N649GT

Service difficulty reports · 574

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N649GT' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR UIEA2016121200998Circuit Card · malfunctionedSTATUS MESSAGE FOR RT ENG OVERHEAT LOOP 1. REMOVED AND REPLACED THE OVERHEAT DETECTOR IAW AMM 26-11-02-424-033, AND REMOVED AND REPLACED M689 FIRE DETECTOR CARD IAW AMM TASK 26-10-01-024-024. OPS CHECK GOOD.Dec 11, 2016 · N649GT · Boeing 767375 · Overheat DetectionSDR UIEA2016121200999Blade · damagedNR 1 ENGINE LP COMPRESSOR BLADES LEADING EDGES HAVE NICKS. BLENDED THE COMPRESSOR BLADES IAW AMM 72-31-02-308-045-400, & 70-11-06-232-001-1400.Dec 11, 2016 · N649GT · Boeing 767375 · Turbine Engine Compressor SectionSDR UIEA2016121201000Blade · damagedTHE NR2 ENGINE HAS 14 FAN BLADES HAVE NICKS ON THE L/E OF BLADES . BLENDED THE FAN BLADES IAW AMM 72-31-02-308-045-H00.Dec 11, 2016 · N649GT · Boeing 767375 · Turbine Engine Compressor SectionSDR UIEA2016121201001Lamp · unsecureSEVERAL EXTERIOR EMERGENCY LIGHTS INOPERATIVE. CLEANED AND RESEATED THE LAMPS IAW AMM 33-51-00-715-200 & BSWPM 20-10-04. OPS CHECKED GOOD.Dec 11, 2016 · N649GT · Boeing 767375 · Emergency LightingSDR UIEA2016111400840Overheat Loop · false indicationSTATUS MESSAGE RT ENGINE OVERHEAT LOOP 1. COMPLIED WITH FIRE DETECTION BITE PROCEDURE, FIM 26-11 FT 808, MESSAGE CLEARED, SYS OK.Nov 12, 2016 · N649GT · Boeing 767375 · Overheat DetectionSDR UIEA2016102700824Bulb · inoperativeNR 2 ENGINE OIL TEMPERATURE BLANKED OUT, AND FLUCTUATES INTERMITTENTLY. REMOVED AND REPLACED NR 2 ENGINE OIL TEMPERATURE BULB IAW AMM 79-34-01 NO LEAKS FOUND , OPS CHECKED NORMAL.Oct 26, 2016 · N649GT · Boeing 767375 · Engine Oil Indicating SystemSDR UIEA2016102200819Valve · malfunctionedLEFT A/C PACK NO PACK OFF LIGHT AND L PACK OFF EICAS MESSAGE. REMOVED AND REPLACED THE LEFT FLOW CONTROL AND SHUTOFF VALVE IAW AMM 21-51-01. OPS AND LEAK CHECKED NORMAL.Oct 22, 2016 · N649GT · Boeing 767375 · Cabin Cooling SystemSDR UIEA2016101500809Warning Message · false activationAPU FAULT EICAS MESSAGE DURING START, & AFTER LANDING. PERFORMED APU ECU BITE IAW FIM 49-11 FT 958 RESET ECU EICAS MESSAGE CLEARED APU START NORMAL.Oct 15, 2016 · N649GT · Boeing 767375 · Airborne Auxiliary Power Unit (APU) SystemSDR UIEA2016092900789Sensor · faultyLEFT PACK TEMP EICAS. REMOVED AND REPLACED LEFT PACK OUTLET TEMP SENSOR. CLEARED MESSAGE, OPS CHECKS GOOD REF AMM 21-51-06.Sep 29, 2016 · N649GT · Boeing 767375 · Cabin Cooling SystemSDR UIEA2016092800788Warning System · false activationLT PACK TEMP EICAS MSG. T/S IAW FIM 21-51 FT 803. NO FAULTS NOTED. OPS CK, OK FOR SVC.Sep 28, 2016 · N649GT · Boeing 767375 · Cabin Cooling SystemSDR UIEA2016093000791Warning System · false activationLEFT PACK TEMP EICAS INFLIGHT. PERFORMED PACK TEMP CONTROLLER BITE PROCEDURE IAW FIM 21-51- FT 803, NO FAULTS NOTEDSep 26, 2016 · N649GT · Boeing 767375 · Cabin Cooling SystemSDR UIEA2016092700777Shutoff Valve · malfunctionedLEFT PACK TEMP EICAS INFLIGHT(<P>PERFORMED PACK TEMP CONTROLLER BITE PROCEDURE IAW FIM 21-51 FT 803 NO FAULTS NOTED SYS OK. </P><P>PER FIM 21-61 FT 808 R&R TRIM AIR PRSOV IAW AMM 21-61-06/401-404. SYS OPS TEST NORMAL. THIS CLEARS MDDR CONT # 70477. PLACARD RSep 26, 2016 · N649GT · Boeing 767375 · Cabin Cooling SystemSDR UIEA2016092300771A/C Pack · faultyALL TEMP ZONES IN AUTOMATIC, WOULD NOT WARM IT'S ZONE PAST 21 DEGREES C. LT PACK INOPERATIVE IN AUTO. TRANSFERRED TO MEL 21-51-03-01, CAT C, MDDR 70477.Sep 22, 2016 · N649GT · Boeing 767300 · Cabin Cooling SystemSDR UIEA2016091500761Warning Light · false activationLEFT PACK OVERHEAT ILLUMINATED. QRH COMPLETED. LT PACK RUNS IN " N" POSITION. PERFORMED PACK TEMP CONTROLLER BITE PROCEDURE IAW FIM 21-51 FT803 NO FAULTS NOTED SYS OK.Sep 15, 2016 · N649GT · Boeing 767375 · Cabin Cooling SystemSDR UIEA2016090900753Control Valve · defectiveOBSERVED LT PACK OVERHEAT EICAS QRH COMPLETE AND LT PACK RUN IN N-POSITION, LP 788170-3, TRANSFERRED TO MEL 21-51-03-01 CAT-C; LP 788180, M8. R & R TEMP CONTROL VALVE REF AMM 21-51-03. THIS CLEARS MDDR 70063. OPS CK OK.Sep 8, 2016 · N649GT · Boeing 767375 · Cabin Cooling SystemSDR UIEA2016090700750Warning System · activatedLT PACK EICAS MSG TEMP. REPLACED LT PACK TEMP CONTROL VALVE IAW AMM 21-51-12, PRECAUTIONARY. PART BAD, REINSTALLED ORIGINAL PACK TEMP CONTROL VALVE , T/S IAW FIM 21-51, FAULT TREE 803, SYS CHECK OK.Sep 6, 2016 · N649GT · Boeing 767375 · Cabin Cooling SystemSDR UIEA2016090600734Control Valve · malfunctionedLEFT PACK TEMP EICAS TS IAW FIM 21-51- FT 803 FOUND LT TEMP CONTROL VALVE FAULT. RESET SYS OPS CHECK GOOD.Sep 6, 2016 · N649GT · Boeing 767375 · Cabin Cooling SystemSDR UIEA2016090100728O-Ring · leakingOIL COOLER BYPASS VALVE LEAKING, APU. REPLACED APU OIL COOLER BYPASS VALVE O-RINGS IAW AMM 49-27-10-404-006, STEP 1 A-F, ACCOMPLISHED LEAK CHECK IAW AMM 49-11-00-802-002.Aug 29, 2016 · N649GT · Boeing 767300 · APU Oil SystemSDR UIEA2016081800688Warning Message · false activationRIGHT ENG PRV STATUS MESSAGE. PERFORMED AIR SUPPLY BITE PROCEDURE IAW FIM 36-20-00/104. NO FAULTS NOTED, EICAS MESSAGE CLEARED.Aug 17, 2016 · N649GT · Boeing 767375 · Pneumatic Distribution SystemSDR UIEA2016081800687Control Valve · inoperativeRIGHT A/C PACK FLOW CONTROL VALVE INOPERATIVE. R & R RT FLOW