N602AE
Service difficulty reports · 179
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N602AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N602AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2021102500522None · noneAFTER TAKEOFF DURING CLIMB OUT ENG #1 FIRE MESSAGE APPEARED ON EICAS AND FIRE EXTINGUISHING HANDLE ILLUMINATED. RAN QRH, PULLED EXTINGUISHING HANDLE, BLEW BOTTLE "A". REMOVED AND REPLACED ENG. #1 FIRE BOTTLE IAW EMB-145 AMM 26-21-02. FOUND UPPER CUSTOMER SERVISDR HNAA2021082400389Wire Harness · damagedAPU GEN OVERLOAD. MAX OBSERVED AMPS 660. C/W FIM 24-34-00-810-803-A. INSP APU SHUNT FOR ANY OVERHEATING/BURNING AND REPLACE/REPAIR AS NEEDED. WORK COMPLETED. DEFECTS NOTED. SEE LP# 258484 SEQ1 FOR DISCREPANCY. NO FIX CLOSE WORKING MEL. REQUIRES HARNESS W315SDR HNAA2021072800347Relay · faultedTAT 2 HEAT INOP ON EICAS IN FLT WITH NO ICING. TROUBLESHOT AND MEG WIRE W102-3812, W102-3814-OK,W102-3815,FOUND HIGH RESISTANCE @ WIRE W102-3817 FROM K0496 RELAY A3 TO A1 AT K0494. AND MORE XK0494 RELAY BASE BLOCK SHORTED TO GROUND. R/R BASE CCN 1240168 ALSO SDR HNAA2021070600313Battery Pack · inoperativeROW 1 EMERGENCY FLOOR PATH LIGHTS AND SERVICE DOOR EMERGENCY LIGHT IS INOP. R&R OLD EMERGENCY BATTERY PACK IN THE #2 POSITION WITH A NEW ONE IAW EMB 145 AMM 33-50-04. P/N ON BATTERY PACK 2013-1A S/N 115028 P/N OFF BATTERY PACK 2013-1ASMI S/N 75689.SDR HNAA2021061400262Acm · fumesON DESCENT AT 24K FT FUMES NOTICED IN COCKPIT. FOLLOWED QRH, TURNED OFF GASPER, RECIRC, AND WINDSHIELD HEAT. SMELL SEEMED TO DISSIPATE. ON GROUND RESIDUAL SMELL REMAINED. FIRE CREW NOTED C/B E28 BAGGAGE RECIRC HOT. PERFORMED OPS CHECK OF BAG BAY VENTILATIONSDR HNAA2021041400154Switch · odorPDIS 602 05-00 14APR21 MDT, CLOSE STRONG ODOR IN BAGGAGE COMPARTMENT. FACT 14APR21 10:01 MDT, AFTER AIR OF COMPARTMENT NO ODOR NOTICED. SUSPECT LUBING OF BAG DOOR SWITCH DURING OVERNIGHT MTC.SDR HNAA2021031500096Unknown · odorPDIS 602 21-01 2179641 13MAR21 ORD CLOSE
FUMES SMELLED IN FLIGHT DECK DURING TAXI TO GATE
FACT 13MAR21 20:49 ORD
INSPECTED BOTH PACK SYSTEMS FOR ANY OBVIOUS DEFECTS. NO DEFECTS FOUND. PERFORMED OPS CHECK OF BOTH SYSTEMS WITH CRSDR HNAA2021031600099Button · faultedMAIN PITCH TRIM INOPERATIVE EICAS MESSAGE DURING CRUISE FLIGHT WITH OUT SELECTING A CHANGE OF TRIM AND A/P ON FO'S SIDE. T/S IN REF TO FIM TASK 27 43 00 STEPS 1-4/10-11. FOUND CONTINUITY DEFECT ON PUSH BUTTON MAIN CUTOUT. R & R THE PUSH BUTTON IAW AMM 20 13 0SDR HNAA2021031600098Control Unit · failedMAIN PITCH TRIM INOP EICAS MESSAGE IN CRUISE FLIGHT WITHOUT