N649GT
Service difficulty reports · 574
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N649GT' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N649GT' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2016121200998Circuit Card · malfunctionedSTATUS MESSAGE FOR RT ENG OVERHEAT LOOP 1. REMOVED AND REPLACED THE OVERHEAT DETECTOR IAW AMM 26-11-02-424-033, AND REMOVED AND REPLACED M689 FIRE DETECTOR CARD IAW AMM TASK 26-10-01-024-024. OPS CHECK GOOD.SDR UIEA2016121200999Blade · damagedNR 1 ENGINE LP COMPRESSOR BLADES LEADING EDGES HAVE NICKS. BLENDED THE COMPRESSOR BLADES IAW AMM 72-31-02-308-045-400, & 70-11-06-232-001-1400.SDR UIEA2016121201000Blade · damagedTHE NR2 ENGINE HAS 14 FAN BLADES HAVE NICKS ON THE L/E OF BLADES . BLENDED THE FAN BLADES IAW AMM 72-31-02-308-045-H00.SDR UIEA2016121201001Lamp · unsecureSEVERAL EXTERIOR EMERGENCY LIGHTS INOPERATIVE. CLEANED AND RESEATED THE LAMPS IAW AMM 33-51-00-715-200 & BSWPM 20-10-04. OPS CHECKED GOOD.SDR UIEA2016111400840Overheat Loop · false indicationSTATUS MESSAGE RT ENGINE OVERHEAT LOOP 1. COMPLIED WITH FIRE DETECTION BITE PROCEDURE, FIM 26-11 FT 808, MESSAGE CLEARED, SYS OK.SDR UIEA2016102700824Bulb · inoperativeNR 2 ENGINE OIL TEMPERATURE BLANKED OUT, AND FLUCTUATES INTERMITTENTLY. REMOVED AND REPLACED NR 2 ENGINE OIL TEMPERATURE BULB IAW AMM 79-34-01 NO LEAKS FOUND , OPS CHECKED NORMAL.SDR UIEA2016102200819Valve · malfunctionedLEFT A/C PACK NO PACK OFF LIGHT AND L PACK OFF EICAS MESSAGE. REMOVED AND REPLACED THE LEFT FLOW CONTROL AND SHUTOFF VALVE IAW AMM 21-51-01. OPS AND LEAK CHECKED NORMAL.SDR UIEA2016101500809Warning Message · false activationAPU FAULT EICAS MESSAGE DURING START, & AFTER LANDING. PERFORMED APU ECU BITE IAW FIM 49-11 FT 958 RESET ECU EICAS MESSAGE CLEARED APU START NORMAL.SDR UIEA2016092900789Sensor · faultyLEFT PACK TEMP EICAS. REMOVED AND REPLACED LEFT PACK OUTLET TEMP SENSOR. CLEARED MESSAGE, OPS CHECKS GOOD REF AMM 21-51-06.SDR UIEA2016092800788Warning System · false activationLT PACK TEMP EICAS MSG. T/S IAW FIM 21-51 FT 803. NO FAULTS NOTED. OPS CK, OK FOR SVC.SDR UIEA2016093000791Warning System · false activationLEFT PACK TEMP EICAS INFLIGHT. PERFORMED PACK TEMP CONTROLLER BITE PROCEDURE IAW FIM 21-51- FT 803, NO FAULTS NOTEDSDR UIEA2016092700777Shutoff Valve · malfunctionedLEFT PACK TEMP EICAS INFLIGHT(<P>PERFORMED PACK TEMP CONTROLLER BITE PROCEDURE IAW FIM 21-51 FT 803 NO FAULTS NOTED SYS OK. </P><P>PER FIM 21-61 FT 808 R&R TRIM AIR PRSOV IAW AMM 21-61-06/401-404. SYS OPS TEST NORMAL. THIS CLEARS