N646UA
Service difficulty reports · 313
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N646UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N646UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013030501314O-Ring · cutFLUID LEAK RIGHT INBOARD SPOILER. FOUND HYDRAULIC LEAK COMING FROM THE NR 10 SPOILER ACTUATOR FILTER HOUSING. FOUND CAP O-RING CUT. REPLACED NR 10 SPOILER FILTER, PACKINGS AND FILTER COVER O-RINGS PER MM. LEAKED CHECK AND OPERATED SPOILERS AND NO LEAKS NOTSDR UALA2013021200832Transmitter · inoperativeNO WATER PRESSURE THROUGHOUT ACFT QTY SHOWS 150 GAL AND HOLDING STEADY. NO AIR COMING FROM FAUCETS WHEN OPENED. ALL LAVATORIES DRY FLUSHING. REPLACED WATER QTY TRANSMITTER AND PRESSURE SWITCH, OPS CHECKED GOOD. NO LEAKS NOTED.SDR UALA2013020800762Hose · disconnectedSLIDE INFLATION HOSE DISCONNECTED FROM BOTTLE, LEFT SLIDE BOTTLE. INSTALLED AND SECURED SLIDE INFLATION HOSE.SDR UALA2013020700750Bottle · misinstalledLEFT OVERWING INFLATION BOTTLE BALL IN THE MIDDLE OF INFLATION CABLE IS NOT INSTALLED BEHIND THE RETAINER SPRING. REMOVED LEFT OVERWING INFLATION BOTTLE AND REPLACED IAW AMM 25-65-02.SDR UALA2013012900527Connector · looseEMERGENCY LIGHT INOPERATIVE. SECURED LOOSE CONNECTOR, OPS NORMAL.SDR UALA2013012900526Lamp · inoperativeEMERGENCY LIGHT AT SEAT 33J INOPERATIVE. REPLACED LAMP, OPS NORMAL.SDR UALA2013012900525Connector · unsecureEMERGENCY LIGHT INBD AFT GALLEY INOPERATIVE. SECURED LOOSE CONNECTOR AT LAMP, CHECKED OKAY.SDR UALA2013012900524Lamp · inoperativeEMERGENCY LIGHT ABOVE COCKPIT DOOR INOPERATIVE. REPLACED LAMPS, CHECKED OKAY.SDR UALA2013012400410Module · malfunctionedLOW PRESSURE LIGHT ILLUMINATED POS 1 (01=1,02=2). EICAS MESSAGE DISPLAYED C HYD PRIM (1,2). FRM CODE 29-11-07 --. TROUBLE SHOT PER MM AND FOUND TIME DELAY MODULE M303 AT FAULT. REPLACED M303 IAW WD 29-11-31. TESTED PER MM 201 AND 501 AND TESTED NORMALLY.SDR UALA2012121007118Controller · failedNR 2 ENGINE HP CONTROLLER FAILED HEALTH CHECK, NEEDS REPLACEMENT. REPLACED NR 2 ENGINE HP CONTROLLER AMM.SDR UALA2012121007154Shutoff Valve · failedNR 2 ENGINE PRSOV FAILED HEALTH CHECK, NEEDS REPLACEMENT. (SEE AMSITM 3642073 FOR FAILED MM STEP). REMOVED AND REPLACED NR 2 ENGINE PRSOV.SDR UALA2012121007119Shutoff Valve · failedNR 2 ENGINE PRV FAILED HEALTH CHECK. REPLACED NR 2 ENGINE PRV AMM 36-11-18. COMPLETED UP TO AND INCLUDING STEP D-13 PAGE 413.SDR UALA2012121007153Thermostat · faultyON ENGINE RUN RT ENGINE ON HIGH STAGE AIR FLUX + - 5 PSI. AFTER RUNNING ENGINE ON HI STAGE FOR APPROX 10 MIN (PACK ON) AND SHIFTING TO LOW