N613AE

Service difficulty reports · 217

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N613AE' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SIMA20230326001Flashlight Assy · brokenAFT FLASHLIGHT CRADLE BROKEN-C/A-RAR AFT FLASHLIGHT ASSY IAW EMB AMM 33-50-16-000-801-A AND 33-50-16-400-801-A. OPC GOOD. END.Mar 26, 2023 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20230304002None · noneELECTRICAL BURNING SMELL IN PLANE. APU NOT RUNNING. GPU ATTACHED. PCA HEAT CART ATTACHED. ENGINES WERE NOT RUNNING-C/A-T/S IAW EMB 145 FIM 21-20-00-810-801-A. DUPLICATED CONDITIONS FOR OVER 1 HOUR THAT EXISTED AT TIME OF DISCREPANCY WITH PCA AIR BEING SUPPLIEDMar 4, 2023 · N613AE · Emb EMB145LR · Air Distribution SystemSDR SIMA202301221001Precooler · failedBLEED 1 OVERTEMP ON CLIMBOUTAND DURING DECENT INTO ORD, ANTI ICE INOP MESSAGE REPORTED A BLEED 1 OVERTEMP ENROUTE, FLT DECLARED EMERGENCY DUE TO ICING CONDITIONS AND LANDED SAFELY. REPLACED NR 1 PRECOOLER IAW AMM 36-11-04 REF NRWC 613-ORD-05129 ITEM 2 FOR PREJan 21, 2023 · N613AE · Emb EMB145LR · Pneumatic Distribution SystemSDR SIMA20230112002Wheel · failedBLOWN LEFT OUTBOARD TIRE ON TAKEOFF AFTER 90 KNOTS AND SMELLED RUBBER. SUSPECTED POSSIBLE TIRE FAILURE. POST FLIGHT WALK AROUND REVEALED LEFT OUTER TIRE DAMAGED. EMERGENCY DECLARED. -C/A-FOUND #1 MLG TIRE TREAD FAILED. RAR #1 MLG TIRE IAW WC 32-700-11.Jan 12, 2023 · N613AE · Emb EMB145LR · Wheel/Ski/FloatSDR SIMA20221031004Light · unserviceableDURING PS-1 CHECK FOUND EXTERNAL EMERGENCY LIGHT RH OVERWING INOP-C/A-RAR EXTERNAL EMERGENCY LIGHT ASSEMBLY RH OVERWING IAW EMB 145 AMM 33-50-10, OPS CHECK GOOD IAW EMB 145 AMM 33-50-00 NO FURTHER DEFECTS NOTED AT THIS TIMEOct 31, 2022 · N613AE · Emb EMB145 · Emergency LightingSDR SIMA20221015001Lamp · inoperativeR/H OVERWING EMERGENCY LIGHT INOP-C/A-REPLACED EMERGENCY LIGHTY LAMP IAW AMM 33-50-10.OPS CHECK GOODOct 15, 2022 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20221007001Lamp · inoperativeDURING PS-1 CHECK, FOUND RH OVER WING EMERGENCY LIGHT INOP-C/A-RAR OVER WING EXTERIOR EMERGENCY LIGHT LAMP IAW EMB 145 AMM 33-50-07. OPC GOODOct 7, 2022 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20220909001Lamp · inoperativeRH OVER WING EMERGENCY LIGHT INOP-C/A-RAR RH OVER WING EMERGENCY LIGHT LAMP WITH REFERENCE TO EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.Sep 9, 2022 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20220807001Light · inoperativeFLOOR EMERGENCY LIGHT STRIP INOP AT ROW 8 AND 9.