N641GT

Service difficulty reports · 1,011

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N641GT' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR UIEA2012091700422Duct · damagedRT ACFT PACK HAS A DUCT LEAK. FOUND DUCT SEAL AT SLIP COUPLING BAD, DUCT DAMAGED, INSTALLED SERVICABLE LOANER DUCT. OPS & LEAK CHECK GOOD, IAW AMM 21-51-03; 21-51-00.Sep 15, 2012 · N641GT · Boeing 76738E · Air Distribution SystemSDR UIEA2012091300420Pump · leakingRT ENGINE EDP IS LEAKING. R & R RT ENGINE DRIVEN PUMP IAW AMM 29-11-05. OPS & LEAK CHECKED OK.Sep 12, 2012 · N641GT · Boeing 76738E · Hydraulic Pump (Electric/Engine), MainSDR UIEA2012091300419Skin · delaminatedRT REAR NOSE DOOR SHOWS SIGNS OF DELAMINATION. REPAIRED IAW EO 6752A007 PART 1.Sep 12, 2012 · N641GT · Boeing 76738E · Landing Gear DoorsSDR UIEA2012091100412Indicator · inoperativeRT WING FUEL QUANITY INDICATOR INOPERATIVE.Sep 11, 2012 · N641GT · Boeing 76738E · Fuel Quantity IndicatorSDR UIEA2012091000394Warning Message · illuminatedSTATUS MESSAGE FOR LT ENGINE FIRE LP1.Sep 9, 2012 · N641GT · Boeing 76738E · Fire DetectionSDR UIEA2012091000393Fuel Filter · leakingSTATUS MESSAGE FOR LT ENG FUEL FILTER. R & R LT ENG FUEL FILTER ELEMENT WITH NEW UNIT IAW AMM 73-11-02. LEAK, OPS AND GROUND CHECKED GOOD.Sep 9, 2012 · N641GT · Boeing 76738E · Fuel Controlling SystemSDR UIEA2012090300378Warning Message · illuminatedSTATUS MESSAGE "LT ENGINE FIRE LOOP 1". OPENSep 3, 2012 · N641GT · Boeing 76738E · Fire DetectionSDR UIEA2012090100371Terminal · looseEICAS MESSAGE FOR LT ENGINE FIRE LOOP ONE, DISPLAYED. FOUND LOWER AFT ENGINE FIRE DETECTOR TERMINAL LOOSE. CLEANED & AMP; INSTALLED IAW AMM 26-11-02/406. OPS CKS GOOD.Aug 31, 2012 · N641GT · Boeing 76738E · Fire Protection System WiringSDR UIEA2012081300355Shutoff Valve · failedFOUND LEFT ENGINE PRSOV FAILING TO FULLY CLOSE DURING ENGINE RUNS. R & R NR 1 ENGINE PRSOV IAW AMM 36-11-09/212. OPS CHECKED GOOD.Aug 12, 2012 · N641GT · Boeing 76738E · Pneumatic Distribution SystemSDR UIEA2012081300354Controller · inoperativeRT ENGINE BLEED OFF EICAS MESSAGE IN FLIGHT. SWAPPED PRV CONTROLLERS BETWEEN NR1 AND NR2 ENGINES. VERIFIED BAD PRV CONTROLLER. CURRENTLY INSTALLED ON NR1 ENGINE. R & R NR 1 ENG PRV CONTROLLER IAW AMM 36-11-19/401. OPS CHECKED GOOD.Aug 12, 2012 · N641GT · Boeing 76738E · Pneumatic Distribution SystemSDR UIEA2012081100351Warning Light · illuminatedRT ENGINE BLEED OFF EICAS MESSAGE IN FLIGHT.Aug 11, 2012 · N641GT · Boeing 76738E · Engine Bleed Air SystemSDR UIEA2012081000350Warning Light · illuminatedRT ENG BLEED OFF EICAS MESSAGE.Aug 10, 2012 · N641GT · Boeing 76738E · Engine Bleed Air SystemSDR UIEA2012073100337Shutoff Valve · inoperativeRIGHT ENGINE BLEED PRESSURE INOPERATIVE WITH ENGINE PRESSURE. REMOVED RIGHT ENGINE PRSOV, OPS CHECKED NORMAL.Jul 31, 2012 · N641GT · Boeing 76738E · Engine Bleed Air SystemSDR UIEA2012072600332Light · inoperativeR4 DOOR EXTERIOR EMERGENCY LIGHT INOPERATIVE. R & R4 DOOR EMERGENCY LIGHT IAW AMM 33-51-16.Jul 26, 