N613AE
Service difficulty reports · 217
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N613AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N613AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20230326001Flashlight Assy · brokenAFT FLASHLIGHT CRADLE BROKEN-C/A-RAR AFT FLASHLIGHT ASSY IAW EMB AMM 33-50-16-000-801-A AND 33-50-16-400-801-A. OPC GOOD. END.SDR SIMA20230304002None · noneELECTRICAL BURNING SMELL IN PLANE. APU NOT RUNNING. GPU ATTACHED. PCA HEAT CART ATTACHED. ENGINES WERE NOT RUNNING-C/A-T/S IAW EMB 145 FIM 21-20-00-810-801-A. DUPLICATED CONDITIONS FOR OVER 1 HOUR THAT EXISTED AT TIME OF DISCREPANCY WITH PCA AIR BEING SUPPLIEDSDR SIMA202301221001Precooler · failedBLEED 1 OVERTEMP ON CLIMBOUTAND DURING DECENT INTO ORD, ANTI ICE INOP MESSAGE REPORTED A BLEED 1 OVERTEMP ENROUTE, FLT DECLARED EMERGENCY DUE TO ICING CONDITIONS AND LANDED SAFELY. REPLACED NR 1 PRECOOLER IAW AMM 36-11-04 REF NRWC 613-ORD-05129 ITEM 2 FOR PRESDR SIMA20230112002Wheel · failedBLOWN LEFT OUTBOARD TIRE ON TAKEOFF AFTER 90 KNOTS AND SMELLED RUBBER. SUSPECTED POSSIBLE TIRE FAILURE. POST FLIGHT WALK AROUND REVEALED LEFT OUTER TIRE DAMAGED. EMERGENCY DECLARED. -C/A-FOUND #1 MLG TIRE TREAD FAILED. RAR #1 MLG TIRE IAW WC 32-700-11.SDR SIMA20221031004Light · unserviceableDURING PS-1 CHECK FOUND EXTERNAL EMERGENCY LIGHT RH OVERWING INOP-C/A-RAR EXTERNAL EMERGENCY LIGHT ASSEMBLY RH OVERWING IAW EMB 145 AMM 33-50-10, OPS CHECK GOOD IAW EMB 145 AMM 33-50-00 NO FURTHER DEFECTS NOTED AT THIS TIMESDR SIMA20221015001Lamp · inoperativeR/H OVERWING EMERGENCY LIGHT INOP-C/A-REPLACED EMERGENCY LIGHTY LAMP IAW AMM 33-50-10.OPS CHECK GOODSDR SIMA20221007001Lamp · inoperativeDURING PS-1 CHECK, FOUND RH OVER WING EMERGENCY LIGHT INOP-C/A-RAR OVER WING EXTERIOR EMERGENCY LIGHT LAMP IAW EMB 145 AMM 33-50-07. OPC GOODSDR SIMA20220909001Lamp · inoperativeRH OVER WING EMERGENCY LIGHT INOP-C/A-RAR RH OVER WING EMERGENCY LIGHT LAMP WITH REFERENCE TO EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.SDR SIMA20220807001Light · inoperativeFLOOR EMERGENCY LIGHT STRIP INOP AT ROW 8 AND 9.-C/A-REPAIRED QUICK DISCONECT ON FLOOR EMERGENCY LIGHTING STRIP IAW SWPM 20-50-00 AND OPC GOOD IAW AMM 33-50-00.SDR SIMA20220807002Light · inoperativeRH OVERWING EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING EMERGENCYT LIGHT LAMP IAW AMM 33-50-10 OPC GOODSDR SIMA20220614001Lamp · inoperativeRH OVERWING EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING EMERGENCY LAMP IAW AMM 33-50-07-000-801-A AND 33-50-07-400-801-A. OPS CHECK GOOD. END.SDR SIMA20220530004None · noneRUBBER BURNING SMELL INSIDE CABIN WENT AWAY AFTER LANDING COMPLETION OF FIM TASK 21-20-00-810-801-A REF AML 