-C/A-REPAIRED QUICK DISCONECT ON FLOOR EMERGENCY LIGHTING STRIP IAW SWPM 20-50-00 AND OPC GOOD IAW AMM 33-50-00.Aug 7, 2022 · N613AE · Emb ERJ170200LR · Emergency LightingSDR SIMA20220807002Light · inoperativeRH OVERWING EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING EMERGENCYT LIGHT LAMP IAW AMM 33-50-10 OPC GOODAug 7, 2022 · N613AE · Emb ERJ170200LR · Emergency LightingSDR SIMA20220614001Lamp · inoperativeRH OVERWING EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING EMERGENCY LAMP IAW AMM 33-50-07-000-801-A AND 33-50-07-400-801-A. OPS CHECK GOOD. END.Jun 14, 2022 · N613AE · Emb ERJ170200LR · Emergency LightingSDR SIMA20220530004None · noneRUBBER BURNING SMELL INSIDE CABIN WENT AWAY AFTER LANDING COMPLETION OF FIM TASK 21-20-00-810-801-A REF AML 4815459 ITEM 3 REQUIRED-C/A-CA PENDINGMay 30, 2022 · N613AE · Emb EMB145LR · Air Distribution SystemSDR SIMA20220521003Lamp · inoperativeFOUND RH OVERWING REAR EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING REAR EMERGENCY LIGHT BULB IAW EMB145 AMM 33-50-10. OPC GOOD.May 21, 2022 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20220505002Lamp · inoperativeRH OVERWING EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING EMERGENCY LAMP IAW AMM 33-50-07-000-801-A AND 33-50-07-400-801-A. OPS CHECK GOOD. END.May 5, 2022 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20220505001None · brokenFWD FA FLASHLIGHT CRADLE BROKEN-C/A-RAR FWD FA FLISHLIGHT CRADLE IAW CMM 25-60-14. OPS CHECK GOOD. NO DEFECTS NOTED. END.May 5, 2022 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20220501002Lamp · inoperativeRIGHT HAND OVER WING EXTERIOR EMERGENCY LIGHT INOP-C/A-RAR BULB IAW AMM 33-50-10, OPS CHECK GOODMay 1, 2022 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20220422001None · unserviceableELECTRICAL SMOKE IN COCKPIT LOW VIB SOUND LIKE MAY BE A BAD FAN MOTOR.FOUND LH AVI EXHAUST FAN INOPERATIVE. TROUBLE SHOOTING ITEM #1 LGPG 4878054,-C/A-REMOVED AND REPLACED LH AVI EXHAUST FAN IAW EMB 145 AMM 21-26-02 OPS TEST GOODApr 22, 2022 · N613AE · Emb EMB145LR · Air Distribution SystemSDR SIMA20220407001Lamp · inoperativeRH OVERWING EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING EMERGENCY LAMP IAW AMM 33-50-07-000-801-A AND 33-50-07-400-801-A. OPS CHECK GOOD. END.Apr 7, 2022 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20220223001None · noneEMERGENCY LIGHTING FLOOR STRIPS 2 AND 3 INOP.-C/A-RAR BATTERY AND CHARGER #2 OPC BAD IAW WC 33-700-19. SEE ITEM 2 THIS NRWCFeb 23, 2022 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20220209001None · noneROW 8A EMERGENCY FLOOR STRIP WONT ILLUMINATE ORIGINAL LOGPAGE 4715621 ITEM 3 MEL 3323 - AUTH# 02-53-C-C/A-RAR ROW 8A EMERGENCY FLOOR LT STRIP IAW EMB AMM 33-50-12-000-801-A AND 33-50-12-400-801-A. OPS CHECK GOOD. MEL RESTORED. END.Feb 9, 2022 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20220205001None · none"TRANSFERRED FROM NRWC 613-CMI-04165 ITEM 1" ROW 8A EMERGENCY