N57016
Service difficulty reports · 75
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N57016' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N57016' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026100820230Doubler · damagedSTARLINK AEROTERMINAL STRUCTURAL INSTALLATION AT BS 695 STR 1R FOUND AIR DUCT SUPPORT AND FRAME OUTER CHORD SHORT EDGE MARGIN. BS 695 STRINGER 1R STARLINK AEROTERMINAL STRUCTURAL INSTALLATION AIR DUCT HANGER BRACKET INSTALLED IAW ECRA 5330-07837, REV-. FASSDR CALA2026100720189Battery Pack · dischargedTHE MID EMERGENCY LIGHT POWER SUPPLY BATTERY PACK (M33406) FOUND LOW CAPACITY . REPLACED THE BATTERY PACK (M33406) AND CARRIED OUT OPERATION TEST. THE TEST WAS NORMAL IAW AMM 33-51-06-960-803, REV.108.SDR CALA2026100620155Battery Pack · inoperativeGALLEY M1/M2 CENTER PROXIMITY NO POWER. REPLACED L2 M33096 DOOR EMERGENCY LT BATTERY PACK AND INSTALLATION TEST, THE TEST WAS NORMAL. AS PER AMM 33-51-06-960-803 REV.108 AND AMM 33-51-06-960-802 REV.108.SDR CALA2026091419386Unknown · odorREFERENCE 3313128 CONDITIONAL INSPECTION REQUIRED DUE TO SMOKE/ODOR IAW AMM 05-51-58-800-801-C3, COMPLIED WITH THE. SMOKE/ODOR IN THE FLIGHT DECK/CABIN INSPECTION IAW AMM 05-51-58-800-801-C3 PER CREW BREIF ODOR DISAPATED RAPIDLY. ACCOMPLISHED THROUGH STEP C SDR CALA2026091419385Unknown · odorAPPROX 6+50 INTO THE FLIGHT PURSER ADVISED A SMOKE SMELL ROWS 3 /5 PER CREW DEBRIEF SMOKE ODOR DISAPATEDED QUICKLY AND NEVER RETURNED SEE LOG 3314160 FOR FINAL CONDITIONAL INSPECTION COMPLETIONSDR CALA2026072017885Relay · faultedCONDITIONAL INSPECTION REQUIRED FOLLOWING STRONG FUMES IN FLT DECK PLEASE FOLLOW TRM EC0500-01016 PERFORMED SMOKE IN CABIN/FLIGHT DECK INSPECTION IAW AMM 05-51-58-800-801-C3 UP TO STEP 1.C.(2)(L). NO OBVIOUS SOURCE FOR SMOKE FOUND. POWER RAN. DID NOTE BRIEF SDR CALA2026072017898Relay · faultedELEC STBY SYS FAIL AFTR ENG SHUTDOWN STRONG FUMES IN FLTDECK FLIGHT CREW REPORTED SMELL OF SMOKE, TURNED OFF RECIRC FAN TO CLEAR THE SMOKE. CABIN CREW COMPLAINED OF FUME IN THE CABIN. CREW OPENED WINDOW TO CLEAR THE ODOR OF FUME. ELEC STBY SYS STS MSG WITH COSDR CALA2025080507289Carbon Seal · leakingNR 1 ENGINE HAS BEEN TRENDING STABLE AT A HIGH OIL CONSUMPTION (0.65-0.75QPH). ACCOMPLISHED SNIFF CHECK FOR FUEL IN OIL SYSTEM AND BAGGED DRAIN LINES COMING FROM ACCESSORY GEAR BOX FOR PART POWER LEAK IAW FIM 71-05 TASK 805. FOUND IDG CARBON SEAL LEAKING ASDR CALA2025052104882Girt Bar · no discrepancyDOOR 4L GIRT BAR TORQUE TUBE ASSEMBLY REMOVED FOR S/M ACCESS, REF AMM 52-11-17-000-801, SUB TASK 52-11-17-020-005 REINSTALLED MED 4L GIRT BAR TORQUE TUBE ASSEMBLY. REF. AMM SUBTASK 52-11-17-420-004. ACP. INSPECTION OF LH #4 DOOR GIRT