N609NK
Service difficulty reports · 40
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N609NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N609NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2024050738104Heater · inoperativeR WSHLD HEAT INOP-PERFORMED RESET OF R WSHLD HEAT IAW AMM 30-42-00 FAULT CLEARED OPS CHECK GOOD AT THIS TIMESDR GTIA2024010737738Megaphone · inoperativeL1 DOOR MEGAPHONE GREEN TEST LIGHT INOP-R&R L1 DOOR EMERGENCY MEGAPHONE IAW AMM 25-65-51-820-001-A MOC 109580 NOTIFIED A/C OK FOR SERVICESDR GTIA2023112137635Megaphone · inoperativeAFT FA MEGAPHONE INOP-REMOVED/ REPLACED AFT FA ATTENDANT MEGAPHONE IAW SPIRIT AIRLINES DRAWING # A320-EMER-EQUIPSDR GTIA2023112137627Fitting · corrodedCORROSION FOUND ON FWD CARGO AFT CUTOUT FR 28 FITTING STR 37R-39R MEASURING 1.54"L .836"W .075"D. RAF 01 CREATED. SDR SUBMITTED-ACCOMPLISHED REPLACEMENT AND BUSH REPAIR PER A320 SRM 51-72-11-911-002, 53-21-29-04 RDAF 81309453/003/2024 A REF EA 5321-2392 ON FWDSDR GTIA2023112137626Door Sill · corrodedCORROSION FOUND ON AFT CARGO BULK CARGO DOOR SILL AT FR 60-62 STR 38R MEASURING 2.0"L .75"W .040"D. RAF 01 CREATED. SDR SUBMITTED-REMOVED AND REPLACED AFT CARGO BULK CARGO DOOR SILL IAW A320 SRM 53-41-49-300-002SDR GTIA2023112137625Door Sill · corrodedCORROSION FOUND ON R2 DOOR SILL AT FR 68 STR 23RH MEASURING 0.750"L 0.5"W 0.063"D. RAF-01 CREATED. SDR SUBMITTED-REMOVED CORROSION AFT WET AREA AT R2 DOOR SILL AT FR 68 FOUND TO BE OUT OF LIMITS IAW A320 SRM 53-41-41 FIG 002. FABBED REPAIR ANGLE IAW A320 SRM 5SDR GTIA2023112137624Skin · corrodedCORROSION FOUND ON R1 LOWER DOOR SKIN AT FR 18 STR 23R MEASURING 1.6" W 0.023" D. RAF-01 CREATED. SDR SUBMITTED-ACCOMPLISHED PERMANENT REPAIR REF HAECO SO 122182 EA 5311-2385 AND OPS 38399SDR GTIA2023112137623Skin · corrodedCORROSION FOUND ON L1 LOWER DOOR SKIN AT FR 18 STR 23L MEASURING 2.8" L 1.6" W AND 0.14" D. RAF-01 CREATED. SDR SUBMITTED-ACCOMPLISHED PERMANENT REPAIR REF HAECO SO 122182 EA 5311-2386 AND OPS 38397SDR GTIA2022062736498Megaphone · inoperativeFA REPORTS FWD MEGAPHONE INOP-R/R FWD MEGA PHONE IAW AMM 25-65-00. OPS CHECK NORMALSDR GTIA2022062736496None · noneELECTRICAL SMOKE OTHER FWD GALLEY ON APPROACH -PERFORMED INSPECTION OF FWD GALLEY IAW TSM 05-50-00-810-831-A. NO DEFECTS NOTED AT THIS TIME A/C OK FOR SVCSDR GTIA2022041436380None · noneFA REPORTED A DIRTY SOCK SMELL AT CRUISE. PAK 1 WAS SHUT OFF. AFTER A FEW MIN, THE ORDER WENT AWAY-PERFORMED PACK 1 OPS CHECK IAW TSM 05-50-00-810-831-A NO SMELL PRESENT. OP CHECK GOODSDR GTIA2021110436093None · noneREPAIR/REPLACE LH MLG RETRACTION JACK ANCHORAGE