N604AU
Service difficulty reports not matched to an aircraft · 82
They name N604AU, but no registry record covers the date, the aircraft registered then was built later, or the report describes another aircraft. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N604AU' AND registry_match IS NULL ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N604AU' AND registry_match IS NULL ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA060680Skin · corrodedINBOARD LOWER EDGE (NR 5 SLAT) SLAT NR 5 SN-1501 AL CORROSION. REMOVED, BONDED, REPAIRED DAMAGE PER SRM 51-70-06, DEFECT SIZE: 0.75"L X 0.5"W X .082"D.SDR USAA060679Stringer · corrodedBS 1640-1680 STRINGER 29R CORRODED. REMOVED & REPLACED DAMAGED SECTION PER SRM 53-00-03, DEFECT SIZE: 21 X 1.0 INCH.SDR USAA060678Strap · crackedSTA 377 LBL 35.5 WL 208 FLOORBEAM STABILIZER STRAP CRACKED. FABRICATED DOUBLER & INSTALLED PER SRM 53-10-51, 51-20-01, DEFECT SIZE: 2.5 INCH.SDR USAA060681Skin · chafedRIGHT WING LEADING EDGE OF I/B FLAP, 71 INCHES FROM I/B END CHAFED. REPAIRED PER SRM 57-53-01, 51-21-10, DEFECT SIZE: 5"L X 1"W X .004"D.SDR BB05038Light · inoperativeTPA - FOUND EMERGENCY LIGHT AT ROW 12 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY.SDR USAA040574Frame · crackedCLT - FOUND FRAME AND CLIP CRACKED .375 INCH AND .5 INCH, STATION 680 STRINGER 21L FRAME AND CLIP. REPLACED DAMAGED FRAME AND STRINGER CLIP PER EA 95653, SRM 53-30-07. (M)SDR USAA040575Web · corrodedCLT - FOUND AFT CARGO DOOR CORRODED 1 INCH BY 1 INCH, 22 INCHES AFT OF FORWARD EDGE, WEB. REPLACED DAMAGED WEB PER SRM 51-40-02. (M)SDR USAA040576Structure · corrodedCLT - FOUND AFT CARGO DOOR CORRODED 1 INCH BY 1 INCH AREA, AFT CARGO 21 INCHES FORWARD OF AFT DOOR EDGE WEB. REPLACED DAMAGED WEB PER SRM 51-10-02. (M)SDR USAA040577Stringer · corrodedCLT - FOUND STRINGER CORRODED 2 SQUARE INCHES, STRINGER 28L AT BS 656, STATION 648. REPLACED STRINGER SECTION PER SRM 53-00-03. (M)SDR USAA040578Strap · crackedCLT - FOUND STABILIZER STRAP CRACKED .5 INCH, STATION 560, SECTION 43, LBL 15. INSTALLED REPAIR DOUBLER PER SRM 51-70-11. (M)SDR USAA040579Strap · corrodedCLT - FOUND DOUBLER STRAP CORRODED 6 SQUARE INCHES, STATION 290, LBL COCKPIT FLOOR LEVEL. FABRICATED AND INSTALLED DOUBLER STRAP PER EA 95679, SRM 51-40-02, DWG 141N5810. (M)SDR USAA040581Skin · delaminatedCLT - FOUND TRAILING EDGE FLAPS DELAMINATED 6 INCHES, INBOARD MAIN FLAP AT OUTBOARD TRAILING EDGE. REPLACED TRAILING EDGE WEDGE PER BOEING DWG 113N2600. (M)SDR USAA040580Beam · crackedFOUND BEAM CORRODED 7 INCHES BY 4 INCHES AND TWO INCH CRACK, STATION 297, LBL 22. REPLACED BEAM PER EA 9579, SRM 51-10-02. (M)SDR USAABB04035Glowstrip · missingCLT - FOUND EMERGENCY LIGHT PHOTOLUMINESCENT STRIPS MISSING AT ROW 1 AND BETWEEN ROWS 2 AND 3. MAINTENANCE REPLACED THE STRIPS. (M)SDR USAABB04036Glowstrip · missingFOUND EMERGENCY LIGHT PHOTOLUMINESCENT STRIPS MISSING AT ROW 1 AND