N649GT
Service difficulty reports · 574
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N649GT' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N649GT' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2017080901447Warning Message · false activationSTATUS MESSAGE FOR RT IDG VALVE. INSPECTED THE RT IDG IAW AMM 24-11-01, AND 24-11-04, NO FAULTS NOTED. MESSAGE CLEARED.SDR UIEA2017080901441Warning Light · false activationEICAS L BLEED DUCT LEAK. INSPECTED THE LT BLEED DUCTS IAW AMM 36-00-00, NO LEAKS OR FAULTS NOTED.SDR UIEA2017080201411Shutoff Valve · failedDURING DEPARTURE, STATUS MESSAGE FOR HYD GEN VALVE. REMOVED AND REPLACED THE HYD MOTOR GEN SHUTOFF VALVE IAW MM 24-25-03. TESTED GOOD.SDR UIEA2017073101394Ecu · malfunctionedAPU FAULT. APU WOULD NOT START AFTER LANDING. REMOVED AND REPLACED APU ECU APU OPS CHECKED OK IAW AMM 49-61-05.SDR UIEA2017073001386Warning Message · false activationSTATUS MESSAGE FOR THE LT IDG VALVE. PERFORMED BUSS POWER CONTROL UNIT BIT IAW FIM 24-20 FT 802. NO FAULTS NOTED. RESET UNIT, EICAS MESSAGE CLEARED.SDR UIEA2017073001387Warning Light · false activationAFTER TAKEOFF, THE FWD EQUIPMENT OVERHEAT ILLUMINATED. ACCOMPLISHED QRH NON NORMAL PROCEDURE. EICAS MESSAGE OUT AFTER PROCEDURE COMPLETE. PERFORMED FIM 21-58 FT 815, NO DEFECTS NOTED. SYS OPS NORMAL.SDR UIEA2017072801348Ecu · malfunctionedAPU RELIABILITY COLD START FAILED ON 3 ATTEMPTS DURING FLT. PERFORMED BITE PROCEDURE ON APU ECU IAW FIM 49-11. RESET APU ECU APU START NORMAL.SDR UIEA2017072601316Priority Valve · failedCREW REPORTED A RIGHT ENGINE PRV EICAS MESSAGE IN FLT. PERFORMED FIM 36-10, FT 847. REMOVED AND REPLACED THE RIGHT ENGINE PRV IAW AMM 36-11-18/401. LEAK CHECKED GOOD. PERFORMED AIR SUPPLY BITE MODUAL TEST IAW FIM 36-20-00/101. ALL FAULTS CLEARED. NO ADDITIOSDR UIEA2017072801347Warning Message · false activationAFTER LANDING, APU FAULT EICAS MESSAGE. PERFORMED QRH NON NORMAL PROCEDURE, WITH SAME RESULT. PERFORMED BITE ON APU ECU IAW FIM 49-11, TASK 958. NO FAULTS NOTED. RESET APU ECU. APU STARTED NORMALLY.SDR UIEA2017072701325Filter · not reportedRIGHT IDG VALVE STATUS MSG. REMOVED AND REPLACED IDG AIR SHUTOFF VALVE PNEUMATIC FILTER AS PER AMM 24-11-07 OPS TEST NORMAL ON ENG RUN UP, STATUS MSG CLEARED.SDR UIEA2017072701324Ecu · malfunctionedINFO ONLY APU COLD SOAK START UNSUCCESSFUL APU FAULT MSG ON THREE ATTEMPTS FL 380 SAT -45. PERFORMED BITE PROCEDURE ON APU ECU IAW FIM 49-11 FT 958 NO FAULTS NOTED, RESET APU ECU, APU START NORMAL.SDR UIEA2017072701323Warning Message · false activationEQUIPMENT COOLING OVERHEAT EICAS MESSAGE DURING CLIMB . COMPLIED WITH QRH, MESSAGE EXTINGUISHED AFTER OVER RIDE SELECTION FOR 30 MIN , MESSAGE REMAINED . EXTINGUISHED DURING THE REMAINDER OF THE FLIGHT. PERFORMED FIM 