N645GT
Service difficulty reports · 716
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N645GT' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N645GT' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2020082101839Sensor · malfunctionedRT PACK PRIMARY HEAT EXCHANGE TEMP SENSOR DATA MISSING REMOVED AND REPLACED TEMP SENSOR IAW B767 AMM 21-52-08, OPS CHECKED GOODSDR UIEA2020081731766Controller · malfunctionedR PACK TEMP REMOVED AND REPLACED RT TEMP SENSOR TS 199 AND STBY SENSOR IAW 21-51-08 (OFF PART: PN624014-2, NSN). NO HELP. TRANSFERRED TO MEL 21-53-03-01, AUTO MODE, REMOVED AND REPLACED RH PACK TCV IAW AMM 21-51-12 AND REPLACED RT PACK CONTROLLER IAW AMM 21-5SDR UIEA2020080401689Warning Message · false activationRT PACK TEMP MESSAGE. PERFORMED A PACK BITE IAW AMM 21-51-844. CLEARED MESSAGE. OPS CHECKED OK.SDR UIEA2020072701620Unknown · noiseLOUD NOISE IN AFT GALLEY WITH APU AIR SELECTED ON(<P>PERFORMED DVI AND APU BLEED LEAK TEST IAW AMM 36-11-00, NO DEFECTS. REMOVED, INSPECTED, REINSTALLED APU BLEED CHECK VALVE IAW AMM 36-11-11, NO DEFECTS. INSPECTED APU AIR SUPPLY VALVE AND OPS TEST IAW AMM 36-SDR UIEA2020071801571Valve · illuminatedEICAS FOR FWD CABIN TEMP FWD CABIN CONTROL INOPERATIVE. R & R TRIM AIR MODULATING VALVE IAW AMM 21-61-07. OPS CHECKED GOOD.SDR UIEA2020071501557Oil System · lowAPU AUTO SHUT DOWN IN FLT. "LOW" OIL QTY INDICATED ON EICAS STATUS. SERVICED APU 1.0 QT. PERFORMED EXTERNAL LEAK CHECK. NO LEAKS NOTED. OPS CHECKED GOOD IAW 49-41-81.SDR UIEA2020070801505Starter · malfunctionedRIGHT ENGINE STARTER CAUTION MESSAGES ON ENG START. NO N2 RISE NOTED. REMOVED AND REPLACED RT ENGINE STARTER IAW AMM 80-11-1 OPS CHECK OK.SDR UIEA2020070101460Light · inoperativeL1 DOOR EXTERIOR LIGHT INOP. RELAMPED L1 DOOR EXTERIOR EMERGENCY LIGHT. OPS CHECK OK. PER AMM 33-51-03.SDR UIEA2020070101461Mask · defectiveCOCKPIT 1ST OBS MASK HARNESS NO INFLATE. REMOVED AND REPLACED 1ST OBS MASK PER AMM 35-11-51 AND PERFORMED SYSTEM TEST AMM 35-51-00. OPS CHECK GOOD.SDR UIEA2020070101462Mask · leakingCOCKPIT 2ND OBS OXYGEN MASK HARNESS LEAKING. REPLACED 2ND OBS O2 MASK IAW MM 35-11-51. PERFORMED SYSTEM TEST IAW MM 35-51-00. OPS CHECK GOOD.SDR UIEA20200611275Apu · malfunctionedON ARRIVAL, APU DID NOT START. PERFORMED A BITE, NO FAULTS NOTED. APU OIL QTY SHOWED ZERO. AFTER RESET APU OIL SHOWED FULL. STARTED NORMAL IAW AMM 45-41-00.SDR UIEA2020060201195Ecu · malfunctionedAPU WILL NOT START ON THE GROUND. RESET ECU, OPS CK COMPLIED WITH IAW 49-60-00.SDR UIEA2020060101161Tube · malfunctionedCOCKPIT TEMPS EXTREMELY HOT WITH PACKS MAX COLD. REMOVED AND REPLACED REHEATER INLET TUBE IAW AMM CH 21-51-21. OPERATIONAL CHECK GOOD.SDR UIEA2020052201102Power Supply · inoperativeAFTER PRE DEPARTURE INSPECTION, FOUND LT AND RT EMERGENCY EXIT LIGHTED SIGNS INOP(<P>REMOVED AND REPLACED EMR LIGHT PWR SUPPLY M1209 AND OPS CHECK OK IAW MM 33-51-00.