BETWEEN ROWS 2 AND 3. MAINTENANCE REPLACED THE STRIPS. (M)SDR USA2004F00005Odor · detectedDURING MAINTENANCE FERRY FLIGHT, CREW REPORTED A SMOKE ODOR IN THE FLIGHT DECK. FLIGHT LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE RAN PERFORMED AN ENGINE RUN WITH THE PACKS ON. THE CONDITION COULD NOT BE DUPLICATED.SDR USAABB03227Sign · inoperativePHL - FOUND R4 DOOR EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB03211Battery · dischargedTPA - FOUND FLOOR LEVEL EMERGENCY LIGHTS AT ROWS 4, 9 AND 33 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB03176Battery · weakBDL - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 18 WEAK. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB03115Bottle · dischargedBWI - FOUND THE L1 DOOR ASSIST BOTTLE EMPTY DURING A WEEKLY CHECK. MAINTENANCE REPLACED THE BOTTLE. (M)SDR USAA030094Door Frame · crackedFOUND FRAME CRACKED .25 INCH, BS 1380 AFT CARGO DOOR FRAME NR 6 STOP HOLE. WEB REPLACEMENT/SPLICED. (M)SDR USAA030095Door Frame · crackedFOUND FRAME CRACKED .25 INCH, BS 144 AFT CARGO DOOR FRAME NR 6 STOP HOLE. WEB REPLACEMENT/SPLICED IN PER EA 87279. (M)SDR USAA030091Web · crackedPIT - FOUND WEB CRACKED 1 INCH, BS 620 AT DOOR STOP NR 6. DAMAGE CUT OUT, INSTALLED NEW WEB SECTION AND REPAIR DOUBLERS PER SRM 53-00-07 FIG 202 AND EA 87277. (M)SDR USAA030090Web · crackedFOUND WEB CRACKED .5 INCH, BS 560 STRINGER 20 RT. DAMAGE REMOVED, INSTALLED FABRICATED WEB SECTION AND REPAIR DOUBLERS PER SRM 53-00-07 FIG 202 AND EA 87.SDR USAABB03058Battery · inoperativePHL - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 18 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB03027Battery · dischargedFOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 22, INOPERATIVE. MAINTENANCE REPLACED THE BATTERY.SDR USAABB02200Battery · inoperativeSJU - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 26 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAA020440Skin · crackedCLT - FOUND INNER SKIN CRACKED .250 INCH, ABOVE LOWER HINGE BOX, L4 DOOR INNER SKIN 1661. INSTALLED REPAIR DOUBLER ON INNER DOOR SKIN PER EA 86643. (M)SDR USAA020441Skin · crackedCLT - FOUND SKIN CRACKED .75 INCH, INBOARD TRAILING EDGE FLAP RIGHT WING ABOVE NR 6 FLAP TRACK LINKAGE. INSTALLED REPAIR STRAP AFTER DAMAGE AREA TRIMMED PER EA 86716. (M)SDR USAA020401Intercostal · crackedCLT - FOUND INTERCOSTAL CRACKED 1 INCH, STATION 480 LBL 40 6 INCHES BELOW FLOOR LEVEL. REPAIR ANGLE INSTALLED PER SRM 51-70-11. (M)SDR USAA020400Intercostal · crackedCLT - FOUND INTERCOSTAL CRACKED 10 INCHES, BL 0 BETWEEN STATION 440 AND 460 FLOOR LEVEL. FABRICATED AND INSTALLED NEW INTERCOSTAL PER SRM 51-10-02. (M)SDR USAA020399Intercostal · crackedCLT - FOUND INTERCOSTAL WITH 2 INCH CRACK, STATION 440 BL 0 BELOW FLOOR LEVEL. FABRICATED AND INSTALLED NEW WEB SECTION PER SRM 51-10-02. (M)SDR USAA020396Intercostal · crackedINTERCOSTAL HAS 10 INCH CRACK BL 0 