21-58 FT 815, NO DEFECTS NOTED, SYSTEM OPSSDR UIEA2017072501307Shutoff Valve · malfunctionedSIGNIFICANT DUCT PRESSURE DIFFERENCE BETWEEN LEFT AND RIGHT. AT 91% N1 DURING CRUISE FLT. LEFT DUCT AT 37 AND RIGHT 9. PERFORMED FIM 36-10 FT 838, REMOVED AND REPLACED PRSOV IAW AMM 36-11-09/501, AND PRVC IAW AMM 36-11-18/501, BOTH OPS TEST NORMAL ON ENGINSDR UIEA2017072501298Filter · dirtyRIGHT ENGINE BLEED OFF EICAS MESSAGE. PERFORMED FIM 36-10 F/T 838, CLEANED PRSOV FILTERS IAW AMM 36-11-09-002 PRSOV OPS CHECKED TEST NORMAL.ON ENGINE RUN UP.SDR UIEA2017072701322Warning Message · false activationEQUIPMENT COOLING OVERHEAT DURING CLIMB. COMPLIED WITH QRH & SELECTED OVER RIDE, MESSAGE WENT OUT, PERFORMED FIM 21-58 F/T 815, NO DEFECTS NOTED.SDR UIEA2017072701321Ecu · malfunctionedAPU RELIABILITY, COLD START COMPLIED WITH. UNSUCCESFUL AFTER 3 ATTEMPTS. APU FAULTS ALL 3 ATTEMPTS. PERFORMED BITE PROCEDURE ON APU ECU IAW FIM 49-11F/T 958. NO FAULTS NOTED. RESET APU ECU, STARTED NORMAL.SDR UIEA2017072501304Apu · malfunctionedAPU FAILED TO START AFTER LANDING. PERFORMED A BITE ON APU ECU IAW FIM 49-11 FT 958. NO FAULTS NOTED. RESET APU ECU, APU START NORMAL.SDR UIEA2017072401283Detector · failedEICAS MESSAGE FWD DETECTOR FAN DISPLA. REMOVED AND REPLACED FORWARD DETECTOR 1 IAW AMM 26-16-02 OPS CHECK NORMAL</P>)SDR UIEA2017072401284Duct · damagedAPU AIR SURGE RUBBER BLEED DUCT HAS A HOLE. REPLACED APU SURGE BLEED RUBBER DUCT IAW AMM 49-10-00 OPS CHECKED OK, NO LEAKS.SDR UIEA2017072401285Lamp · inoperativeL4 CABIN ENTRY EXTERIOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE LAMP IAW AMM 33-51-06.SDR UIEA2017072301276Blade · damagedON POST FLIGHT INSPECTION. FOUND A SMALL DENT ON FAN BLADE, LEFT ENGINE. PERFORMED INSPECTION OF LEFT ENGINE FAN BLADES, FOUND DENT ON 9 BLADE IN THE B AREA TO BE WITHIN LIMITS ( 0.035 INCH IN DEPTH) PERFORMED A REPAIR IAW IAW AMM 72-31-02-226-012.SDR UIEA2017072201270Warning Message · false activationRIGHT IDG VALVE STATUS MESSAGE. PERFORMED BITE TEST ON BUSS POWER CONTROL UNIT. NO FAULTS NOTED. RIGHT IDG VALVE STATUS MESSAGE CLEARED IAW FIM 24-20 FT 802.SDR UIEA2017071801237Warning Light · false activationFWD EQUIPMENT OVERHEAT EICAS ON TAKEOFF RAN QRH CHECKLIST AFTER 35 MINUTES LIGHT EXTINGUISHED, GROUND TEMP 47C EQUIPMENT COOLING SYS OPS TESTED NORMAL IAW AMM 21-58-00/705-120-006.SDR UIEA2017071801236Control Valve · malfunctionedLEFT PACK WILL NOT TURN OFF. REMOVED, CLEANED AND INSPECTED D 748 FROM THE LT PACK FLOW CONTROL VALVE. REINSTALLED OPS TESTED GOOD IAW FIM 21-51 FT 810.SDR UIEA2017071701228Ecu · failedAPU FAILED TO START. FOUND APU ECU FAILED. REMOVED AND REPLACED ECU IAW AMM 49-61-05-1401.SDR UIEA2017070301108Control Panel · brokenR4 FA EVAC PANEL BROKEN. REMOVED AND REPLACED EVAC