N611AE
Service difficulty reports · 208
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N611AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N611AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20220621001Door · dirtyPASSENGER DOOR HARD TO OPEN. FA COULD ONLY GET THE DOOR TO OPEN PART WAY UNTIL THE GATE AGENT PULLED THE DOOR FROM OUTSIDE THE AIRCRAFT-C/A-CLEANED AND LUBRICATED DOOR ROLLERS. OPC OF DOOR GOOD PER AMM 52-10-01SDR SIMA20220530002None · noneFA HAD DIFFICULTY OPENING AND CLOSING MAIN CABIN DOOR-C/A-CLEANED AND LUBED PAX DOOR IAW AMM 53-21-02 HANDLE OPS CHECK GOOD IAW AMM 52-10-01SDR SIMA20220527001Inverter · inoperativeROW 1 FLOOR STRIP EMERGENCY LIGHTS INOP-C/A-RAR #2 INVERTER IAW EMB AMM 33-50-11-000-801-A AND 33-50-11-400-801-A. OPC GOOD. END.SDR SIMA20220518003None · inoperativeAFT GALLEY G2 EMERGENCY LIGHT INOP-C/A-RAR AFT GALLEY G2 EMERGENCY LIGHT IAW AMM 33-50-14 OPS CHECK GOOD.SDR SIMA20220412001Lamp · inoperativeGALLEY EMERGENCY LIGHT INOP-C/A-RAR THE GALLEY EMERGENCY LT LAMP IAW EMB AMM 33-50-09-000-801-A AND 33-50-09-400-801-A. OPS CHECK GOOD.END.SDR SIMA20220219001None · noneFA'S EMERGENCY FLASHLIGHT HOLDER BROKEN-C/A-RAR FA'S FWD EMERGENCY FLASHLIGHT ASSY IAW AMM 33-50-16. OPS CHECKED GOOD.SDR SIMA20211227008None · noneMEL 21-20 AUTH# 120348DM-C. ELECTRO PNEUMATIC OUTFLOW VALVE INOP DUE TO MEL 21-17 RETURN TO FIELD..PRESSURIZATION ISSUES..DECLARED EMRG AND LANDED WITHOUT FURTHER INCIDENT-C/A-REACTIVATED ELECTROPNEUMATIC OUTFLOW VALVEAS PER AMM 21-31-03-440-801A.OPS CHECK GOOSDR SIMA20211009001None · noneSERVICE DOOR EMERGENCY LIGHT INOP-C/A-RAR SERVICE DOOT EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-09-000-801-A AND 33-50-09-400-801-A. OPC GOOD. END.SDR SIMA20210830001Flashlight · inoperativeMEL 2532 - AUTH# 080401M-C ORIG. AML PG. 4734772 ITEM #1 AFT CABIN FA EMERGENCY FLASHLIGHT INOP-C/A-RAR AFT CABIN EMERGENCYFLASHLIGHT IAW AMM 33-50-16. OPC GOOD. MEL ITEM RESTORED.SDR SIMA20210829001Flashlight · inoperativeCABIN AFT FA EMERGENCY FLASHLIGHT INOP.-C/A-FLIGHT CREW PLACARDED CABIN AFT FA EMERGENCY FLASHLIGHT. M PROCEDURES C/W. MEL 25-32 AUTH# 080401M-C MOC# 737389 CC# 696266SDR SIMA20210531002Lamp · inoperativeRH UPPER OVER WING EMERGENCY LIGHT INOP-C/A-RAR RH UPPER OVER WING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10. OPC GOOD.SDR SIMA20210125003Fan · odorBRIEFLEY ON TAKEOFF AND INTERMITTENTLY IN FLIGHT