SELECTING A CHANGE OF TRIM AND A/P ON FO'S. T/S FOUND HOR STAB CTL UNIT FAILURE TWICE ON MFD, R&R STAB CTL UNIT IAW EMB 145 AMM 27-40-01 NO FIX. REMOVED PANEL 324EL CLEANED CP'S ON STAB ACTUATOR AS RSDR HNAA2021021500054Warning Message · illuminated602 HAD AN ABORTED TAKE OFF FOR AN ADVISORY ICE CONDITION MSG AND TAKEOFF CONFIG MSG. NO CMC MESSAGES AND NO HISTORY... DID AN ELECTRICAL ICE PROTECTION TEST.SDR HNAA2020102600291Inverter · inoperativeDISCREPANCY: INTERIOR REAR EXIT LOCATOR LIGHT INOPERABLE (EMERGENCY LIGHT). ACTION TAKEN: REMOVED HEADLINER PANEL IN REF TO AMM TASK 25-22-04-000-802-A. IN ORDER TO GET ACCESS TO EMERGENCY LIGHT INVERTERS. DISCONNECTED AND RECONNECTED NR 5 EMERGENCY LIGHT ISDR HNAA2020022800083Control Unit · malfunctionedSPOILER FAILED MSG IN FLT WITH SPOILERS DOWN MSG CLEARED W/GEAR DOWN. MSG RETURNED WITH LANDING AND SPOILERS DEPLOYED. CMC MSG,S GND SPOILER ENG FAULT AND GROUND SPOILER WHL SPD CKT FAULT....FIX: R&RD SCU IAW EMB 145 AMM 27-63-02. OPS CHECK SAT. OK FOR SERVICESDR HNAA2019112700369Warning Message · false activationPACK 1 OVRHEAT MESSAGE URING T/O ROLL.#2 PACK ON MEL....FIX: GROUND RAN A/C WITH BOTH ENGINES,OPS CK #1 PACK IAW EMB 145 21-51-00 OPS CK GOOD NO OBVIOUS DEFECTS NOTED,OK FOR SERVICESDR HNAA2019110800351Inverter · inoperativeROW 12 CEILING EMERGENCY EXI LIGHT INOP....FIX: R&RD #4 INVERTER IAW 33-50-11-000-801-A AND 33-50-11-400-801-A. OPS CHECK GOODSDR HNAA2019102500321Light · inoperativeEMERGENCY CEILING LIGHT BY SEAT 12 WILL NOT TURN ON....FIX: REMOVED CEILING PNL AT ROW 12INSTALLED NEW LIGHT, REINSTALLED CEILING PNL IAW AMM33-50-15. OPS CHECK GOOD. OK FOR SERVICESDR HNAA2019091600274Light · inoperativeNDIS 602 33-50 0024580 14SEP19 SBY CLOSE EMERGENCY FLOOR LIGHT STRIP BETWEEN ROWS 6 & 7 IS INOP. FACT 14SEP19 14:42 SBY. R&R EMERGENCY FLOOR LIGHT STRIP BETWEEN ROWS 6 & 7 IAW AMM 33-50-12. P/N ON LIGHT STRIP 1013194 P/N OFF LIGHT STRIP 1013194.SDR HNAA2019062000176Wire · brokenAFT PORTION OF OVER-WING EMERGENCY EXIT LIGHT DOES NOT ILLUMINATE....FIX:FOUND BROKEN WIRE W200-8508-20,CRIMPED NEW CONTACT AND CONNECTOR IAW 20-21-00. INSTALLED PANEL OPS CHECK GOODSDR HNAA2019021300044Fan · failedPDIS 602 05-50 1874192 11FEB19 PGV CLOSE
ELECTRICAL SMELL/ODOR COMING FROM FLIGHT DECK CAPTAINS SIDE.
FACT 11FEB19 00:30 PGV
INSP SMELL IN FLT DECK FOUND NO OBVIOUS DEFECTS AT SUSPECT AREA OF FWD GLARESHILED. INSPECTED SUSPECT SDR HNAA2019020800038Warning Message · false activationPDIS 602 30-10 1874141 06FEB19 SYR CLOSE
ICE COND-A/ICE MESSAGE APPEARED DURING TAKEOFF ROLL.
