N649UA
Service difficulty reports · 272
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N649UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N649UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013061704177Selector Panel · faultedNR 2 AUDIO SELECTOR PANEL VOLUME CONTROL DEFECTIVE. REMOVED AND REPLACED FIRST OBSERVER`S AUDIO SELECTOR PANEL.SDR UALA2013061404111Light · inoperativeEMERGENCY LIGHT INOPERATIVE AT AFT RT INBD LAVATORY. REPLACED EMERGENCY LIGHT. SYS OK.SDR UALA2013061404110Battery · inoperativeEMERGENCY LIGHTS INOPERATIVE SEAT ROWS 24 LT THRU 33 LT. REPLACED BATTERY AND CHARGER M99082 IAW MM, SEATS OPS CHECKED NORMAL.SDR UALA2013061404109Lamp · inoperativeEMERGENCY LIGHT INOPERATIVE AT R1 DOOR. REPLACED LAMP, OPS NORMAL.SDR UALA2013060503897Fan · failedFWD EQUIP EXHAUST FAN STATUS MESSAGE. REPLACED FORWARD EXHAUST FAN.SDR UALA2013050703211Actuator · malfunctionedDURING CRUISE, NO RT INBD AILERON INDICATION MOVEMENT. DISCONNECTED AUTOPILOT AND ACCOMPLISHED SERIES OF TURNS. CONFIRMED RT INBD AILERON WOULD NOT MOVE DOWN DURING TURNS. AILERON ALSO NOT FAIRED IN NEUTRAL POSITION AND REQUIRED LT AILERON TRIM TO MAINTAIN SDR UALA2013041502595Charger · inoperativeEMERGENCY LIGHTS INOPERATIVE AT SEATS 1AB TO 9AB. REPLACED EMERGENCY LIGHT CHARGER PER AMM.SDR UALA2013041202523Battery · inoperativeR2 DOOR EMERGENCY LIGHT BATTERY INOPERATIVE. BATTERY REPLACED AND OPS TESTED NORMAL IAW MM.SDR UALA2013030801397Battery Pack · inoperativeEMERGENCY LIGHTS ARE INOPERATIVE ON SEATS FROM 1ST CLASS THROUGH BUSINESS CLASS ON LEFT SIDE. REPLACED BATTERY. EMERGENCY LIGHT CHECKED OKAY.SDR UALA2013030801396Battery · dischargedEMERGENCY LIGHTS ARE INOP ON SEATS FROM 24 AB TO 33AB. BATTERY LOCATED BEHIND DADO PANEL AT SEAT 29A. REPLACED BATTERY CHARGER UNIT AND BATTERY AND TEST PER MM, CHECKS NORMAL.SDR UALA2013030601335Light · inoperativeEMERGENCY LIGHTS ARE INOP ON SEATS FROM 24 AB TO 33AB.SDR UALA2013030601334Connector · unsecureEMERGENCY LIGHT AT SEAT 19JK IS INOP. SECURED CONNECTOR FOR EMERGENCY SEAT LAMP, OPS CHECK NORMAL.SDR UALA2013022501127Control Panel · faultyUNABLE TO TRANSMIT OUT ON LT HF RADIO. NO RECEPTION FROM LT HF EITHER. ESTABLISHED HF COMMUNICATION AND SELCALL CHEC. OPS NORMAL.SDR UALA2013012500460Connector · dirtyCENTER BLEED ISOLATION WILL NOT OPEN. CLEANED CONNECTOR ON CENTER ISOLATION VALVE, OPS CHECKED OKAY.SDR UALA2013012100369Battery