FITTING-PERFORMED CAT C REPAIR REF HAECO S/O 122117 OPS 24020SDR GTIA2021110436092None · noneREPAIR/REPLACE RH MLG RETRACTION JACK ANCHORAGE FITTING-PERFORMED CAT C REPAIR REF HAECO S/O 122117 OPS 24019SDR GTIA2021110436091None · noneREPAIR/REPLACE THE NLG RH TRUNNION BEARING-PERFORMED CAT A REPAIR REF HAECO S/O 122117 OPS 24017SDR GTIA2021071235862Unknown · odorDIRTY SOCKS ODOR ON DESCENT INTO CUN. BAD SMELL OBSERVED IN COKPIT + REAR GALLEY-PERFORMED TSM 05-50-00-810-831-A IDENTIFICATION OF CAUSE PER CABIN ODOR PERFORMED OPS CHECK PACK 1 AND 2, APU AND ENGINE 1 AND 2 WITH FLIGHT CREW ASSISTENCE NO DISCREPANCY FOUND SDR GTIA2021040535673Bottle · low pressureL1, L2, R1 AND R2 ASSIST BOTTLE REQUIRE SERVICE-SERVICED L1, L2, R1 AND R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00. LEAK CHECK GOOD.SDR GTIA2020110235422Duct · chafedDURING INSPECTION PYLON NR 1 AIR DUCT BETWEEN RIB 8 & RIB 9 FOUND CLAMP ATTACHMENT CHAFING IN THE STRUCTURE SURFACE RAF 2551952-2 CREATED REF LTPR NRI 5001021057-0010. PERFORMED REPAIR AS PER EO 5452-2002 REV 00 AS PER AIRBUS RDAS REF 80844733/007/2020 ISSUESDR GTIA2020012734968A/C Pack · odorPOSSIBLE FUME EVENT DURING DESENT. FUMES ONLY SMELLED BY FLIGHT ATTENDANTS, NR 2 PACK WAS TURNED OFF AND FLIGHT ATTENDATS REPORTED THE SMELL WENT AWAY.SDR GTIA2019121234856Acm · leakingON TAKEOFF FROM CLT FUMES SMELL IN CABIN AND COCKPIT APPLIED COM 3.226.1 FUME DISSAPATED WITH PACK 1 OFF ON DECENT INTO MCO , OUT OF 10,000 FT FUMES STARTED AGAIN WITH PACK 1 STILL OFF.-ACCOMPLISHED TSM 05-50-00-810-831-A FOR CABIN ODOR RAN BOTH PACKS ON APU BSDR GTIA2019061703425Knob · missingFWD MEGAPHONE KNOB MISSING. R/R FWD MEGAPHONE AND OPS CK OK IAW AMM 25-60-00.SDR GTIA2019052003359Unknown · malfunctionedLEFT MAIN LANDING GEAR DOOR FAILED TO CLOSE AFTER TAKE OFF.SDR GTIA2018120322986Unknown · odorFUME EVENT AFT CABIN TURNED OFF PACK 2 SMELL DISSIPATED-PERFORMED IDENT OF COS REF TSM 05-50-00-810-831-A NO ODARS PRESENT AT THIS TIME APU CHECKED REF AMM 29-00-00 ENG RUN W/ FLT CREW & OPS CHECKED REF AMM 71-00-00SDR GTIA2018071902752Knob · missingCREW REPORTS FWD MEGAPHONE VOLUME KNOB MISSING. R&R FWD MEGA PHONE IAW DRAWING NK320-232-EQ. NO FURTHER DEFECTS NOTED.SDR GTIA2018021502430Megaphone · malfunctionedFA REPORTED LIGHT FLASHING ON AFT GALLEY MEGAPHONE. FOUND PA ALWAYS ON ACTIVE. R & R THE AFT GALLEY MEGAPHONE IAW DRAWING NKS320-232EQ, REV 6.SDR GTIA2017120402268Relay · malfunctionedR2 DOOR SLIDE INDICATES NOT ARMED IN FLIGHT .. PERFORMED TSM 52-13-00-810-809-A. , R&R PWR SUPPLY RELAY 12WW IAW AMM 52-77-01. OPS CHECK GOOD A/C OK FOR SVC.SDR