N647AE
Service difficulty reports · 251
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N647AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N647AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2021081000354Light · inoperativeAFT CEILING EMERGENCY LIGHT INOPERATIVE. REMOVED ROW 12 CEILING LIGHT COVER PANEL AND ROW 12CEILING PANEL. R&R LIGHT ASSY IAW AMM 33-50-15-04 AND INSTALLED THE CEILING PANEL AND CEILING LIGHT COVER PANEL USING RETAINED HARDWARE.SDR HNAA2021050500195Charger · malfunctionedAFT EMERGENCY LIGHTS ILLUMINATE WHEN NO POWER APPLIED TO AIRCRAFT. REMOVED & REPLACED #400 EMERGENCY BATTERY CHARGER ASSY IN REF TO AMM 33-50-04-000/400-801-A. PERFORMED EMERGENCY LIGHT SYSTEM OPS CHECK IAW W/C 33-70-17. OPS CHECK GOOD. SEE HA-300 SEQ #6 FORSDR HNAA2021050300166Fan · failedDURING CLIMB THROUGH 20,000 FT ELECTRICAL FUMES NOTED IN COCKPIT. SMELL EVENTUALLY DISSIPATED. UPON ARRIVAL TO AC NO SMELL NOTED. EXAMINED RH LH PANELS AND FWD AVI BAY. FOUND #2 EXHAUST FAN INOP. R+R FAN IN REF TO AMM 21 26 02. FOUND NO POWER AT INVERTER. R+SDR HNAA2021020200040Door Sill · corrodedSSI 53-20-10 SERVICE DOOR CENTEER SILL CORRODED AROUND NUT PLATE HOLES....PERFORMED HFEC INSPECTION AND UT THICKNESS IAW EASI NDTM NO RELEVANT INDICATION NOTED,-.068"-.072" MATERIAL REMAINING....PERFORMED HFEC INSPECTION AND UT THICKNESS IAW EASI NDTM NO RELEVSDR HNAA2021020200034Skin · damagedEXTERNAL FUSELAGE SKIN HAS CREASE BTW FRAMES 19-20, STRINGER 13-14L....REPAIRED EXTERNAL FUSELAGE SKIN HAS CREASE BETWEEN FRAMES 19-20, STRINGER 13-14L IAW PIEDMONT EO1-53-21-0018.SDR HNAA2021020200039Skin · gougedCARGO DOOR INTERNAL LOWER WEB HAS GOUGES, HOLES IN SKIN.....REPAIRED CARGO DOOR INTERNAL LOWER WEB GOUGES, AND HOLES IN SKIN IAW PIEDMONT EO1-52-21-0019.SDR HNAA2021020200037Rib · crackedLH WING RIB 21 CRACKED. PERFORMED REPAIR ON L/H WING RIB 21 IAW EMB 145 SRM 57-20-07 ITEM 4, FIGURE 203 AND EO1-57-21-0009.SDR HNAA2021020200036Skin · crackedEXTERIOR FUSELAGE SKIN IS CRACKED BETWEEN FR 59-60 STR 4L-5L. INSTALLED REPAIR DOUBLER AND FILLER FOR SKIN CRACK REPAIR BETWEEN FR59 AND 60 AND STGR 4L-5L IAW EO1-53-21-0008SDR HNAA2021020200035Skin · dentedCARGO DOOR EXTERNAL SKIN HAS 22 DENTS.....CARGO DOOR EXTERNAL SKIN DENTS #1-7, AND #9-22 ARE ACCEPTED AS PERMANENT ALLOWABLE DAMAGE IAW EO1-52-21-0007. (CUTOUT AND DOUBLER REPAIR)SDR HNAA2021020200038Yoke · crackedRH ENGINE LOWER FWD YOKE APPEARS TO BE CRACKED.....PERFORMED HFEC INSPECTION IAW EASI NDTM RELEVANT INDICATION NOTED ET EASI 8958....REMOVED AND REPLACED THE RH ENGINE LOWER FORWARD YOKE IAW