N649UA
Service difficulty reports · 272
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N649UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N649UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011082904636Control Valve · faultyRIGHT ENG START VALVE LIGHT DID NOT EXTINGUISH AFTER ENG SWITCH MOVED TO GND. GOT AIR TO ENG. REPLACED STARTER CTR VALVE RT ENG PER MM. ACP CHECK OK. RAN NR 2 ENGINE PER JRH. ALL OPS AND INDICATION NORMAL.SDR UALA2011081504315Anti-Ice Valve · failedL ENG ANTI-ICE EICAS. REPLACED L ENG ANTI-ICE VALVE PER MM, OPS TEST OKAY.SDR UALA2011081504314Anti-Ice Valve · failedEICAS MSG ENG ANTI- ICE DISPLAYED AND ENG ANTI-ICE VALVE LIGHT REMAINED ILLUM WITH SW ON POSITION 1. TROUBLESHOOT PER MM, REPLACED IAW MM,OPS CHECKED NORMAL.SDR UALA2011071903675Window · defective1ST OFFICER'S FIXED SIDE-FORWARD WINDOW'S VISIBILITY IS AFFECTED BY DEFECTS. REPLACE FIRST AVAILABLE. CREW COMMENTS: IN SUN VISIBILITY IS AFFECTED. REPLACED NR 2 RIGHT OPENABLE WINDOW PER MM.SDR UALA2011071903674Window · unserviceableCAPTAIN'S FIXED SIDE-AFT WINDOW'S VISIBILITY IS AFFECTED BY DEFECTS, REPLACE FIRST AVAILABLE. CREW COMMENTS: IN SUN VISIBILITY IS AFFECTED. NR 3 LT WINDOW NEEDS REPLACEMENT. WINDOW REPLACED.SDR UALA2011071503605Cooling Fan · failedFORWARD EQUIPMENT COOLING SUPPLY FAN ON EICAS. REPLACED COOLING FAN, CHECKED GOOD.SDR UALA2011060902849Controller · faultyRIGHT PACK 'AUTO' TEMPERATURE CONTROL SYSTEM(S) INOPERATIVE. DEFERRED PER SAMC. REPLACED RT PACK TEMP CONTROLLER PER MM. CLEANED ALL CABIN TEMP SENSOR SCREEN. RT PACKS OP NORMAL.SDR UALA2011052602575Feeder Cable · damagedEMERGENCY LIGHTS INOP SEATS 3, 4, 5, 6. FOUND EEL POWER CABLE CUT FROM POWER SEAT UNDER SEAT 3. REPAIRED AND SECURED. OPS GOOD.SDR UALA2011050302173Satcom · malfunctionedUPON DEPARTURE FA REPORTED IFE SYS WOULD NOT WORK, FLIGHT WOULD NOT OPEN. INFORMED TO DEFER ITEM. INSTALLED SC-A. SYS OPS CHECK OK.SDR UALA2011040401609Wire · out of positionEMERGENCY EXIT LIGHTS CONNECTED TO POWER SPLY M1209 DO NOT COME ON WHEN FWD & AFT ATTENDANT TEST SWITCH IS PUSHED, WORKS NORMAL WHEN FLT DECK SWITCH IS ON OR ARMED AND POWER IS OFF. FOUND WIRE W1222-106-22 MIS-PINNED, CORRECTED REF WDM. OP CHECKED OKAY.SDR UALA2011040101573Selector Valve · faultyGEAR LEVER STIFF. SUGGEST REPLACING MAIN LANDING GEAR SELECTOR VALVE ACCT BINDING, SHUTTER FELT WHEN ISOLATED FROM NLG SEL VLV WHEN OPERATING GEAR HANDLE UP. VLV ON AOG E4252 PART NUMBER 1U1302-1. MAIN LANDING GEAR SELECTOR VLV PER MM.SDR UALA2011031401217Shutoff Valve · faultyCREW REPORTS AFTER ENG START, THE APU BLEED VALVE APPEARS TO BE STUCK CLOSED. WITH SW ON, NO DUCT PRESSURE AND APU BLD SW VALVE LIGHT IS