N641GT
Service difficulty reports · 1,011
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N641GT' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N641GT' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2013080600432Warning Light · illuminatedLT SIDE WINDOW HEAT EICAS IN FLT.SDR UIEA2013080300429Apu · faultedAPU FAULT ON START, ACCOMPLISHED QRH PROCEDURE, BOTH START ATTEMPTS UNSUCCESSFUL. APU BITE PROCEDURE PERFORMED IAW FIM 49-11 FAULT TREE 958 FIG 105. APU STARTED ON GROUND. AT FIRST ATTEMPT, OPS CHECKED GOOD. APU OK FOR FURTHER SERVICE.SDR UIEA2013080300427Warning Message · false activationLEFT SIDE WINDOW EICAS MESSAGE, QRH PROCEDURE ACCOMPLISHED. BITE PROCEDURE CARRIED OUT IAW FIM 30-41 FAULT TREE 804. BITE TEST GOOD, PERFORMED 30-41-00/201, TASK 802 AND FOUND OK. OPS TEST C/W IAW AMM 30-41-00. OPS CHECK GOOD, OK FOR SERVICE.SDR UIEA2013080200423Unknown · odorELECTRICAL ODOR IN COCKPIT, CYCLED COCKPIT DOOR MASTER AND ODOR CEASED. VISUAL INSPECTION CARRIED OUT IAW AMM 05-51-56/201, NO EVIDENCE FOUND. FLIGHT COMPARTMENT DOOR INSPECTION CHECK CARRIED OUT IAW AMM 52-51-05/601, OPS CHECKED GOOD. OK FOR SERVICE.SDR UIEA2013072800415Apu · malfunctionedAPU WOULD NOT START AFTER THREE ATTEMPTS, AFTER LANDING. FAULT LIGHT WAS ILLUMINATED. APU BITE PROCEDURE PERFORMED IAW FIM 49-11 FAULT TREE 958, FIG 103. APU STARTED ON GROUND AT FIRST ATTEMPT AND OPS CHECKED GOOD. APU OK FOR FURTHER SERVICE.SDR UIEA2013072600412Idg · leakingNR 2 ENGINE IDG, INTEGRATED DRIVE GENERATOR, OIL LEAK, R & R NR 2 ENGINE IDG, IAW AMM 24-11-01. LEAK CHECKS GOOD. DISCONNECT FUNCTION CHECKS GOOD.SDR UIEA2013072600410Sensor · inoperativeLEFT PACK TEMP EICAS MESSAGE IN AUTOMATIC. STANDBY MODE WORKS OK. R & R COMPRESSOR OUTLET SENSOR ASSY, IAW AMM 21-51-06/401. OPS CHECKS GOOD, THIS CLEARS MDDR 41645, PLACARDS REMOVED.SDR UIEA2013072400407Warning Light · illuminatedLEFT SIDE WINDOW EICAS MESSAGE ON APPROACH AND LANDING. TROUBLESHOOTING CARRIED OUT IAW FIM 30-41-FAULT TREE 804. GROUND OPS CHECKED GOOD. WINDOW ANTI-ICE BITE TEST PERFORMED, IAW AMM 30-41-00. TEST PASS, EICAS MESSAGE AND INOPERATIVE SWITCH LIGHT EXTINGUISSDR UIEA2013071700380Warning Message · false activationAPU ISOLATION VALVE STATUS MESSAGE. TESTED SYS IAW FIM 28-25 FAULT TREE 804 & TEST PASSED.SDR UIEA2013070900361Flashlight · inoperativeFLASHLIGHT AT JUMPSEAT 2R INOPERATIVE.SDR UIEA2013070600357Tube · inoperativeNR 2 IDG INOPERATIVE. R & R 2 IDG OIL COOLING TUBE ASSY IAW AMM 24-11-04, LEAK CHECKS