N646AE
Service difficulty reports · 225
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N646AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N646AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20180712008Light · crackedLT #6 LIGHT STRIP EXTRUSION IS CRACKED. C/A-COMPLETE:REMOVED REPLACED LT #6 LIGHT STRIP EXTRUSION IAW AMM 33-50-12 ETN-EM-33-058. SEE BOW 298426 FOR INSTALLATION OPS CHECK.SDR SIMA20180712009Skin · crackedRT UPPER AFT FUSELAGE SKIN CRACKED IN 2 PLACES;PLACE1: JUST AFT OF FRAME 75 AND ABOVE STRINGER 2R CRACK IS APPROX. 3/8' LONG (MARKED), PLACE 2:SKIN CRACKED AT FIRST FASTENER BELOW STRINGER 2R ON FRAME 75, CRACK IS APPROX. 1/4" LONG. EASI #8071 USED WITH 50-500SDR SIMA20180626006Handle · dirtyMAIN DOOR NOT OPENING PROPERLY. INSPECTED AND FOUND HANDLE OF MAIN DOOR REQUIRING CLEANING AND LUBING. OPS CHECK GOOD IAW AMM 52-18-05.SDR SIMA20180626001Roller · lack of lubeMAIN CABIN DOOR DIFFICULT TO OPEN. FOUND RT LOWER ROLLER HARD TO MOVE. LUBRICATED MAIN CABIN DOOR ROLLERS AND OPC GOOD IAW AMM REF 52-10-01.SDR SIMA20180625002Acm · failedEXPERIENCED A BURNING SMELL IN THE COCKPIT WITH A SMOKY HAZE BUILDING IN THE COCKPIT, DISSIPATED AS WE DESCENDED. PERFORMED TROUBLESHOOTING PER FIM 21-20-00. FOUND NR 1 PACK ACM TO HAVE FAILED. REMOVED AND REPLACED NR 1 PACK ACM PER AMM 21-51-03. OPC GOOD. SDR SIMA20180312003Light · inoperativeRIGHT OVERWING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE EMERGENCY LIGHT IAW AMM 33-50-10, OPS CHECKED GOOD.SDR SIMA20171011003Lamp · inoperativeSERVICE DOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE LAMPS IAW AMM 33-50-09-000-801-A, AND 33-50-09-400-801-A.. OPS CHECKED GOOD.SDR SIMA20170519003Warning Message · false activationTURBULACE DURING DECENT HAD LG AIR/GROUND FAIL. QRH PENALTY APPLIED, NORMAL LANDING, EICAS MESSAGE, LG AIR/GROUND FAIL REMOVED AT TOUCHDOWN. INSPECTED WOW SWITCHES, INSURED CONNECTORS SECURE IAW AMM 32-63-05, ALL CONNECTORS SECURE NO FURTHER DEFECTS NOTED.SDR SIMA20170512003Proximity Sensor · failedLANDING GEAR AIR GROUND FAIL MESSAGE ON EICAS AT 8000FT. WHILE FOLLOWING FIM TASK 32-63-00, FOUND THE LT MLG NR 2 PROXIMITY SWITCH AND RT NR 1 PROXIMITY SWITCH GAPS WERE OUT OF LIMITS ADJUSTED IAW AMM 32-63-05. REMOVED AND REPLACED THE RT MLG WOW NR 1 PROXIMSDR SIMA20170501001Proximity Sensor · failedLG AIR /GND FAIL CAUTION MSG WHILE CLIMBING THROUGH FL 300 "TRANSFERRED TO NRWC 646-MIA-02812". FOLLOWING FIM TASK 32-63-00-810-806A, LANDING GEAR LEFT WOW PROX SW FAIL MESSAGE ON