N590NW
Service difficulty reports · 176
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N590NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N590NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA14011555810Skin · damagedLIGHTNING STRIKE AT BS 780 AND S22L. REPAIRED IAW SRM 53-00-01. RESTORED FINISH IAW SRM 51-20.SDR DALA14011545810Skin · damagedTWO LIGHTNING STRIKES AT BS 680 AND S24L REPAIRED IAW SRM 53-00-01. RESTORED FINISH IAW SRM 51-20.SDR DALA14011535810Skin · damagedLIGHTNING STRIKE AT BS 729, S52L REPAIRED IAW SRM 53-00-01. RESTORED FINISH IAW SRM 51-20.SDR DALA13041925810Wire · damagedON SERVICE CHECK, FOUND EMERGENCY LIGHTS INOPERATIVE AT ROWS 31-36. TROUBLESHOT SYSTEM & FOUND WIRE DAMAGED AT SPLICE AT ROW 36. REPAIRED WIRING. OPS NORMAL.SDR DALA13024745810Bulb · inoperativeEXIT LIGHT ABOVE DOORS HAVE BULBS INOPERATIVE. REPLACED LAMP, OPS NORMAL.SDR DALA13024735810Bulb · inoperativeEMERGENCY LIGHTS OVER WING DOORS HAVE SEVERAL LIGHT BULBS INOP. REPLACED LAMPS, OPS CHECKED NORMAL.SDR DALA13014555810Wire · brokenSEAT MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE FORM 26ABC TO 30ABC. FOUND BROKEN WIRE SPLICE FWD OF SEAT 25A. REPAIRED SAME IAW BSP WIRE 20-30.SDR DALA13011685810Skin · scratchedSCRATCH ON UPPER R1 DOOR 8 INCHES BELOW THRESHOLD. SCRATCH IS WITHIN SRM LIMITS SRM 53-00-01. BURNISHED AND TREATED AREA WITH ALODINE.SDR DALA13007435810Structure · gougedAFT CARGO DOOR HAS SMALL GOUGE 13 INCHES LOWER AFT EDGE ON LOWER LIP. REPAIRED DAMAGE IAW SRM 52-30-01.SDR DALA13001005810Skin · scratchedDURING SERVICE CHECK, NOTED SCRATCH IN RVSM AREA OF RT AUX STATIC PORT. EVALUATED SCRATCH IAW SRM 51-10-01 AND 53-00-01 & PERFORMED SCRATCH CLEANOUT, FINAL SKIN THICKNESS IS WITHIN LIMITS.SDR DALA12009665810Strap · crackedMX DISCOVERED THE FLOORBEAM TENSION STRAP CRACKED IN 2 PLACES AT STA 365.25 AND 371, LBL 24.75. REMOVE DOUBLER AND TRIM CRACKED EDGE. PERFORM HFEC, FABRICATE REPAIR, AND TREAT AREA - REF ER/A 506553-14, REV ORIGINAL.SDR DALA1231845810Light · damagedDURING INSPECTION IT WAS DISCOVERED THAT SEAT 26C HAS ONE EMERGENCY PATH LIGHT RED MODULES LENS MISSING AND LAMPS BROKEN. REMOVED AND REPLACED EMERGENCY PATH LIGHT ASSY AT SEAT 26C, OPERATES NORMALLY.SDR DALA1131965810Skin · damagedFWD CARGO DOOR FRAME SKIN DAMAGED AT STA 620 STGR 24 TRIMMED OUT DAMAGE. NEEDS HFEC 141236, PERFORMED HFEC PER NDT MANUAL PART 6 51-00-01. ALL DAMAGE REMOVED. 