PER INFORMATION NOTICE 2003-T050TRA ROW 11-14 R/L. NO DEFFECTS NOTED. REMOVED AND REPLACED SEB AT 13R AS PRECAUTION IAW AMM 23-39-00. OPERATIONS CHECK GOOD AT THIS TIMESDR YENA200323Smoke · detectedDURING CRUISE AT FL 350 SMOKE WAS NOTICED IN FLT DECK FROM CENTER CONSOLE, EMERGENCY PROCEDURE PERFORMED, SMOKE WAS EVACUATED. NO OTHER SMOKE WAS NOTED. RETURNED TO JFK. EXTENSIVE TROUBLESHOOTING FAILED TO PINPOINT THE SOURCE OF THE SMOKE. ALL TESTS AND GR
Back to N566JB