N602NK
Service difficulty reports · 93
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N602NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N602NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2017123002317A/C Pack · odorFUME ODOR DURING FINAL APPROACH, IN COCKPIT AND CABIN. PREFORMED A PACK BURN OUT IAW AMM 21-00-00. NO FUMES NOTED.SDR GTIA2017120902279Apu · leakingSMELL AT THE CABIN -DIRTY SOCKS SMELL- AT FIRST DURING TAXI POT AND YET AGAIN DURING DESCEND-SMELL DISPITED WIHT BLEED 2/PACK 2 OFF.. ACCOMPLISHED DECONTAMIANTION OF THE ENVIROMENTAL CONTROL SYSTEM WIHT ENGINE AS PER A.M.M 21-00-00-615-003-A/21-00-00-615-004A SDR GTIA2017070702056Bottle · low pressureL2 DOOR ASSIST BOTTLE PRESSURE LOW . L2 DOOR ASSIST BOTTLE SERVICED IAW AMM 52-10-00.SDR GTIA2017062502015Megaphone · inoperativeFWD GALLEY MEGAPHONE INOPERATIVE. R & R FWD GALLEY MEGAPHONE IAW AMM. OPS CHECKED GOOD.SDR GTIA2017051101908Oxygen Mask · damagedCAPTAIN`S OXYGEN MASK MISSING CENTER RIVET. REMOVED AND REPLACED THE OXYGEN MASK IAW AMM 35-12-41, OPS CHECKED GOOD.SDR GTIA2016092601606Engine · failedNR 2 ENGINE EGT OVERLIMIT DURING FLIGHT, FOLLOWD BY A NR 2 ENGINE STALL ECAM. F/A REPORTED FLAMES ON RIGHT SIDE OF AIRCRAFT. AN EMERGENCY WAS DELARED.SDR GTIA2016092501605Bottle · low pressureL2 DOOR ASSIST BOTTLE LOW. SERVICED L2 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2016040101498Bottle · low pressureL2 DOOR ASSIST BOTTLE REQUIRE SERVICE. L2 DOOR ASSIST BOTTLE SERVICED IAW AMM 52-10-00.SDR GTIA2016011001449Bottle · low pressureL2 DOOR ASSIST BOTTOLE REQUIRES SERVICING. L2 DOOR ASSIST BOTTLE SERVICED IAW AMM 52-10-00.SDR GTIA2015122801443Door Frame · dirtySIGNIFICANT HUMMING COMING FROM BOTH EMERGENCY EXITS ACFT LT. REMOVED FWD & AFT LT EXIT HATCHES FOUND EXCESSIVE FRIME AROUND PERIMETER OF DOOR CUT OUT CLEANED AS REQUIRED. INSTALLED FWD & AFT LT EXIT HATCHES IAW AMM 52-21-11, PB401.SDR GTIA2015120301426Bottle · low pressureL2 DOOR ASSIST EMERGENCY CYLINDER REQUIRES SERVICE. CHARGED DOOR ASSIST EMERGENCY CYLINDER IAW AMM 52-10-00.SDR GTIA2015061501575Bottle · low pressureR2 DOOR ASSIST DOOR DAMPER / CYLINDER PRESSURE IS LOW IAW PLACARD TABLE. SERVICED THE BOTTLE WITH NITROGEN AMM 52-10-00-614-001-A. OK FOR SERVICES.SDR GTIA2015032401536Oxygen Mask · brokenF/O O2 MASK INFLATABLE HEAD BAND BROKEN. SWAPPED F/O AND OBSERVER MASK IAW AMM 35-12-41, OPS CHECK OK.SDR GTIA2015032401535Oxygen Mask · inoperative1ST OBSERVERS O2 MASK INOPERATIVE. R & R 1ST OBSERVERS O2 MASK IAW AMM 35-12-41. OPS CHECKED MASK WHICH NOW OPERATES PERFECTLY THIS CLEARS DMI 53165-1 PLACARD REMOVED MOC NOTIFIED.SDR GTIA2015022101512Oxygen Mask · unwanted deployOXYGEN MASK IN FORWARD GALLEY DEPLOYED. RE-STOWED O2 MASK IN FWD GALLEY IAW AMM 35-22-43. PERFORM DROP CHECK IAW AMM 35-23-00 DROP CHECK OK.SDR GTIA2014112701458Bottle · low pressureL2 DOOR ASSIST BOTTLE HAS LOW PRESSURE. DOOR ASSIST BOTTLE SERVICED IAW AMM 52-10-00.SDR GTIA2014111601452Bottle · low pressureL2 PASSENGER DOOR ASSIST BOTTLE LOW. SERVICED THE ASSIST BOTTLE IAW AMM 52-12-14.SDR GTIA2014091601427Megaphone · inoperativeFOUND MEGAPHONE VOLUME NOW MISSING IN FWD GALLEY. R & R MEGAPHONE IN FWD GALLEY IAW AMM 25-65-51.SDR GTIA2014081801411Bottle · low pressureL2 DOOR ASSIST CYLINDER HAS LOW PRESSURE SERVICED L2 DOOR ASSIST CYLINDER AMM-52-10-00.SDR GTIA2014081801410Bottle · low pressureL2 DOOR ASSIST CYLINDER HAS LOW PRESSURE. SERVICED L2 DOOR ASSIST CYLINDER AMM 52-10-00.SDR GTIA2014070901378Bottle · low pressureL2 DOOR ASSIST BOTTLE HAS LOW PRESSURE. SERVICED L2 