</P>)SDR UIEA2020051100973Engine · leakingDURING WALK AROUND, AFTER AIRCRAFT SITTING FOR 4 HOURS, FOUND PUDDLE OF OIL UNDERNEATH RIGHT ENGINE.(<P>RIGHT ENGINE REMOVED AND REPLACED. ACCOMPLISHED IAW ATLAS W/C A-71-999-04-02. ALL OPS CHK NORMAL.</P>)SDR UIEA2020050800992Indicator · failedDURING OP CHECK OF SEI THE SEI FAILED(<P>REMOVED AND REPLACED SEI (STAND BY ENGINE INDICATOR) AS PER B767-300 AMM 77-41-00 AND CHECKS GOOD.</P>)SDR UIEA2020050400940Warning System · false activationAPU FAULT ON LANDING.(<P>FOLLOWED FAULT TREE FIM 49-11 FT 987 - FOR APU ECU BITE - NO DATA DISPLAYED.</P><P>APU OPERATING NORMALLY AT THIS TIME IAW AMM 49-11-00.</P>)SDR UIEA2020050400942Solenoid Valve · faultyAFTER LEFT ENGINE SHUTDOWN INITIATED FUEL VALVE LEFT SIDE DID NOT CLOSE FOR FORTY SECONDS.(<P>REMOVED AND REPLACED LEFT ENGINE HP FUEL SHUTOFF SOLENOID VALVE IAW AMM 73-21-23. OPS CHECK GOOD.</P>)SDR UIEA2020042900911Oil System · lowAPU FAULT UPON LANDING(<P>INSPECTED APU SIGHT GLASS AND FOUND TO BE LOW. SERVICED APU WITH 02 QUARTS OF OIL IAW B767 AMM 12-13-04. OPS CHECK GOOD. APU STARTED FIRST ATTEMPT. NO DEFECTS NOTED.</P>)SDR UIEA2020042900917Control Valve · failedRH PACK TEMP CONTROL VALVE FAILED ON THE BITE CHECK.(<P>REMOVED AND REPLACED RH PACK TEMP CONTROL VALVE. OPS CHECK OK IAW AMM 21-51-12.</P>)SDR UIEA2020042800837Warning System · false activationAPU FAULT ON LANDING.(<P>PERFORMED APU BITE PER FIM 49-11 FT 987, NO FAULTS NOTED AT THIS TIME. OPS CHECK GOOD PER B767 AMM 49-11-00.</P>)SDR UIEA2020042800883Slide Raft · not reportedL1 DOOR SLIDE/RAFT REPLACEMENT REQUIRED.(<P>REMOVED AND REPLACED SLIDE/RAFT IAW AMM 25-66-01 EXP DATE 23MAY22.</P>)SDR UIEA2020042800884Medical Kit · not reportedEMK POS 01 LH FWD REQUIRES REPLACEMENT(<P>REMOVED AND REPLACED EMK POS 01 LH FWD IAW AMM 25-64-03.</P>)SDR UIEA2020042000765Warning System · false activationEICAS MESSAGE "R PACK TEMP"(<P>PERFORMED R PACK BITE TEST OF CONTROLLER, NO DEFECTS NOTED. OPS CHECKED GOOD. ALL SYSTEMS OK. REF B767 FIM 21-51 FT 803.</P>)SDR UIEA2020041000730Transceiver · malfunctionedRADAR SYSTEM 1 WEATHER FAIL MULTIPLE TIMES(<P>REMOVED AND REPLACED TRANSCEIVER PER AMM 34-43-01. OPS CHECK NORMAL.</P>)SDR UIEA2020033000568Warning System · false activationAFTER TAKEOFF "WXR FAIL" #1 RADAR. ASSOCIATED "WRX SYS" STATUS MESSAGE.(<P>PERFORMED BITE CHECK ON WXR IAW MM 34-43-00. NO DEFECTS NOTED.</P>)SDR UIEA2020032300532Pump · malfunctionedRT AFT MAIN BOOST PUMP INOP.(<P>TRANSFERRED TO MEL 28-22-01, MDDR 126137, CAT C, MBCB 01APR20. PLACARD INSTALLED. MAINT PROCEDURES C/W, AC RESTRICTED TO ETOPS 120.</P><P>LP <SPAN>1138686: </SPAN><SPAN>REMOVED AND REPLACED RH AFT MAIN BOOST PUMP ASSY IAW AMM 28SDR UIEA2020031200436Hook And Loop · defectiveCOCKPIT SMOKE VISION SYS INOP (COCKPIT SMOKE VISION SYSTEM (CSVS) (STC ST00731LA)).(<P>TRANSFERRED TO MDDR #125643 PER MEL 25-63-06, CAT 'D', DUE 09JUL20, PLACARD INSTALLED. DISPATCH NOTED.