BAR TORQUE TUBE ASSY INSTASDR CALA2025031102715Charger · inoperativeB777-33-3-7019-97-30 - CABIN L/H DR 2 M33096 EMER LT BATTERY PACK CHARGER FOUND INOP. CABIN LH DOOR 2 M33096 EMER LIGHT BATTERY AND CHARGER REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2025030500480Battery Pack · inoperativeB777-33-3-7019-97-30 CABIN R/H DR4 M33408 EMER LT BATTERY PACK CHARGER FOUND INOP. CABIN R/H DR4 M3408 EMER LT POWER SUPPLY REPLACED AND TESTED OK AS PER AMM 33-51-06.SDR CALA2025030400473Battery Pack · inoperativeB777-33-3-7019-97-30 - CABIN L/H DR 2 M33096 EMER LT BATTERY PACK CHARGER FOUND INOP. CABIN LH DOOR 2 M33096 EMER LIGHT BATTERY AND CHARGER REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2025030400472Battery Pack · inoperativeB777-33-3-7028-85-30-00 - CABIN OHAR M9073 EMER LT BATTERY PACK CHARGER FOUND INOP TRANSFER REF HXWO 4442007 AND ORIGINATED BY EMP V926672 CABIN OHAR M9073 EMER LIGHT BATTERY AND CHARGER REPLACED AND TEST NORMAL AS PER AMM 33-51-15 AND AMM33-51-06 WORK ACCOMPLSDR CALA2025013002132Warning Light · false indicationDOOR FLIGHT LOCK 1R EICAS STATUS #1 RIGHT PASSENGER ENTRY DOOR FLIGHT LOCK COMMAND/FLT LK RLY/SEN SOR DISAGREEMENT. PSEU 2 (R2) CREW INDICATED 1R DOOR FLIGHT LOCK STATUS DISAGREEMENT MESSAGE DURING FLIGHT. CYCLED DOOR 1R WITH NO FAULTS SHOWN. THERE ARE NO ACSDR CALA2025013002137Actuator · faultedDOOR FLIGHT LOCK 1R EICAS STATUS #1 RIGHT PASSENGER ENTRY DOOR FLIGHT LOCK COMMAND/FLT LK RLY/SEN SOR DISAGREEMENT. . DOOR OPEN AND CLOSE OK PER MEL. ITEM DEF PER MEL. TOMC APPROVES MEL 5211E DOOR 1R FLIGHT LOCK INOP ITEM DEF PERFORMED FIM 52-11 TASK 806 AND FSDR CALA2024111901184Charger · faultedALL FLOR PROXIMITY EMERGENCY LIGHTS (15EA) OF GALLEY COMPLEX DOOR 2 INOPERATIVE. CONFIRMED FAILURE OF EMERGENCY POWER SUPPLY CHARGER ASSY OF POSITION M33096. REPLACED CHARGER ASSY, OPERATIONAL TEST OK. REF AMM TASK 33-51-06-960-803. PN IN/OUT: D717-02-030, SN SDR CALA2024111901179Sign · inoperativeEMERGENCY LIGHTS - EXIT IDENTIFIER LH OF DOOR 2L INOPERATIVE. CONFIRMED FAILURE OF EMERGENCY POWER SUPPLY CHARGER ASSY OF POSITION M33099. REPLACED CHARGER ASSY, OPERATIONAL TEST OK. REF AMM TASK 33-51-06-960-803. PN IN/OUT: D717-02-030, SN OUT: 10768, SN IN: SDR CALA2024102800939Blower · faultedLAVS 2L 2R 3R 3C 4L WILL NOT FLUSH PLACED ITEM ON MEL FOR CENTER WASTE TANK. DISPATCH DESK: 60 .NAME: PP.DATE: 25-OCT-24. APPROVED PLACED ITEM ON MEL. LAV FLUSHES NORMALY ON GROUND. R&R VACUUM BLOWER SYSTEM #2 RLY (K38201), REF: FIM 38-30 TASK 818, AND R&R VACSDR CALA2024110102762Relay · inoperativeAFTER BOTH ENG START REC IVED PITOT HEAT L AND NO LAND 3 EICAS. TASK 30-31-00-700-802 AGAIN, TEST PASSED. PITOT HEAT L AND NO LAND 3 EICAS MESSAGES DO NOT SHOW. T/S SYSTEM PER SSM 30-31-11-102 SUSPECT RELAY K30120 OR ADM PERFORMED FIM 30-31 TASK 801, FOUND MAISDR CALA2024082000465Transceiver · faultyWXR SYS EICAS STATUS WXR DISPLAY IS NOT PRESENT WHEN WXR SELECTED ON EFIS CONTROL PAN EL. