N623QX

Service difficulty reports · 62

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N623QX' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR QXEA2019073100294Pressure Switch · defectiveMASTER CAUTION PRKG BRK NOT RELEASED ON DESCENT THROUGH 14,000 FT. RAN CHECKLIST IAW QRH. REMAINED ILLUMINATED AFTER CHECKLIST BUT SELF EXTINGUISHED AFTER 10 MINUTES NO ISSUES NOTED ON LANDING ROLLOUT. EMERGENCY DECLARED. LANDING UNEVENTFUL. REMOVED FROM SERVIJul 29, 2019 · N623QX · Emb ERJ170200LR · Landing Gear Brake SystemSDR QXEA2019072900289Warning System · false activationPARKG BRK NOT RELEASED CAUTION ILLUMINATED ON CAS DURING DESCENT. RAN CHECK LIST ON PAGE 13.3 AND CAS MSG EXTINGUISHED. MSG CAME BACK AND RE RAN CHECKLIST 13.3 AND MSG EXTINGUISHED AGAIN. MSG CAME BACK ON A 3RD TIME BUT EXTINGUISHED BEFORE ABLE TO RUN CHECKLISJul 27, 2019 · N623QX · Emb ERJ170200LR · Landing Gear Brake SystemSDR QXEA2019071200259Valve · malfunctionedPRKG BRK NOT RELEASED CAUTION EICAS MESSAGE ILLUMINATED DURING CRUISE FLIGHT. RAN CHECKLIST (REF PG. 13.3) LIGHT REMAINED ON. DECLARED EMERGENCY. AIRCRAFT LANDED SAFELY WITHOUT INCIDENT. REMOVED FROM SERVICE. ERFORMED PARKING BRAKE OPS CHECK PER 32-44-00-710-8Jul 9, 2019 · N623QX · Emb ERJ170200LR · Landing Gear Brake SystemSDR QXEA2019021800076Handle · stiffFLIGHT CREW REPORTS UNABLE TO MOVE R1 DOOR ARM/DISARM HANDLE INDICATION UNCLEAR. REMOVED FROM SERVICE. OPENED DOOR FROM OUTSIDE AND PERFORMED GVI OF VISIBLE MECHANISM. NO DEFECTS NOTED. CLOSED DOOR AND OPERATED ARM/DISARM HANDLE. FOUND TO BE DIFFICULT. APPLIEDFeb 18, 2019 · N623QX · Emb ERJ170200LR · Service DoorsSDR QXEA2018060400211Engine · vibrationOBSERVED THE NR 1 ENGINE VIBRATION LP 3.0 AT TAKEOFF ROLL. MONITORED VIBRATION DURING CLIMB, AND AS THE AIRCRAFT CLIMBED THROUGH FL250 FT, OBSERVED THE NR 1 LP VIBRATION TURN AMBER AND INDICATED 4.0 AU OTHER ENGINE PERIMETERS INDICATED NORMAL. COMPLIED WITH Jun 1, 2018 · N623QX · Emb ERJ170200LR · Engine (Turbine/Turboprop)SDR QXEA2017091900575Hinge · brokenL1 DOOR ARM - DEARM DOOR ASSY HINGE BROKEN. REMOVED FROM SERVICE. REMOVED & REPLACED THE HINGE IAW AMM 25-23-22-000-801-A PARA 2 A-G (2), & 25-23-22-400-801-A PARA 3A-F (2) & G. RETURNED TO SERVICE.Sep 18, 2017 · N623QX · Emb ERJ170200LR · Emergency EquipmentSDR QXEA2017081000511Indicator · out of positionAFT SERVICE DOOR GIRT BAR RED INDICATION NOT FULLY VISIBLE. REMOVED FROM SERVICE. ADJUSTED AFT SERVICE DOOR GIRT BAR INDICATOR IAW AMM 52-42-00-820-801-A SUB TASK 820-073-A FOR APPLICABLE STEPS. NO PARTS REPLACED. AIRCRAFT RETURNED TO SERVICE.Aug 10, 2017 · N623QX · Emb ERJ170200LR · Emergency EquipmentSDR QXEA2017080800509Controller · malfunctionedWINDSHIELD 2 HEATER FAILED. DIVERTED. LANDING UNEVENTFULLY. REMOVED FROM SERVICE. REMOVED AND REPLACED WINDSHIELD HEAT CONTROLLER NR 2 IAW AMM 30-42-01-000-801A, AND 30-42-01-400-801A. OPS CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE.Aug 7, 2017 · N623QX · Emb ERJ170200LR · Windshield/Door Rain/Ice RemovalSDR QXEA2017080700508Indicator · out of positionAFT SERVICE DOOR ESCAPE SLIDE GIRT RED INDICATION IS ONLY 2/3 IN VIEW.Aug 3, 2017 · N623QX · Emb ERJ170200LR · Escape SlideSDR QXEA2017061200411Bottle · low pressureAFT PASSENGER DOOR EMERGENCY OPENING PNEUMATIC ASSEMBLY PRESSURE IS LOW. SERVICED THE BOTTLE IAW AMM TASK 52-12-51-614-801-A2Jun 7, 2017 · N623QX · Emb ERJ170200LR · Passenger/Crew DoorsSDR QXEA2017053000381Bottle · low pressureL1 DOOR EMERGENCY OPENING PNEUMATIC ASSY REQUIRES SERVICING (AT 1700PSI). SERVICED L1 DOOR PNEUMATIC ASSY IAW AMM TASK 52-11-51-614-801A.May 27, 2017 · N623QX · Emb ERJ170200LR · Passenger/Crew DoorsSDR QXEA2017053000380Bottle · low pressureL2 DOOR EMERGENCY OPENING PNEUMATIC ASSY REQUIRES SERVICING (AT 1600PSI). SERVICED L2 EMERGENCY OPENING SYSTEM TO 2300 PSI IAW AMM TASK 52-12-51-614-801-A.May 27, 2017 · N623QX · Emb ERJ170200LR · Passenger/Crew Doors
Back to N623QX