97579, PERFORMED HFEC OF FASTENER HOLES PER PART 6 51-00-16 OF NDT MANUAL. NO FAULTS. FABRICATED DSDR DALA1052965810Lamp · inoperativeBOTH RT OFFWING ESCAPE EMERGENCY LIGHTS INOPERATIVE. RELAMPED LIGHTS IAW AMM.SDR DALA1025795810Skin · puncturedDURING "L" CHECK FOUND PUNCTURE IN UPPER SKIN OF LT WING T/E INBD AFT FLAP. REPAIRED IAW SRM 51-70-17 3F, 3G, 4B, PAGES 16-55, FIG 24.SDR DALA1025785810Skin · dentedDURING "L" CHECK FOUND 2 DENTS IN FUSELAGE SKIN BETWEEN BS 600 AND BS 620 AT STRINGER 16L. REPAIRED IAW ERA 486172-14 SECTION I. SECTION II REQUIRES PERMANENT REPAIR BY 06 OCT 2011.SDR DALA12009415810Skin · damagedDURING LIGHTNING STRIKE INSPECTION MX DISCOVERED DAMAGE AT BS 600, STRINGER 22. REMOVED DAMAGED FASTENER REF SRM 51-40-02. PERFORMED HFEC - NO FAULTS NOTED. INSTALLED FASTENER AND TREATED IAW SRM 53-00-01.SDR DALA12009395810Skin · damagedDURING A LIGHTNING STRIKE INSPECTION MX DISCOVERED DAMAGE AT BS 270 BETWEEN STRINGER 17-18. REMOVED DAMAGE FASTENER, CLEANED DAMAGED AREA, INSPECTED-NO FAULTS NOTED. INSTALLED FASTENER AND TREATED IAW SRM 53-00-01.SDR DALA12009405810Skin · damagedDURING LIGHTNING STRIKE INSPECTION MX DISCOVERED DAMAGE AT BS 650, STRINGER 21. REMOVED DAMAGE FASTENER REF SRM 51-40-02. PERFORMED HFEC INSP-NO CRACKS NOTED. INSTALLED FASTENER AND TREATED AREA IAW SRM 53-00-01.SDR NWAA084865810Power Supply · inoperativeDURING AN OVERNIGHT LINE CHECK THE LT OVER WING SLIDE ILLUMINATION LIGHT WOULD NOT TEST. MX FOUND POWER SUPPLY M11383 TO BE DEFECTIVE AND REPLACED IT. OPS WAS NORMAL AFTER REPLACEMENT OF THE BATTERY PACK.SDR NWAA084325810Battery Pack · inoperativeDURING AN OVERNIGHT LINE CHECK THE LT FORWARD EMERGENCY EXIT SIGN WAS INOPERATIVE. MX ATTEMPTED TO REPLACE THE ASSOCIATED BATTERY PACK, BUT THE PROBLEM REMAINED. REPLACEMENT OF THE POWER SUPPLY MODULE FOR THE AFFECTED BATTERY PACK CORRECTED THE PROBLEM. ALLSDR NWAA083795810Sign · inoperativeDURING OVERNIGHT MAINTENANCE THE LT OVERWING EMERGENCY EXIT SIGN AND BOTH FORWARD AND AFT SLIDE HANDLE LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE ASSOCIATED POWER SUPPLY M11487. ALL OPERATIONS CHECKED GOOD. (S)SDR NWAA073305810Battery · inoperativeDURING OVERNIGHT CHECK, BATTERY TEST FOUND 4 BATTERIES NOT RUNNING LONGER THAN TEN MINUTES. MAINTENANCE REMOVED AND REPLACED 4 EMERGENCY BATTERIES. OPERATIONAL CHECK GOOD AND AIRCRAFT HAS RETURNED TO SERVICE.SDR NWAA073295810Connector · crossedDURING FLIGHT HAD UNUSUAL SMOKE LIKE ODOR REPORTED IN MOST OF THE CABIN. MAINTENANCE FOUND CONNECTORS WERE CROSS MATED AND NR 15 MALE PIN ON THE OVEN SIDE WAS BURNT. REMOVED AND REPLACED OVEN AND OPERATIONAL CHECKED GOOD. AIRCRAFT HAS RETURNED TO SERVICE.SDR 0600335810Fan · failedAT 95 MILES FROM MSP RECEIVED -EQUIP OVERHEAT LIGHT-, ASSOCIATED EICAS MESSAGE AND SMELLED STRONG ELECTRICAL SMOKE. DON OXYGEN MASKS, DECLARED AN EMERGENCY AND LANDING WAS UNEVENTFUL. FOUND NR 1 COOLING FAN CIRCUIT BREAKER TRIPPED AND FAN WAS REPLACED. CHECKSDR 0401755810Fuel Line · chafedTHE FUEL SUPPLY TUBE IN THE RIGHT PYLON WAS FOUND TO BE CHAFING AGAINST THE PYLON SUPPORT STRUCTURE (P/N 112N4115-6). THE DAMAGE TO THE FUEL TUBE EXCEEDED THE ALLOWABLE 0.004 INCH OF DAMAGE. REPLACED THE FUEL LINE. REPAIRED PER EO 2822-01068-01. OPERATIONA
Back to N590NW