4815459 ITEM 3 REQUIRED-C/A-CA PENDINGSDR SIMA20220521003Lamp · inoperativeFOUND RH OVERWING REAR EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING REAR EMERGENCY LIGHT BULB IAW EMB145 AMM 33-50-10. OPC GOOD.SDR SIMA20220505002Lamp · inoperativeRH OVERWING EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING EMERGENCY LAMP IAW AMM 33-50-07-000-801-A AND 33-50-07-400-801-A. OPS CHECK GOOD. END.SDR SIMA20220505001None · brokenFWD FA FLASHLIGHT CRADLE BROKEN-C/A-RAR FWD FA FLISHLIGHT CRADLE IAW CMM 25-60-14. OPS CHECK GOOD. NO DEFECTS NOTED. END.SDR SIMA20220501002Lamp · inoperativeRIGHT HAND OVER WING EXTERIOR EMERGENCY LIGHT INOP-C/A-RAR BULB IAW AMM 33-50-10, OPS CHECK GOODSDR SIMA20220422001None · unserviceableELECTRICAL SMOKE IN COCKPIT LOW VIB SOUND LIKE MAY BE A BAD FAN MOTOR.FOUND LH AVI EXHAUST FAN INOPERATIVE. TROUBLE SHOOTING ITEM #1 LGPG 4878054,-C/A-REMOVED AND REPLACED LH AVI EXHAUST FAN IAW EMB 145 AMM 21-26-02 OPS TEST GOODSDR SIMA20220407001Lamp · inoperativeRH OVERWING EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING EMERGENCY LAMP IAW AMM 33-50-07-000-801-A AND 33-50-07-400-801-A. OPS CHECK GOOD. END.SDR SIMA20220223001None · noneEMERGENCY LIGHTING FLOOR STRIPS 2 AND 3 INOP.-C/A-RAR BATTERY AND CHARGER #2 OPC BAD IAW WC 33-700-19. SEE ITEM 2 THIS NRWCSDR SIMA20220209001None · noneROW 8A EMERGENCY FLOOR STRIP WONT ILLUMINATE ORIGINAL LOGPAGE 4715621 ITEM 3 MEL 3323 - AUTH# 02-53-C-C/A-RAR ROW 8A EMERGENCY FLOOR LT STRIP IAW EMB AMM 33-50-12-000-801-A AND 33-50-12-400-801-A. OPS CHECK GOOD. MEL RESTORED. END.SDR SIMA20220205001None · none"TRANSFERRED FROM NRWC 613-CMI-04165 ITEM 1" ROW 8A EMERGENCY LIGHT STRIP INOP-C/A-DEFERRED PER MEL 33-23. AUTH# 020053-CSDR SIMA20211212004None · noneFOUND FA FLASHLIGHT ASSEMBLY TO BE UNSERVICEABLE PER PS-2 CHECK-C/A-REMOVED AND REPLACED FA FLASHLIGHT ASSEMBLY IAW EMB 145 AMM 33-51-01. OPS CHECK GOOD.SDR SIMA20211117005Smoke Detector · false activationSMOKE INDICATION IN THE CARGO BAY BAGGAGE COMPT SMOKE DETECTION SYSTEM REQS MEL 26-3 DUE TO LACK OF EVIDENCE OF FIRE MEL 2603 - AUTH# 11-255D-C-C/A-REF LG PG 4832556 ITEM 3 RAR CARGO SMOKE DETECTOR IAW AMM 26-15-00. OPS CHECK GOOD. MEL ITEM CLOSED.SDR SIMA20211024001None · noneLH WINDSHIELD OUTER LAYER CRACKED AT 15K DECLARED EMERGENCY "TRANSFERRED TO NRWC 613-ORD-03900"-C/A-REF NRWC 613-ORD-03900 FOR CORRECTIVE ACTION AND APPLICABLE RII. RAR CAPT WINDSHIELD. ALL OPS/LEAK TESTS GOOD. NO DEFECTS NOTED.SDR SIMA20211012006None · noneRH OVERWING AFT EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING AFT EMERGENCY LIGHT LAMP IAW AMM 33-50-10. OPERATIONAL CHECK GOOD.SDR SIMA20210924002None · noneLH SIDE OVER THE WING EMER.LIGHT INOP.