MSG EXTINGUISHED
FACT 06FEB19 16:56 SYR
PERFORMED ELECTRICAL RESET. OPS CHECKED A/ICE SYS IA
W AMM 30-00-00-700-SDR HNAA2019012100021Terminal · not seatedDISCREPANCY: EMERGENCY FLOOR LIGHTS ROW 2 AND 3 INOP. CORRECTIVE ACTION: RESEATED TERMINAL ENDS ON EMERG. FLOOR LIGHT ROW 2, RESECURED LIGHT STRIP WITH RETAINED HARDWARE.SDR HNAA2018123100334Battery · dischargedDIS 602 33-51 0018450 31DEC18 SBY CLOSE LT AND RT OVERWING EMERGENCY EXIT LIGHTS INOP. FACT 31DEC18 10:52 SBY R&R BOTH LT AND RT OVER WING EMERGENCY EXIT LIGHT LAMPS IAW AMM 33-50-10, NO FIX R&R NR 3 BATTERY AND POWER SUPPLY IAW AMM 33-50-04-04, PART INSTALLEDSDR HNAA2018121800317Wire · brokenMDIS 602 33-51 1978093 16DEC18 CLT ASSGN
EMERGENCY LIGHT AT AFT GALLEY WALL HAS BROKEN WIRE A
T SPLICE.
26390 00 DS
HISTORY: .
DFRL 16DEC18 13:40 CLT
INSTALLED TSDR HNAA2018121800319Battery Pack · inoperativeMDIS 602 33-51 1978082 15DEC18 CLT CLOSE
L/H AND R/H EXTERIOR OVERWING EMERGENCY LIGHTS INOP
FACT 16DEC18 11:56 CLT
R\R EMERGENCY BATTERY PACK AT ROW 15A OPS CHECK GOOD
, OK FOR SERVICE. CLEAR MEL.SDR HNAA2018101100253Pressure Switch · malfunctionedAT 400 FEET AGL AT TAKEOFF YD FAILED AND RUD SYS 1/2 INOP CAUTION MSG PRESENTED. RAN QRH WHEN RUD SYS 2 DESELECTED RUD SYS 1 CAME BACK ON LINE. YD RE-ENGAGE AND IT STAYED ONLINE. T/S IN REF TO FIM 27-22-00-810-804-A FOUND RUD SYS 2 PRESS SW FAIL. R&R RUD SYSTESDR HNAA2018091100218Processor · malfunctionedATC REPORTS BOTH TRANSPONDERS FAIL INFLIGHT -WILL NOT IDENT-. R&R TCAS PROCESSOR IAW AMM 34-43-01. OPS CHECK IAW AMM 34-43-00 REQUIRES FUNCTIONAL CHECK.SDR HNAA2018071300148Door · missingRIGHT AFT FUSELAGE IS MISSING APU ACCESS DOOR AFTER FLIGHT.SDR HNAA2018052500109Actuator · leakingDURING FLIGHT, NOTICED A RAPID DEPETION OF THE NR 1 HYD SYSTEM QUANTITY WITH AN EICAS MESSAGE. R & R GROUND SPOILER ACTUATOR IAW AMM 27-62-01-400-801-A. REPLENISHED TH EHYDRAULIC SYSTEM.SDR HNAA2018050200095Valve · failedNR 2 HIGH STAGE VALVE FAILURE DURING TAKE OFF AT ABOUT 20 KNOTS. R&R NR 2 HIGH STAGE VALVE IAW AMM 36-11-02. OPS GOOD AT THIS TIME. OK FOR SERVICE.SDR HNAA2018042500087Connector · dirtySEAT 12A EXIT SIGN INOPERATIVE. CLEANED CONNECTORS AND SECURED IAW AMM 33-50-14-0001/400-801-A. OPS CHECKED GOOD.SDR HNAA2018041100081Wire · damagedLEFT OVERWING EMERGENCY LIGHT INOPERATIVE. SECURED THE LIGHT WIRES IAW 20-21-00.SDR HNAA2018033000078Light · unknownFLOOR EMERGENCY LIGHT STRIP, SEAT 1A INOPERATIVE. PERFORMED AN OPS CHECK OF THE EMERGENCY LIGHT. OPS CHECKED NORMAL. OK FOR SERVICE.