MDDR CONT # 70477. PLACARD RSDR UIEA2016092300771A/C Pack · faultyALL TEMP ZONES IN AUTOMATIC, WOULD NOT WARM IT'S ZONE PAST 21 DEGREES C. LT PACK INOPERATIVE IN AUTO. TRANSFERRED TO MEL 21-51-03-01, CAT C, MDDR 70477.SDR UIEA2016091500761Warning Light · false activationLEFT PACK OVERHEAT ILLUMINATED. QRH COMPLETED. LT PACK RUNS IN " N" POSITION. PERFORMED PACK TEMP CONTROLLER BITE PROCEDURE IAW FIM 21-51 FT803 NO FAULTS NOTED SYS OK.SDR UIEA2016090900753Control Valve · defectiveOBSERVED LT PACK OVERHEAT EICAS QRH COMPLETE AND LT PACK RUN IN N-POSITION, LP 788170-3, TRANSFERRED TO MEL 21-51-03-01 CAT-C; LP 788180, M8. R & R TEMP CONTROL VALVE REF AMM 21-51-03. THIS CLEARS MDDR 70063. OPS CK OK.SDR UIEA2016090700750Warning System · activatedLT PACK EICAS MSG TEMP. REPLACED LT PACK TEMP CONTROL VALVE IAW AMM 21-51-12, PRECAUTIONARY. PART BAD, REINSTALLED ORIGINAL PACK TEMP CONTROL VALVE , T/S IAW FIM 21-51, FAULT TREE 803, SYS CHECK OK.SDR UIEA2016090600734Control Valve · malfunctionedLEFT PACK TEMP EICAS TS IAW FIM 21-51- FT 803 FOUND LT TEMP CONTROL VALVE FAULT. RESET SYS OPS CHECK GOOD.SDR UIEA2016090100728O-Ring · leakingOIL COOLER BYPASS VALVE LEAKING, APU. REPLACED APU OIL COOLER BYPASS VALVE O-RINGS IAW AMM 49-27-10-404-006, STEP 1 A-F, ACCOMPLISHED LEAK CHECK IAW AMM 49-11-00-802-002.SDR UIEA2016081800688Warning Message · false activationRIGHT ENG PRV STATUS MESSAGE. PERFORMED AIR SUPPLY BITE PROCEDURE IAW FIM 36-20-00/104. NO FAULTS NOTED, EICAS MESSAGE CLEARED.SDR UIEA2016081800687Control Valve · inoperativeRIGHT A/C PACK FLOW CONTROL VALVE INOPERATIVE. R & R RT FLOW CONTROL VALVE IAW AMM 21-51-01, OPS CK OK.SDR UIEA2016081800686Warning Message · false activationRIGHT ENGINE PRV STATUS MESSAGE. PERFORMED AIR SUPPLY BITE PROCEDURE IAW FIM 36-20-00/101 FIG 104. NO FAULTS NOTED, EICAS MESSAGE CLEARED.SDR UIEA2016081500681Warning Message · false activationSTATUS MESSAGE FOR RT ENGINE PRV. IAW FIM 36-10-FT 847 PERFORMED AIR SUPPLY BITE PROCEDURE IAW FIM 36-20-00/101 FIG 104. NO FAULTS NOTED. EICAS MSG CLEARED.SDR UIEA2016081100678Warning System · false activationRT ENGINE PRV EICAS ON CLIMBOUT IAW FIM 36-10, FT 847 PERFORMED AIR SUPPLY BITE PROCEDURE IAW FIM 36-20-00/101, FIG 104, NO FAULTS NOTED EICAS MSG CLEARED.SDR UIEA2016080900676Controller · malfunctionedZONE TEMP CONTROLLER UNABLE TO MAINTAIN TEMP FLIGHT CREW MODULATION TRIM AIR TO MAINTAIN TEMP. PERFORMED TASK 21-51-14-705-075, PACK TEMP CONTROLLER BITE FOUND LT TSMP COND VALVE FAULT, TESTED GOOD. BITE TEST ZONE TEMP