PIEDMONT EO1-54-20-0448.SDR HNAA2021020200041Connector · brokenFLOOR PROXIMITY LIGHT STRIP CONNECTOR AT PANEL 251HF IS BROKEN....REPLACED BROKEN FLOOR PROXIMITY LIGHT STRIP CONNECTOR AT PANEL 251HF IAW EMB 145 SWPM 20-21-00.SDR HNAA2020111200324Wire · burnedFOUND BURNED/CHAFED WIRE AT NR 3 PITOT/STATIC HEATING CONNECTION ON PITOT/STATIC PORT. AFTER REPAIR, PERFORM FCD1-30-16-0172. REMOVED AND REPLACED CONNECTOR P0089, WIRE W102-1271-16N FROM P0089 TO GS0575 AND WIRE W102-0270-16 FROM P0089 BASE XK0058 PIN C3. SDR HNAA2020012200027Control Unit · smokeDURING CLIMB OUT CREW NOTICED SMELL, THEN DURING CRUISE SMELL REMAINED WITH SMOKE COMING FROM GLARE SHIELD AREA.....FIX: R&RD FLIGHT GC IAW EMB 145 AMM 22-11-01,OPS CHECK GOOD AT THIS TIME,OK FOR SERVICE. NOTE: CREW DONNED 02 MASKS EMERGENCY DESCENT. CONTINUESDR HNAA2019122000389Drain Line · failedCAPT,S AND F/O SPEED INDICATORS OFF BY 15 KNOTS AND FLASHING YELLOW IAS SPEED. REJECTED T/O.....FIX: R&RD PITOT 2 DRAIN LINE AS REQ,D. REF LP 226938-3. PERFORMED LEAK TEST IAW EMB AMM 34-13-00. LEAK CHECK GOOD. OK FOR SERVICESDR HNAA2019100700303Engine · odorLAVATORY SMOKE EICAS MESSAGE DISPLAYED AFTER TAKE OFF, F/A REPORTED SMOKE IN AFT CABIN. THE NR 2 ENGINE WAS REMOVED AND REPLACED AT A MAINTENANCE VISIT.SDR HNAA2019100700300Unknown · odorLAVATORY SMOKE MESSAGE ON EICAS AT 400 FT. SMELLED SMOKE IN CABIN AND LAVATORYSHE ALARM WENT OFF. R & R THE LAVATORY SMOKE DETECTOR AND TESTED PER AMM 16-14-02. OPS CHECK GOOD. OK FOR RETURN TO SERVICE IAW FIM 26-14-00-810-802-A. TROUBLESHOOTING SMELLED SUSDR HNAA2019100700299Smoke Detector · false activationLAVATORY SMOKE ALARM WENT OFF AFTER TAKEOFF. STRANGE CAME FROM GALLEY. R & R THE LAVATORY SMOKE SENSOR IAW AMM 26-14-01 AND OPS CHECK IAW AMM 26-14-00, OPS CHECK OK FOR SERVICE.
RAN BOTH ENGINES WITH AND WITHOUT BLEED 1 AND 2, PACKS 1 AND 2 AT HIGH POWERSDR HNAA20190806Blade · damagedNR 2 ENGINE FAN BYPASS VANES DAMAGED. REPLACED ALL 15 FAN BLADES IAW ENG MANUAL 72-25-10-400-801.SDR HNAA2019080600211Fairing · damagedRIGHT WING TIP FAIRING DAMAGED. R & R WING TIP FAIRING IAW AMM 57-30-00-400-801-A.SDR HNAA2019052200146Flow Sensor · defective647 73-30 2007141 19MAY19 CHS CLOSE NR 1 ENG FUEL FLOW WENT TO ZERO ON EICAS AND RMU DURING T/O ROLL. HISTORY: NONE
MEL 19MAY19 10:55 CHS C13909 73-6 FUEL FLOW INDICATORS FACT 21MAY19 04:59 PHL R&R RUEL FLOW SENSOR IAW MM 73-35-10. OPSSDR HNAA2019042200107Light · inoperativeNDIS 647 33-20 0007870 20APR19 RIC CLOSE
EXIT ROW EMERGENCY LIGHT ON RH SIDE WON'T ILLUMINATE
FACT 20APR19 09:51 RIC