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 3189115 FLIGHT STATUS: I INTERMITTENCE CODE: I PH: CRUISE NARRATIVE: DISPLAYS-2 IN LEFT AIMS CMC MSG# 3189113 FLIGSDR CALA2024060501701Gcu · warning messageELEC GEN SYS L EICAS STATUS IDG HAS DISCONNECTED OR A PROTECTIVE TRIP OF THE GENERATOR CONTR OL BREAKER HAS OCCURRED OR A PROTECTIVE TRIP OF THE BTB HAS OCCU RRED. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 2431761 FLIGHT STATUS: L INTERMITTENCE CODSDR CALA2024060401691Gcu · failedELEC GEN SYS L EICAS STATUS IDG HAS DISCONNECTED OR A PROTECTIVE TRIP OF THE GENERATOR CONTR OL BREAKER HAS OCCURRED OR A PROTECTIVE TRIP OF THE BTB HAS OCCU RRED. RESET PER ECL RESET SUCCESSFUL DEBRIEFED FLT CREW LEFT IDG DISCONNECTED 2 HRS INTO FLIGHT ACCOMPSDR CALA2024050301309Unknown · odorSMOKE & BURNING SMELL FOUND DURING CABIN ETOPS CHECKS AROUND DOOR 2 AREA CEILING PANELS DROPPED IN POLARIS. NO OBVIOUS WIRING ISSUES GOOD, DOOR HEATER LRU REPL TEST PASSED. REF SSM 21-60-00-101. POWER PANELS CHECKED DURING CB LOCKOUTS, NO ABNORMAL CB NOTED AT SDR CALA2024050601313Hinge · brokenAIRCRAFT (EXTERNAL) INSPECT {B777-06-3-7157} - RT FUSELAGE PANEL 192LR HAS BROKEN HINGE. SEE PHOTO ADDED PART #S. ADDED PART #S. ADDED PART #S. R&R RIGHT SIDE HINGE ON PANEL 192LR AND PAINTED IAW 53-36-02SDR CALA2023122203714Battery · no testB777-33-3-7019 DR L3 M33406 EMER LIGHT BATTERY CAPACITY CHECK FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.2630390. DR L3 M33406 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2023122203713Battery · no testB777-33-3-7019 DR R3 M33401 EMER LIGHT BATTERY CAPACITY CHECK FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.2630385. DR R3 M33401 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2023122203712Battery · no testB777-33-3-7019 DR R4 M33409 EMER LIGHT BATTERY CHARGER TEST FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.2630397. DR R4 M33409 EMER LIGHT BATTERY CHARGER REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2023122203711Battery · no testDOOR L2 EMER LIGHT BATTERY M33096 CAPACITY CHECK FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.2629060. DR L2 EMER LIGHT BATTERY M33096 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2023122203710Battery · no testB777-33-3-7019, DR R4 EMER LIGHT BATTERY M33409 CAPACITY CHECK FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.2629097. DR R4 EMER LIGHT BATTERY M33409 