DOOR ASSIST CYLINDER AMM -52-10-00.SDR GTIA2014050301288Flashlight · inoperativeL2 DOOR F/A EMERGENCY FLASHLIGHT WILL NOT TEST. R & R FLASHLIGHT IAW CMM 25-60-13. OPS TESTED OK.SDR GTIA2014040701254Knob · missingFWD MEGAPHONE MISSING VOLUME KNOB. R & R FWD MEGAPHONE IAW INTERIOR NK320-232-EQ.SDR GTIA2014032401227Battery Pack · inoperativeL2 DOOR F/A FLASHLIGHT INOPERATIVE. R & R FLASHLIGHT BATTERY IAW AMM 25-65-53. OPS CHECKED GOOD.SDR GTIA2014031601217Flashlight · no testFLASHLIGHT AT L1 OTBD & L2 NOT TESTING. R & R BOTH FLASHLIGHTS IAW AMM 25-65-53-000-002/ 400-002-A. OPS CHECKED GOOD.SDR GTIA201402271189Flashlight · inoperativeL1 DOOR OTBD F/A EMERGENCY FLASHLIGHT FAIL TO TEST. R & R F/O'S EMERGENCY FLASHLIGHT IAW AMM 25-65-52-000-001-A/400-001-A. OPS CHECKED GOOD.SDR GTIA20130919970Cylinder · low pressureL2 DOOR ASSIST CYLINDER HAS LOW PRESSURE. SERVICED L2 DOOR ASSIST CYLINDER IAW AMM 52-10-00-614-001.SDR GTIA20130827943Bottle · low pressureDOOR ASSIST BOTTLE HAS LOW PRESSURE. BOTTLE SERVICED TO PROPER PRESSURE IAW AMM.SDR GTIA20130725400Seal · out of alignmentRIGHT OVERWING EMERGENCY EXIT ROW 13 IS MAKING A LOUD HISSING NOISE. REMOVED AND INSPECTED SEAL AT EXIT EMERGENCY DOOR ROW 13.R. APPLIED LAYER OF COMMON GREASE ON THE CONTACT AREA OF THE SEAL IAW ACFT MM.SDR GTIA20130514605Battery · inoperativeFWD F/A FLASHLIGHT INOPERATIVE. R & R FWD F/A FLASHLIGHT BATTERY IAW ACFT MM, OPS CHECKED GOOD.SDR GTIA20130510594Oxygen Mask · no testFWD LT F/A O2 MASK FAILED MANUAL RELEASE TEST. R & R LT FWD F/A O2 MASK IAW AMM. OPS CHECKED IAW AMM.SDR GTIA20130510593Reservoir · misinstalledRT SLIDE INFLATION RESERVOIR FOUND FLEXIBLE CONTROL ASSEMBLY NOT CORRECTLY INSTALLED. INSTALLED IAW AMM.SDR GTIA20130510592Slide · disconnectedL1 DOOR SLIDE NOT SAFETIED ON PARACHUTE PIN. RESAFETIED PIN IAW AMM.SDR GTIA20130329614Warning Light · false activationR1 DOOR SLIDE LIGHT FLASHING WITH SLIDE CLOSED. REPLACED SLIDE WARNING CAPSULE & CONTROL UNIT IAW MM. PRESSURE ACCUMULATOR, COULD NOT DUPLICATE IN FLT WARNINGS.SDR GTIA20130327612Proximity Sensor · out of adjustNUMEROUS DOOR RT FWD ECAMS IN FLIGHT IN BOTH CLIMB & DESCENT. TROUBLESHOOTED IAW MM. ADJUSTED PROXIMITY SENSOR 13WV2 ON R1 DOOR IAW AMM.SDR GTIA20130327613Proximity Switch · out of adjustDOOR R FWD CABIN ECAM. TROUBLESHOOTED IAW MM. ADJUSTED PROXIMITY SWITCH 11WV2 IAW AMM. DOOR WARNING OPS CHECK GOOD.SDR GTIA20130119553Proximity Switch · faultyR1 SLIDE FLASHES ARMED AT GATE WITH DOOR DISARMED. R & R R1 DOOR PROXIMITY SWITCH IAW AMM.SDR GTIA20120107329Cylinder · low pressureL1 CREW/PAX DOOR CYL DAMPER PRESSURE LOW. SERVICED L-1 CREW PAX DOOR CYL DAMPER PRESS IAW AMM TASK 52-10-00-614-001-A.SDR GTIA20110921256Cylinder · low pressurePASSENGER DOOR L1 REQUIRES SERVICING. LOW PRESSURE. SERVICED PASSENGER DOOR L1 IAW AMM 52-10-00-614-001.SDR GTIA20110709204Cylinder · low pressureR1 DOOR ASSIST CYLINDER PRESS LOW NOTE:SVC'D 10 TIMES SINCE 5-1-11. R & R R1 DOOR ASSIST CYLINDER IAW AMM TASK 52-11-14-000-001 & 52-11-14-400-001.SDR GTIA20110706203Accumulator · low pressureDOOR ACCUMULATOR PRESSURE LOW. SERVICED DOORS TO PROPER PRESSURE IAW AMM 52-10-614-001.SDR GTIA1100013Door · low pressureR1 DOOR HAS LOW PRESSURE. SERVICED R1 DOOR IAW AMM 52-10-00-614-001.SDR GTIA1100005Tire · overtempRTO LOW SPEED NR 80KTS DUE TO "HOT BRAKE" ECAM LT MLG BRAKE NR 1 885C BRAKE NR 2 905C. FOUND NR 1 & NR 2 MLG TIRES FLAT, THERMAL FUSES MELTED. INSPECTED NR 1 & NR 2 MLG AXLES & BRAKES IAW AMM 05-51-16-200-001. NO DEFECTS FOUND ON AXLES. NR 1 & NR 2 BRAKES R
Back to N602NK