-C/A-RAR LH SIDE OVER THE WING EMER.LIGHT BULB IAW EMB 145 AMM 33-50-10..OPERATIONAL CHECK GOOD.SDR SIMA202108298001Inverter · inoperativeSEAT 12A EMERGENCY EXIT PLACARD INOP-C/A-T/S IAW FIM TASK 33-50-00-810-804-A. RAR EMERGENCY LIGHT DC/AC INVERTER 5 IAW EMB AMM 33-50-11-000-801-A AND 33-50-11-400-801-A OPS CHECK GOODSDR SIMA20210817006Muffler · disconnectedPAX COMPLAINING OF A SMOKE SMELL IN THE AFT HALF OF THE CABIN."TRANSFERRED TO NRWC 613-DFW-03690-C/A-FOUND MUFFLER CONNECTING RECIRC. FAN 2 AND PACK 2 TO BE DISCONNECTED. REINSTALLED MUFFLER TO RECIRCULATION FAN 2 AND FUSELAGE FITTING IAW EMB 145 AMM 21-24-02.SDR SIMA202108197005Wire · brokenEMERGENCY LIGHT FLOOR STRIP AT FLOOR PANEL 261BF WIRE BROKEN-C/A-RAR EMEREGNCY LIGHT FLOOR STRIP IAW AMM 33-50-12 OPERATIONAL CHECK GOODSDR SIMA20210806001Bulb · inoperativeRH OVERWING LATERAL PANEL EMERGENCY LIGHT INOP.-C/A-RAR RH OVERWING LATERAL PANEL EMERGENCY LIGHT BULB IAW AMM 33-50-10. OPC GOOD.SDR SIMA20210802001Lamp · inoperativeDURING PS1 CHECK FOUND LH UPPER FAIRING EMERGENCY LIGHT OUT-C/A-RAR LH UPPER FAIRING LAMP IAW EMB 145 AMM 33-50-10. OPS CHECK GOOD.SDR SIMA20210718001Light · inoperativeROW 12 EMERGENCY LIGHTS INOP-C/A-T/S IAW FIM TASK 33-50-00-810-804-A. RAR BATTERY CHARGER ASSY AND BATTERY PACK IAW EMB AMM 33-50-04-000-801-A AND 33-50-04-400-801-A AND 33-50-04-000-802-A AND 33-50-04-400-802-A OPS CHECK GOODSDR SIMA20210701001Battery Pack · inoperativeROWS 8-12 EMERGENCY LIGHTS INOP-C/A-T/S IAW EMB FIM 33-50-00-810-804-A. FOUND #3 BATTERY BAD. RAR #3 BATTERY AND CHARGER IAW ENVOY W/C 33-700-19. OPS CHECK GOOD. NO DEFECTS NOTED. END.SDR SIMA20210625001Lamp · inoperativeDURING PS-1 CHECK FOUND RH SIDE CENTER FAIRING EMERGENCY LIGHT INOP-C/A-RAR RH SIDE CENTER FAIRING EMERGENCY LAMP IAW EMB AMM 33-50-10. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED AT THIS TIME.SDR SIMA20210624002Unknown · smokeDURING DESCENT WE SMELT ELECTRICAL SMOKE SMELL IN COCKPIT. FLIGHT ATTENDANT CONFIRMED SMELL IN CABIN-C/A-T/S PER WORKSCOPE AND FIM 21-20-00-810-801-A AND FOUND NO DEFECTS AT THIS TIMESDR SIMA20210616001Transducer · faultedENG 1 LOSS OF OIL PRESS IND DURING TAKEOFF ROLL (LOW SPEED REJECT ABOUT 40 KTS). THERE WAS NO EICAS "E1 OIL LOW PRESS" MESSAGE. OIL PSI WENT TO MOSTLY 6 PSI.-C/A-RAR OIL TEMPERATURE/PRESSURE SENSOR TRANSDUCER IAW AMM 79-31-01. PERFORMED OPERATIONAL CHECK. DID SDR SIMA20210603003Radio Altimeter · faultedCLIMBING THROUGH 15,000FT RA MOMENTARILY STUCK AT 20FT AND GOT TO LOW TERRAIN AURAL WARNING.