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2023042401231Ballast · overtempELECTRICAL BURNING SMELL NOTICED ON FINAL FORWARD GALLEY LIGHT BALLAST REPLACED IAW M.M TASK 33-22-03-960-802. MM 05-51-58-800-801-C3 INSPECTION CARRIED OUT. MEC, GALLEY, FLIGHT CREW REST AREA, FLIGHT DECK AND FWD CABIN AREA. ONLY EVIDENCE OF ELECTRICAL BURNISDR CALA2023021300415Charger · inoperative1EA EXTERNAL EMERGENCY LIGHT LOCATED AT RH DR4 FOUND INOPERATIVE REF HAECO NON-ROUTINE NO.9405544 - ORIGINATED BY EMP V905457 SPEC NO.B777-33-3-7020. PERFORMED BY EMP V903689, IDT BY EMP V905344. REPLACED R/H DR4 EMER LT LAMP AND M33049 POWER SUPPLY,THE RESULTSDR CALA2022050401136None · failedB777-33-3-7019 DR L3 EMER LT PWR PACK BATTERY M33406 CAPACITY CH ECK FAILED TRANSFER REF NON-ROUTINE HX WO.694968 AND ORIGINATED BY V920592 DR L3 EMER LT POWER PACK BATTERY M33406 RERALED AND INSTALLATION TEST CARRIED OUT NORMAL IAW AMM 33-51-06 WORK ACCOMPLISSDR CALA2022050401135None · failedSUPPORT TASK: DR L4 EMER PWR SUPPLY (M33407) BATT FUNCTIONAL FAI L TRANSFER REF HX NON-ROUTINE WO.764220 AND ORIGINATED BY V92059 1 DR L4 EMER PWR SUPPLY (M33407) BATTERY REPLACED & TEST OKAY IAW AMM 33-51-06 WORK ACCOMPLISHED BY MECHANIC V920591 INSPECTED BY SDR CALA2022050401134None · failedB777-33-3-7019 L1 DR EMERGENCY LT POWER PACK BATTERY M33093 CAPA CITY CHECK FAILED TRANSFER REF HX NON-ROUTINE WO. 694956 AND ORI GINATED BY V920584 L1 DOOR EMER LT POWER PACK BATTERY M33093 REPLACED AND INSTALLATION TEST CARRIED OUT NORMAL IAW AMM 33-51-06 WOSDR CALA2022050401133None · failedB777-33-3-2019 DR L3 EMER LT PWR PACK BATTERY M33400 CAPACITY CH ECK FAILED TRANSFER REF HX NON-ROUTINE WO.694930 AND ORIGINATED BY V920592 DOOR L3 EMER LT POWER PACK BATTERY M33400 REPLACED AND INSTALLATION TEST CARRIED OUT NORMAL IAW AMM 33-51-06 WORK ACCOMPSDR CALA2022042101047Fitting · crackedAD 2013-08-02 SUPPORT TASK EA 5510-01896 REV C OP 005 1EA CRACK WAS FOUND ON LH ELEVATOR O/B ACTUATOR FITTING APPROX 2 3/4 IN LENGTH ATRADIUS AREA AS MARKED. PLS PRINT & ACCOMPLISH OP 09 OF THS EA. TRANSFER REF.NON-ROUTINE HX NRC WO.699257 AND ORIGINATED BY EMSDR CALA2021012500091Battery · no testB777-33-3-7019 M33093 EMERGENCY POWER SUPPLY DEEP CYCLE TEST FAILED. EMERGENCY POWER SUPPLY BATTERY REPLACED AND TESTED NORMAL, AS PER AMM 33-51-06.SDR CALA2021012500090Battery · failedB777-33-3-7019 M33094 EMERGENCY POWER SUPPLY DEEP CYCLE TEST FAILED EMERGENCY POWER SUPPLY BATTERY REPLACED AND TESTED NORMAL, AS PER AMM 33-51-06.SDR CALA2021012500089Battery · failedB777-33-3-7019 M33096 EMERGENCY POWER SUPPLY DEEP CYCLE TEST FAILED EMERGENCY POWER SUPPLY BATTERY AND CHARGER REPLACED AND TESTED NORMAL, AS PER AMM 33-51-06.SDR