AN ODD SMELL WOULD COME UP IN THE COCKPIT/CABIN SMELL WAS SIMILAR TO ELECTRICAL BURNING. TRANSFERRED TO NRWC 611-DFW-03584. C/A: R & R NR 1 RECIRCULATION FAN, PER AMM 21-22-05. OPERATIONAL CHECK GOOD SWEE NRWSDR SIMA20210111001Bulb · inoperativeRT OVERWING EXIT AFT EMERGENCY LIGHT INOPERABLE. C/A: REMOVED AND INSTALLED LIGHT BULB, IAW EMB AMM 33-50-10. OPERATIONS CHECK GOOD.SDR SIMA20210101002Lamp · inoperativeCABIN AFT AISLE EMERGENCY LIGHT INOPERABLE. C/A: REMOVED AND REPLACED AFT AISLE EMERGENCY LIGHT LAMP, IAW EMB 145 AMM 33-50-08. OPERATIONAL CHECK GOOD.SDR SIMA20201130004Light · inoperativeEMERGENCY FLOOR LIGHT STRIP AT SEAT 8 INOPERABLE. C/A: R & R SEAT 8 EMERGENCY FLOOR LIGHT STRIP, IAW AMM 33-50-12. OPERATIONS CHECK GOOD.SDR SIMA20201105002Lamp · inoperativeDURING PS-2 CHECK FOUND RIGHT HAND CENTER FAIRING EMERGENCY LIGHT OUT. C/A: R & R RT CENTER FAIRING EMERGENCY LIGHT LAMP, IAW EMB AMM 33-50-10. OPERATIONS CHECK GOOD.SDR SIMA2020062210002Yoke · crackedLEFT ENGINE FORWARD YOKE LOWER CLEVIS HAS POSSIBLE CRACK IN RADIUS. REPLACED LT ENG FWD LWR YOKE FITTING IAW ERS-EM-54MR-698.SDR SIMA2020060219002Bracket · crackedFORWARD CARGO DOOR TORSION BAR BRACKET AT FRAME 61 HAS A 1/8" CRACK. INSTALLED NEW BRACKET IAW SRM 51-40-02.SDR SIMA202005219001Support · crackedSUPPORT ON THE AFT SIDE OF FRAME 68 FOR CARGO DOOR HOLD OPEN STRUT HAS A 3/4" CRACK.-C/A-REMOVED AND INSTALLED NEW SUPPORT IAW SRM 51-40-02.SDR SIMA202005217009Support Angle · crackedRIGHT OMEGA BEAM OUTBOARD LOWER SUPPORT "L" ANGLE IS CRACKED APPROXIMATELTY 1 1/2" ON THE FORWARD END BETWEEN FRAMES 47-48.-C/A-REMOVED AND REPLACED RH OMEGA BEAM OUTBD LOWER SUPPORT L ANGLE IAW SRM 51-40-02.SDR SIMA202005217011Floor Support · corrodedLEFT OMEGA BEAM AFT OF CROSSBEAM 24 HAS CORROSION.-C/A-REMOVED AND REPLACED PREVIOUS REPAIR DOUBLER ON LH OMEGA BEAM IAW SRM 51-40-02.SDR SIMA202005217010Support Angle · crackedRIGHT OMEGA BEAM INBOARD LOWER SUPPORT "L" ANGLE IS CRACKED APPROXIMATELTY 1 1/2" ON THE FORWARD END BETWEEN FRAMES 47-48-C/A-REMOVED AND REPLACED RH OMEGA BEAM INBD LOWER SUPPORT L ANGLE IAW SRM 51-40-02.SDR SIMA2020063014004Skin · crackedLEFT FUSELAGE SKIN AT FRAME 79 HAD SMALL CRACKS PROTRUDING FROM A RIVET. REPAIRED IAW SRM 53-32-01.SDR SIMA2020063014003Skin · crackedRIGHT FUSELAGE SKIN AT FRAME 77 HAD SMALL CRACKS PROTRUDING FROM TWO RIVETS. REPAIRED IAW SRM 53-32-01.SDR SIMA2020070225009Strip · tornNR 