CONTROLLER. AUX ZONE TEMP CONTROLLER SDR UIEA2016080800672Compensator · inoperativeCENTER FUEL QTY INOPERATIVE. REPLACED COMPENSATOR ASSY FOR CENTER MAIN TANK IAW AMM 28-41-02-001-001.SDR UIEA2016080400667Connector · looseFWD EICAS MESSAGE FOR RT ENGINE FIRE LOOP 1 AND 2. PERFORMED TROUBLESHOOTING IAW FIM 26-11 FT 804, FOUND HI & RES C PIN. FOUND 1 & 2 LOWER LOOP CONNECTOR LOOSE. SECURED IAW AMM 26-11-02 TEST GOOD & IAW AMM 26-11-00.SDR UIEA2016072900644Warning System · false activationLT PACK TEMP CAUTION MESSAGE AND 451646 MT/S IAW AMM 21-51-00 RESET FAULT NO DEFECTS NOTED.SDR UIEA2016072800643Circuit Card · malfunctionedEICAS STATUS MESSAGE FOR RT ENGINE FIRE LOOP NR 2. REPLACED NR 2 LOOP PRINTED CIRCUIT CARD FOR RT ENG IAW AMM 26-11-02.SDR UIEA2016072500624Unknown · malfunctionedEICAS LT PACK TEMP INTERMITTENT DURING CRUISE. T/S IAW FIM 21-51, FT 844 BITE PROCEDURES, SYS CHECK GOOD.SDR UIEA2016072500626Warning Message · false activationLT PACK TEMP EICAS MSG RECEIVED AT CRUISE. PERFORMED CHECKLIST, CLEARED EICAS MSG. PERFORMED BITE TEST IAW AMM 21-51-00-705, NO DEFECTS NOTED.SDR UIEA2016072600631Warning Message · false activationFWD EQUIPMENT OVERHEAT EICAS MESSAGE RECEIVED DURING CLIMB. CHECKLIST PERFORMED, EICAS MESSAGE CLEARED IAW CHECKLIST T/S IAW FIM 21-58-F/T 912, NO DEFECTS NOTED.SDR UIEA2016072400623Fire Detector · faultyRT ENGINE FIRE LOOP 2 EICAS MSG. TRANSFER TO MDDR 68667 IAW MEL 26-11-01-01, CAT C, DUE DATE 03-AUG 2016, PLACARD INSTALLED. REMOVED AND REPLACED NR 2 ENG UPPER AFT FIRE DETECTOR AS PER AMM 26-10-02 OPS CHECK NORMAL, MDDR CLEARED.SDR UIEA2016072200620Warning System · false activation2 STARTS ON APU BOTH RESULTED IN APU FAULT, CLEARED, APU START NORMAL. PERFORMED APU BITE PROCEDURES IAW FIM 49-11, FT 958 FAULTS CLEARED. APU START NORMAL.SDR UIEA2016071900595Cooling Fan · failedFWD EQUIPMENT SUPPLY FAN 1 EICAS MESSAGE. CIRCUIT BREAKER WILL NOT RESET. REMOVED AND REPLACED COOLING SUPPLY FAN IAW AMM 21-58-06. OPS CHECK GOOD.SDR UIEA2016072000602Controller · inoperativeFWD AND AFT TEMP TEMP CONTROLLERS INOPERATIVE. PERFORMED ZONE TEMP CONTROLLER BITE IAW AMM 21-61, FAULT TREE 803, NO FAULTS NOTED. SYS CHECK OK.SDR UIEA2016072100610Controller · malfunctionedCREW REPORTED INTERMITTENT LT PACK TEMP EICAS MESSAGE. REMOVED AND REPLACED THE LT PACK TEMP CONTROLLER ASSY SYS BITE TEST OK IAW AMM 21-51-14/404.SDR UIEA2016071500586Fire Loop · faultyRIGHT ENGINE FIRE LP 2 EICAS MESSAGE TRANSFERRED TO MDDR 68398 IAW 26-11-01-01, CAT C. REMOVED AND REPLACED UPPER AFT LOOP