BETWEEN STA 540 AND 560. INSTALLED NEW INTERCOSTAL.SDR USAA020398Intercostal · crackedCLT - FOUND CHORD WITH MULTIPLE CRACKS, MAXIMUM WIDTH .125 INCH, UPPER CHORD OF INTERCOSTAL AT BL 0, BS 1420-1440. FABRICATED AND INSTALLED NEW ANGLE AND SHIM PER SRM 53-00-51. (M)SDR USAA020442Intercostal · crackedCLT - FOUND CHORD CRACKED .125 INCH, UPPER CHORD INTERCOSTAL AT BL 0, BS 1420-1440. FABRICATED AND INSTALLED NEW ANGLE PER SRM 53-00-51. (M)SDR USAABB02107Slide · tornPHL - DURING AN SLIDE INFLATION OPERATIONAL CHECK ON THE L3 DOOR, THE SLIDE TORE IN THE THRESHOLD AREA. THE TEAR EMANATED FROM THE CENTER OF THE MATERIAL AND PROGRESSEDOUT TOWARD THE EDGES. THE EDGES OF THE SLIDE REMAINED INTACT. THE SLIDE INFLATED PROPERLYSDR USA2002F00064Slide · tornDURING A SLIDE INFLATION OPERATIONAL CHECK ON THE LEFT 3 DOOR, THE SLIDE TORE IN THE THRESHOLD AREA. THE TEAR EMINATED FROM THE CENTER OFT HE MATERIAL AND PROGRESSED OUT TOWARD THE EDGES. THE EDGES OF THE SLIDE REMAINED INTACT. THE SLIDE INFLATED PROPERLY ASDR USAABB02064Battery · dischargedPHL - FOUND FLOOR LEVEL EMERGENCY LIGHTS AT ROWS 9, 13, 18, 22, 29 AND 33 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB02029Battery Pack · dischargedLAX - FOUND AFT EMERGENCY LIGHT BATTERY PACK INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK. (M)SDR USAA020046Fitting · corrodedCLT - FOUND LUG/BORE CORRODED, INBOARD SIDE LOAD FITTING MOUNT LUG. REBORED/BLENDED/REWORK OF LUG/BUSHED PER EA 85775. (M)SDR USAA020045Fitting · corrodedCLT - FOUND FITTING LUG/BORE WITH CORROSION. REWORKED LUG PER EA 85775. (M)SDR USAA011347Skin · dentedCLT - FOUND SKIN DENTED 3.4 INCHES BY 3 INCHES, STATION 150 AND S24R AFT CARGO DOOR. INSTALLED EXTERNAL DOUBLER PER SRM 53-00-01. (M)SDR USAA011341Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 6 INCHES, STATION 1300 FLOORBEAM, LBL 12 AND 18. INSTALLED NEW T-CAP PER TR 53-15-01. (M)SDR USAA011369Frame · corrodedCLT - FOUND FRAME CORRODED, STATION 1300, RBL 4 LOWER CHORD ANGLE. FABRICATED AND INSTALLED NEW SHEAR TIE PER SRM 51-40-02. (M)SDR USAABB01101Battery · dischargedBWI - FOUND FLOOR LEVEL EMERGENCY LIGHTS AT ROWS 1, 4, 9, 13, 18, 23, 26 AND 29 WEAK. MAINTENANCE REPLACED THE BATTERIES AS A PRECAUTION. (M)SDR USAABB01100Battery · dischargedBWI - FOUND FLOOR LEVEL EMERGENCY LIGHTS AT ROWS 6 AND 33 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB01063Light · inoperativeBWI - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 18 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB01062Battery · dischargedBWI - FOUND LOW LEVEL EMERGENCY LIGHTS AT ROWS 6 AND 33 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB01045Battery · dischargedLAX - FOUND LOW LEVEL EMERGENCY LIGHTS INOPERATIVE AT ROWS 1, 4, 22, 29 AND 33. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB00119Light · inoperativeLAX - FOUND L4 DOOR EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)