ON, WITH SW CLOSED, NO DUCT PRESSURE AND APU BLEED SWITCH VALVE LIGHT STILL ON. CYCLED SWITCH NUMEROUS TIMES AND NO HELP.SDR UALA2011030301037Transceiver · weakWEATHER RADAR FAILED. WXR RT WEAK DISPLAYED. INOP PER MEL. REPLACED WXR TRANSCEIVER AS PER MM.SDR UALA2011030201036Control Module · faultyEXTREME EFFORT REQUIRED TO RAISE GEAR LEVER TO UP. MUST BE FIXED BEFORE REVENUE FLT. REPLACING LANDING GEAR CONTROL MODULE. NEED 8 BOLTS 926-0380 FOR NOSE JACK FIXTURE. LANDING GEAR CONTROL MODULE HAS BEEN REPLACED. GEAR NEEDS A GEAR SWING PER SFO STATIONSDR UALA2011022100861Switch · inoperativeAPU BLEED WILL NOT OPEN TO START SECOND ENGINE. UNABLE TO DUPLICATE ON ENG INE RUN AFTER RETURN TO GATE. REPLACED K495 RT BLEED AIR ENGINE START RELAY AS PRECAUTION IAW FIM FAULT CODE. ALSO NOTED DEFECT WITH APU BLEED SWITCH ON 2ND ENGINE RUN. REPLACED SWITSDR UALA2011021500788Circuit Card · faultyAPU VALVE DISAGREE LIGHT DISPLAYED. VALVE CLOSED NORMALLY AND CB PULLED AND COLLARED. APU BLEED WOULD NOT OPEN AFTER STARTING LT ENG. AFTER ACFT RETURNED TO GATE AND LT ENG SHUTDOWN, APU BLEED VALVE OPERATED NORMAL. CHECK APU SHUTOFF VALVE INTERLOCK CIRCUITSDR UALA2011020200570Actuator · inoperativeLEFT THRUST REVERSER OPENING ACTUATOR INOP. REPLACED OPENING ACTUATOR REF AMM. OPS NORMAL.SDR UALA2011011800292Valve · faultyCREW REPORTS NO WATER PRESSURE THROUGHOUT ACFT. POTABLE WATER FILL VALVE LEAKING AIR IN CLOSED POSITION. CONTROL ROD DISCONNECTED FROM VALVE. REPLACED BORROWED WATER FILL VALVE IN AFT PIT, NO HELP. FOUND WATER SYS AIR COMPRESSOR INOP. REPLACED POTABLE WATSDR UALA2011011400224Motor · failedFLAPS WILL NOT DEPLOY IN THE ALTERNATE POSITION. REPLACED FLAP ELECTRIC MOTOR PER MM BUT FLAPS WILL STILL NOT DEPLOY. NO PWR ON CONN D2312. SECURED BACK CONN D2312. FOUND FLAP BYPASS VALVE MIGRATED, RESECURED PIN, OPS CHECKED NORMAL.SDR UALA2010122304702Antenna · corrodedFOUND CORROSION AT SATCOM LEFT ANTENNA. REPLACED LT SATCOM HIGH GAIN ANTENNA AND FWD AND AFT ANTENNA CABLES ON RT AND LT ANTENNAS. ACCOMPLISHED SATCOM SYS TEST, CHECKED NORMAL.SDR UALA2010121304548Connector · faultyACARS NO COMM MOST OF FLIGHT. IAW FIM 23-25-00-101 PARA D(B)UP TO STEP 4 ITEM REPLACED. DID FIND CONNECTORS LOOSE FROM SHIELDS AT HIGH POWER RELAY D2673, D2675. HIGH GAIN SYS LOGS ON FOR APPROX 90 SECONDS THEN SEARCHES AGAIN. CYCLE RESTARTS. HIGH PWR RELAY, PSDR UALA2010120104421Satcom · inoperativeSATCOM INOPERATIVE. RESET, NO HELP. SATCOM MENU NOT AVAILABLE ON CDU. HIGH AND LOW GAIN NOT AVAILABLE. REPLACED SATELLITE DATA UNIT PER MM. OPS CHECKED NORMAL.SDR UALA2010100403652Charger · faultyMAIN BATTERY CHARGER STATUS MESSAGE. REPLACED MAIN BATTERY AND MAIN BATTERY