REMOVED & REPLACED RH OVERWING EMERGENCY LIGHT IN RE
F TO AMM 33-50-13-000/400-801-A OK FOR SERVISDR HNAA2019031100072Light · inoperativeNDIS 647 33-51 0006820 06MAR19 ROA CLOSE LT, FWD EMERGENCY LIGHT IS INOP FACT 06MAR19 10:47 ROA R&R THE LAMP/BULB ON THE LT, FWD EMERG LIGHT OPS CHECK GOOD OKAY FOR SERVICE AT THIS TIME PART INSTALLED/REMOVED LAMP/BULB - 8330012 SN N/A.SDR HNAA2019030400060Light · inoperativeNDIS 647 33-40 0006660 01MAR19 SBY CLOSE RT OVERWING EMERGENCY LIGHT INOP. 35718 00 SPE FACT 01MAR19 11:48 SBY R & R EMERGENCY LIGHT IAW TASKS 33-50-14-000-801-A AND 33-50-14-400-801-A.SDR HNAA2018101100252Inverter · malfunctioned115 VOLT AC BUS OFF ON T/O ROLL, REJECTED T/O. R&R STATIC INVERTER IAW AMM 24-20-01-04. OPS CHECKS GOOD AT THIS TIME.SDR HNAA2018070400130Access Door · lack of lubeACCESS DOOR OPEN EICAS MSG. DOOR SCREEN SHOWS FWD ACCESS HATCH. HATCH IS CLOSED (C/W MX PROCEDURE). LUBRICATED FWD NOSE ACCESS DOOR AND ACCOMPLISHED OPS CK IAW AMM 52-71-00-710-002A.SDR SIMA2018052309006Trunnion · crackedLEFT WING MLG AFT UPPER TRUNION WAS CRACKED AT THE OUTBOARD LOWER RADIUS. COMPLIED WITH ERS-EM-57MR-965.SDR SIMA2018051402008Rib · crackedRIB ABOVE CAPTAINS WINDSHIELD HAS A 1/4 INCH CRACK AROUND THE NUTPLATE HOLE. REPAIRED THE RIB IAW SRM-53-12-16.SDR SIMA2018051601013Support Bracket · crackedLEFT OVERWING ROOT FAIRING L BRACKET SUPPORT ON UPPER WING SURFACE IS CRACKED. REPAIRED IAW ETN-EM-53-142.SDR SIMA2018051401012Bulkhead · crackedLT MLG WHEEL WELL AT THE AFT BULKHEAD WALL HAS TWO CRACKS. INSTALLED THE BULKHEAD IAW SRM 51-40-02.SDR SIMA2018051401009Support Bracket · crackedLEFT OVERWING ROOT FAIRING SUPPORT BRACKET ON THE UPPER SURFACE WAS FOUND CRACKED, JUST INBD OF THE GROUND SPOILER. REPAIRED THE SUPPORT BRACKET IAW ETN-EM-53-142SDR SIMA2018051401011Support Angle · crackedRIGHT WING TO FUSELAGE UPPER SUPPORT ANGLE FOUND CRACKED, 1 INCH LONG AT FRAME 42. REAPIRED IAW SRM 53-23-12.SDR SIMA201805141010Support Angle · crackedRIGHT WING TO FUSELAGE UPPER SUPPORT ANGLE IS CRACKED 2 1/2 ICHES LONG AT FRAME 49. REPAIRED IAW SRM 53-23-12.SDR SIMA2018051401008Support Angle · crackedLEFT WING TO FUSELAGE UPPER SUPPORT ANGLE WAS FOUND CRACKED, 1 1/2 INCH LONG AT FRAME 48. REPAIRED IAW SRM 53-23-12.SDR SIMA2018060613Wire · damagedILLUMINATED EXIT SIGN HAD A DAMAGED WIRE. REPLACED THE EXIT SIGN.SDR SIMA2018060612Wire · damagedNR 8 FLOOR EMERGENCY LIGHT STRIP WIRING WAS DAMAGED AT THE BASE OF THE STRIP. REMOVED AND REPLACED THE LIGHT STRIP IAW AMM 33-50-12.SDR SIMA2018060614Light · detachedCABIN FLOOR EMERGENCY LIGHT DEBONDED FROM STRIP. INSTALLED