CONTROL PANEL IAW AMM 25-63-01, OPS CHECKED SATISFACTORY.SDR UIEA2017062701067Actuator · malfunctionedAPU DOOR ACTUATOR CIRCUIT BREAKER FOUND OPEN. REMOVED AND REPLACED APU DOOR ACTUATOR IAW AMM 49-15-06, OPS CHECKED GOOD.SDR UIEA2017062601063Circuit Breaker · trippedAPU INOPERATIVE, FOUND APU DOOR CIRCUIT BREAKER OPEN, RESET THE CIRCUIT BREAKER IAW AMM 20-60-01. PERFORMED APU BITE TEST IAW AMM 49-61-05, NO FAULTS FOUND. OPS CHECKED GOOD IAW AMM 49-11-01.SDR UIEA2017051600802Indication Sys · faultedRIGHT OIL TEMPERATURE GAUGE INOPERATIVE. PERFORMED FIM 79-34, FAULT TREE 815, PIMU BITE, TEMP SENSOR FAULTED, IAW PIMU TABLE 71-01-00/201. PERFORMED TASK 71-01-00-810 A4S-H01. NO DEFECTS NOTED. RIGHT OIL TEMPERATURE INDICATION NORMAL.SDR UIEA2017051500786Nut · seizedNR 2 ENGINE, NR 2 THERMOCOUPLE PROBE, FOUND NUT ON TERMINAL END SEIZED. REMOVED AND REPLACED THE THERMOCOUPLE PROBE IAW AMM 77-21-01.SDR UIEA2017051100775Blower · defectiveCARGO DET AIR STA MESSAGE ON DURING FLIGHT. REMOVED AND REPLACED FWD NR 2 SMOKE DETECTOR BLOWER, OPS TEST GOOD. EICAS STAT MESSAGE CLEARED IAW AMM 26-16-02.SDR UIEA2017050500713Fuel Control · faultedLT ENG CONTROL FAULT. REPLACE HYD FUEL CONTROL UNIT PER COMPANY REQUEST. REMOVED AND REPLACED HYDRO MECHANICAL FUEL CONTROL UNIT AND LEFT ENG EEC PART 1519M89P29 SERIAL LMDD7973 IAW AMM 73-21-14 AND SUBTASK 73-21-15-714-020-H00. PERFORMED TEST AND LEAK CHECK OSDR UIEA2017050300693Eec · malfunctionedLEFT ENGINE CONTROL STATUS MESSAGE. POWERED LEFT EEC, PERFORMED BITE TEST OF LEFT PIMU, FAV SENS DISAGREE FAULT PRESET, REMOVED POWER FROM L EEC, INSPECTED SECURITY OF CONNECTORS OF EWIS TO L ECC , SUPPLIED POWER TO LEFT EEC, PERFORMED VERIFY ERASE OF FAULT,SDR UIEA2017050400697Warning System · false activationLEFT ENGINE CONTROL EICAS MSG AFTER LANDING DURING TAXI IN. MESSAGE WAS NOT A LATCHED FAULT REF AMM 71-00-00-725-268-H03, EEC STATIC TEST PERFORMED. CHECKS/TEST GOOD. NO FAULT PRESENT.SDR UIEA2017050300692Warning System · false activationLEFT ENGINE CONTROL EICAS MSG AFTER LANDING DURING TAXI IN. MESSAGE WAS NOT LATCHED FAULT REF AMM 71-00-00-726-268-H03 FFC STATIC TEST PERFORMED CHECKS/TEST NO FAULTS PRESENT.SDR UIEA2017042400627Window · failedRT SIDE WINDOW EICAS DURING CRUISE FLT. R & R WINDOW ASSEMBLY AND RIGGED IAW 56-11-02 OPS CHECKED GOOD.SDR UIEA2017042400626Warning Message · false activationRT WINDOW HEAT EICAS, PERFORMED LEFT FWD OR RIGHT WINDOW ANTI ICING BITE PROCEDURE IAW FIM TASK 30-41-00-815 AND RIGHT FWD OR LEFT SIDE WINDOW ANTI ICING PROCEDURE 30-41-00-815. BITE TEST GOOD. NO FAULTS NOTED.SDR UIEA2017042000611Warning Message · false activationDURING DESCENT AT 5000FT, RT WINDOW EICAS. PERFORMED TROUBLESHOOTING IAW FIM 30-41 TR 803, BITE TEST, SYSTEM OK, NO FAULTS PRESENT.SDR