E.SDR HNAA2017101600349Inverter · inoperativeLEFT AFT INTERIOR OVERWING EMERGENCY EXIT SIGN WILL NOT ILLUMINATE. R & R THE INVERTER IAW AMM 33-50-11-000/400-801A. OPS CHECKED GOOD. OK FOR SERVICE.SDR HNAA2017092900334Contact · dirtyEMERGENCY LIGHT AT ROW 12A, AFT WINDOW DOES NOT ILLUMINATE. REMOVED THE EMERGENCY LIGHT. CLEANED THE CONTACTORS, AND INSTALLED THE LIGHT. OK FOR SERVICE. OPS CHECKED SATISFACTORY IAW AMM 33-50-14-000/400-801A.SDR HNAA2017052900194Relay · inoperativePITOT NR 3 INOPERATIVE CAUTION EICAS MESSAGE. R & R THE RELAYS K0058 & K0060 IAW TASK 30-31-00-810-803-A. OPS GOOD.SDR SIMA20161216007Door Sill · corrodedCARGO DOOR SILL IS CORRODED. R & R THE DOOR SILL IAW SRM 51-40-02.SDR SIMA20161216003Shear Tie · corrodedFRAME 65 SHEAR TIE CORRODED. INSTALLED A REPAIR IAW SRM 53-31-04.SDR SIMA20161216004Support · corrodedTOILET WASTE VALVE SUPPORT IS CORRODED. PERFORMED PERMANENT REPAIR INSTALLED DOUBLER IAW ERS-EM-53MR-2471.SDR SIMA20161216005Door Sill · corrodedCARGO DOOR SILL IS CORRODED. R & R THE DOOR SILL IAW SRM 51-40-02.SDR SIMA20161216009Stringer · chafedSTRINGER 19R BETWEEN FRAMES 52-53 CHAFED. REPAIRED THE STRINGER IAW SRM 53-24-02.SDR SIMA20161216008Frame · brokenFRAME 10 UNDER COPILOTS WINDOW IS BROKEN. REMOVE AND REPLACED THE FRAME IAW SRM 51-40-02.SDR SIMA20161216006Support · corrodedTOILET WASTE VALVE SUPPORT IS CORRODED. REPAIRED THE SUPPORT AND INSTALLED A DOUBLER IAW ERS-EM-53MR-2471.SDR SIMA20161215005Frame · corrodedFRAME 25 UPPER FLANGE CRACKED BETWEEN STRINGERS 15 - 16R. REPAIRED THE FRAME IAW SRM 53-00-04 AND ERS-EM-53MR-2472.SDR SIMA20161214002Frame · corrodedFRAME 65 CORRODED UNDER FWD LOWER CARGO DOOR STRIKER PLATE. REPAIRED THE FRAME IAW ERS-EM-53MR-2466SDR SIMA20161203002Yoke · crackedRIGHT ENGINE PYLON FWD LOWER YOKE CRACKED. REMOVED AND REPLACED THE YOKE IAW EO EM-54MR-386SDR SIMA20161121007Wire · brokenLEFT NR 7 AND 9 EMERGENCY LIGHT STRIPS HAD BROKEN WIRES. REPLACED THE LIGHT STRIPS IAW AMM 33-50-12SDR SIMA20161121010Battery Pack · inoperativeNR 4 EMERGENCY LIGHT BATTERY IS DEAD. R & R THE BATTERY IAW AMM 33-50-04.SDR SIMA20161121005Frame · crackedFRAME 25 UPPER FLANGE CRACKED BETWEEN 15R AND 16R. REPAIRED THE FRAME IAW ERS-EM-53MR-2472.SDR SIMA20161121008Yoke · crackedRIGHT ENGINE FWD LOWER YOKE CRACKED. REMOVED AND REPLACED THE YOKE IAW EO EM-54MR-386SDR SIMA20161121009Frame · corrodedFRAME 65 CORRODED UNDER FWD LOWER CARGO DOOR STRIKER PLATE. FABRICATED AND INSTALLED A REPAIR ANGLE IAW SRM 53-31-04 ITEM 4E AND ERS-EM-53MR-2466SDR SIMA20161121006Door Frame · corrodedSERVICE DOOR CUTOUT AFT FRAME IS CORRODED BEHIND LOWER PLASTIC GUIDE. REPAIRED IAW ERS-EM-53MR-2479
Back to N602AE