STAGE, LOW STAGE AIR BLED TO ALMOST ZERO. (SUSPECT TEMP THEROMOSTAT). REPLACED RT ENGINE FAN AIR TEMP SENSOR PER MM 36SDR UALA2012121007147Panel · shearedDURING FLAP RETRACTION PANEL SEPARATED FROM AIRCRAFT AT LEFT FUSELAGE WING TO BODY FAIRING BY LEFT INBD T/E FLAP. REMOVED TORQUE TUBE FOR SHEARED DOOR PER MM 27-51-07. CONT OF AMIS ITEM 3642044. INSTALLED REPLACEMENT FAIRING DOOR AND TORQUE TUBE ASSY AS REQSDR UALA2012121007129Light · inoperativeEXT MID SLIDE GRD ILLUM LIGHT RIGHT SIDE INOPERATIVE. RELAMPED, OPS NORMAL.SDR UALA2012121007130Connector · disconnectedFWD EEL LIGHT AT SEAT 9AB INOPERATIVE. FOUNDED CONNECTOR DISCONNECTED. RECONNECTED, CHECKS NORMAL.SDR UALA2012121007126Light · inoperativeEEL LIGHT AT SEAT 35JK INOPERATIVE. RELAMPED, OPS NORMAL.SDR UALA2012121007125Light · inoperativeEEL LIGHT AT SEAT 38AB INOPERATIVE. RELAMPED, OPS NORMAL.SDR UALA2012121007124Light · inoperativeEEL LIGHT AT SEAT 20AB INOPERATIVE. RELAMPED, OPS NORMAL.SDR UALA2012121007123Light · inoperativeEMERGENCY CEILING LIGHT INOP AT 8JK. RELAMPED, OPS NORMAL.SDR UALA2012121007120Lens · missingEMERGENCY CEILING LIGHT AT 6JK MISSING LENS. REPLACED LENS.SDR UALA2012121007128Light · inoperativeEEL LIGHT AT SEAT 37JK INOPERATIVE. RELAMPED, OPS NORMAL.SDR UALA2012121007127Light · inoperativeEEL LIGHT AT SEAT 36JK INOPERATIVE. RELAMPED, OPS NORMAL.SDR UALA2012111206500Valve · faultyPACK 'INOP' & 'PACK OFF' LIGHTS ON. EICAS MSG 'R PACK OFF' DISPLAYED. COULD NOT RESET FIG 105A BLOCK 1. REPLACED FCSO VAVLE.SDR UALA2012110706412Audio Panel · faultyF/O'S MIC SELECT PANEL BACKGROUND LIGHTS INOP. FOUND AS STATED SWAPPED W ITH FIRST OBSERVERS AUDIO SELECT PANEL TO COMPLY WITH MEL F/O'S AUDIO SELECT PANEL, ALL OPS CHECKS GOOD. REMOVED AND REPLACED AUDIO SELECTOR PANEL IAW AMM, OPS CHECK NORMAL. REMOVED PASDR UALA2012102306067O-Ring · leakingSPOILER ON THE RIGHT SIDE 5 OUTBOARD FROM THE FUSELAGE IS LEAKING. FOUND NR 10 SPOILER LEAKING HYD FLUID FROM FILTER CAP. REPLACED O-RING. OP'S CHECK NORMAL. NO LEAKS NOTED.SDR UALA2012102206035Coffeemaker · sparksCREW REPORTED WHEN FLT ATTENDANT MOVED LEVER ON COFFEEMAKER M51 IN RT AFT GALLEY TO REMOVE BREW TRAY, COFFEEMAKER SPARKED AND LIGHT SMOKE NOTICED. FLIGHT ATTENDANT PULLED C/B FOR M51 AT RIGHT AFT GALLEY POWER CONTROL PANEL. NO FURTHER SMOKE OR SPARKS NOTICEDSDR UALA2012100405632Actuator · failed"AIL LOCK" LT ON AT HIGH SPEED. EICAS MSG "AILERON LOCKOUT" DISPLAYED. OUTBOARD AILERONS INDICATED MOVEMENT - UNLOCKED, BOTH. CREW COMMENTS: 290 KNOTS AT 13,000FT,TEMP -8, THE RT SAM HAD AN ADC AND A LT AILERON LOCKOUT