CALA2021012500088Battery Pack · failedB777-33-3-7019 - M33404 EMERGENCY POWER SUPPLY DEEP CYCLE TEST FAILED EMERGENCY POWER SUPPLY BATTERY AND CHARGER REPLACED AND TESTED NORMAL, AS PER AMM 33-51-06.SDR CALA2021012500087Charger · failedB777-33-3-7019 M33409 EMERGENCY POWER SUPPLY DEEP CYCLE TEST FAILED EMERGENCY POWER SUPPLY BATTERY AND CHARGER REPLACED AND TESTED NORMAL, AS PER AMM 33-51-06.SDR CALA2019061400948Lamp · burned outSUPPORT TASK - OHAR EMER. LIGHT 1EA FOUND INOP REF L/P 9131701 OHAR EMER. LIGHT LAMP 1EA REPLACED AND TESTED NORMAL AS PER AMM 33-51-15 ADD EMP:V896958 IDT OKSDR CALA2019061400934Battery · dischargedSUPPORT TASK: B777-33-3-0018 DR L2 EMER LIGHT POWER SUPPLY M3309 9 BATTERY PACK CAPACITY LOW, REFER NR LP 9130227. DR L2 EMER LIGHT POWER SUPPLY M33099 BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2019061400933Battery · dischargedSUPPORT TASK: B777-33-3-0018 DR L3 EMER LIGHT POWER SUPPLY M3340 5 BATTERY PACK CAPACITY LOW, REFER NR LP 9130226. DR L3 EMER LIGHT POWER SUPPLY M33405 BATTERY REPLACED AND TESTED NORMAL AS PER AMM33-51-06.SDR CALA2019061400932Battery · dischargedSUPPORT TASK : B777-33-3-0018 DR R3 EMER LIGHT POWER SUPPLY M334 04 BATTERY PACK CAPACITY LOW, REFER NR LP 9130225. DR R3 EMER LIGHT POWER SUPPLY M33404 BATTERY REPLACED AND TESTED NORMAL AS PER AMM33-51-06.SDR CALA2019061400931Battery · dischargedDR R4 EMER LIGHT POWER SUPPLY M3340 8 BATTERY PACK CAPACITY LOW, REFER NR LP 9130224. DR R4 EMER LIGHT POWER SUPPLY M33408 BATTERY REPLACED AND TESTED NORMAL AS PER AMM33-51-06.SDR CALA2019061400930Battery · dischargedSUPPORT TASK: B777-33-3-0018 DR L4 EMER LIGHT POWER SUPPLY M3340 7 BATTERY PACK CAPACITY LOW, REFER NR LP 9130223. DR L4 EMER LIGHT POWER SUPPLY M33407 BATTERY AND CHARGER REPLACE D AND TESTED NORMAL AS PER AMM33-51-06.SDR CALA2019061400929Battery · dischargedSUPPORT TASK: B777-33-3-0018 DR L4 EMER LIGHT POWER SUPPLY M3340 7 BATTERY PACK CAPACITY LOW, REFER NR LP 9130223. DR L4 EMER LIGHT POWER SUPPLY M33407 BATTERY AND CHARGER REPLACE D AND TESTED NORMAL AS PER AMM33-51-06. ADD EMP:V896958 INSPECTED BY HX248973.SDR CALA2019061400928Battery · dischargedSUPPORT TASK: B777-33-3-0018 OHAR EMER LIGHT POWER SUPPLY M9073 BATTERY PACK CAPACITY LOW, REFER NR LP 9130222. OHAR EMER LIGHT POWER SUPPLY M9073 BATTERY AND CHARGER REPLACED AND TESTED NORMAL AS PER AMM33-51-06.SDR CALA2018120702500Power Supply · malfunctionedCHK FND L1 DOOR SIDE AND CEILING MOUNTED EMER LT AND ZONE A FURNITURE MOUNTED FLOOR PROXIMITY LT NOT ILLUM REF SSM 33-51-12 SHEET 1 AND AMM 33-51-06 M39003 EMERGENCY LIGHT POWER SUPPLY CHARGER AND BATT PACK REPLACED AND TEST SATIS REF SSM 33-51-12 SHEET 1 AND
Back to N57016