N645AE
Service difficulty reports · 216
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N645AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N645AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2021112900590None · noneE888043 - SERVICE DOOR CENTER SILL CORRODED AROUND AFT NUT PLATE HOLE ... PREPPED, FABICATED AND INSTALLED FABRICATED INTERNAL DOUBLER FOR SERVICE DOOR CENTER SILL REPAIR AROUND AFT NUT-PLATE HOLE AND APPLIED HYSOL TO AREA IAW EMB 145 SRM 53-21-02RE, ITEM 2, FSDR HNAA2021112900589None · noneE888042 - SERVICE DOOR CENTER SILL CORRODED AROUND FWD NUT PLATE HOLE .... PREPPED, FABRICATED AND INSTALLED FABRICATED INTERNAL DOUBLER FOR SERVICE DOOR CENTER SILL REPAIR AROUND FWD NUT-PLATE HOLE AND APPLIED HYSOL TO AREA IAW EMB 145 SRM 53-21-02RE, ITEM 2,SDR HNAA2021112900587None · noneE888037 - LH LOWER #1 SEAT TRACK CORRODED .... INSTALLED LH #1 LOWER SEAT TRACK IAW EMB 145 AMM 53-01-06SDR HNAA2021112900586None · noneE888036 - LH UPPER #1 SEAT TRACK CORRODED .... REMOVED AND REPLACED LH #1 UPPER SEAT TRACK IAW EMB 145 AMM 53-01-06.SDR HNAA2021112900584None · noneE888031 - OUTBD BRACKET AT FR 23 FLOORBOARD STEP DOWN CORRODED .... PERFORMED BLEND OUT OF DAMAGE ON THE OUTBD BRACKET AT FR23 FLOOR BOARD STEP DOWN. UPON FURTHER INVESTIGATION FOUND DAMAGE TO BE OUT OF LIMITS, RAR OUTBD BRACKET AT FR 23 FLOORBOARD STEP DOWN ISDR HNAA2021112900583None · noneE888030 - AFT SERVICE DOOR SILL CORRODED AROUND AT UPPER JOGGLE .... RAR SERVICE DOOR AFT SILL IAW EMB-145 SRM 51-40-02.SDR HNAA2021112900582None · noneCORRECTION TO DUPLICATE UNIQUE CONTROL NUMBER - E887876 - CARGO DOOR CUT-OUT FR 65 SHEAR CLIP CORRODED .... REPAIRED CARGO DOOR CUT OUT FR 65 SHEAR CLIP IAW EMB 145 SRM 53-31-04-RE FIGURE 212 AND EO1-53-21-0317SDR HNAA2021112900573None · noneE887759 - CARGO DOOR INTERNAL WEBBING HAS NUMEROUS NICKS ... ACCOMPLISHED REPAIR OF 3 DAMAGED AREAS ON CARGO DOOR INNER SKIN AT FWD FRAME /HB4, VB3/HB4, AND VB2/HB3 IAW EMB 145 SRM 52-30-01 ITEM 12 AND FIGURE 213 AND EO1-52-21-0316SDR HNAA2021112900570None · noneE887314 - LAV BUCKET EXTERNAL SURFACE CORRODED AROUND WASTE DRAIN VALVE MARKED ... REMOVED, PREPPED AND INSTALLED SERVICEABLE LAV ( BUCKET) CUP IAW EMB 145 SRM 51-40-02SDR HNAA2021112900572None · noneE887742 - CARGO DOOR UPPER FRAME PROFILE CORRODED AT NUTPLATE HOLE ... REMOVED AND INSTALLED NEW CARGO DOOR UPPER FRAME PROFILE IAW EMB 145 SRM 51-40-02, 51-40-09SDR HNAA2021112900581None · noneE887876 - CARGO DOOR CUT-OUT FR 65 SHEAR CLIP CORRODED .... REPAIRED CARGO DOOR CUT OUT FR 65 SHEAR CLIP IAW EMB 145 SRM 53-31-04-RE FIGURE 212 AND EO1-53-21-0317SDR