CONTROL VALVE IAW AMM 21-51-01, OPS CK OK.Aug 16, 2016 · N649GT · Boeing 767375 · Cabin Cooling SystemSDR UIEA2016081800686Warning Message · false activationRIGHT ENGINE PRV STATUS MESSAGE. PERFORMED AIR SUPPLY BITE PROCEDURE IAW FIM 36-20-00/101 FIG 104. NO FAULTS NOTED, EICAS MESSAGE CLEARED.Aug 16, 2016 · N649GT · Boeing 767375 · Pneumatic Distribution SystemSDR UIEA2016081500681Warning Message · false activationSTATUS MESSAGE FOR RT ENGINE PRV. IAW FIM 36-10-FT 847 PERFORMED AIR SUPPLY BITE PROCEDURE IAW FIM 36-20-00/101 FIG 104. NO FAULTS NOTED. EICAS MSG CLEARED.Aug 12, 2016 · N649GT · Boeing 767375 · Central WarningSDR UIEA2016081100678Warning System · false activationRT ENGINE PRV EICAS ON CLIMBOUT IAW FIM 36-10, FT 847 PERFORMED AIR SUPPLY BITE PROCEDURE IAW FIM 36-20-00/101, FIG 104, NO FAULTS NOTED EICAS MSG CLEARED.Aug 11, 2016 · N649GT · Boeing 767375 · Pneumatic Indicating SystemSDR UIEA2016080900676Controller · malfunctionedZONE TEMP CONTROLLER UNABLE TO MAINTAIN TEMP FLIGHT CREW MODULATION TRIM AIR TO MAINTAIN TEMP. PERFORMED TASK 21-51-14-705-075, PACK TEMP CONTROLLER BITE FOUND LT TSMP COND VALVE FAULT, TESTED GOOD. BITE TEST ZONE TEMP CONTROLLER. AUX ZONE TEMP CONTROLLER Aug 9, 2016 · N649GT · Boeing 767375 · Cabin Temperature Control SystemSDR UIEA2016080800672Compensator · inoperativeCENTER FUEL QTY INOPERATIVE. REPLACED COMPENSATOR ASSY FOR CENTER MAIN TANK IAW AMM 28-41-02-001-001.Aug 8, 2016 · N649GT · Boeing 767375 · Fuel Quantity IndicatorSDR UIEA2016080400667Connector · looseFWD EICAS MESSAGE FOR RT ENGINE FIRE LOOP 1 AND 2. PERFORMED TROUBLESHOOTING IAW FIM 26-11 FT 804, FOUND HI & RES C PIN. FOUND 1 & 2 LOWER LOOP CONNECTOR LOOSE. SECURED IAW AMM 26-11-02 TEST GOOD & IAW AMM 26-11-00.Aug 4, 2016 · N649GT · Boeing 767375 · Fire Protection System WiringSDR UIEA2016072900644Warning System · false activationLT PACK TEMP CAUTION MESSAGE AND 451646 MT/S IAW AMM 21-51-00 RESET FAULT NO DEFECTS NOTED.Jul 29, 2016 · N649GT · Boeing 767375 · Cabin Cooling SystemSDR UIEA2016072800643Circuit Card · malfunctionedEICAS STATUS MESSAGE FOR RT ENGINE FIRE LOOP NR 2. REPLACED NR 2 LOOP PRINTED CIRCUIT CARD FOR RT ENG IAW AMM 26-11-02.Jul 28, 2016 · N649GT · Boeing 767375 · Smoke DetectionSDR UIEA2016072500624Unknown · malfunctionedEICAS LT PACK TEMP INTERMITTENT DURING CRUISE. T/S IAW FIM 21-51, FT 844 BITE PROCEDURES, SYS CHECK GOOD.Jul 25, 2016 · N649GT · Boeing 767375 · Cabin Cooling SystemSDR UIEA2016072500626Warning Message · false activationLT PACK TEMP EICAS MSG RECEIVED AT CRUISE. PERFORMED CHECKLIST, CLEARED EICAS MSG. PERFORMED BITE TEST IAW AMM 21-51-00-705, NO