GOOD. THIS CLEARS MDDR 41184.SDR UIEA2013070300351Line · looseIN CRUISE FLT, RT GENERATOR DRIVE MESSAGE, ACCOMPLISHED QRH CHECKLIST. FOUND LOOSE LINE, TIGHTENED LINE IAW AMM 20-11-00, NR 2 GENERATOR RECONNECTED IAW AMM 24-11-01. LEAK CHECK AND OPS CHECKED FAILED IAW AMM 24-11-01.SDR UIEA2013070300353Deice System · inoperativeLT SIDE WINDOW HEAT INOPERATIVE IN FLIGHT. BITE TESTED WINDOW HEAT BOX IAW AMM 30-41-00. BITE TESTED GOOD.SDR UIEA2013070200348Power Supply · inoperativeFWD RT ISLE EMERGENCY LIGHTING DIM. TROUBLESHOT IAW WDM 33-51-12 AND REPLACED RT SIDE EMERGENCY LTS POWER SUPPLY OPS TEST OK.SDR UIEA2013070200349Light · missingMID CROSSOVER ISLE EMERGENCY LIGHT MISSING. REPLACED EMERGENCY LIGHT ASSY IAW WDM 33-51-12. OPS CHECK SATISFACTORY.SDR UIEA2013070100347Idg · failedGENERATOR DRIVE EICAS DURING CLIMB, CW QRH REF DDG. R & R NR 2 IDG REF MM 24-11-01-4, OPS LK CK GOOD.SDR UIEA2013062500341Indicator · inaccurate1200 POUNDS FUEL IMBALANCE AT TOP OF CLIMB BETWEEN LT & RT MAINS AFTER BURNING CTR TANK. REMAINS EQUAL AFTER BALANCING, RT MAIN TANK HAD 1200 MORE, PERFORMED FIM PROCD 28-41& NBSP; TASK 802 & FUEL QTY BITE TEST 28-41 TASK 852, NO FAULTS FOUND, NO LEAKS FOUND,SDR UIEA2013062500340Valve · failedAPU FAILED AFTER SELECTING APU BLEED TO OFF. R & R SURGE VALVE IAW AMM 49-53-01. OPS AND LEAK CHECKED OK.SDR UIEA2013061700330Overheat Sensor · failedRIGHT DUCT LEAK LIGHT ON. REPLACED RT PACK BAY OVERHEAT SENSOR IAW AMM 26-18-01-024-005-001 AND TESTED IAW AMM 26-18-00-715-001-002. ALL NOW GOOD, OK FOR SERVICE.SDR UIEA2013061500328Shutoff Valve · malfunctionedDEPARTED WITH FUEL IN ALL THREE TANKS AND ALL PUMPS ON. AT TOP OF CLIMB NOTED THAT FUEL WAS BEING USED FROM LT MAIN TANK AS WELL AS CENTER TANK. THIS LED TO A FUEL CONFIG EICAS MESSAGE. COMPLIED WITH QRH PROCEDURE, FUEL TRANSFER FEED ON, LEFT PUMP OFF WHICHSDR UIEA2013061100324Fire Bottle · inoperativeCARGO FIRE BOTTLE ONE LIGHT ILLUMINATED DURING CRUISE, EICAS DISPLAYED. R & R NR 1 CARGO FIRE BOTTLE IAW AMM 26-33-02-40-131, TESTED IAW 26-23-00 ALL PASSED OK FOR SERVICE.SDR UIEA2013061000322Warning Light · false activationRIGHT ENGINE ANTI-ICE VALVE TRANSIT LIGHT INOPERATIVE. OPS CHECKED RIGHT ENGINE ANTI-ICE VALVE IAW AMM 30-21-00. OPS CHECKED NORMAL.SDR UIEA2013060700315Fuse · inoperativePAGE 7 OF 13, STEP 3 E. REVEALED FORWARD SEGMENT RT FROM SEAT LT TO SEAT 9 FLOOR MOUNTED AISLE PATH LIGHTTING SYS INOP. ALL OTHER EMERGENCY LIGHTING OPS CHECK NORMAL, IAW AMM 33-51-00/501. ACCOMPLISHED