HNAA2021112900580None · noneE887870 - SHEAR CLIP AT FR 65 BETWEEN STRGS 21R-20R CORRODED ... REMOVED AND REPLACED SHEAR CLIP AT FR 65 BETWEEN STRGS 21R-20R IAW EMB 145 SRM 51-40-02.SDR HNAA2021112900577None · noneE887864 - CARGO DOOR LWR CUT-OUT FLOOR SILL CORRODED ... REMOVED AND REPLACED CARGO DOOR CUT- OUT LOWER FLOOR SILL IAW EMB 145 SRM 51-40-02.SDR HNAA2021112900576None · noneE887863 - RH #4 CARGO FLOOR SILL CORRODED .... RAR RH #4 CARGO FLOOR SILL IAW EMB145 SRM 51-40-02SDR HNAA2021112900575None · noneE887860 - RH #1 CARGO FLOOR SILL CORRODED ... REMOVED AND INSTALLED NEW RH #1 CARGO FLOOR SILL IAW EMB 145 SRM 51-40-02.SDR HNAA2021112900574None · noneE887858 - LH #2 CARGO FLOOR SILL CORRODED .... UPON FURTHER INVESTIGATION FOUND DAMAGE ON THE LH #2 CARGO FLOOR SILL TO BE OUT OF LIMITS IAW EMB 145 SRM 51-31-10-AD. REMOVED AND REPLACED LH #2 CARGO FLOOR SILL IAW EMB 145 SRM 51-40-02.SDR HNAA2021112900578None · noneE887865 - FR 66 CRACKED AT STRG 16R .... REMOVED, FABRICATED AND INSTALLED FABRICATED FR-66 SPLICE "U" SHAPE DOUBLER REPAIR AT STRG 16R IAW EMB 145 SRM 53-00-04-RE FIGURE 201 AND EO1-53-21-0318SDR HNAA2021112900579None · noneE887868 - FR 69 DAMAGED FROM CHAFING BETWEEN STRGS 18L-19L .... PREPPRED, FABRICATED AND INSTALLED SERVICEABLE REPAIR INTERNAL DOUBLER AND FILLER FOR FR 69 BETWEEN STRGS 18L-19L IAW ETD2021-145-037110 AND EO1-53-21-0319SDR HNAA2021011100008Unknown · odorPACK 2 OVERHEAT WITH STRONG BURNING SMELL WHEN THRUST LEVERS AT HIGH SETTING. C/W FIM TASK 21-51-00-810-804-A BLOCK 2 RESULT IN NO PACK 2 OVERHEAT EICAS MESSAGE. NO RESULT BLOCK II TRANSITORY CONDITION OF AIR CONDITIONING SYSTEM. END TROUBLE-SHOOTING. FOUNSDR HNAA2020021700065Computer · malfunctionedPDIS 645 31-50 2130021 14FEB20 CLT CLOSE
AFTER TAKEOFF, TAKEOFF CONFIG TRIM AURAL WARNING, WA
RNING STOPPED BY ITSELF. NO EICAS MESSAGES. TRIM IND
ICATIONS WITHIN RANGE.
FACT 14FEB20 16:39 CLT
R&R AURAL WARNING COSDR HNAA2019120600375Knob · detachedSTAND-BY ALTIMETER KNOB FELL OFF....FIX: RESECURED KNOB.OK FOR SERVICE.OPS CHECK GOODSDR HNAA2019090900266Acm · seizedPDIS 645 21-01 2075172 08SEP19 MDT CLOSE SMOKE IN COCKPIT AT FL 210 CREW RAN QRH. NO EICAS MESSAGES PRESENT. FACT 08SEP19 11:33 MDT FOUND #1 ACM SEIZED R&R'D #1 ACM REF AMM 21-51-03 OPS CK GOOD AT THIS TIME.SDR HNAA2019090700253Fuse · blownPAX DOOR EMERGENCY LIGHT INOP. FIX: REMOVED #1 EMERGENCY LIGHTING SYS BATTERY. FOUND BAD FUSE ON BATTERY PACK BASE. R&RD FUSE. REINSTALLED BATTERY.SDR HNAA2019072600200O-Ring · damagedBLEED 1 LEAK WARNING AFTER TAKE-OFF C/W QRH MESSAGE EXTENDED RETURNED TO PHL. FIX: MAINT INSPECTED