GTIA2017090602167Bottle · low pressureL2 DOOR ASSIST BOTTLE REQ SERVICING .. SERVICES L2 DOOR ASSIST BOTTLE TO PROPER LEVEL IAW AMM 52-10-00SDR GTIA2017070502046Bottle · low pressureL2 DOOR ASSIST BOTTLE REQUIRED SERVICE. SERVICED THE L2 DOOR ASSIST BOTTLE IAW AMM S2-10-00.SDR GTIA2017062702025Bottle · low pressureL2 DOOR ASSIST BOTTLE LOW PRESSURE. SERVICE THE L2 DOOR IAW AMM 52-10-00SDR GTIA2017061301983Warning Message · false activationRT EMERGENCY EXIT ECAM WARNING DURING CLIMBOUT. MESSAGE IMMEDIATELY CLEARED, NO RECALL AND PRESSURIZED NORMAL ENROUTE. INSPECTED COVER FLAP OF EMERGENCY EXIT HATCH IAW AMM 52-21-11-991. NO DEFECTS NOTED. NO ECAM INDICATIONS NOTED. ACFT OK FOR CONTINUED SERSDR GTIA2017060801974Unknown · odorDURING FLIGHT, THE FLIGHT ATTENDANTS REPORTED AN ODOR AT ROWS 7-13, SMELLED LIKE NAIL POLISH OR A RADIATOR. PERFORMED TSM 05-50-00-810-831-A. PERFORMED COMPARTMENT CHECK OF APU BLEED WITH PACKS 1 AND 2 IAW AMM 21-00-00. COULD NOT DUPLICATE THE ODOR. ACFT OSDR GTIA2016052701459Oxygen Mask · brokenCAPTAIN'S O2 MASK IS MISSING 1 RETAINING CLIP THAT HOLDS THE INFLATION HEADSTRAP TO THE FACE MASK. R & R CAPTAIN'S O2 MASK IAW AMM 35-12-41, PB401. OPS CHECK GOOD.SDR GTIA2015120401427Bottle · low pressureL2 DOOR ASSIST BOTTLE LOW. SERVICED L2 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2015070901597Oxygen Mask · brokenF/O OXYGEN MASK IS BROKEN. R & R THE OXYGEN MASK IAW AMM 35-12-41. OPS AND LEAK CHECKED GOOD.SDR GTIA2014062301352Disk · rupturedL4 DOOR EMERGENCY CYLINDER DAMPNER PRESSURE DISK RUPTURED. R & R DIAPHRAGM IAW AMM 52-10-00.SDR GTIA2014053001326Oxygen Mask · damagedFIRST OBSERVERS OXYGEN MASK HAS HOLE IN HEAD BAND. R & R OXYGEN MASK ASSY IAW AMM 35-12-41.SDR GTIA201401151117Oxygen Mask · leakingF/O OXYGEN MASK LEAKS. RESTOWED F/O OXYGEN MASK AND PERFORMED OPS CHECK IAW AMM. NO LEAKS DETECTED, O2 PRESSURE STEADY.SDR GTIA201312261089Oxygen Mask · leakingCREW OXYGEN LOW. OBSERVERS MASK HISSING ENROUTE. ONE ADDITIOINAL TEST & RESET, MASK NORMAL. R & R F/O'S FULL FACE OXYGEN MASK, TESTED OK. NO LEAKS NOTED.SDR GTIA201312101064Life Vest · damagedSEAT 16A LIFE VEST ASSY MISSING RED LIFE VEST PULL STRAP. R & R LIFE VEST ASSY IAW AMM.SDR GTIA201311051026Oxygen Mask · leakingOXYGEN MASK PRESSURE REGULATOR BLINKER ON F/O SIDE IS LEAKING AIR PRESSURE. OPS CHECKED OXYGEN MASK PRESSURE REGULATOR IAW AMM, OPS CHECKED GOOD, NO LEAKS FOUND.SDR GTIA20130601635Actuator · failedMASK AT SEAT 23 DEF FAILED DROP CHECK. R & R O2 ACTUATOR ON 23 DEF. O2 BOX IAW CMM 35-21-74, OPS TEST GOOD IAW AMM 35-23-00-710-001A W/C ON N/R 7170N00123.
Back to N609NK