IAW AMM 26-11-02. OPS CK OK. MDDR 68398 CLEARED.SDR UIEA2016071400582Detector · faultyEICAS MSG FWD CARGO DET 1, TRANSFERRED TO MDDR 68348 IAW MEL 26-16-01-01-01, CAT C. REMOVED AND REPLACED FWD CARGO NR 1 DETECTOR IAW AMM 26-16-01. OPS CHECK OK.SDR UIEA2016071400581Warning Message · false activationLEFT PACK TEMP EICAS MESSAGE. PERFORMED PACK TEMPERATURE CONTROLLER BITE TEST. BITE TESTED OK, NO MESSAGE FOUND IAW AMM 21-61-12-715.SDR UIEA2016071100574Hose · leakingLEAKING RUBBER HOSE IN LEFT PACK BAY DISCOVERED DURING WALKAROUND. SECURED THE LINE AND RECONNECTED IAW AMM 21-51-03, NO LEAKS NOTED.SDR UIEA2016070700567Circuit Card · failedNR 2 ENGINE FIRE LOOP 2 MESSAGE EICAS. REPLACED NR 2 ENGINE LOOP 2 FIRE DETECTION PRINTED CIRCUIT CARD IAW AMM 26-10-01. CHECKED OK.SDR UIEA2016070700565Circuit Card · failedWHEN LEFT PACK TURNED OFF, NO PACK OFF LIGHT AND NO L PACK OFF EICAS MESSAGE. REPLACED LEFT PACK FLOW CONTROL PRINTED CIRCUIT CARD IAW AMM 21-51-09. OPS CHECKED GOOD.SDR UIEA2016070700566Shutoff Valve · malfunctionedSTATUS MESSAGE RT IDG VALVE. REPLACED IDG AIR OIL HEAT EXCHANGER AIR SHUTOFF VALVE IAW AMM 24 11-07 OPS AND LEAK CHECKED OK.SDR UIEA2016070400562Fluid · lowRIGHT IDG VALVE STATUS TROUBLESHOOTING, FIM 24-20, FT 802. NO DEFECT NOTED ADDED ONE PINT, OIL TO IDG OK FOR SERVICES.SDR UIEA2016070700570Circuit Card · failedLT ENGINE SPEED CARD EICAS MESSAGE DISPLAYED. REPLACED LT ENG N2 SPEED CARD IAW AMM 73-21-54. OPS CHECKED GOOD.SDR UIEA2016070200558Switch · defectiveDURING ENGINE START RT ENGINE VALVE LIGHT FAILED TO CYCLE LAMP TEST CONFIRMED THAT THE LIGHT WAS FUNCTIONING PROPERLY. PLACED ON DEFERRAL. REPLACED SW LIGHT IAW 33-13-00. OPS CK OK IAW 28-22-01. THIS CLEARS MEL.SDR UIEA2016062200453Status Message · false activationSTATUS MESSAGE, FORWARD CARGO DETECTOR 1 PERFORMED LOWER CARGO SMOKE DETECTION SYS BITE IAW FIM 26-16, FT 806. SYS CHECKS OK, EICAS MESSAGE CLEARED.SDR UIEA2016062300455Warning System · activatedFLIGHT DECK TEMP EICAS, IN FLIGHT DECK TEMP, INOPERATIVE LIGHT ILLUMINATED MANUAL CONTROL, WORKS OK. PERFORMED ZONE TEMP CONTROL BITE PROCEDURE IAW FIM 21-61.SDR UIEA2016062300457Control Valve · faultyINTERMITTENT LT PACK OFF, EICAS MESSAGE DURING DESCENT. TRANSFERRED TO MDDT 67731 IAW MEL 21-51-03-01, CAT C. REMOVED AND REPLACED LEFT ACM TEMP CONTROL VALVE AS PER AMM 21-51-12. OPS CHECK NORMAL.SDR UIEA2016062300458Status Message · false activationFUEL QTY TOTALIZER INOPERATIVE STATUS MESSAGE. QTY BITE IAW FIM 28-41 F/T 852, NO FAULTS AT THIS TIME.
Back to N649GT