8 EMERGENCY LIGHT STRIP IS TORN. REMOVED AND REPAIRED THE NR 8 EMERGENCY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA2020031211002Wire · brokenSERVICE DOOR EMERGENCY LIGHT WIRE BROKEN-C/A-REPAIRED SERVICE DOOR EMERGNCY LIGHT BROKEN WIRE IAW AWM33-50-50, AND AMM 20-21-00. OPT GOOD IAW AMM 33-50-00.SDR SIMA202001197005Lamp · inoperativeLH SIDE CENTER FAIRING EMERGENCY LIGHT INOP-C/A-RAR LH SIDE CENTER FAIRING EMERGENCY LIGHT LAMP IAW EMB 145 AMM 33-50-10 OPS CHECK GOOD.NO FURTHER DEFECT DETECTEDSDR SIMA2020010230004Lamp · inoperative12C OVERHEAD EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED 12C OVERHEAD EMERGENCY LIGHT LAMP IAW EMB AM AND 33-50-08-400-801-A. OPC GOOD.SDR SIMA20191227001Light · inoperativeLEFT OVERWING EMERGENCY LIGHT INOPERATIVE. ADJUSTED THE LEFT OVERWING EMERGENCY LIGHT IAW AMM 33-50-10.SDR SIMA201911298002Lamp · inoperativeROW 12 B/C OVERHEAD EMERGENCY LIGHT INOP-C/A-RAR ROW 12 B/C OVERHEAD EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-07-000-801-A AND 33-50-07-400-801-A. OPS CHECK GOOD. ENDSDR SIMA201911187002Unknown · odorEXTREMELY STRONG ODOR IN COCKPIT ON DESCENT FROM 8000 TO 5000 FEET.WET SOCK SMELL.APU OFF.ENGINE BLEEDS POWERING PACKS LASTED 2 -3 MINUTES-C/A-STARTED ENGINES AND RAN PACKS IAW EMB AMM 21-51-00 AND AMM 71-00-00. NO ODER NOTICED.C/W ETN-EM-72-034 .NO OTHER ODERSDR SIMA20190717003Light · inoperativeSERVICED DOOR EMERGENCY LIGHT INOP. C/A-RAR SERVICE DOOR EMERGENCY LAMP IAW AMM 33-50-09-000-801-A AND 33-50-09-400-801-A. OPS CHECK GOOD. END.SDR SIMA201906243002Tube · damagedPACK 1HAD STRONG DIRTY SOCK ODOR OM TAKE OFF & CLIMBOUT AND CRUISE. C/W ETN EM-72-034. NO OILY/SOCK SMELL NOTICED. WHILE PERFORMING ETN FOUND THE NR 1 PACK DUAL TEMP. CONTROL VALVE Y DUCT WARPED, REMOVED AND REPLACED THE Y DUCT IAW AMM 2160-01. OPS CHECK GOOSDR SIMA201906043003Controller · failedWHILE PARKED AT GATE, EICAS "PRESN AUTO FAIL" PRESENTED. WHITE SMOKE NEAR THRUST LEVERS AND ELECTRICAL BURNING SMELL. FOUND "PRESS CONTROL" F8 BREAKER POPPED. (ENGINES WERE NOT RUNNING)-C/A-FOUND SMELL AND WHITE SMOKE COMING FROM AUTO PRESSURIZATION DIGITALSDR SIMA20190522004Light · inoperativeMAIN DOOR EMERGENCY LIGHT INOP. C/A-RAR MAIN DOOR EMERGENCY LT LAMP IAW AMM 33-50-06-000-801-A AND AMM 33-50-06-400-801-A. OPC GOOD. NO MORE DEFECTS NOTED AT THIS TIME. END.SDR SIMA20190116002Support Angle · crackedSUPPORT BRACKET AT FRAME 80 IS CRACKED (LT