CMC, REMOVED AND REPLACED LEFT MLG DOWN LOCK PROXIMITY SW POSITION B, OPERATIONASDR SIMA20170206002Metering Unit · failedFUEL LEAKING OUT OF NR 1 ENGINE NACELLE. REMOVED AND REPLACED FPMU NR 1 IAW AMM 73-21-01. OPS CHECK GOOD NO LEAKS NOTEDSDR SIMA20160625002Roller · out of adjustMAIN CABIN DOOR DIFFICULT TO OPEN FROM THE OUTSIDE. R & R UPPER AND LOWER FWD TEFLON GUIDES AND ADJUSTED THE FWD UPPER ROLLER IAW AMM 52-18-00. OPS CHECK GOOD.SDR SIMA20160623006Sign · inoperativeEMERGENCY EXIT SIGN AFT OF RT OVERWING EXIT INOPERATIVE. FOUND ON CLOSE-UP. R & R EMERGENCY EXIT SIGN AFT OF RT OVERWING EXIT IAW AMM 33-50-13, CHECK GOOD.SDR SIMA20160622003Rib · crackedRIGHT RIB 5 CRACKED AT THE AFT LARGE LIGHTNING HOLE. ACCOMPLISHED PERMANENT REPAIR TO RT RIB 5 IAW ERS-EM-57MR-648 01 AND ERS-EM-57MR-648.SDR SIMA20160620005Door Sill · corrodedSERVICE DOOR AFT SILL HAS CORROSION AROUND FWD NUTPLATE. REMOVED CORROSION FROM SERVICE DOOR, AROUND SILL AND NUTPLATE, REPLACED IAW SRM 51-40-09.SDR SIMA20160618007Frame · gougedSIDEWALL PANEL SUPPORT BETWEEN STR-13R, FRAME 65 GOUGED. REPAIRED FRAME 65 LAW SRM 51-40-02, 51-20-01 AND 53-00-04.SDR SIMA20160612004Wire · brokenLEFT NR 4 EMERGENCY LIGHT STRIP HAS BROKEN WIRE. FOUND ON OPEN-UP, R & R LEFT NR 4 EMERGENCY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20160606006Yoke · crackedLEFT ENGINE FWD LOWER YOKE FWD FITTING CRACKED. REMOVED AND INSTALLED SERVICEABLE YOKE IAW EO EM-54MR-386.SDR SIMA20160527004Sign · inoperativeEMERGENCY EXIT SIGN AFT OF RT OVERWING EXIT INOPERATIVE. R & R EMERGENCY EXIT SIGN AFT OF RT OVERWING EXIT IAW AMM 33-50-13, OPS CK GOOD.SDR SIMA20160527005Wire · brokenLEFT NR 4 EMERGENCY LIGHT STRIP HAS A BROKEN WIRE. R & R LT NR 4 EMERGENCY LIGHT STRIP IAW AMM 33-50-12. OPS CK GOOD IAW AMM 33-50-00.SDR SIMA20160426002Electronic Unit · faultyNO LG IN TRANSIT DURING RETRACTION OR EXTENSION. WITH 3 GREEN UP & UP SELECTED RMU SHOWED LG DOWN & LOCKED. AFTER FURTHER INVESTIGATION FOUND LGEU TO BE AT FAULT. R & R LGEU IAW AMM 32-32-01. OPERATIONS CHECK GOOD, NO FURTHER DEFECTS NOTED.SDR SIMA20160417001Flashlight · inoperativeCAPTAIN FLASHLIGHT INOPERATIVE. R & R CAPTAINS FLASHLIGHT IAW AMM 33-50-16. OPERATIONS CHECKED GOOD.SDR SIMA20160211001Light · inoperativeAFT EMER FLOOR LIGHTING STRIP INOPERATIVE. R & R AFT EMER FLOOR LIGHTING STRIP. OPERATIONS CHECKED GOOD IAW AMM 33-50-12.SDR SIMA20151218002Wire Harness · damagedAFTER TAKEOFF & ROTATION & GEAR RETRACTION A LOUD & RAPID CLANKING NOISE EMANATING FROM FLIGHT