ACTUATOR FAULTBALL. BOTH DID RESET. SDR UALA2012092405411Starter · faultyAPU FAULT ON START WILL NOT START. TORUBLESHOT AS PER MM AND REMOVED AND REPLACED APU STARTER AS PER MM. OPS CHECKS GOOD. PCN 651-1150.SDR UALA2012091905316Sense Line · looseSPLIT DUCT PRESSURES AT CRUISE. L-18 R-42 AT FL39 RT ENG HPSOV SECURED CLOSED. FOUND SENSE LINE ON NR 2 HP VALVE LOOSE. SECURED LINE. PERFORMED ENGINE RUN UP ALL BLEED PARAMETERS NORMAL.SDR UALA2012091405201Warning System · false activation'L PACK INOP' LIGHT ON. EICAS MSG 'L PACK TEMP' DISPLAYED. OPERATED NORM AFTER 'STANDBY' SELECTED. L ZONE TEMP CONTROLLER SHOWED RAM AIR OUTLET ACT. RESET AND VERIFY OK PACK OPS OK IN AUTO.SDR UALA2012091205127Angle · crackedNR 1 PYLON MID SPAR O/B LOWER TANG CLOSE OUT ANGLE, HFEC INDICATES CRACKED O/B MOST AFT FASTENER (CRACK INDICATED ON AFT SIDE) :CORRECTION-SHOULD BE MID SPAR I/B LOWER TANG. :VERIFIED CRACK WITH FPI INSPECTION AND NOTIFIED FOREMAN. PERM REPAIR WAS ACP'D REF SDR UALA2012090705046Fitting · crackedNR 1 PYLON MIDSPAR FITTING LOWER I/B TANG-PERFORM OPEN HOLE HFEC INSPECTION REF TASK 54-51-92-206-802 THE 2 MOST AFT FASTENERS AT THE CLOSEOUT ANGLE (AD 2010-14-18). ACP OPEN HOLE HFEC PER ND TM PART6 51-00-16 OF NR 1 PYL MIDSPAR LOWER INBD FITTING. FOUND CSDR UALA2012083104896Transmitter · defectiveRT QTY EICAS MSG, RTFL. DISPLAYED AND RIGHT QTY LIGHT ILLUMINATED ON OVERHEAD PANEL. QTY INDICATION INDICATED RF ON STATUS PAGE. FLT CREW TURNED OFF RIGHT HYD PUMPS PER QRH PROCEDURE. DURING RETURN TO FIELD CREW STATED QTY STABILIZED. PUMPS TURNED ON PER SDR UALA2012082404764Module · faultyEICAS MSG SPOILERS DISPLAYED. SPOILERS LIGHT ILLUM WITH SPOILERS SELECTED TO ARMED POSITION. TROUBLESHOT AND FOUND M53 0 SPOILER CONTROL MODULE AT FAULT. REMOVED AND REPLACED IAW AMM. PERFORMED SYSTEM TEST, ALL TEST NORMAL, OK TO CONTINUE.SDR UALA2012082304710Wire · severedREF DF983, SEAT 8J EEL LIGHT WIRES SEVERED ON ACCOUNT OF SHEARED OTTOMAN FOOTREST. REPLACED EEL LIGHT ASSEMBLY, OPS CHECK GOOD.SDR UALA2012080804303Connector · dirty80 KTS A RT HYD QTY EICAS ILLUMINATED AND HYD QTY SHOWED .57 AND RAPIDLY DECREASING. CLEANED CONNECTOR. PRESSURIZED RH HYDRAULIC SYSTEM. CHECKED HYDRAULIC QUANTITY. SAME QUANTITY IN COCKPIT AND AT RESERVOIR.SDR UALA2012073004118Indicator · inoperativeLOST RT UPPER CRT, RTFL. RIGHT UPPER CRT DEAD. REPLACED FIRST OFFICERS EADI IAW AMM.SDR UALA2012072404020Computer · inoperativeCAPTAIN'S FLIGHT DIRECTOR INOPERATIVE. REPLACED LT FCC PER AMM.SDR UALA2012071803915Shutoff Valve · failedLT ENGINE HPSOV EICAS MSG. ACCOMPLISHED PNEUMATIC