LIGHT STRIP INOP-C/A-DEFERRED PER MEL 33-23. AUTH# 020053-CFeb 5, 2022 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20211212004None · noneFOUND FA FLASHLIGHT ASSEMBLY TO BE UNSERVICEABLE PER PS-2 CHECK-C/A-REMOVED AND REPLACED FA FLASHLIGHT ASSEMBLY IAW EMB 145 AMM 33-51-01. OPS CHECK GOOD.Dec 12, 2021 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20211117005Smoke Detector · false activationSMOKE INDICATION IN THE CARGO BAY BAGGAGE COMPT SMOKE DETECTION SYSTEM REQS MEL 26-3 DUE TO LACK OF EVIDENCE OF FIRE MEL 2603 - AUTH# 11-255D-C-C/A-REF LG PG 4832556 ITEM 3 RAR CARGO SMOKE DETECTOR IAW AMM 26-15-00. OPS CHECK GOOD. MEL ITEM CLOSED.Nov 17, 2021 · N613AE · Emb EMB145LR · Smoke DetectionSDR SIMA20211024001None · noneLH WINDSHIELD OUTER LAYER CRACKED AT 15K DECLARED EMERGENCY "TRANSFERRED TO NRWC 613-ORD-03900"-C/A-REF NRWC 613-ORD-03900 FOR CORRECTIVE ACTION AND APPLICABLE RII. RAR CAPT WINDSHIELD. ALL OPS/LEAK TESTS GOOD. NO DEFECTS NOTED.Oct 24, 2021 · N613AE · Emb EMB145LR · Flight Compartment WindowsSDR SIMA20211012006None · noneRH OVERWING AFT EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING AFT EMERGENCY LIGHT LAMP IAW AMM 33-50-10. OPERATIONAL CHECK GOOD.Oct 12, 2021 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20210924002None · noneLH SIDE OVER THE WING EMER.LIGHT INOP.-C/A-RAR LH SIDE OVER THE WING EMER.LIGHT BULB IAW EMB 145 AMM 33-50-10..OPERATIONAL CHECK GOOD.Sep 24, 2021 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA202108298001Inverter · inoperativeSEAT 12A EMERGENCY EXIT PLACARD INOP-C/A-T/S IAW FIM TASK 33-50-00-810-804-A. RAR EMERGENCY LIGHT DC/AC INVERTER 5 IAW EMB AMM 33-50-11-000-801-A AND 33-50-11-400-801-A OPS CHECK GOODAug 28, 2021 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20210817006Muffler · disconnectedPAX COMPLAINING OF A SMOKE SMELL IN THE AFT HALF OF THE CABIN."TRANSFERRED TO NRWC 613-DFW-03690-C/A-FOUND MUFFLER CONNECTING RECIRC. FAN 2 AND PACK 2 TO BE DISCONNECTED. REINSTALLED MUFFLER TO RECIRCULATION FAN 2 AND FUSELAGE FITTING IAW EMB 145 AMM 21-24-02.Aug 17, 2021 · N613AE · Emb EMB145LR · Air Distribution FanSDR SIMA202108197005Wire · brokenEMERGENCY LIGHT FLOOR STRIP AT FLOOR PANEL 261BF WIRE BROKEN-C/A-RAR EMEREGNCY LIGHT FLOOR STRIP IAW AMM 33-50-12 OPERATIONAL CHECK GOODAug 17, 2021 · N613AE · Emb EMB145LR · Light System WiringSDR SIMA20210806001Bulb · inoperativeRH OVERWING LATERAL PANEL EMERGENCY LIGHT INOP.