2012 · N641GT · Boeing 76738E · Emergency LightingSDR UIEA2012072500331Slide · separatedON WALK AROUND INSPECTION, MX FOUND L1 SLIDE PARTIALLY SEPARATED FROM SLIDE COVER (R & R L1 DOOR SLIDE. PLACARD REMOVED. REF MM 25-66-01)Jul 25, 2012 · N641GT · Boeing 76738E · Escape SlideSDR UIEA2012072400330Smoke Detector · no testSMOKE LIGHT FAILED TO ILLUMINATE DURING EQUIPMENT COOLING TEST. REPLACED SMOKE DETECTOR LAW AMM 21-56-17.Jul 20, 2012 · N641GT · Boeing 76738E · Smoke DetectionSDR UIEA2012071100315Circuit Breaker · failedLEFT AC BUSS INTERMITTENT ON ENGINE SHUTDOWN. FOUND LT GENERATOR CONTROL CIRCUIT BREAKER T-1 CONTACT OPEN DURING FAULT. R & R LT GENERATOR CONTROL CIRCUIT BREAKER IAW AMM 24-22-03, SYS OPS CHECKED GOOD.Jul 11, 2012 · N641GT · Boeing 76738E · AC Power Distribution SystemSDR UIEA2012062800292Coupling · backed outLEADING EDGE SLAT ASYM EICAS MESSAGE. FOUND TORQUE TUBE COUPLING BACKED OFF AT NR 8 SLAT ROTARY ACTUATOR. RESECURED COUPLING IAW AMM 27-81-24/417, STOP CLEARANCES CHECKED GOOD.Jun 28, 2012 · N641GT · Boeing 76738E · Leading Edge Slat Control SystemSDR UIEA2012062700286Buss Tie · failedLEFT BUSS TIE AND LEFT GENERATOR FIELD TRIP OFF ON ENGINE SHUTDOWN. REPLACED RT BTB WITH SERVICABLE UNIT IAW AMM 23-22-03. OPS CHECKED GOOD. ENGINE GROUND TESTED OK IAW AMM 71-00-00/201.Jun 25, 2012 · N641GT · Boeing 76738E · Electrical Power System WiringSDR UIEA2012062700285Seal · leakingLEFT PACK DUCT LEAK ILLUMINATED ON GROUND WITH PACK ON. FOUND AIR LEAK SECONDARY HEAT EXCHANGER DUCT COUPLING. REPLACED SEAL WITH NEW UNIT IAW AMM 21-51-02 LEAK AND OPS CHECKED GOOD.Jun 24, 2012 · N641GT · Boeing 76738E · Air Distribution SystemSDR UIEA2012062400278Battery · inoperativeAPU FAULT ON GROUND - IAW MCC. REPLACED APU BATTERY WITH REPAIRED UNIT IAW AMM 34-31-04. OPS /GND CHECK - GOOD. OK FOR CONTINUE SERVICE.Jun 24, 2012 · N641GT · Boeing 76738E · APU Start/Ignition SystemSDR UIEA2012062300277Indicator · intermittentLEFT WING FUEL PANEL, RT MAIN FUEL QTY INDICATOR , DIGITS NOT LEGIBLE AND INTERMITTENT. REPLACED LT WING, RT MAIN FUEL QTY INDICATOR WITH REPAIRED UNIT IAW AMM 28-21-13.Jun 23, 2012 · N641GT · Boeing 76738E · Fuel Quantity IndicatorSDR UIEA2012062300276Starter · malfunctionedAPU DIDN'T START ON TAXI-IN. THREE ATTEMPTS. PERFORMED OPS CHECK OF APU START SYS. IAW FIM 49-11-00. APU STARTEDJun 23, 2012 · N641GT · Boeing 76738E · APU Start/Ignition SystemSDR UIEA2012062200275Apu · faultedAPU FAULT EICAS AFTER LANDING THREE ATTEMPTS. PERFORMED OPS CHECK OF APU IAW FIM 49-11-00, FIG 106A. NO FAULTS NOTED - GROUND CHECK OK.Jun 22, 2012 · N641GT · Boeing 76738E · APU Start/Ignition SystemSDR UIEA2012062100273Processor · faultedDURING REFUEL, NR 1 MAIN FUEL QUANTITY INDICATION BLANKED OUT. R & R FUEL PROCESSOR GROUND OP'S CHECKED NORMAL IAW MM 28-41-0.Jun 21, 2012 · N641GT · Boeing 76738E · Fuel Quantity IndicatorSDR UIEA2012061800270Cover · missingISLE PATH LIGHT AT ROW 30R MISSING SEAT TRACK COVER LIGHT. LIGHT OPS OK.Jun 18, 2012 · N641GT · Boeing 76738E · Emergency LightingSDR UIEA2012061600267Fuel Filter · failedSTATUS MESSAGE "RT ENG FUEL FILTER". R & R RT ENGINE FUEL FILTER IAW AMM 73-11-02. LEAK CHECKED GOOD.Jun 16, 2012 · N641GT · Boeing 76738E · Engine Fuel DistributionSDR UIEA2012060800260Unknown · unknownLEFT AC BUSS FAILED AFTER SHUTDOWN. PERFORMED BITE TEST OF BPCU, NO FAULTS LISTED. PEFORMED ENGINE RUN FOR BUS PICK UP VERIFICATION, SYS OPS CHECKED GOOD. FIM 24-20-00/104.Jun 8, 2012 · N641GT · Boeing 76738E · Electrical Power SystemSDR UIEA2012060100256Starter · failedAPU WILL NOT START. REMOVED & REPLACED APU STARTER PER AMM 49-41-01, SYSTEM OPS CHECKED GOOD.Jun 1, 2012 · N641GT · Boeing 76738E · APU Start/Ignition SystemSDR UIEA2012051800244Warning Message · false activationEICAS STATUS MESSAGE " CABIN ALT AUTO 2" DISPLAYED. PERFORMED FAULT ISOLATION IAW AMM 21-31-00/101, FIG 110, STEP 23 REF TO FIG 103 THRU STEP 5, SYS IS OK.May 18, 2012 · N641GT · Boeing 747300 · Cabin Pressure Control SystemSDR UIEA2012051800243Wire · damagedFWR CARGO DOOR CAUTION LIGHT WHILE LEVELING OFF AT 34,000. QRH PROCEDURE COMPLETED AND AT APPROX 16,000 CAUTION LIGHT WENT OUT. PRESSURIZATION GAUGES INDICATED NORMAL. VISUALLY INSPECTED DOOR ON LANDING, ALL INDICATION CLOSED AND LATCHED. INSPECTED DOOR AMay 18, 2012 · N641GT · Boeing 76738E · Door System WiringSDR UIEA2012051300215Charger · inoperativeEMERGENCY EXIT FLOOR LIGHT BETWEEN ROW 10-29 RT INOPERATIVE. REPLACED BATTERY CHARGER ASSY IAW AMM 33-51-10, OPS CHECKED GOOD.May 13, 2012 · N641GT · Boeing 76738E · Emergency LightingSDR UIEA2012051300214Control Valve · failedLEFT PACK TEMPERATURE EICAS MESSAGE. R & R PACK TEMPERATURE CONTROL VALVE IAW AMM 21-51-12. OPS CHECKED NORMAL.May 13, 2012 · N641GT · Boeing 76738E · Cabin Temperature Control SystemSDR UIEA2012050900200Warning Message · illuminatedEICAS "LT PACK TEMP". OPERATES NORMAL IN STANDBY MODE.May 9, 2012 · N641GT · Boeing 76738E · Cabin Cooling SystemSDR UIEA2012050900199Warning Message · illuminatedEICAS MESSAGE "LT PACK TEMP", COMPLIED WITH QRH AND SET AUTO SWITCH TO "N" MESSAGE WENT AWAY. PERFORMED FIM 21-51-00, FIG 103 AND TABLE B TEMP CONT VALVE STEP 1, SYS CHECKED NORMAL.May 9, 2012 · N641GT · Boeing 76738E · Cabin Cooling SystemSDR UIEA2012042600167Pitot Head · failedAFTER ENGINE START, RT AUX PITOT EICAS MESSAGE DISPLAYED, RETURN TO BLOCKS. R & R RT LOWER PITOT PROBE, OPS AND LEAK CHECKED OK. OK FOR SERVICE IAW MM 34-11-01.Apr 26, 2012 · N641GT · Boeing 76738E · Pitot/Static SystemSDR UIEA2012042600168Gcu · failedLEFT GCU FAILED BPCU BITE TEST. R & R LT GCU, OPS CHECKED OK, OK FOR SERVICE IAW MM 24-11-00.Apr 26, 2012 · N641GT · Boeing 76738E · AC Generation SystemSDR UIEA2012042500161Indicator · no testSTANDBY ENGINE INDICATOR FAILED TEST. REPLACED INDICATOR, BITE TESTED GOOD IAW AMM 77-41-01.Apr 25, 2012 · N641GT · Boeing 76738E · Engine Indicating SystemSDR UIEA2012042500162Wire Harness · damagedFIRE LOOP ELECTRICAL HARNESS DAMAGED. NR 1 ENG AT 6 O'CLOCK POSITION NEAR