FIM 33-51 FAULT TREE 803, BLOCK 46. REPLACED POWER SUPPLSDR UIEA2013060400304Lamp · inoperativeR1 DOORWAY EMERGENCY LIGHT IS NOT WORKING. R & R LAMP IAW AMM 33-51-10 -962-077.SDR UIEA2013060400307Lamp · inoperativeOVERHEAD EMERGENCY LIGHTS INOPERATIVE, AND MISSING LENS BETWEEN A3-A4 LAVS. R & R LAMPS ON IAW AMM 33-51-11 AND INSTALLED NEW LENS BETWEEN A3-A4 LAVS IAW .SDR UIEA2013060400306Lamp · inoperativeEMERGENCY LIGHTS INOP AT SEATS 19JL AND 28JL. R & R LAMPS ON EMERGENCY LIGHTS IAW AMM 33-51-11-002-001.SDR UIEA2013060400305Lamp · inoperativeEMERGENCY LIGHT IS OUT AT 20D,23AC,31JL,. R & R LAMPS IAW AMM 33-51-10-962-077.SDR UIEA2013052800299Fan · warning messageEICAS MESSAGE "AFT EQ EXHAUST FAN 1, ACCOMPLISHED EQUIPMENT COOLING SYS ADJ/TEST IAW AMM 21-58-00/501. CHECKS GOOD MESSAGE CLEARED.SDR UIEA2013052600298Apu · inoperativeAPU NO START, IGNITION NOT ENERGIZED DURING START SEQUENCE, FUEL OK. TROUBLESHOT IAW FIM 49-11, FAULT TREE 958, FIG 107.SDR UIEA2013051500291Shutoff Valve · inoperativeRT PACK UNABLE TO CONTROL TEMP IN AUTO. R & R PACK FLOW CONTROL; SHUTOFF VALVE IAW AMM 21-51-01, OPS CHECK GOOD.SDR UIEA2013051400269Control Valve · inoperativeRT PACK UNABLE TO CONTROL TEMP IN AUTO MODE STANDBY.SDR UIEA2013050500255Cover · missingR4 DOOR EMERGENCY EXIT SIGN LENS COVER MISSING. REPLACED LENS COVER IAW AMM 33-51-01.SDR UIEA2013041600235Starter · leakingNR 1 ENGINE STARTER DRIVE PAD LEAKING. R & R NR 1 ENGINE STARTER DRIVE PAD NO LEAKS NOTED.SDR UIEA2013041500227Warning Message · false activationSTATUS MESSAGE "CABIN ALT AUTO 1", BIT CABIN ALT AUTO CONTROLLER NO FAULTS FOUND MESSAGE CLEARED IAW AMM 21-31-00.SDR UIEA2013031800141Battery · inoperativeFOUND L-1 DOOR AFT F/A EMERGENCY FLASHLIGHT NOT FLASHING. R & R L-1 DOOR AFT F/A EMERGENCY FLASHLIGHT BATTERY IAW AMM 25-64-00.SDR UIEA2013022200102Module · inoperativeON CLIMBOUT EICAS MESSAGE STAB TRIM APPEARED AND REMAINED FOR DURATION OF FLT. R & R STAB TRIM POSITION TRANSMITTER/MODULE IAW AMM 21-48-01/401. OPS CHECK, LEAK CHECK GOOD. THIS CLEARS MDDR 37897. PLACARD REMOVED.SDR UIEA2013021800090Transceiver · inoperativeRT WEATHER RADAR SYS INOPERATIVE. R & R RT WEATHER RADAR TRANCEIVER IAW AMM 34-43-01/401. OPS CHECKED GOOD. GROUND CHECKED GOOD.SDR UIEA2013021600089Cooling Fan · failedFWD EQUIPMENT COOLING EXHAUST FAN STATUS MESSAGE. R & R COOLING FAN IAW AMM 21-58-06/401. OPS CHECKED GOOD.SDR UIEA2013021300079Connector · unsecureAT 41000 FT AND START OF DESCENT RT PACK; RT PACK TEMP EICAS