SIDE). C/A-INSTALLED NEW BRACKET IAW SRM 51-40-02..SDR SIMA20190111006Skin · damagedIN REFERANCE TO TSA DAMAGE ID 145-00074-00006-001 FORWARD FUSELAGE SKIN JUST ABOVE BATTERY COMPARTMENT BETWEEN FRAMES 4 AND 5. C/A-COMPLETED REPAIR IAW ERS EM-5300-3623 AND ERS EM-53MR-3816. REF NWRC E685453. SKIN P/N 123-06513-009. SPLICE PLATE P/N 123-10953-SDR SIMA20190108003Support · crackedRT UPEER WING/FUSELAGE SUPPORT IS CRACKED APROX. 3/4" BETWEEN THE RIVETS. JUST AFT OF FRAME 50. C/A-INSTALLED NEW RT UPPER WING/FUSELAGE SUPPORT IAW SRM 51-40-02.SDR RAIA201807170001Unknown · odorPOST TAKE OFF AT 1800 TO 200 FL, AN ELECTRICAL BURNING SMELL DETECTED ON FLIGHT DECK. (PILOTS FOUND SMELL COMING FROM PACK NR 1). OPS CHECK AC PACK 1 AND PACK 1 DISTRIBUTION SYSTEM. OPS CHECK GOOD. INSPECTED ALL ELECTRONICS IN FLIGHT DECK. NO DEFECTS NOTED AT SDR RAIA201807160002Unknown · odorPOST TO AT 180 TO 200FL AN ELECTRICAL BURNING SMELL DETECTED ON FLIGHTDECK. DEFERRED NR 1 AC PACK ON DMI 2151001. MORE INFORMATION SENT WHEN AVAILABLE.SDR RAIA2018060190001Motor · bindingFIRST OFFICER'S WINDSHIELD WIPER STOPPED MID WIPE. REMOVED AND REPLACED THE WINDSHIELD WIPER MOTOR. OPS CHECKED GOOD. OPEN.SDR RAIA201709020001Door Sill · corrodedCARGO DOOR SILL IS CORRODED AT THE FORWARD END. R & R THE DOOR SILL.SDR RAIA201708150002Lens · crackedEMERGENCY LIGHT LENS CRACKED. R & R THE LENS. OPS CHECKED GOOD.SDR RAIA201611100001Light · inoperativeEMERGENCY LIGHT AT ROWS 8 - 11, FOUND INOPERATIVE. REPAIRED THE WIRING. OPS CHECKED GOOD.SDR RAIA201611100002Bulb · inoperativeEMERGENCY LIGHT IN CEILING BY SERVICE DOOR IS INOPERATIVE. R & R THE BULB, EMERGENCY LIGHT OPS CHECKED GOOD.SDR RAIA201601310002Cabin Pressure · malfunctionedACFT WILL NOT PRESSURIZE ON AUTO OR MANUAL MODE IN THE AIR ACFT RETURNED FROM FLIGHT. COMPLIED WITH REACTIVATION PROCEDURE. OPS CHECKED GOOD.SDR RAIA201511170001Connector · unsecureRIGHT OVERWING EMERGENCY EXIT MARKER NR 24 INOPERATIVE. RESEATED GRAND CONNECTOR OF EMERGENCY LIGHT. OPS CHECK GOOD.SDR RAIA20151011002Bulb · inoperativePASSENGER DOOR EMERGENCY FLOOD LIGHT NR 1 INOPERATIVE. R & R PAX DOOR EMERGENCY FLOOD LIGHT NR 1. OPS CHECK GOOD.SDR RAIA201510110001Bulb · inoperativeLEFT FWD EXTERIOR EMERGENCY FLOOD LIGHT NR 3 INOPERATIVE. R & R FWD EXTERIOR EMERGENCY FLOOD LIGHT NR 3. OPS CHECK GOOD.SDR RAIA201509020002Cabin Pressure · malfunctionedGRADUAL LOSS OF PRESSURIZATION AT FL 370. OPEN