-C/A-RAR RH OVERWING LATERAL PANEL EMERGENCY LIGHT BULB IAW AMM 33-50-10. OPC GOOD.Aug 6, 2021 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20210802001Lamp · inoperativeDURING PS1 CHECK FOUND LH UPPER FAIRING EMERGENCY LIGHT OUT-C/A-RAR LH UPPER FAIRING LAMP IAW EMB 145 AMM 33-50-10. OPS CHECK GOOD.Aug 2, 2021 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20210718001Light · inoperativeROW 12 EMERGENCY LIGHTS INOP-C/A-T/S IAW FIM TASK 33-50-00-810-804-A. RAR BATTERY CHARGER ASSY AND BATTERY PACK IAW EMB AMM 33-50-04-000-801-A AND 33-50-04-400-801-A AND 33-50-04-000-802-A AND 33-50-04-400-802-A OPS CHECK GOODJul 18, 2021 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20210701001Battery Pack · inoperativeROWS 8-12 EMERGENCY LIGHTS INOP-C/A-T/S IAW EMB FIM 33-50-00-810-804-A. FOUND #3 BATTERY BAD. RAR #3 BATTERY AND CHARGER IAW ENVOY W/C 33-700-19. OPS CHECK GOOD. NO DEFECTS NOTED. END.Jul 1, 2021 · N613AE · Emb EMB145 · Emergency LightingSDR SIMA20210625001Lamp · inoperativeDURING PS-1 CHECK FOUND RH SIDE CENTER FAIRING EMERGENCY LIGHT INOP-C/A-RAR RH SIDE CENTER FAIRING EMERGENCY LAMP IAW EMB AMM 33-50-10. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED AT THIS TIME.Jun 25, 2021 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20210624002Unknown · smokeDURING DESCENT WE SMELT ELECTRICAL SMOKE SMELL IN COCKPIT. FLIGHT ATTENDANT CONFIRMED SMELL IN CABIN-C/A-T/S PER WORKSCOPE AND FIM 21-20-00-810-801-A AND FOUND NO DEFECTS AT THIS TIMEJun 24, 2021 · N613AE · Emb EMB145LR · Air Distribution SystemSDR SIMA20210616001Transducer · faultedENG 1 LOSS OF OIL PRESS IND DURING TAKEOFF ROLL (LOW SPEED REJECT ABOUT 40 KTS). THERE WAS NO EICAS "E1 OIL LOW PRESS" MESSAGE. OIL PSI WENT TO MOSTLY 6 PSI.-C/A-RAR OIL TEMPERATURE/PRESSURE SENSOR TRANSDUCER IAW AMM 79-31-01. PERFORMED OPERATIONAL CHECK. DID Jun 16, 2021 · N613AE · Emb EMB145LR · Engine Oil Indicating SystemSDR SIMA20210603003Radio Altimeter · faultedCLIMBING THROUGH 15,000FT RA MOMENTARILY STUCK AT 20FT AND GOT TO LOW TERRAIN AURAL WARNING.-C/A-DEFERRED PER MEL 34-8 AUTH # 060025 DM-A EXP 6-5-21 ?M? PROCEDURES C/WJun 3, 2021 · N613AE · Emb EMB145LR · Doppler SystemSDR SIMA20210524001Battery Pack · inoperativeEMERGENCY LIGHT STRIPS 4 AND 5 AND LH AND RH LOWER DOOR SHROUD EXIT PLACARDS NOT ILLUMINATING-C/A-RAR #3 BATTERY AND POWER SUPPLY IAW AMM 33-50-04 OPS CHECK FAIL PERFORMED ELECTRICAL POWER RESET OPS CHECK GOOD.May 24, 2021 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20210417003Bulb · inoperativeLEFT HAND OVER WING EMERGANCY LIGHT INOP-C/A-REMOVED AND REPLACED LEFT HAND OVER WING EMERGANCY LIGHT BULB IAW AMM 33-50-10. OPERATIONAL CHECK GOOD.Apr 17, 2021 · N613AE · Emb EMB145 · Emergency LightingSDR SIMA20210203001Lamp · inoperativeRH EXTERNAL OVERWING EMERGENCY LIGHT INOP-C/A-RAR RH EXTERNAL OVERWING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.Feb 3, 2021 · N613AE · Emb EMB145LR · Emergency LightingSDR SIMA20210125002Structure · crackedTHE COCKPIT RT DIAGONAL CEILING MEMBER IS CRACKED JUST