</P><P><SPAN>LP 1226536: </SPAN>CLEANED & INSTALLED NEW VELCRO AT CA &SDR UIEA2020022620307Actuator · inoperativeRIGHT PACK TEMP EICAS MESSAGE ON TAKE OFF ROLL.(<P>DEFERRED IAW MEL 21-51-03-01, MDDR 124975, CAT C, DUE 03MAR20, PLACARD INSTALLED.</P><P>LP 1226318: PERFORMED OPERATION TEST AND BITE CHECK OF CONTROLLER IAW AMM 21-61-00. NO MESSAGE NOTED, NO DEFECT NOTED. THSDR UIEA2020022630312Oxygen Mask · leaking1ST OBSERVER SEAT OXYGEN MASK LEAKING.(<P>DEFERRED IAW DDG 25-11-02-01A, MDDR 124970, CAT "A".</P><P>LP 1226318 - ITEM M8: REMOVED AND REPLACED 1ST OBSERVER OXYGEN MASK IAW AMM 35-11-00. NO DEFECTS NOTED. STOWED MASK IAW AMM 35-11-51. THIS CLEARS MDDR 124970.<SDR UIEA2020022090279Oxygen Bottle · inoperativeONE PORTABLE OXYGEN DISPENSING UNIT INOP AT MID CABIN BULK HEAD. (PORTABLE OXYGEN DISPENSING UNITS (BOTTLE AND MASK)). (REF LOG PAGE 1113589: REF MDDR 124817 PORTABLE O2 MASK MISSING)(<P>TRANSFERRED TO MDDR 124817 IAW MEL 35-31-01, CAT 'D'. </P><P>LP <SPAN>111SDR UIEA2020021300247Valve · malfunctionedRIGHT DUCT PRESSURE FLUCTUATED DURING TAKE OFF AND CLIMBED WITH HIGH THRUST SETTINGS.(<P>REMOVED AND REPLACED RT ENG PRV IAW 36-11-18-004-001-001. OPS CHECK GOOD.<BR /></P>)SDR UIEA2020021320245Warning Message · false activationAFTER TOUCHDOWN AT RMS, EICAS MSG, FWD EQPT COOLING.(<P>TROUBLESHOT SYSTEM IAW SSM 21-58-01 DIAGRAM AND OPS TEST IAW AMM 21-58-00, OPS CHECK TESTS NORMAL AT THIS TIME.<BR /></P>)SDR UIEA2020021320246Unknown · unknownRIGHT DUCT PRESSURE FLUCTUATING DURING ENG START AND ALL PHASES OF FLIGHT.(<P>PERFORMED OPS TEST OF AIR SUPPLY CONTROL SYSTEM IAW AMM 36-23-00, BIT OPS TEST PASSED. COULD NOT DUPLICATE FAULTS ON GROUND.<BR /></P>)SDR UIEA202002110227Relay · failedFOUND EQUIPMENT COOLING EICAS MESSAGE WITH NO COOLING LIGHT WERE ILLUMINATED UPON LANDING.(<P>REPLACED CENTER FAN CONTROL CARD, EXHAUST FAN CONTROL RELAY K1009 IAW FIM TASK 2158 TREE 905 AND EQUIPMENT COOLING IND. CARD PER MCC. DOESN'T HELP, T/S CONTINUES, THESDR UIEA2020020760202Sensor · malfunctioned#1 ENG BLEED OFF EICAS CAUTION DURING TAKEOFF AND CLIMB PORTION OF FLIGHT. ITEM M2: L DUCT PRESSURE INDICATED 10-15 PSI FOR DURATION.(<P>TRANSFER TO MDDR #124368 IAW MEL 36-12-02-01, CAT 'C', DUE DATE 16FEB20. ALL MX PROCEDURES C/W, ETOPS 120.</P><P>LP 1226297SDR UIEA2020020700206Warning Light · false activationMOMENTARY AND INTERMITTENT EICAS L ENG BLEED OFF MESSAGE. EXTINGUISHED AFTER APPROX 15 SEC. LT PRESSURE 12PSI, RT PRESSURE 30PSI.(<P>PERFORMED BLEED CONTROL SUPPLY SYSTEM BIT TEST IAW AMM 36-26-00. NO FAULTS NOTED AT THIS TIME. SYSTEM TESTS OK.</P>)SDR UIEA2020020710107Skin · corrodedCORROSION DAMAGES WERE FOUND ON THE HORIZONTAL STABILIZER TOP SKIN, CENTER SECTION, BETWEEN RIB 1 TO 2 NEAR FWD EDGE 3 SPOTS OF CORROSION, BETWEEN RBL 13.83/41.50 AND STGR 9/10.