DEFECTS NOTED.Jul 25, 2016 · N649GT · Boeing 767375 · Cabin Cooling SystemSDR UIEA2016072600631Warning Message · false activationFWD EQUIPMENT OVERHEAT EICAS MESSAGE RECEIVED DURING CLIMB. CHECKLIST PERFORMED, EICAS MESSAGE CLEARED IAW CHECKLIST T/S IAW FIM 21-58-F/T 912, NO DEFECTS NOTED.Jul 25, 2016 · N649GT · Boeing 767375 · Overheat DetectionSDR UIEA2016072400623Fire Detector · faultyRT ENGINE FIRE LOOP 2 EICAS MSG. TRANSFER TO MDDR 68667 IAW MEL 26-11-01-01, CAT C, DUE DATE 03-AUG 2016, PLACARD INSTALLED. REMOVED AND REPLACED NR 2 ENG UPPER AFT FIRE DETECTOR AS PER AMM 26-10-02 OPS CHECK NORMAL, MDDR CLEARED.Jul 24, 2016 · N649GT · Boeing 767375 · Fire DetectionSDR UIEA2016072200620Warning System · false activation2 STARTS ON APU BOTH RESULTED IN APU FAULT, CLEARED, APU START NORMAL. PERFORMED APU BITE PROCEDURES IAW FIM 49-11, FT 958 FAULTS CLEARED. APU START NORMAL.Jul 22, 2016 · N649GT · Boeing 767375 · APU Indicating SystemSDR UIEA2016071900595Cooling Fan · failedFWD EQUIPMENT SUPPLY FAN 1 EICAS MESSAGE. CIRCUIT BREAKER WILL NOT RESET. REMOVED AND REPLACED COOLING SUPPLY FAN IAW AMM 21-58-06. OPS CHECK GOOD.Jul 19, 2016 · N649GT · Boeing 767375 · Air Distribution FanSDR UIEA2016072000602Controller · inoperativeFWD AND AFT TEMP TEMP CONTROLLERS INOPERATIVE. PERFORMED ZONE TEMP CONTROLLER BITE IAW AMM 21-61, FAULT TREE 803, NO FAULTS NOTED. SYS CHECK OK.Jul 18, 2016 · N649GT · Boeing 767375 · Cabin Temperature ControllerSDR UIEA2016072100610Controller · malfunctionedCREW REPORTED INTERMITTENT LT PACK TEMP EICAS MESSAGE. REMOVED AND REPLACED THE LT PACK TEMP CONTROLLER ASSY SYS BITE TEST OK IAW AMM 21-51-14/404.Jul 17, 2016 · N649GT · Boeing 767375 · Cabin Cooling SystemSDR UIEA2016071500586Fire Loop · faultyRIGHT ENGINE FIRE LP 2 EICAS MESSAGE TRANSFERRED TO MDDR 68398 IAW 26-11-01-01, CAT C. REMOVED AND REPLACED UPPER AFT LOOP IAW AMM 26-11-02. OPS CK OK. MDDR 68398 CLEARED.Jul 15, 2016 · N649GT · Boeing 767375 · Fire DetectionSDR UIEA2016071400582Detector · faultyEICAS MSG FWD CARGO DET 1, TRANSFERRED TO MDDR 68348 IAW MEL 26-16-01-01-01, CAT C. REMOVED AND REPLACED FWD CARGO NR 1 DETECTOR IAW AMM 26-16-01. OPS CHECK OK.Jul 13, 2016 · N649GT · Boeing 767375 · Detection SystemSDR UIEA2016071400581Warning Message · false activationLEFT PACK TEMP EICAS MESSAGE. PERFORMED PACK TEMPERATURE CONTROLLER BITE TEST. BITE TESTED OK, NO MESSAGE FOUND IAW AMM 21-61-12-715.Jul 13, 2016 · N649GT · Boeing 767375 · Cabin Cooling SystemSDR UIEA2016071100574Hose · leakingLEAKING RUBBER HOSE IN LEFT PACK BAY DISCOVERED DURING WALKAROUND. SECURED THE LINE AND RECONNECTED IAW AMM 21-51-03, NO LEAKS