SDR HNAA2021081000374Floor Support · corrodedE869884 - RH #1 FLOORBOARD SILL CORRODED ... RAR RH #1 FLOORBOARD SILL IAW EMB 145 SRM 51-40-02. SEE NRTC FOR DETAILSJul 24, 2021 · N652RS · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021081000370Floor Support · corrodedE869890 - RH #2 FLOORBOARD SILL CORRODED. ... RAR RH #2 FLOORBOARD SILL IAW EMB145 SRM 51-40-02Jul 24, 2021 · N652RS · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021081000369Gusset · corrodedE869892 - CENTER #2 OMEGA BEAM UPPER GUSSET CORRODED ... RAR #2 CENTER OMEGA BEAM GUSSET IAW EMB 145 SRM 51-40-02 AND SRM 51-40-09.Jul 24, 2021 · N652RS · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021081000367Gusset · corrodedE869905 - LH #3 OMEGA BEAM UPPER GUSSET CORRODED ... REMOVED AND REPLACED LH #3 OMEGA BEAM UPPER GUSSET IAW EMB 145 SRM 51-40-02.Jul 24, 2021 · N652RS · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021081000362Floor Support · corrodedE870109 - R/H FLOOR SILL #4 IS CORRODED .... RAR R/H FLOOR SILL #4 IAW EMB145 SRM 51-40-02Jul 24, 2021 · N652RS · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021081000358Floor Support · corrodedLEFT NR 4 OMEGA BEAM UPPER GUSSET CORRODED . REMOVED AND REPLACED NR 4 OMEGA BEAM UPPER GUSSET IAW SRM 51-40-02.Jul 23, 2021 · N652RS · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021081000375Gusset · corrodedE869881 - CENTER #1 OMEGA BEAM UPPER GUSSET CORRODED. ... REMOVED AND REPLACED CENTER #1 OMEGA BEAM UPPER GUSSET IAW EMB145 SRM 51-40-02.Jul 23, 2021 · N652RS · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021081000373Floor Support · corrodedE869885 - LH #2 OMEGA BEAM UPPER GUSSET CORRODED ... REMOVED AND REPLACED LH #2 OMEGA BEAM UPPER GUSSET IAW EMB 145 SRM 51-40-02.Jul 23, 2021 · N652RS · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021081000366Floor Support · corrodedE870053 - BOTH FLOOR SUPPORTS CORRODED/GOUGED (BELOW THE PAX DOOR CUTOUT) ... REMOVED AND REPLACED BOTH FLOOR SUPPORTS BELOW THE PAX DOOR CUTOUT IAW EMB 145 SRM 51-40-02.Jul 18, 2021 · N652RS · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021051000199Warning Light · false activationDURING TAKE OFF ROLL AT 30 KNOTS SERVICE DOOR WARNING APPEARED. VERIFIED SERVICE DOOR CLOSED AND LATCHED. C/W FLT CREW PROCEDURE. 00 FACT 09MAY21 00:33 MDT. INSPECTED SERVICE DOOR AND RAN TEST IRT AMM 52-74-00 CND DISCREPANCY. OPS CHECK GOOD AND OK FOR May 7, 2021 · N652RS · Emb EMB145LR · Door Warning SystemSDR HNAA2021042100140Wire · brokenEMERGENCY LIGHT AT ROW 18A AND 17A INOP. REMOVED ROW 18A AND 17A EMERGENCY LIGHT STRIP AND FOUND BROKEN WIRE ON WIRE APLICE CONNECTOR. REMOVED FLOOR PANEL 261BF TO ACCESS BROKEN WIRE REPLACED CONTACT PIN AND THE RECEPTACLE OF THE WIRE SPLICE CONNECTOR. PERFApr 9, 2021 · N652RS · Emb EMB145LR · Light System WiringSDR HNAA2021030200067Warning System · malfunctionedPDIS 652 31-50 2379262 01MAR21 CLT CLOSE. DURING T/O ROLL AT ABOUT 40 KTS, GPWS, TCAS, TERRAIN INOP EICAS MESSAGES WITH TAKEOFF CONFIG WARNING WITH NO RELATED AURAL WARNING. FACT 02MAR21 09:27 CLT R&R AURAL WARNING UNIT IAW AMM 31-51-400-801-A OPMar 1, 2021 · N652RS · Emb EMB145LR · Central WarningSDR HNAA2021030200066Relay · failedDURING T/O ROLL AT ABOUT 30KTS, GPWS, TCAS, TERRAIN INOP EICAS MESSAGES WITH T/O CONFIG WARN WITH NO RELATED ORAL WARNING FACT 01MAR21 17:03 CLT C/N/D, R&R'D RELAY K0212 FOR PRECAUTION. C/W SELF TEST OF GPWS, TCAS AND T/O CONFIG. ALL TESTS PASS. OPS CHECK Mar 1, 2021 · N652RS · Emb EMB145LR · Air Collision Avoidance SystemSDR HNAA2020100500273Handle · failedPDIS 652 32-44 2174051 04OCT20 CLT. CLOSE PARKING BRAKE WILL NOT DISENGAGE, HANDLE WILL NOT MOVE DOWN. FACT 04OCT20 17:09 CLT. R & R PARKING BRAKE HANDLE/CABLE ASSY, IAW AMM 32-44-11. OPERATIONS CHECK GOOD, OK FOR SERVICE.Oct 4, 2020 · N652RS · Emb EMB145LR · Landing Gear Brake SystemSDR HNAA2020092800270Cabin Pressure · malfunctionedPDIS 652 21-31 2174011 27SEP20 LEX CLOSE. CABIN WOULD NOT AUTO PRESSURIZE AFTER TAKEOFF. IN MANUAL, CABIN ALT INDICATION FAILED AFTER 10 MINS. INDICATION CAME BACK AFTER LANDING. FACT 27SEP20 13:30 LEX. INSPECTED CPAM AND CB FOR PROPER OPERATION, NO DEFECSep 27, 2020 · N652RS · Emb EMB145LR · Cabin Pressure Control SystemSDR HNAA2020090100251Spoiler Sys · malfunctionedDURING TAKEOFF ROLL AT ABOUT 70 KTS MASTER WARNING LIGHT ILLUMINATED, SPOILER INDICATED OPEN, AND AURAL WARNING TAKEOFF SPOILERS. SPOILERS CLOSED AFTER T/L RETURNED TO FLIGHT IDLE. NO RELATED CMC MESSAGES FOR TODAY. RESET SPOILER SYSTEM. OPERATIONS CHECK Aug 31, 2020 · N652RS · Emb EMB145LR · Drag Control SystemSDR HNAA2020062200172Unknown · odorDURING CRUISE/APPROACH GOT STRONG ELECTRICAL SMELL IN COCKPIT. NO ASSOCIATED EICAS MESSAGES. SMELL CLEARED WHEN ON GROUND. (OUTSIDE OF ICING CONDITIONS WHEN SMELL OCURRED). MAINTENANCE: T/S ELECTRICAL SMELL IAW FIM 21-20-00-810-801-A. NO ABNORMAL SMELLS NOTED.Jun 21, 2020 · N652RS · Emb EMB145LR · Air Distribution SystemSDR HNAA2019121100383Sensor · failedSPS 1 INOP MSG ON T/O ROLL...FIX:R&RD #1 AOA SENSOR IAW EMB AMM 27-36-01-04 OPS CHECK GOOD. OK FOR SERVICEDec 10, 2019 · N652RS · Emb EMB145LR · Elevator Control SystemSDR HNAA2019112700372Trim System · lack of lubeFO YOKE PITCH TRIM INOP IN FLIGHT. ON GROUND PITCH TRIM UP OK, PITCH RIM DOWN INOP.....FIX:LUBED FOS PITCH TRIM ON YOKE IAW AMM 27-40-03-640-801A.OPS CHECK GOOD.GOOD FOR SERVICE.CLEARED MEL.Nov 18, 2019 · N652RS · Emb EMB145LR · Stabilizer Position IndicatingSDR HNAA2019043000125Flashlight · odorPDIS 652 05-50 2016771 26APR19 CLT CLOSE WHEN SWITCHING FROM F/A CONTROL TO F/D DECK CONTROL ON PACK 2 SLIGHT ODOR NOTICED. ODOR DISSIPATED SHORTLY AFTER. 