Pack · dischargedEMERGENCY LIGHTS INOPERATIVE ON SEATS 1A TO 2A AND 6AB THRU 14AB. EMERGENCY LIGHT BECAME VERY DIM. REPLACED BATTERY AT ROW 8A.SDR UALA2013010300031Nut · crackedNR 4 FWD MAIN WHEEL HAS 1 EA TIE BOLT NUT CRACKED AND BOLT IS LOOSE IN WHEEL HALVES. REPLACED NR 4 FWD WHEEL TIRE ASSY PER MM.SDR UALA2012102606161Fseu · faultyFLAP O-SPEED WARNING AT CRUISE AT 320 370 AND CLIMBING THRU 32.7.5 TIMES. M545 FAULT REPLACED FSCU PER AMM.SDR UALA2012101805964Timer · out of adjustMID RIGHT LAV SINK WATER WON'T SHUTOFF. WATER SHUTOFF VALVE FAILED. REPLACED WATER SHUTOFF VALVE TO ENABLE DEFFERAL. REQUIRES NEW FAUCET VALVE OR TIMER, NO TIME TO TROUBLESHOOT. PER MEL DEACTIVATED WATER HEATER AND BOARDED HAND SANITIZER. ADJUSTED HYDRAULSDR UALA2012092905527Steering Unit · malfunctionedLOW GAIN ON SATCOM WITH BITE FAIL & T-P BSU FAULT. CANNOT PLACE CALL BUT SAT WORKS FOR ACARS. REPLACED PORT BEAM STEERING UNIT PER MM 23-25-17 PER MM 23-25-17 AND ACCOMPLISHED INSTALLATION TEST PER MM 23-25-00, OPS CHECKS GOOD.SDR UALA2012082804832Feeder Cable · damagedAPU INOP ELECTRICAL. UNABLE TO LOAD GENERATOR. REFER TO MM. APU FIELD OFF LIGHT. DEFERRED PER TOMC AND SEE CF831 FOR PARTS INFO. REPLACED APU GEN FEEDER HARNESS, REFER TO CF0831.SDR UALA2012082304730Feeder Cable · damagedFOUND APU FEEDER CABLE T1 BURNT ON APU GENERATOR NEED TO REPLACE APU GENERATOR DUE TO BURNT FEEDER HARNESS LEADS. REPLACED APU GENERATOR IN ACCORDANCE WITH MM.SDR UALA2012080704239Actuator · brokenLEFT HYD SYS PRESSURE EICAS, RTFL. FOUND NR 6 SPOILER ACTUATOR HOUSING BROKEN. REPLACED ACTUATOR AND LT CASE RET FILTERS. SERVICED LT HYD FLUID. OPERATIONAL CHECKED OK.SDR UALA2012071803894Windshield · delaminatedDELAMINATED WINDSHIELD 1L IN UPPER RIGHT CORNER. REPLACED WINDSHIELD PER AMM.SDR UALA2012071803893Windshield · delaminatedDELAMINATED WINDSHIELD 1R IN UPPER RIGHT CORNER. REPLACED 1R WINDSHIELD PER AMM.SDR UALA2012071103702Oxygen Mask · unlatchedOXYGEN PANEL IN ECONOMY NEEDS TO BE RESTOWED. REPACKED O2 MASK PER AMM. ALL OPS CHECK GOOD.SDR UALA2012061503292Control Valve · faultyLEFT PACK INOP WILL NOT RESET. REPLACED LEFT FLOW CONTROL CARD IN P50 CARDFILE PER MM, ALSO LEFT FLOW CONTROL VALVE PER MM, PACK OPS NORMAL.SDR UALA2012060103051Control Valve · stuckFOUND LT PACK FLOW CONTROL VALVE STUCK CLOSED. REPLACED LEFT FLOW CONTROL VALVE, OPS CHECKED GOOD ON GROUND.SDR UALA2012060103050Valve · faulty'LT PACK INOPERATIVE' ILLUMINATED ON EICAS. OPERATED NORMAL AFTER 'STANDBY' SELECTED. REPLACED LOW LIMIT VALVE.SDR UALA2012051602789Battery · inoperativeEMERGENCY LIGHT IN COCKPIT IS INOPERATIVE. REMOVED AND REPLACED BATTERIES IAW AMM 33-51-01. OPS CHECKED GOOD.SDR UALA2012051102740Lamp · inoperativeEMERGENCY EXIT LIGHT ABOVE SEAT 36AB IS INOPERATIVE. REPLACED LAMP AT SEAT 36AB. OPS CHECKED GOOD.SDR UALA2012020700740Actuator · intermittentRUDDER TRIM INTERMITTENT, FLIGHT DIVERTED. REPLACED RUDDER TRIM ACTUATOR PER MM. REPLACED RUDDER TRIM CONTROL MODULE PER MM. OPS CHECKS GOOD.SDR UALA2012013000606Monitor · faultyRT HYD SYSTEM QTY IS 0.02; R HYD QTY EICAS MSG DISPLAYED. SAMC TEXT: WITH RT QTY LOW LIGHT ALSO. TOMC MAINT TEXT: PER CREW, PUMP LOW PRESS LIGHTS DID NOT ILLUMINATE PRESSURE NORMAL. NO SIGNS OF EXTERNAL LEAKAGE. REPLACED HYD QTY MONITOR UNIT PER MM, QTY SYSDR UALA2012012700569Selector Panel · faultyRT HF TRANSMISSIONS ARE INOP, WEAK, GARBLED, INTERMITTENT AT (1=CAPT,2=F-O,3=F-OB) STATION. OTHER STATIONS NORMAL. TRIED NEW TRANSCEIVER, NO HELP. REPLACED O/B AUDIO SEL PNL. OP CKS OK.SDR UALA2011121906959Relay · faultyDUE TO REPORT OF EXTERNAL POWER CONTACTOR NOT OPENING AFTER EXTERNAL POWER WAS DE-SELECTED AND EXTERNAL POWER WAS REMOVED REPLACED EXTERNAL POWER CONTACTOR K114 PER MM. RPL'D EXTERNAL PWR CONTACTOR, CKS OKAY PER MM TEST. RAN ENGINES TO DUPLICATE DF680, PWR WSDR UALA2011121606923Transceiver · defectiveHF TRANSMISSION & RECEPTION ARE INOP, WEAK, GARBLED INTERMITTENT, ETC. AT ALL CREW STNS. (1 = L HF, 2 = R HF) CREW COMMENTS: UNABLE TO XMIT. CAN RECEIVE OK. LONG SIDE TONE WHEN TUNING. COMPLIED WITH MEL. REMOVED AND REPLACED RIGHT HF TRANSCEIVER.SDR UALA2011121206789Pressure Switch · malfunctionedCENTER HYDRAULIC SYSTEM LOW PRESSURE LIGHT ILLUMINATED WITH EICAS AND ADP LOW PRESSURE LIGHT. REPLACED CENTER HYD SYSTEM LOW PRESSURE SWITCH PER MM, OPS NORMAL.SDR UALA2011112906555Fitting · leakingHYD LEAK ON NR 2 ENG FOUND DURING PREDEPARTURE WALKAROUND, FOUND LEAK FROM LT TOP THRUST REVERSER ACTUATOR. SECURED FITTING FOR INTERCONNECT CABLE HOUSING FOR LEFT TOP THRUST REVERSER ACTUATOR. NO LEAKS NOTED.SDR UALA2011112106347Rod · wornNR 2 ENGINE PYLON STRUT PLENUM SUPPORT RODS ARE WORN OUT. REPLACED RODS.SDR UALA2011111806339Fitting · leakingNR 1 ENG HAS HEAVY COAKING AT 12'O'CLOCK. REMOVED 2 EA DRAIN LINES FROM PYLON AND HYD LINE CLUSTER