UIEA2017041400580Fan · malfunctionedSTATUS MESSAGE FOR THE AFT EQUIPMENT EXHAUST FAN 1. REMOVED AND REPLACED THE EXHAUST FAN IAW AMM 21-58-00. OP CHECKED GOOD.SDR UIEA2017040700527Selector Switch · stuckWEATHER RADAR FAILED MESSAGE, FOUND THE WEATHER RADAR PANEL SELECTOR SWITCH STUCK , CLEANED AND OPS CHECKED GOOD.SDR UIEA2017040700526Igniter · failedAPU COLD SOAK START ATTEMPT UNSUCCESSFUL TWICE. ATTEMPTED APU COLD SOAK START AFTER TWO HOURS AT FL 410. APU SHUT DOWN TWICE AFTER REACHING APPROXIMATELY 750 EGT. FAULT LIGHT ILLUMINATED. REMOVED AND REPLACED THE APU IGNITER PLUG, OPS CHECKED OK IAW AMM 4SDR UIEA2017031600354Warning Message · false activationRT STARTER CUTOUT ON FINAL APPROACH WITH RT ENG STARTER MESSAGE LATER ON GROUND. REMOVED, CLEANED, AND INSPECTED THE CONNECTOR PLUGS AT START VALVE. PERFORMED START VALVE TEST IAW AMM 71-0000-995-229-403. OPS TESTED NORMAL.SDR UIEA2017030200252Blades · lack of lubeLEFT ENGINE FAN VIBRATION INDICATES 3.8 - 4.2 WITH STEADY CLIMB POWER. IAW MAINTENANCE ENGINEERING, COMPLETED FAN BLADE LUBRICATION IAW AMM 72-31-00. REMOVED FAN BLADES AND LUBRICATED. REINSTALLED. OPERATIONAL CHECKS AND VIBRATION OK ON ENGINE RUNS IAW MM 72-SDR UIEA2017030300297Blade · lack of lubeLEFT ENGINE FAN VIBRATION INDICATES 3.8-4.2 WITH STEADY CLIMB POWER. COMPLETED FAN BLADE LUBRICATION IAW AMM 72-31-00. REMOVED FAN BLADES LUBRICATED REINSTALLED .SDR UIEA2017022200233Shutoff Valve · leakingDURING POST FLIGHT, DISCOVERED A FUEL LEAK FROM THE LT MAIN WHEEL WELL. FOUND APU FUEL SHUTOFF VALVE LEAKING.SDR UIEA2017021600184Sensor · failedRT ENGINE OIL TEMP INDICATION BLANKS OUT. REMOVED AND REPLACED RT ENGINE OIL TEMP SENSOR IAW AMM 79-34-01. LEAK AND OPS CHECK OK.SDR UIEA2017020200144Sensor · malfunctionedLEFT ENGINE OIL TEMP FLUCTUATES IN FLIGHT, READ DOWN TO 32*C WHILE RT SIDE READS 80*C, THEN INDICATION WENT BLANK. T/S IAW FIM 79-34 FT 807. REMOVED AND REPLACED LEFT ENGINGE OIL TEMP SENSOR IAW AMM 79-34-01 OPS AND LEAK CK GOOD.SDR UIEA2017012900119Valve · failedLEFT ENGINE ANTI-ICE VALVE IS EITHER FAILING OR STICKING . VALVE LIGHT STAYS ON UNTIL POWER IS PUSHED UP ON GROUND AND IN FLIGHT. THE LEFT ANTI-ICE VALVE WAS REPLACED IAW AMM 30-21-03. OPS & LEAK CHECKED OK.SDR UIEA2016122701057Oil System · false indicationRIGHT ENGINE OIL FLUCTUATES BETWEEN 100-20 THEN BLANKED. REMOVED CLEANED AND INSPECTED RT ENG OIL TEMP SENSOR IAW AMM 79-34-01 OPS TEST NORMAL ON ENG RUN UP IAW AMM 71-00-00.SDR UIEA2016122401053Wire · damagedRIGHT ENGINE ANTI-ICE EICAS MESSAGE. PERFORMED TROUBLESHOOTING IAW FIM 30-21 FT 806 , AND WDM 30-21-11-1. FOUND THREE BROKEN WIRES. PERFORMED REPAIR AND PINNING OF ALL THREE WIRES IAW SWPM 20-10-13. PERFORMED OPS CHECK OF ANTI-ICE AND RT THRUST REVERSER CH
Back to N649GT