AND FOUND DAMAGED ORING IN BAG BAY BLEED VALVE AT JOINT 19 IN REF TO AMM 36-11-10. R&RD BLEED ORING IN REF TO AMM 36-11-10. OPS CHECK GOOD AND LEAK CHECK OK FOR SDR HNAA2019072200199O-Ring · damagedBLEED 1 LEAK EICAS MESSAGE ON APPROACH. FIX: FOUND LEAKING 0-RING ON BAG BAY BLEED DUCT AND AFT CABIN BLEED DUCT. R&RD O-RINGS IAW AMM 36-11-10-000-801-A/400-801-A. OPS CHECK AND LEAK CHECK GOOD. OK FOR SERVICE.SDR HNAA2019062800186Unknown · odorAT 24,000 FT SMOKE ENTERED COCKPIT WITH BURNT PLASTIC SMELL AND HAZE IN CABIN. THERE WAS ALSO LOSS OF AIRFLOW IN PACK #1... FIX: INSPECTED PACK 1 FOR DAMAGE, NONE FOUNDNO #1 PACK HAD LOSS OF AIR FLOW). R & R THE LT ACM.SDR HNAA2019062800185Acm · inoperativeNR 1 PACK HAD LOSS OF AIRFLOW. R & R ACM IAW AMM 21-51-03, OPS CHECK GOOD. FOUND DURING RUNS AT TRI.SDR HNAA2019052900151Switch · faulty645 05-50 1881141 25MAY19 CLT CLOSE ELECTRICAL SMELL IN FLT DECK DURING TAXI OUT. 29593 00 VAG FACT 25MAY19 15:50 CLT R\R #2 PACK OVERTEMP SWITCH RAN A/C WITH BOTH PACK OPS CHECK GOOD OK FOR SERVICE.SDR HNAA2019031600073Unknown · malfunctionedPDIS 645 21-30 1907392 14MAR19 ROA CLOSE AT FLT LEVEL 250 CABIN GOT WARM IN BACK, CAPT LOWERED TEMP AND WENT INTO MANUAL MODE AT WHICH POINT PACK 1 CLOSED. CABIN ALTITUDE SHOT FROM 4000 TO 7000 FT IN SECONDS. STARTED DECENDING PACK 1 CAME ON AND DIVERTED TO ROSDR SIMA20190104011Skin · corrodedPROTRUSION AND CORROSION IN SKIN AND RIVETS PULLED THROUGH AT FRAME 67 BETWEEN STGRS 20L AND 21R. PROTRUSION AND CORROSION IN SKIN AND RIVETS PULLED THROUGH AT FRAME 67 BETWEEN STGRS 20L AND 21R REPAIRED IAW ERS-EM-53MR-3603.SDR SIMA20190104010Beam · gougedRT PASSENGER CABIN ESCAPE HATCH BEAM 2 IS GOUGED 2 EACH. RT PASSENGER CABIN ESCAPE HATCH BEAM (INTERNAL SKIN) GOUGES REPAIRED IAW ERS-EM-52MR-947.SDR SIMA20190104009Wire · brokenLT EMERGENCY PROXIMITY LIGHT STRIP NR 4 HAS A BROKEN WIRES. R&R NR 4 LT FLOOR PROXIMITY LIGHT IAW AMM 33-50-12-04.SDR SIMA20190104008Fitting · damagedALL LT EMERGENCY LIGHT FLOOR EXTRUSIONS DAMAGED (EXCLUDING RAMP). R&R ALL LT EMERGENCY LIGHT FLOOR EXTRUSIONS (EXCLUDING RAMP) IAW AMM 33-50-12-04.SDR SIMA20190104007Wire · brokenEMERGENCY LIGHT STRIP AT 251BF HAS BROKEN WIRE ON THE AIRCRAFT SIDE. REPAIRED LIGHT STRIP WIRE AT 251BF IAW SWPM 20-50-00.SDR SIMA20190104006Floor Support · corrodedCABIN CENTER OMEGA BEAM AT FR38 IS CORRODED.SDR SIMA20190104005Rib · crackedRT WING RIB 21 IS CRACKED INSIDE PANEL 651CB. PERFORMED REPAIR ON RT RIB 21 AS REQUIRED IAW SRM 57-20-07 STEP 4.SDR SIMA20190104012Floor Support · corrodedCABIN LT OMEGA BEAM AT FR.38 IS CORRODED. REPAIRED CABIN LT OMEGA