29363 00 CVS HISTORY: NONE FApr 26, 2019 · N652RS · Emb EMB145LR · Emergency EquipmentSDR HNAA2019042200109Flap System · stuckPDIS 652 05-50 2016731 21APR19 FAY CLOSE REF LP 201672 ITEM 3, DURING GO AROUND WITH FLAPS ST UCK AT 45 DEGREES A/C REACHED 173 KTS FACT 22APR19 08:57 FAY INSP FLAP IAW AMM 05-50-07-212-004-A NO DEFECTS NOTE Apr 21, 2019 · N652RS · Emb EMB145LR · Trailing Edge Flap Control SystemSDR HNAA2019032100075Warning System · false activationPDIS 652 52-40 1931872 18MAR19 PHL CLOSE ON TAKEOFF ROLL SERVICE DOOR OPEN EICAS MSG DISPLAYED. HISTORY: FACT 18MAR19 22:17 PHL INSP SERVICE DOOR FOR DEFECTS W NONE NOTED. SERVICE DOOR OPERATES NORMALLY AT THIS TIME OKAY FOR SERVICE.Mar 18, 2019 · N652RS · Emb EMB145LR · Door Warning SystemSDR HNAA2019011500015Inverter · inoperativeNDIS 652 33-51 0003030 14JAN19 SBY CLOSE FWD CEILING EMERGENCY LIGHT AT ROW 12 INOP. FACT 14JAN19 10:37 SBY R&R NR 6 EMERGENCY LIGHT INVERTER IAW 33-50-11-04. P/N ON INVERTER 1330312 P/N OFF INVERTER 1330312Jan 14, 2019 · N652RS · Emb EMB145LR · Emergency LightingSDR HNAA2019010200001Warning System · false activationPDIS 652 27-38 1735201 01JAN19 MKE CLOSE PTRIM MAIN INOP EICAS MESSAGE ON TAKEOFF. HISTORY: YES FACT 01JAN19 17:08 MKE REST MAIN CHANNEL IN REFERENCE TO FIM 27-43-00-810-801-A OPS CK GOOD IAW AMM 27-40-00-700-802-A NO FAULTS NOTED OK FOR SERVICE.Jan 1, 2019 · N652RS · Emb EMB145LR · Elevator Control SystemSDR HNAA2018121200315Trim System · malfunctionedON CLIMB OUT FO PITCH TRIM FAILED FOLLOWED BY PTRIM MAIN INOP AND PTRIM BACK UP INOP. RAN QRH BACK SYS MOMENTARY CAME BACK ONLINE CYCLED MAIN AND BACK UP CUT OUT. CND DISCREPANCY ON GROUND. R&R HSCU AS MX PRECAUTION OPS CHECK GOOD REF AMM 27-40-00 AND 27-40-01Dec 7, 2018 · N652RS · Emb EMB145LR · Stabilizer Control SystemSDR HNAA2018111600285Contact · dirtyNDIS 652 33-51 0001970 13NOV18 SBY CLOSE ROW 12 EMERGENCY LIGHT ON CEILING IS INOP 33384 00 SPE FACT 13NOV18 07:48 SBY REMOVED CEILING HEADLINER AT ROW 12 IAW AMM 25-22-04-000-801-A. TESTNov 13, 2018 · N652RS · Emb EMB145LR · Light System WiringSDR SIMA2018102220003Flashlight · inoperativeCOCKPIT FLASHLIGHT INOP. C/A-REMOVED AND REPLACED COCKPIT FLASHLIGHT IAW AMM 33-50-16 OPS CHECK GOOD.Oct 20, 2018 · N652RS · Emb EMB145LR · Emergency EquipmentSDR SIMA2018102220002Flashlight · inoperativeAFT CABIN FLASHLIGHT INOP. C/A-REMOVED AND REPLACED AFT CABIN FLASHLIGHT IAW AMM 33-50-16 OPS CHECK GOOD.Oct 20, 2018 · N652RS · Emb EMB145LR · Emergency EquipmentSDR SIMA2018102919004Skin · crackedSKIN CRACKED AROUND RIVETS ON FRAME 80. C/A-ACCOMPLISHED REPAIR IAW SRM 53-32-01.Oct 19, 2018 · N652RS · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA2018102918003Light · inoperativeNUMBER NR 4 EMERGENCY LIGHT STRIP INOP. C/A-REMOVED AND REPLACED NR 4 EMERGENCY LIGHT STRIP IAW AMM 33-50-12.Oct 18, 2018 · N652RS · Emb EMB145LR · Emergency LightingSDR SIMA2018102917005Structure · dentedSERVICE DOOR LOWER EDGE IS DENTED. C/A-REPAIRED SERVICE DOOR LOWER EDGE IAW ERS-EM-52MR-911.Oct 17, 2018 · N652RS · Emb EMB145LR · Service DoorsSDR SIMA2018102910002Web · gougedCARGO DOOR WEBBING HAS SEVERAL GOUGES. C/A-REPAIRED BAGGAGE DOOR INNER WEB CHAFES IAW SRM 52-30-01 AND ETN-EM-52-043.Oct 10, 2018 · N652RS · Emb EMB145LR · Cargo/Baggage DoorsSDR SIMA2018102905005Wire · brokenLT NR 2 FLOOR PROXIMITY EMERGENCY LIGHT WIRES BROKEN. C/A-REMOVED AND REPLACED LT NR 2 FLOOR PROXIMITY EMERGENCY LIGHT IAW AMM 33-50-12.Oct 5, 2018 · N652RS · Emb EMB145LR · Light System WiringSDR SIMA2018102926005Fitting · crackedLT ENG FWD YOKE LOWER FWD FITTING CRACKED. C/A-COMPLETE:ERS-EM-54MR-698 FOR CRACKED LT ENGINE FORWARD YOKE LOWER FORWARD FITTING SATISFACTORILY ACCOMPLISHED.Sep 26, 2018 · N652RS · Emb EMB145LR · Engine Mount SectionSDR SIMA201808275003Bulb · burned outDURING A PS-1 CHECK, FOUND AN EXTERNAL EMERGENCY LIGHT ON THE LT CENTER FAIRING, BURNED OUT. REMOVED AND REPLACED THE BULB IAW AMM 33-50-10. OPS CHECKED GOOD. NO FURTHER DEFECTS NOTED.Aug 25, 2018 · N652RS · Emb EMB145LR · Emergency LightingSDR SIMA20180611005Unknown · odorFUMES IN COCKPIT & FORWARD CABIN SIMILAR TO DIRTY GYM BAG WITH HINT OF OIL NO EICAS INDICATIONS DURING DESCENT AND LEVEL OFF WHILE INCREASING POWER TO MAINTAIN SPEED GOT WORSE WITH INCREASE IN POWER BOTH PACKS POWERED BY THEIR RESPECTIVE BLEED NOTHING ASSOCIATJun 11, 2018 · N652RS · Emb EMB145LR · Air Distribution SystemSDR SIMA2018051400002Flashlight · odorODOR OF SMOKE IN THE COCKPIT. PERFORMED AN ENGINE RUN IAW MM 72-00-00, AND APU RUNS. FOUND THE ODOR COMING FROM FIRST OFFICER`S SIDE FLASHLIGHT. REMOVED AND REPLACED THE FLASHLIGHT. NO ODOR NOTEDMay 12, 2018 · N652RS · Emb EMB145LR · Emergency EquipmentSDR SIMA2018042019007Connector · inoperativeFLOOR EMERGENCY LIGHT AT SEAT 18A FOUND INOPERAIVE. REMOVED AND REPLACED THE EMERGENCY LIGHT CONNECTOR IAW SWPM 20-50-01. OPS CHECKED GOOD.Apr 19, 2018 · N652RS · Emb EMB145LR · Light System WiringSDR SIMA20180216001Bulb · not seatedRIGHT AFT OVERWING EXIT LIGHT INOPERATIVE. REMOVED, RESEATED AND REINSTALLED THE BULB IAW AMM 33-50-10 . OPS CHECKED GOOD.Feb 16, 2018 · N652RS · Emb EMB145LR · Emergency LightingSDR SIMA20180212001Light · inoperativeCOCKPIT OVERHEAD EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE COCKPIT EMEGENCY LIGHT IAW AMM 33-50-05-000-801, AND 33-50-05-400-801. OPS CHECKED GOOD.Feb 12, 2018 · N652RS · Emb EMB145LR · Emergency LightingSDR SIMA20180207005Bulb · inoperativeMAIN DOOR EMERGENCY