-C/A-DEFERRED PER MEL 34-8 AUTH # 060025 DM-A EXP 6-5-21 ?M? PROCEDURES C/WSDR SIMA20210524001Battery Pack · inoperativeEMERGENCY LIGHT STRIPS 4 AND 5 AND LH AND RH LOWER DOOR SHROUD EXIT PLACARDS NOT ILLUMINATING-C/A-RAR #3 BATTERY AND POWER SUPPLY IAW AMM 33-50-04 OPS CHECK FAIL PERFORMED ELECTRICAL POWER RESET OPS CHECK GOOD.SDR SIMA20210417003Bulb · inoperativeLEFT HAND OVER WING EMERGANCY LIGHT INOP-C/A-REMOVED AND REPLACED LEFT HAND OVER WING EMERGANCY LIGHT BULB IAW AMM 33-50-10. OPERATIONAL CHECK GOOD.SDR SIMA20210203001Lamp · inoperativeRH EXTERNAL OVERWING EMERGENCY LIGHT INOP-C/A-RAR RH EXTERNAL OVERWING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.SDR SIMA20210125002Structure · crackedTHE COCKPIT RT DIAGONAL CEILING MEMBER IS CRACKED JUST FORWARD OF THE SPEAKER, AS MARKED. C/A: R & R COCKPIT RT DIAGONAL CEILING MEMBER, IAW EMB 145 SRM 51-40-02. REPLACEMENT PN: 123-07751-006.SDR SIMA20210105003Yoke · crackedDURING IMBV INSPECTION, QC FOUND RT PYLON FWD LOWER YOKE FITTING CRACKED. C/A: REMOVED AND REPLACED RT FWD LOWER YOKE FITTING, IAW ERS-EM-54MR-698.SDR SIMA20201223003Floor Support · corrodedLT OMEGA BEAM AT FRAME 20 PREVIOUS REPAIR IS CORRODED. C/A: REACCOMPLISHED REPAIR ON LT OMEGA BEAM AT FRAME 20, IAW EMB 145 SRM 53-00-10RE.SDR SIMA20201222003Shear Tie · corrodedCARGO DOOR CUTOUT STRUCTURE FR 65 SHEAR CLIP CORRODED. LEVEL 1 CORROSION. C/A: PERFORMED A PERMANENT REPAIR ON THE CARGO DOOR CUTOUT STRUCTURE FR 65 LOWER END OF THE SHEAR CLIP, IAW EMB 145 SRM 53-31-04 ITEM 4 FIGURE 212.SDR SIMA20201222002Floor Support · corrodedCARGO DOOR CUTOUT STRUCTURE LOWER FLOOR SILL CORRODED. LEVEL 1 CORROSION. C/A: REMOVED AND REPLACED THE CARGO DOOR CUTOUT STRUCTURE LOWER FLOOR SILL, IAW EMB 145 SRM 51-40-02.SDR SIMA20201221002Support · corrodedTOILET WASTE VALVE SUPPORT EXTERIOR HAS CORROSION. C/A: REMOVED AND REPLACED THE TOILET WASTE VALVE SUPPORT, IAW EMB 145 SRM 51-40-02.SDR SIMA20201220007Spar · crackedLT WING SPAR I CRACKED AT RIB 9. CRACK LENGHT 0.3 NUMBER OF CRACKS 1. C/A: ACCOMPLISHED PERMANENT REPAIR ON LT WING SPAR I AT RIB 9, IAW EMB 145 SRM 57-20-05 ITEM 3.SDR SIMA20201220006Skin · crackedBAGGAGE DOOR EXTERNAL SKIN ACTUATING HANDLE CUTOUT EDGE HAS 2 CRACKS, 0.3 IN LENGTH. C/A: ACCOMPLISHED A PERMANENT REPAIR ON CRACKS ON THE BAGGAGE DOOR EXTERNAL SKIN ACTUATING HANDLE CUTOUT WITH CUTOUT DOUBLER AND FILLER, IAW ERS-EM-52MR-1103.SDR SIMA20201220005Skin · crackedFUSELAGE SKIN CRACKS AROUND 2 RIVETS AT FRAME 75 BETWEEN STGR 01R-02R. C/A: ACCOMPLISHED PERMANENT REPAIR ON FUSELAGE SKIN CRACKS AT FRAME 75 BETWEEN STRINGERS 01R-02R, IAW EMB 145 SRM 53-31-01RE FIGURE 219 SHEET 2.SDR SIMA20201220004Profile · corrodedRT EMERGENCY EXIT LOWER PROFILE L UNDER AFT TEFLON GUIDE CORRODED. LEVEL 2 CORROSION. C/A: REMOVED AND REPLACED RT EMERGENCY EXIT LOWER L PROFILE, IAW EMB 145 SRM 51-20-03 AND 51-40-02.