MESSAGE, RAN QRH AND PLACED PACK IN STBY MODE. FOUND CONNECTOR PLUG FOR THE COMPRESSOR OUTLET OVERHEAT TEMP SENSOR VERY LOOSE, RE-SECURED CONNECTOR PLUG IAW AMM 21-51-06, OPS CHECK NORMAL.SDR UIEA2013021400081Bulb · inoperativeDIM EXIT LIGHT BULB AT FWD OVERWING EXIT DOOR ON RT SIDE. BULB CHANGED.SDR UIEA2013021400082Skin · damagedGAUGE NOTED ON LT FUSELAGE SKIN AT STA 1809.5 S-17L EXCEEDS ALLOWED LIMITS IAW SRM 53-00-01, FIG 101. REPAIR ACCOMLISHED IAW SRM 53-80-01, REPAIR 3, DETAIL V AND SRI-2910010860.SDR UIEA2013021400083Floorbeam · corrodedCORROSION NOTED AT BS 347, RBL 45, FLOORBEAM EXCEEDS ALLOWED LIMITS IAW SRM 53-00-51. DAMAGE REPAIRED IAW SRM 53-00-51, REPAIR 1. REMOVED CORROSION SECTION OF BEAM CAP AND INSTALLED REPAIR CAP.SDR UIEA2013021400084Floorbeam · corrodedCORROSION NOTED ON BS 266.5 LBL 15 FLOORBEAM EXCEEDS ALLOWED LIMITS IAW SRM 53-00-51. DAMAGE REPAIRED IAW SRM 53-00-51, REPAIR 1. REMOVING CORROSION SECTION OF BEAM CAP AND INSTALLING REPAIR/ REPLACEMENT CAP.SDR UIEA2013021400085Floorbeam · corrodedCORROSION NOTED ON BS 325, LBL20, FLOORBEAM CAP EXCEEDS ALLOWED LIMITS IAW SRM 53-00-51. DAMAGE REPARIED IAW SRM 53-00-51. REPAIR 1. REMOVING CORROSION SECTION OF BEAM CAP AND INSTALLING REPAIR /REPLACEMENT CAP.SDR UIEA2012122900569Oil Filter · warning lightSTATUS MESSAGE " RT OIL FILTER" DISPLAYED. R & R RT ENGINE OIL FILTER ELEMENT IAW 79-21-04. PERFORMED ENGINE RUN, NO LEAKS NOTED, MESSAGE CLEARED.SDR UIEA2012122900571Oil System · lowAPU FAULT NO START AFTER LANDING. APU OIL LEVEL SHOWING 0.50, SERVICED APU OIL TO FULL, IAW AMM 12-13-04. OPS CHECKED GOOD. APU STARTED SUCCESSFULLY.SDR UIEA2012122300560Fire Loop · inoperativeLEFT ENGINE FIRE LOOP NR 1 INOPERATIVE. R & R LT ENG NR 1 UPPER AFT FIREWALL FIRE LOOP IAW AMM 26-11-02-401, OPS CHECKED GOOD.SDR UIEA2012112100533Transmitter · leakingEVIDENCE OF FUEL LEAK ON LT ENGINE DURING WALK AROUND. R & R LT ENGINE FUEL PRESSURE TRANSMITTER, AMM 73-33-01, LEAK CHECKED NORMAL.SDR UIEA2012110300511Oil System · lowAPU RELIABILITY COLD START ACCOMPLISHED DURING FLT FL 400, FAILED ON ATTEMPT THREE, EGT 850 DEG, RPM 30 PERCENT, OIL QTY .25. SERVICED APU OIL TO FULL, CLEANED AND RESATED APU OIL QTY. TRANSMITTER CONNECTOR, APU STARTS AND OPERATES NORMALLY, QTY READS FULL, SDR UIEA2012101100463Oil System · lowAPU RELIABILITY COLD SOAK START, UNSUCESSFUL START ATTEMPTS. APU OIL QTY FOUND BELOW FULL (.25), SERVICED AS REQUIRED. SYSTEM STARTS/OPERATES GOOD IAW AMM 49-11-00/12-13-04.
Back to N641GT