HEALTH CHECK OF THE HPSOV-HPC SYSTEM. AILED ITEM C (22) & (27). RESISTANCE READINGS NOT WITHIN LIMITS. HPSOV. REPLACED HIGH PRESSURE CONTROLLER PER MM. PERFORMED ENGINE RUN, OPS CHECKED NORMAL. ACCOMPLISSDR UALA2012071103726Bleed Valve · failedOVERHEAD BLEED LIGHT ON EICAS LT ENGINE HPSOV AND LT ENGINE HPSOV STATUS MESSAGE. HPSOV IS LOCK CLOSED. REPLACED VALVE NEEDS ENGINE RUN TO OPS CHECK VALVE. AFTER RUN STILL NO GOOD. AFTER VALVE CHANGE AND ENGINE RUN. THE STATUS OF THE PROBLEM HAS BEEN CHANGED.SDR UALA2012070203515Microphone · inoperativeNR 1 VHF NO TRANSMIT OR RECEIVE ON BOTH HEADS OF RADIO. NR 1 AND NR 3 VHF SETS INTERCHANGED NO GOOD. VHF CONTROL HEADS INTERCHANGED NO GOOD, AUDIO SELECTORS INTERCHANGED AND CAPTAINS AND F/O'S MIC`S INTERCHANGED ALL OPS RETURNED TO NORMAL. SUSPECT NR 1 MICSDR UALA2012060803154Slide · detachedCUSTOMER SERVICE INADVERTENTLY OPENED DOOR 2L AND PARTIALLY DEPLOYED ESCAPE SLIDE. SLIDE UNIT DETACHED FROM DOOR 2L. DOOR SECURED CLOSED PER MEL 52-11H.SDR UALA2012032301850Fitting · leakingNR 2 ENGINE HAS HYDRAULIC LEAK. REPLACED QUICK DISCONNECT FITTING ON SUPPLY LINE TO NR 2 ENG EDP RAN ENGINE, OPS CHECKS NORMAL.SDR UALA2012031301641Coupler · leakingNR 2 ENG HYD PUMP RETURN LINE COUPLER LEAKING AT PYLON. RMV'D LINE & QUICK DISCONNECT FITTING NEED TO INSTALL NEW LINE & NEW QUICK DISCONNECT FITTING. RMV'D AND PARTIALLY INSTALLED NEW PUMP PER MM. MR29157 DASH 3 REMOVED AND DASH 444 INSTALLED.SDR UALA2012030101288Battery · faultyMAIN BATTERY CHARGER STATUS MSG. REPLACED MAIN BATTERY AND BATTERY CHARGER PER MM, OPS CKS GOOD. CLEARED MESSAGE. BATTERY READING 29 VOLTS.SDR UALA2012021400867Hydraulic System · unknownHYDRAULIC FLUID DRIPPING FROM NR 2 ENGINE. OPENED RT NACELLE, HYD FLUID WETNESS IN AREA OF EDP AND HYD LINES. CLEANED & DRIED. RAN ENGINE 5 MINS, REINSPECTED, NO LEAKS NOTED. HYD QTY CHECKED GOOD.SDR UALA2012020600711Valve · faultyDIFFICULT TO CONTROL TEMP IN COCKPIT. MIX VALVE SHOWS FULL WARM WITH COLD AIR STILL BLOWING. FLT DECK TRIM VLV SHOWS WARM, BUT COLD AIR IS COMING IN, CREW CYCLED MASTER TRIM VLV AND OPERATED FLT DECK TRIM VLV IN MANUAL, NO HELP. REPLACED TRIM AIR VALVE.SDR UALA2012012600548Engine · surgesNR 2 ENG SURGE DURING T/O. ABORTED T/O AT 40KTS. RPLC NR 2 ENG SN 717690 DUE ENGINE SURGE, RESULTING IN ABORTED TAKEOFF & RECENT PARAMETER SHIFT. RMV'D NR 2 ENG SN 717690. INSTALLED ENG 727968.SDR UALA2012011000224Light · inoperativeEEL LIGHT STRIP BETWEEN DOORS 1 RT AND 1 LEFT JUST AFT OF G1 GALLEY INOP. REPLACED EEL STRIP IAW B767 GNMM 2-0-15-005. OPS CHECKS GOOD.
Back to N646UA