THE EMERGENCY LIGHT IAW AMM 33-50-12.SDR SIMA201806056011Light · damagedCABIN FLOOR EMERGENCY LIGHT STRIP NR 1 WAS DAMAGED. REMOVED AND REPLACED THE EMERGENCY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA201806056010Light · inoperativeCABIN FLOOR EMERGENCY LIGHT STRIP NR 6 WAS DAMAGED. REMOVED AND REPLACED THE EMERGENCY LIGHT IAW AMM 33-50-12.SDR SIMA20180402002Charger · failedFOUND EMERGENCY LIGHT TO BE INOPERATIVE IN GALLEY. REMOVED AND REPLACED THE BATTERY AND CHARGER IAW IAW AMM 33-50-04. OPS CHECKED GOOD. NO FURTHER DEFECTS NOTED.SDR SIMA20180326002Bulb · inoperativeRIGHT EXTERIOR WING EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED THE OVERWING EMERGENCY LIGHT BULB IAW AMM 33-50-07, OPS CHECKED GOOD.SDR SIMA20180221003Light · inoperativeNR 4 AISLE EMERGENCY LIGHT INOP PER PS-2 CHECK. REMOVED AND REPLACED LAMP ON NR 4 AISLE EMERGENCY LIGHT IAW AMM 33-50-08. OPS CHECK GOOD.SDR SIMA20180122006Bulb · inoperativeROW 17 EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE BULB IAW AMM 33-50-08-000-801-A, AND 33-50-08-400-801-A. OPS CHECKED GOOD.SDR SIMA20171124002Cable · malfunctionedMAIN DOOR WILL NOT OPEN FROM OUTSIDE. REMOVED AND REPLACED INTERNAL HANDLE CABLE IAW AMM 52-18-09, OPS CHECKED GOOD.SDR SIMA20171113002Wire Splice · damagedNR 7 FLOOR EMERGENCY LIGHT INOPERATIVE. TROUBLESHOT IAW WM 33-50-50. FOUND THE SPLICES SP9113 AND SP9114 BAD. R & R THE WIRE SPLICES IAW SWPM 20-50-01, NO FURTHER DEFECTS NOTED.SDR SIMA20171019004Flashlight Assy · brokenAFT FA FLASHLIGHT BROKEN AND NOT WORKING. REMOVED AND REPLACED THE FLASHLIGHT IAW AMM 33-50-16. OPS CHECKED GOOD. NO FURTHER DEFECTS NOTED.SDR SIMA20170914004Cam · out of adjustMAIN ENTRY DOOR HARD TO OPEN AND CLOSE. ADJUSTED THE FWD CAM OF THE SIDE HINGED ON MAIN DOOR IAW AMM 52-18-00, AND ETN EM-52-029. INTERNAL ACTUATING HANDLE TESTED GOOD.SDR SIMA20170905004Bulb · inoperativeDURING PS-1, FOUND THE LAST ASILE EMERGENCY LIGHT INOPERATIVE. REPLACED THE BULB IAW AMM 33-50-08, OPS CHECKED GOOD.SDR SIMA20170821003Roller · lack of lubeMAIN CABIN DOOR DIFFICULT TO OPEN. LUBRICATED THE DOOR ROLLERS. PERFORMED A TEST OF MAIN DOOR IAW AMM 52-10-01. OPS CHECKED GOOD.SDR SIMA20170608001Seal · detachedMAIN DOOR GETS STUCK WHEN OPENING AND IS DIFFICULT TO OPEN. INSPECTED AND FOUND RUBBER TRIM SEAL AT TOP REAR CORNER DETACHED. REPAIRED IAW AMM 52-00-04. OPS CHECKED NORMAL. ACFT OK FOR SERVICESDR SIMA20170603003Bulb · inoperativeMAIN CABIN DOOR EMERGENCY LIGHT COVER BROKEN AND LIGHT INOPERATIVE. MAIN CABIN DOOR EMERGENCY LIGHT COVER AND LIGHT BULB REPLACED IAW AMM 20-21-00