NO BLOCKAGE NOTED. REMOVED PYLON ACCESS PNL 416BR & FOUND NO EVIDENCE OF LEAKAGE. REINSTALLED PNL. REMOVED NR 1 ENG PYLON JUNCTION BOX INSULATION AND COVER FSDR UALA2011112106346Duct · splitRIGHT WING OUTBD DUCT GOING TO ANTI-ICE VALVE ABOVE NR 2 PYLON IS SPLITTING OUTBD OF CLAMP (MKD WITH TAPE). REMOVED DUCT AND SENT TO WELDING SHOP. REPLACED DUCT.SDR UALA2011112106345B-Nut · leakingNR 2 PYLON, EVIDENCE OF HYDRAULIC LEAK, INBD SIDE. FOUND HYD PRESS LINE ABOVE NR 2 PYLON AT BULKHEAD FITTING LEAKING MARKED WITH TAPE. SECURED LOOSE 'B' NUT ON HYDRAULIC LINE. RAN HYDRAULICS AND MOTORED ENGINE, NO LEAKS FOUND.SDR UALA2011112106341Eec · faultyWHILE ACCOMPLISHING PIMU BITE CHECK FOUND NR 2 ENG EEC CH A FAULT CAT 2 MESSAGE EEC CH A TCA SOL W-A FAIL. TROUBLESHOT REF FIM 71 PIMU MESSAGE INDEX PG64K,PG64L, MESSAGE 354-22 & REF WDM 71-51-14. COMPLETED TO ITEM G INDICATES NEED EEC. REF PTT # 6562008 FOSDR UALA2011111706313Light · inoperativeLEFT OVERWING SLIDE EMERGENCY LIGHT AFT OF FLAPS (2ND TO LAST) INOPERATIVE. RELAMPED PER MM, OP CHECKS NORMAL.SDR UALA2011111706312Light · inoperativeEEL LIGHT AT SEATS 35KJ INOPERATIVE. RELAMPED, OP CHECKS NORMAL PER MM.SDR UALA2011111406232Cap · missingMISSING WINDSHIELD HEAT TERMINAL CAP F/O WINDSCREEN. REPLACED CAP.SDR UALA2011110906099Controller · faultyLEFT ENG BLEED OFF EICAS. FOUND FAULTED NR 1 ENG PRVC. REPLACE PRVC. RAN ENG PER JRH. ALL BLEED INDICATIONS NORMAL.SDR UALA2011110405977Control Panel · faultyWX RADAR FAILURE, RTFL. MESSAGE DISPLAYED. FOLLOWED PROCEDURE IN FM, NO HELP. ATTEMPTED CB RESET, FAIL MESSAGE RETURNED. ACP'D SYSTEM CHECK OF THE WX RADAR, NO SCAN SWEEP AND FAILURE MESSAGE FAULTED THE ANTENNA. REPLACED THE DRIVE ASSY & ANTENNA PER MM. SDR UALA2011110205929Wire Harness · damagedSEAT 6B EEPL LIGHT INOP ACCOUNT WIRING DAMAGED. OK TO CONTINUE PER MEL. RDF-P :EEPL HARNESS ASSY PCN 160-0100 AND EXIT LIGHT P/N BR9644-1. -RDF-P :VERIFIED PART# NEED 566-1162 & POWER AT CONNECTOR. REPLACED LIGHT ASSY FOR EEPL LIGHT OPS CHECK OK.SDR UALA2011101005475Pca · out of adjustRT ELEVATOR FAILED PCA BELLCRANK CHECK. FOUND RT ELEVATOR EXCEEDS 1 INCH LIMITS BETWEEN LEFT & CENTER HYD SOURCES. INSPECTED AND ADJUSTED ELEVATOR PCA IAW AMM. ELEVATOR CHECKED GOOD.SDR UALA2011093005309Heat Shield · cokedNR 2 PYLON, HEAVY COKING AROUND INBD LOWER PYLON HEAT SHIELD AREA. REMOVED CLOG FROM AFT PYLON DRAIN TUBE OUTLET.
Back to N649UA