CHARGER, MESSAGE CLEARED AND OPS OK.SDR UALA2010092103501Cap · leakingLT OVER WING FUEL LEAK, FLIGHT DIVERTED. REPLACED LT OVERWING FUEL CAP.SDR UALA2010081102938Battery · failedEICAS MESSAGE MAIN BATTERY CHARGER. BATTERY BAD. REPLACED MAIN BATTERY IAW MM.SDR UALA2010080402834Actuator · faultyC HYD SYS MAINT STATUS MSG CAME ON SHORT FINAL. OPERATED C1 AND C2 PUMPS ONE AT A TIME. C2 ONLY PUTTING OUT 2510 PSI. SHOULD BE 2800-3200 PSI. DEFERRED FOR NO TIME. AIR DRIVEN PUMP & C1 PUMP OK. REPLACED C HYD SYS C2 ACMP, NO HELP. SUSPECT PRESS TRANSMITTER SDR UALA2010062802287Light · inoperativeCOCKPIT EMERGENCY LIGHT INOPERATIVE. REPLACED LIGHT ASSY, OPS CKD OK.SDR UALA2010050301493Controller · failedRT BLEED INOP NO PRESSURE CYCLED CB'S AND SW NO HELP. POWERED ENG UP TO 63 PERCENT N1, NO HELP. REPLACED NR 2 ENG PRSOV (773288-7-8-10 / 29) AND PRV. BITE TEST BLEED AIR CONT SHOWED PRV FAIL. RAN ENGINE, STILL NO BLEED PRESSURES. REPLACED PRV CONTROLLER. RANSDR UALA2010040501115Actuator · faultyRUDDER TRIM INOP, FLIGHT DIVERTED. ACTUATOR FOUND DEFECTIVE. REPLACED RUDDER TRIM ACTUATOR. ACCOMPLISHED RII INSPECTION OF RUDDER TRIM ACTUATOR INSTALLATION. VISUAL FLT CONTROL MOVEMENT CHKS ACCOMPLISHED. ALL OPS & INDICATIONS NORMAL.SDR UALA2010030800793Module · damagedON RETRACTION GEAR HANDLE WAS VERY DIFFICULT TO MOVE THROUGH TOP THIRD OF TRAVEL. REPLACED MLG CONTROL LEVER MODULE.SDR UALA2010021500573Line · leakingON WALK AROUND NOTED LOUD NOISE COMING FROM APU AREA SUSPECT AIR LEAK AT PNEUMATICS BLEED VALVE. SHUTOFF OFF APU BLEED NOISE STOPPED. SECURED CLAMP FURTHER TROUBLESHOOTING FOUND POTABLE WATER PRESSURIZATION LINE BROKEN FROM APU PNEU DUCT BULK PIT LT AFT SIDESDR UALA2010020200423Circuit Card · faultyLT PACK OFF LIGHT WILL NOT COME ON WITH PACK OFF. CHECKED AND RESECURED LT PACK FLOW CONTROL CARD, PACK OPS NORMAL EICAS AND LIGHT INDICATION SHOWING WITH PACK SWITCH OFF.SDR UALA2009112303636Rod · brokenFAN COWL HOLD OPEN ROD ON ENG NR 2 O/B SIDE, IS BROKEN AND UNUSABLE. REPLACED NR 2 ENG O/B FAN COWL HOLD OPEN ROD ASSY.SDR UALA2009111103523Lens · unsecureEMERGENCY EXIT LENS COVER LOOSE AT 2R. SECURED LENS ON EMERGENCY LIGHT. OP CHECKED OKAY.SDR UALA2009102203291Valve · malfunctionedCHRONIC HYD TXF RT & CTR. CONDITION SUGGESTS FLUID XFER VIA ANTISKID SHUTTLE VALVES. REPLACED RT INBOARD SHUTTLE VALVE. NO LEAKS NOTED.SDR UALA2009082102590Pump · malfunctionedAN 1800 LB FUEL IMBALANCE DURING CENTER TANK PUMP USAGE. AND 20.0 LB REMAINING IN CENTER TANK. REPLACED RIGHT CENTER OVERRIDE PUMP, LEAK CHECKED. NO LEAKS NOTED. OPS CHECKS GOOD.SDR UALA2009080402335Power Supply · faultyTWO (2EA) AISLE EEL LIGHTS ABOVE SEATS 2A & 6A ARE INOP. NO VOLTAGE AT LIGHT