DRAIN TUBE. REPAIRED FIRE LOOP WIRE HARNESS IAW WDM 20-10-13.Apr 25, 2012 · N641GT · Boeing 76738E · Fire Protection System WiringSDR UIEA2012042500163Seal · brokenNR 5 FUEL NOZZLE SEAL BROKEN. NR 2 ENG OTBD FUEL RAIL NR 5 NOZZLE. R & R NR 5 FUEL NOZZLE SEAL AT NR2 ENG O/B FUEL RAIL IAW BAMM 767 73-11-05 THRU STEP 5D(5). PERFORMED OPS AND LEAK CK IAW AMM 73-11-05, CHECKS GOOD.Apr 25, 2012 · N641GT · Boeing 76738E · Fuel Injector NozzleSDR UIEA2012042500164Rod End · wornSTARTER DUCT LINK ROD END BEARINGS WORN NR 2 ENGINE SIDE 10:00. REPLACED ROD ENDS IAW AMM 70-00-00. REINSTALLED STARTER DUCT LINK IAW AMM 80-11-05.Apr 25, 2012 · N641GT · Boeing 76738E · Engine StarterSDR UIEA2012042500165Gasket · damagedGASKET DAMAGED ON FLOW SENSOR MODULE ON APU. REPLACED GASKET ON FLOW SENSER MODULE/ASSY IAW AMM 49-53-08.Apr 25, 2012 · N641GT · Boeing 76738E · APU Bleed Air SystemSDR UIEA2012042500166Control Valve · inoperativeRT PACK TEMPERATURE CONTROL INOPERATIVE IN AUTO. R & R RT PACK TEMPERATURE CONTROL VALVE IAW AMM 21-51-12.Apr 25, 2012 · N641GT · Boeing 76738E · Cabin Cooling SystemSDR UIEA2012042100160Circuit Breaker · trippedON LANDING, RT AUX PITOT EICAS MESSAGE APPEARED. FOUND CIRCUIT BREAKER TRIPPED, RESET IAW SWPM 20-60-05. PERFORMED SYS TEST IAW AMM 30-31-00. OPS CHECKED GOOD.Apr 21, 2012 · N641GT · Boeing 76738E · Pitot/Static SystemSDR UIEA2012042100159Warning System · false activationAT ENGINE SHUTDOWN, LT A/C BUSS FAILURE, LT GENERATOR FIELD TRIPPED ALSO. RESET GENERATOR FIELD LIGHT IAW AMM 24-11-00, RAN ENGS IAW AMM 71-00-00, CYCLED POWER BETWEEN ALL BUSSES. OPS GOOD, NO FURTHER FAULTS NOTED.Apr 21, 2012 · N641GT · Boeing 76738E · AC Generator-AlternatorSDR UIEA2012041900132A/C Pack · malfunctionedRIGHT PACK TEMP EICAS MESSAGE. IN STANDBY MODE, OPERATED NORMALLY. AFTER QRH PROCEDURE, MESSAGE CLEARED. OPENApr 19, 2012 · N641GT · Boeing 76738E · Cabin Cooling SystemSDR UIEA2012041800131Warning Message · false activationRIGHT PACK TEMP EICAS MESSAGE. RT PACK SELECTOR POSITIONED TO "N" IAW QRH PROCEDURES, MESSAGE CLEARED. PERFORMED RT PACK TEMP CONTROLLER BIT IAW FIM 21-51-00. NO FAULTS NOTED & RELEASED OK FOR SERVICE.Apr 18, 2012 · N641GT · Boeing 76738E · Cabin Cooling SystemSDR UIEA2012041400122Indicator · inaccurateOUTFLOW VALVE INDICATOR INDICATES .5 OPEN IN CRUISE. PERFORMED BITE ONE BOTH CPC'S, NO FAULT FOUND IAW AMM 21-31-00, SYS. CHECKED NORMAL IN BOTH AUTO AND MANUAL MODES. OK FOR SERVICE.Apr 14, 2012 · N641GT · Boeing 76738E · Pressure Regulator/Outflow ValveSDR UIEA2012040600117Warning Message · false activationCABIN ALTIMETER AUTO 1 STATUS MESSAGE, BITE CHECK COMPLIED WITH IAW AMM 21-31-00, NO FAULTS FOUND.Apr 6, 2012 · N641GT · Boeing 76738E · Cabin Pressure Control SystemSDR UIEA2012032100099Warning Message · illuminatedCABIN ALTITUDE AUTO 1. PERFORMED CABIN CABIN PRESSURE CONTROLLER BITE TEST IAW FIM 21-31-00/105. NO FAULTS NOTED MESSAGE CLEARED.Mar 20, 2012 · N641GT · Boeing 76738E · Cabin Pressure Control System
Back to N641GT