As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NR 1 PYLON MIDSPAR FITTING LOWER I/B TANG-PERFORM OPEN HOLE HFEC INSPECTION REF TASK 54-51-92-206-802 THE 2 MOST AFT FASTENERS AT THE CLOSEOUT ANGLE (AD 2010-14-18). ACP OPEN HOLE HFEC PER ND TM PART6 51-00-16 OF NR 1 PYL MIDSPAR LOWER INBD FITTING. FOUND CRACK INDICATION FOR BOTH HOLES. MFG STRAP REPAIR.