BEAM AT FR 38 IAW SRM 53-00-10RE ITEM 3 FIGURE 202 SHEET 2.SDR SIMA20190104013Wire · brokenLT FORWARD EMERGENCY PROXIMITY LIGHT STRIP NR 3 HAS A BROKEN WIRE. R&R NR 3 LT FLOOR PROXIMITY LIGHT IAW AMM 33-50-12-04.SDR SIMA20190104014Skin · crackedCARGO DOOR EXTERIOR SKIN IS CRACKED AT HANDLE CUTOUT. COMPLIED WITH ERS EM-53MR-946 CARGO DOOR SKIN - PERMANENT REPAIR.SDR SIMA20190104004Fitting · crackedLT PYLON INTERIOR FUSELAGE TO RIB "5" SHEAR CLIP IS CRACKED. REMOVED AND INSTALLED SERVICEABLE SHEAR CLIP INSIDE PYLON IAW SRM 51-40-02.SDR SIMA20181231001Warning System · false activationPACK 1 & 2 OVERLOAD CONTINUOUS MSG-C/A-OPERATED BOTH PACKS ON GROUND IN VARIOUS TEMP SETTINGS FOR 20 MINS. COULD NOT DUPLICATE MSG. OPS CHECK IAW AMM TASK 21-20-00 SUCCESSFUL.SDR SIMA201812264003Lamp · inoperativeROW 12 CEILING EMERGENCY LIGHT INOP-C/A-RAR ROW 12 CEILING EMERGENCY LAMP IAW EMB AMM TASK# 33-50-08-000-801-A AND 33-50-08-400-801-A. OPC GOOD. ENDSDR SIMA2018081311001Lamp · inoperativeDURING A PS-2 CHECK, FOUND THE COCKPIT EMERGENCY LIGHT TO BE INOPERATIVE. REMOVED AND REPLACED THE LAMPS IAW AMM 33-50-05-000-801-A AMM 33-50-05-400-801-A. OPS CHECKED GOOD. NO FURTHUR DEFECTS NOTED.SDR SIMA2018072523004Sensor · failedABORTED TAKEOFF AT 60 KTS E2 NO DISP. C/W FIM 75-41-00-810-804-A01 & FIM 75-41-00-810-801-A01. REMOVED AND REPLACED ENGINE T2.5 SENSOR IAW MM 75-41-10.SDR SIMA20180719006Unknown · odorPOSSIBLE LIGHTING STRIKE WHILE IN CLOUDS FLIGHT LEVEL 220 ELECTRICAL BURNING SMELL LIKE FOR ABOUT 5-10 MIN EXIT OUT OF CLOUDS SMELL DISSIPATED. PERFORMED GVI OF AIRCRAFT IAW SRM 51-10-02. NO EVIDENCE OF LIGHTING STRIKE FOUND. CREW PERFORMED ENGINE RUN. NO SMELSDR SIMA20180312002Lamp · inoperativeGALLEY DOOR EMERGENCY LIGHT INOPERATIVE. R & R THE LAMP IAW AMM 33-50-10-000-801-A, AND 33-50-10-400-801-A. NO FURTHER DISCREPANCIES FOUND.SDR SIMA20180130003Wire · brokenSERVICE DOOR EMERGENCY LT INOP. REMOVED AND REPLACED SERVICE DOOR EMERGENCY LAMP IAW AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. NO FIX. PERFORMED GVI AND FOUND BROKEN WIRE. RESPLICED WIRE IN REFERENCE WITH SWPM-2430-20-21-00. OPC GOOD. NO FURTHER DISCREPANSDR SIMA20170608002Lamp · inoperativeRIGHT EXTERIOR AFT EMERGENCY LIGHT INOPERATIVE. R & R THE LAMP IAW AMM 33-50-10. OPS TESTED GOOD IAW AMM 33-50-00.SDR SIMA20170607001Roller · lack of lubeCABIN DOOR IS DIFFICULT TO OPEN AND CLOSE. LUBED MAIN CABIN DOOR FRAME ROLLERS IAW AMM 53-21-02. OK FOR SERVICE.SDR SIMA20170519002Connector · damagedCONNECTOR ON LIGHT STRIP 8 BROKEN. REMOVED AND REPLACED THE CONNECTOR IAW SWPM 20-00-03. OPS CHECKED GOOD.
Back to N645AE