ASSY'S. WILL NEED SEAT 1A REMOVED TO ACCESS BATTERY CHARGER- POWER SUPPLY TO T-S. ESTIMATE 3 SHIFTS. POWER SUPPLY PCN 563- 1046, 2EA. ADJACENT (OPPOSITE SIDE) AISLE LIGHTS OPERATSDR UALA2009072802253Pressure Switch · faultyRECEIVED MSG, L OIL FILTER STATUS AFT ENG START. NO CONTAMINATION IN C-D'S OR FILTERS. REPLACED MAIN OIL FILTER. RAN ENGINE, NO LEAKS DETECTED. CHIP DETECTORS CLEAN. NEED TO REPLACE DIFF PRESS SWITCH AT FIRST OPPORTUNITY. REPLACED DIFF PRESS SWITCH. NO SDR UALA2009072002134Sign · inoperativeELECTRICAL PROBLEMS IN THE CABIN. FOUND AFT CABIN LAV-OCC SIGN L403 BAD. WILL NEED A NEW ONE. ALSO FOUND BROKEN GROUND WIRE HANGING LOOSE IN LAV M1284 DOOR SWITCH. REPAIRED BROKEN GROUND FOR DOOR SWITCH. RELAMPED HANDICAPPED LIGHT SWITCH S11 FOR LAV M1284SDR UALA2009061501684Oxygen Bottle · low pressureDOOR 2R O2 BOTTLE LOW PRESSURE. REPLACED O2 BOTTLE.SDR UALA2009051101345Pump · malfunctionedADP LOW PRESS LIGHT AND EICAS MSG ON TAKEOFF DURING GEAR RETRACTION & FLAPS 5 TO 1. REPORTED BY CREW. REMOVED AND REPLACED ADP. NO HELP. STILL NEED TO LEAK CHECK, NEEDS FURTHER TROUBLESHOOTING. REPLACED MOD. AIR DRIVEN PUMP AND ADP REG AND SHUTOFF VALVES (3SDR UALA2009042701205Densitometer · faultyDURING CRUISE, CENTER FUEL TANK REFILLED ITSELF FROM 700 LBS TO 1400. FUEL CONFIG LIGHT LIT. ACCOMPLISHED FQ BITE, FOUND 'CT DENS RESISTOR UNREADABLE'. REPLACED CTR TANK DENSITOMETER.SDR UALA2009012100233Panel · damagedRT WING NR 7 LEADING EDGE SLAT CLOSURE PANEL DAMAGED. REINSTALLED REPAIRED PANEL. OPS CHECK NORMAL, FAIR GOOD. REPAIRED PER GN-MM 1-0-1-24.SDR UALA2009011900188Acoustic Liner · damagedNR 2 ENG ACOUSTIC LINER 8 O'CLOCK POS DAMAGED. NR 2 ENG INNER ACOUSTIC PANEL 8 O'CLOCK POSITION CRACKED 4.5 INCHES FORWARD OF LPC BLADES. REPLACED NR 2 ENG NOSE COWL.SDR UALA2009031000038Hose · failedLT OVERWING INFLATION HOSE IS FLATTENED 12 INCHES AT THE SLIDE COMPARTMENT ELBOW. SLIDE REPLACED.SDR UALA2009010500038Slide · faultyLT OVERWING INFLATION HOSE IS FLATTENED 12 INCHES AT THE SLIDE COMPARTMENT ELBOW. SLIDE REPLACED.SDR UALA2009010500028Slide · unserviceableDOOR L1 SLIDE COMING UNLACED. INSTALLED NEW SLIDE AT DOOR L-1.SDR UALA2009010500027Housing · brokenLEFT OVERWING SLIDE COMPARTMENT, DISCONNECT HOUSING IS BROKEN. REPLACED DISCONNECT HOUSING. REINSTALLED LT DISCONNECT CAM ASSY. EXAMINED INFLATION CABLE FOR FREEDOM OF MOVEMENT, CHECKS GOOD.SDR UALA2008122206928Latch · scoredLEFT OVERWING SLIDE COMPARTMENT DOOR LATCH NR 4 IS SCORED. INSTALLED NEW LATCH, OPS CHECKS GOOD.SDR UALA2008122206927Latch · defectiveLEFT OVERWING SLIDE COMPARTMENT DOOR NR 3 LATCH FAILED EDGE MARGIN CHECK. INSTALLED NEW NR 3 LATCH, OPS CHECKS GOOD.
Back to N649UA