LIGHT INOPERATIVE. R & R THE BULB AND OPS CHECKED GOOD IAW AMM 33-50-06.Feb 7, 2018 · N652RS · Emb EMB145LR · Emergency LightingSDR SIMA20180103002Acm · failedSTRONG ODOR OF BURNING, NO INDICATION OF ANY FIRE. THE ODOR WAS WITH THE NR 2 PACK. COMPLIED WITH ETN-EM-72-034, THE NR 2 PACK OVERHEATT MESSAGE NOTED. NO DEFECTS NOTED ON THE NR 1 PACK. REMOVED AND REPLACED THE NR 2 ACM IAW AMM 21-51-03, OPS CHECKED Jan 3, 2018 · N652RS · Emb EMB145LR · Cabin Cooling SystemSDR SIMA20171210001Lamp · inoperativeRH WING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED THE RH WING EXTERNAL EMERGENCY LIGHT LAMP IAW EMB 145 AMM 33-50-10, OPS CHECK GOODDec 10, 2017 · N652RS · Emb EMB145LR · Emergency LightingSDR SIMA20170928003Lamp · inoperativeLEFT FORWARD EXTERIOR EMERGENCY LIGHT INOPERATIVE. R & R THE LAMP IAW AMM 33-50-10-000-801-A, AND 33-50-10-400-801-A. OPS CHECKED GOOD.Sep 28, 2017 · N652RS · Emb EMB145LR · Emergency LightingSDR SIMA20170716003Cradle · inoperativePREVIOUS CREW REPORTED STRONG BURNING ODOR IN THE CABIN WHILE FLYING THROUGH THUNDERSTORMS, FOUND BURNING ODOR ON FED FLASHLIGHT CRADLE. REMOVED AND REPLACED FWD CABIN EMERGENCY FLASHLIGHT ASSY IAW AMM 33-50-16.Jul 16, 2017 · N652RS · Emb EMB145LR · Emergency EquipmentSDR SIMA20170524003Sensor · false indicationON ROTATION A BRAKE OVERHEAT ILLUMINATED ON EICAS. THE LEFT INBOARD DETECTOR TOP OF SCALE. FA REPORTED ODD NOISE WHEN RETRACTING GEAR, ALL OTHER INDICATORS FOR BRAKE TEMP GREEN. ALL MTX PROCEDURES COMPLIED WITH. REPLACED THE LT, INBD BARKE TEMP SENSOR IAW AMay 24, 2017 · N652RS · Emb EMB145LR · Landing Gear Position and WarningSDR SIMA20170519001Connector · misinstalledAFTER TAKE OFF, A BRAKES OVERHEAT ON EICAS. PERFORMED THE CHECKLIST, UNABLE TO RESTORE. REMOVED AND REPLACED THE NR 1 BRAKE TEMPERATURE SENSOR IAW AMM 32-47-01. OPS CHECKED GOOD. DURING TROUBLESHOOTING, FOUND THE NR 1 AND 2 BRAKE TEMP SENSOR CONNECTORMay 19, 2017 · N652RS · Emb EMB145LR · BrakeSDR SIMA20161218003Light · inoperativeROW 12 CIELING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACEDTHE EMERGENCY LIGHT. OPS CHECKED GOOD IAW AMM 33-50-07.Dec 18, 2016 · N652RS · Emb EMB145LR · Emergency LightingSDR SIMA20161213001Charger · failedRT & LT EXTERIOR OVERWING EMERGENCY LIGHTS INOP. REMOVED AND REPLACED NR 4 BATTERY CHARGER. OPS CHECKED GOOD IAW AMM 33-50-04.Dec 13, 2016 · N652RS · Emb EMB145LR · Emergency LightingSDR SIMA20161117002Switch · obstructedAFTER ROTATION AND DURING GEAR RETRACTION, RECEIVED "ACCESS DOORS OPEN" CAUTION MESSAGE AND FOWARD AVIONICS ACCESS HATCH OPEN INDICATION ON MFD DOORS PAGE-C/A-UPON FURTHER INVESTIGATION FOUND SEAL OBSTRUCTING SWITCH. RESEATED DOOR AND OPS CHECK GOOD IAW EMB 14Nov 17, 2016 · N652RS · Emb EMB145LR · Door Warning System
Back to N652RS