(<P>REPAIR FOR CORROSION ON THE HORIZONTAL STABILIZER CENTER SECTION, UPPER SKIN, BSDR UIEA2020020790142Housing · wornBULK CARGO DOOR OUTER SKIN HOUSING WITH WEAR.(<P>THE DAMAGED HOUSING WAS REPLACED IN ACCORDANCE WITH DRAWING 146T6301 AND CMM 52-36-16 PAR. 4F REV. 5 30MAY11.</P>)SDR UIEA2020020790144Skin · crackedCRACK INDICATION ON THE RH WING, LOWER SKIN, AT OUTBOARD SEGMENT OF STRINGER L-9.5 / BETWEEN WING STATION 990.2 AND WING STATION 1046.2.(<P>CRACK WAS REPAIRED IN ACCORDANCE WITH EO 6757A088.</P>)SDR UIEA2020020790146Strap · corrodedTWO CRACKS IN THE FWD CARGO COMPARTMENT STABILIZATION STRAP BETWEEN STA 654+110 / 654+121 AND / LBL 39.25.(<P>CRACKS WERE REPAIRED IN ACCORDANCE WITH SR 3-4611920191 AND SRM 53-30-51-01-1 DETAIL II.</P>)SDR UIEA2020020790147Skin · corrodedBULGE ON FUSELAGE SKIN FORWARD OF BS 676 BETWEEN STRINGER S-35L / S-36L.(<P>BULGE WAS REPAIRED AT STA 654+121 / 676 BETWEEN STRINGER S-35 / S-36 IAW <SPAN>SRM 53-00-01-1A-1 </SPAN><SPAN>TRE 6753334 AND FAA FORM 8100-9, REFERENCE ID: 202001150013-000301.</SPAN>SDR UIEA2020020700205Light · inoperativeFLIGHT DECK EMERGENCY EXIT LIGHT INOPERATIVE.(<P>EMERGENCY EXIT LIGHT WAS REPLACED IAW AMM 33-51-01-402-030. TEST WAS SATISFACTORY.</P>)SDR UIEA2020020650190Valve · malfunctionedLEFT DUCT PRESSURE MODULATED FROM 0 PSI TO NORMAL @ 12,000 FT. LEFT DUCT INDICATED 0 PSI @ FL 230, 5 MIN LATER RECORDS TO 14 PSI (RIGHT INDICATED 34 PSI). EICAS MESSAGE LEFT ENGINE BLEED OFF WAS ALSO INTERMITTENT (<P>FAN AIR VALVE WAS REPLACED DURING C-CHECK FSDR UIEA201912116046Target · out of adjustCENTER FUEL PUMPS DID NOT INHIBIT BEFORE ENGINE START. MX RESET FUELING DOOR.(<P>ADJUSTED TARGET ON FUELING DOOR IAW AMM 52-49-04 AND OPS CHECKED GOOD IAW AMM 28-22-00.</P>)SDR UIEA2019112205946Light · inoperativeISLE EMERGENCY LIGHT OUT @ R2 LAV.(<P>REINSTALLED EMERGENCY LIGHT AND LENS PER AMM 33-51-10, OPS CHECK NORMAL.</P>)SDR UIEA2019111985925Battery · inoperativeL4 AFT POSITION F/A FLASHLIGHT INOP. (<P>TRANSFERRED TO MDDR 120713 PER MEL 25-63-04A, CAT 'C', DUE DATE: 27-NOV-19. PLACARD INSTALLED. </P><P>LP 1114730 - M2: REMOVED AND REPLACED L/H AFT POSITION FLASHLIGHT BATTERY AND PERFORMED OPERATIONAL CHECK IAW AMM 25-SDR UIEA2019111985924Actuator · malfunctionedPERFORMED SQUIB TEST, FOUND IT EMER ESCAPE LEFT LIGHT WOULD NOT TEST AFTER MAINTENANCE RELEASE OF AIRCRAFT.(<P>REMOVED AND REPLACED SPOILER OVERRIDE ACTUATOR IAW B767 AMM 25-65-20, OPS CHECKS GOOD.<BR /></P><P>LP 1114713 - M3: REMOVED AND REPLACED RIGHT OFF-WISDR UIEA2019110105833Unknown · malfunctionedAFTER LANDING, APU DID NOT START, TWO ATTEMPTS.(<P>PERFORMED OPERATIONAL CHECK IAW AMM 49-60-00, APU STARTED, NO FAULTS NOTED.</P>)SDR UIEA2019102285751Bleed Air Sys · fluctuatesAPU BLEED PRESSURE FLUCTUATED BETWEEN 15 AND 22 PSI PRIOR TO START WITH NO LOAD.(<P>PERFORMED BITE TEST OF PNEUMATIC SYSTEM IAW AMM 36-23-00, NO FAULTS FOUND. OPS CHECKED APU AIR IAW B767 AMM 36-00-00.</P>)