DECK. R & R NR 2 NLG DOWNLOCK PROX HARNESS & PROX SWITCH IAW AMM 32-61-02. OPERATIONS CHECKED GOOD IAW NRWC 646-DFW-02207 FOR DETAILS.SDR SIMA20151208002Bushing · wornAFTER TAKEOFF A VERY LOUD CONTINUOUS & RANDOM CLACKING OR SPARKING SOUNDS WERE IMMEDIATELY HEARD IN THE COCKPIT. FLIGHT RETURNED WITHOUT INCIDENT. TRANSFERRED TO NRWC 646-ABI-02199. R & R BUSHINGS TO RAM AIR VLV & ADJUSTED LINEAR ACTUATOR IAW AMM 21-25-03. SDR SIMA20151108002Inverter · inoperativeFORWARD EMER LIGHT EXIT SIGN INOPERATIVE. R & R NR 1 INVERTER. OPERATIONS CHECKED GOOD IAW AMM 33-50-11.SDR SIMA20151031003Battery · dischargedAFT CEILING EMER LIGHT AT PANEL 263 ALC INOPERATIVE. R & R EMER LIGHT BATTERY & CHARGER AT ROW 15 CEILING IAW AMM 33-50-04. OPERATIONS CHECKED GOOD IAW AMM 33-50-00. BATTERY CHARGER ASSEMBLY PN 11-0049 & SN 13314.SDR SIMA20150605002Battery · dischargedDURING PS2 CHECK, FOUND EMER LIGHTS NOT ILLUMINATING, FLOOR STRIPS 6, 7 & 8. R & R NR 4 BATTERY POWER SUPPLY IAW MM 33-50-04. R & R NR 4 BATTERY IAW MM 33-50-04. OPERATIONS CHECKED GOOD. CHARGER ASSEMBLY BATTERY, PN BA5-0933-901 & SN C01447.SDR SIMA20150308001Flashlight · inoperativeCAPTAINS COCKPIT FLASHLIGHT INOPERATIVE. REPLACED FLASHLIGHT IAW AMM 33-50-16. FLASHLIGHT CHECKED GOOD.SDR SIMA20150305002Pump · failedENGINE 1 HYD FAIL. COMPLIED WITH AOM VOL 1, LOWERED GEAR ON FINAL. NORMALLY HYD 1 ENG FAIL MSG WENT AWAY. REMOVED & INSTALLED NEW HYD PUMP 1 ENG IAW AMM 29-10-03. OPERATIONS CHECKED GOOD.SDR SIMA20150302004Holder · brokenAFT CABIN EMER FLASHLIGHT HOLDER BROKEN. R & R AFT EMER FLASHLIGHT HOLDER IAW AMM 33-50-16.SDR SIMA20150227002Light · inoperativeSEAT 3 & 4 FLOOR EMER LIGHT STRIP INOPERATIVE. DEFERRED IAW MEL 33-30. R & R FWD AMBER FLOOR PROXIMITY LIGHT STRIP EMER AMM CH 33-50-12. MEL RESTORED.SDR SIMA20150120002Cradle · brokenFLIGHT ATTENDANT`S EMER FLASH LIGHT CRADLE BROKEN. R & R FLIGHT ATTENDANT`S EMER FLASHLIGHT CRADLE IAW AMM 33-50-16-000-801-A & 33-50-16-400-801-A. OPERATIONS CHECKED GOOD.SDR SIMA20141203006Fairing · crackedFORWARD BELLY FAIRING CRACKED. REPAIRED FWD BELLY FAIRING IAW ERS-ERS-EM-5300-741.SDR SIMA20141006002Unknown · odorSMELL OF ELEC BURNING DURING DESCEND & PARKING. COMPLIED WITH ETN-EM-72-034, PERFORMED ENG RUNS & INSPECTIONS OF ELEC AREAS, FOUND NO DAMAGE.SDR SIMA20140529007Connector · brokenFOUND THE NR 1 LT AISLE PROXIMITY LIGHT STRIP CONNECTOR ON ACFT SIDE BROKEN OFF. REPAIRED NR 1 AISLE LIGHT STRIP CONNECTOR SP9019 ACFT SIDE IAW SWPM 20-00-03, 20-21-00 & WM 91-10-02.SDR