FORWARD OF THE SPEAKER, AS MARKED. C/A: R & R COCKPIT RT DIAGONAL CEILING MEMBER, IAW EMB 145 SRM 51-40-02. REPLACEMENT PN: 123-07751-006.Jan 25, 2021 · N613AE · Emb EMB145 · Fuselage Main, StructureSDR SIMA20210105003Yoke · crackedDURING IMBV INSPECTION, QC FOUND RT PYLON FWD LOWER YOKE FITTING CRACKED. C/A: REMOVED AND REPLACED RT FWD LOWER YOKE FITTING, IAW ERS-EM-54MR-698.Jan 5, 2021 · N613AE · Emb EMB145 · Nacelle/Pylon, Attach FittingsSDR SIMA20201223003Floor Support · corrodedLT OMEGA BEAM AT FRAME 20 PREVIOUS REPAIR IS CORRODED. C/A: REACCOMPLISHED REPAIR ON LT OMEGA BEAM AT FRAME 20, IAW EMB 145 SRM 53-00-10RE.Dec 23, 2020 · N613AE · Emb EMB145 · Fuselage Miscellaneous StructureSDR SIMA20201222003Shear Tie · corrodedCARGO DOOR CUTOUT STRUCTURE FR 65 SHEAR CLIP CORRODED. LEVEL 1 CORROSION. C/A: PERFORMED A PERMANENT REPAIR ON THE CARGO DOOR CUTOUT STRUCTURE FR 65 LOWER END OF THE SHEAR CLIP, IAW EMB 145 SRM 53-31-04 ITEM 4 FIGURE 212.Dec 22, 2020 · N613AE · Emb EMB145LR · Fuselage Internal Mounting StructureSDR SIMA20201222002Floor Support · corrodedCARGO DOOR CUTOUT STRUCTURE LOWER FLOOR SILL CORRODED. LEVEL 1 CORROSION. C/A: REMOVED AND REPLACED THE CARGO DOOR CUTOUT STRUCTURE LOWER FLOOR SILL, IAW EMB 145 SRM 51-40-02.Dec 22, 2020 · N613AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20201221002Support · corrodedTOILET WASTE VALVE SUPPORT EXTERIOR HAS CORROSION. C/A: REMOVED AND REPLACED THE TOILET WASTE VALVE SUPPORT, IAW EMB 145 SRM 51-40-02.Dec 21, 2020 · N613AE · Emb EMB145 · Fuselage Miscellaneous StructureSDR SIMA20201220007Spar · crackedLT WING SPAR I CRACKED AT RIB 9. CRACK LENGHT 0.3 NUMBER OF CRACKS 1. C/A: ACCOMPLISHED PERMANENT REPAIR ON LT WING SPAR I AT RIB 9, IAW EMB 145 SRM 57-20-05 ITEM 3.Dec 20, 2020 · N613AE · Emb EMB145 · Wing SparSDR SIMA20201220006Skin · crackedBAGGAGE DOOR EXTERNAL SKIN ACTUATING HANDLE CUTOUT EDGE HAS 2 CRACKS, 0.3 IN LENGTH. C/A: ACCOMPLISHED A PERMANENT REPAIR ON CRACKS ON THE BAGGAGE DOOR EXTERNAL SKIN ACTUATING HANDLE CUTOUT WITH CUTOUT DOUBLER AND FILLER, IAW ERS-EM-52MR-1103.Dec 20, 2020 · N613AE · Emb EMB145LR · Cargo/Baggage DoorsSDR SIMA20201220005Skin · crackedFUSELAGE SKIN CRACKS AROUND 2 RIVETS AT FRAME 75 BETWEEN STGR 01R-02R. C/A: ACCOMPLISHED PERMANENT REPAIR ON FUSELAGE SKIN CRACKS AT FRAME 75 BETWEEN STRINGERS 01R-02R, IAW EMB 145 SRM 53-31-01RE FIGURE 219 SHEET 2.Dec 20, 2020 · N613AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20201220004Profile · corrodedRT EMERGENCY EXIT LOWER PROFILE L UNDER AFT TEFLON GUIDE CORRODED. LEVEL 2 CORROSION. C/A: REMOVED AND REPLACED RT EMERGENCY EXIT LOWER L PROFILE, IAW EMB 145 SRM 51-20-03 AND 51-40-02.Dec 20, 2020 · N613AE · Emb EMB145LR · Emergency Exits
Back to N613AE