NOTED.Jul 10, 2016 · N649GT · Boeing 767375 · Pneumatic Distribution SystemSDR UIEA2016070700567Circuit Card · failedNR 2 ENGINE FIRE LOOP 2 MESSAGE EICAS. REPLACED NR 2 ENGINE LOOP 2 FIRE DETECTION PRINTED CIRCUIT CARD IAW AMM 26-10-01. CHECKED OK.Jul 6, 2016 · N649GT · Boeing 767375 · Fire Protection System WiringSDR UIEA2016070700565Circuit Card · failedWHEN LEFT PACK TURNED OFF, NO PACK OFF LIGHT AND NO L PACK OFF EICAS MESSAGE. REPLACED LEFT PACK FLOW CONTROL PRINTED CIRCUIT CARD IAW AMM 21-51-09. OPS CHECKED GOOD.Jul 5, 2016 · N649GT · Boeing 767375 · Air Conditioning System WiringSDR UIEA2016070700566Shutoff Valve · malfunctionedSTATUS MESSAGE RT IDG VALVE. REPLACED IDG AIR OIL HEAT EXCHANGER AIR SHUTOFF VALVE IAW AMM 24 11-07 OPS AND LEAK CHECKED OK.Jul 4, 2016 · N649GT · Boeing 767375 · AC Generator-AlternatorSDR UIEA2016070400562Fluid · lowRIGHT IDG VALVE STATUS TROUBLESHOOTING, FIM 24-20, FT 802. NO DEFECT NOTED ADDED ONE PINT, OIL TO IDG OK FOR SERVICES.Jul 4, 2016 · N649GT · Boeing 767375 · AC Generator-AlternatorSDR UIEA2016070700570Circuit Card · failedLT ENGINE SPEED CARD EICAS MESSAGE DISPLAYED. REPLACED LT ENG N2 SPEED CARD IAW AMM 73-21-54. OPS CHECKED GOOD.Jul 3, 2016 · N649GT · Boeing 767375 · Engine Indicating System WiringSDR UIEA2016070200558Switch · defectiveDURING ENGINE START RT ENGINE VALVE LIGHT FAILED TO CYCLE LAMP TEST CONFIRMED THAT THE LIGHT WAS FUNCTIONING PROPERLY. PLACED ON DEFERRAL. REPLACED SW LIGHT IAW 33-13-00. OPS CK OK IAW 28-22-01. THIS CLEARS MEL.Jul 1, 2016 · N649GT · Boeing 767375 · Fuel Indicating SystemSDR UIEA2016062200453Status Message · false activationSTATUS MESSAGE, FORWARD CARGO DETECTOR 1 PERFORMED LOWER CARGO SMOKE DETECTION SYS BITE IAW FIM 26-16, FT 806. SYS CHECKS OK, EICAS MESSAGE CLEARED.Jun 23, 2016 · N649GT · Boeing 767375 · Smoke DetectionSDR UIEA2016062300455Warning System · activatedFLIGHT DECK TEMP EICAS, IN FLIGHT DECK TEMP, INOPERATIVE LIGHT ILLUMINATED MANUAL CONTROL, WORKS OK. PERFORMED ZONE TEMP CONTROL BITE PROCEDURE IAW FIM 21-61.Jun 23, 2016 · N649GT · Boeing 767375 · Cabin Temperature IndicatorSDR UIEA2016062300457Control Valve · faultyINTERMITTENT LT PACK OFF, EICAS MESSAGE DURING DESCENT. TRANSFERRED TO MDDT 67731 IAW MEL 21-51-03-01, CAT C. REMOVED AND REPLACED LEFT ACM TEMP CONTROL VALVE AS PER AMM 21-51-12. OPS CHECK NORMAL.Jun 22, 2016 · N649GT · Boeing 767375 · Cabin Cooling SystemSDR UIEA2016062300458Status Message · false activationFUEL QTY TOTALIZER INOPERATIVE STATUS MESSAGE. QTY BITE IAW FIM 28-41 F/T 852, NO FAULTS AT THIS TIME.Jun 22, 2016 · N649GT · Boeing 767375 · Fuel Quantity Indicator
Back to N649GT