SIMA20140527012Wire · brokenNUMBER 6 FLOOR PROXIMITY LIGHT STRIP HAS BROKEN WIRES. R & R NR 6 EMER LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20140527008Wire · brokenNUMBER 4 FLOOR PROXIMITY LIGHT STRIP HAS BROKEN WIRES. R & R NR 4 EMERGENCY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20140527010Wire · brokenNR 5 FLOOR PROXIMITY LIGHT STRIP HAS BROKEN WIRES. R & R NR 5 EMERGENCY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20140527009Wire · brokenNR 7 FLOOR PROXIMITY LIGHT STRIP HAS BROKEN WIRES. R & R NR 7 EMERGENCY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20140527007Wire · brokenNUMBER 3 FLOOR PROXIMITY LIGHT STRIP HAS BROKEN WIRES. R & R NR 3 EMERGENCY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20140525007Frame · chafedFRAME 15 & ADJACENT SHEAR CLIP CHAFED STRINGER 2R. PERFORMED PERMANENT REPAIR OF FRAME 15 & REPLACED SHEAR CLIP IAW ERS-EM-53MR-470.SDR SIMA20140525008Door · corrodedCARGO DOOR CORRODED AT UPPER END FWD SCREW HOLE. PERFORMED PERMANENT REPAIR IAW ERS-EM-52MR-145.SDR SIMA20140503009Pin · disconnectedPILOTS FLASHLIGHT HAS NO CHARGE. RECONNECTED PIN IAW WM 91-10-02 & SWPM 20-00-03, LED CHARGE LIGHT NOW ILLUMINATED, OPERATIONS CHECKED GOOD.SDR SIMA20140503005Fastener · corrodedLEFT PITOT TUBE HAS CORRODED HARDWARE. R & R LT PITOT TUBE HARDWARE IAW AMM 34-13-01STEPS 2J 2B & STEPS 3I 6.SDR SIMA20140503008Shroud · corrodedRIGHT WING AILERON LWR SHROUD MOUNTING FLANGE OTBD 9 NUTPLATE HOLES HAVE CORROSION AROUND THE NUTPLATE HOLE. RT WING AILERON LWR SHROUD MOUNTING FLANGE OTBD 10 NUTPLATE HOLES HAVE CORROSION AROUND THE NUTPLATE HOLE FOUND TO BE ACCEPTED IAW ERS-EM-5700-151. SDR SIMA20140503006Skin · crackedFUSELAGE EXTERNAL SKIN CRACKED AROUND 1 FASTENER FRAME 78 RT SIDE BELOW VERTICAL STAB. INSTALLED REPAIR BUSHING ON FUSELAGE EXTERNAL SKIN AT FRAME 78 ON RT SIDE BELOW VERTICAL IAW ERS-EM-5300-453.SDR SIMA20140503007Panel · brokenNR 5 PROXIMITY LIGHT PANEL COVER LIP BROKEN. R & R NR 5 PROXIMITY LIGHT STRIP SIDEWALL ASSEMBLY IAW AMM 33-50-12. OPERATIONAL CHECKED GOOD.SDR SIMA20140306001Roller · lack of lubeFLIGHT ATTENDANT SAID MAIN CABIN DOOR STICKS & HARD TO OPEN. LUBRICATED ROLLERS IAW SMP, DOOR OPERATED NORMALLY.SDR SIMA20140228010Brake Sys · contaminatedFIRST OFFICER`S LANDED, INITIAL BRAKING 50% EFFECTIVENESS AT BEST, TRANSFERRED TO CAPTAIN AT 90 KTS, SAME ON CAPTAIN'S BRAKES 50% AT BEST. USED REVERSE THRUST TO SLOW DOWN, EICAS CAUTIONS CAME ON BRAKE DEGRADED & THEN BRAKE OTBD INOPERATIVE AT APPROXIMATELY 3