What was found
CARGO DOOR CUTOUT STRUCTURE FR 65 SHEAR CLIP CORRODED. LEVEL 1 CORROSION. C/A: PERFORMED A PERMANENT REPAIR ON THE CARGO DOOR CUTOUT STRUCTURE FR 65 LOWER END OF THE SHEAR CLIP, IAW EMB 145 SRM 53-31-04 ITEM 4 FIGURE 212.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CARGO DOOR CUTOUT STRUCTURE FR 65 SHEAR CLIP CORRODED. LEVEL 1 CORROSION. C/A: PERFORMED A PERMANENT REPAIR ON THE CARGO DOOR CUTOUT STRUCTURE FR 65 LOWER END OF THE SHEAR CLIP, IAW EMB 145 SRM 53-31-04 ITEM 4 FIGURE 212.