Service difficulty report · Connector · Emb EMB145LR

Difficulty date
May 19, 2017
Submitted
May 25, 2017
Operation
Air carrier
Aircraft
N652RS
Make and model
Emb EMB145LR
Aircraft serial
145432
Aircraft time
38,420 hours, 34,497 cycles
System (JASC)
3242 · Brake
Part
Connector
Condition
Misinstalled
Location
Brk Temp Sensor
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER TAKE OFF, A BRAKES OVERHEAT ON EICAS. PERFORMED THE CHECKLIST, UNABLE TO RESTORE. REMOVED AND REPLACED THE NR 1 BRAKE TEMPERATURE SENSOR IAW AMM 32-47-01. OPS CHECKED GOOD. DURING TROUBLESHOOTING, FOUND THE NR 1 AND 2 BRAKE TEMP SENSOR CONNECTORS SWITCHED. PROPERLY CONNECTED THE NR 1 AND 2 BRAKE TEMP SENSORS IAW CMM 32-10-01 AND WM 32-47-50. OPS CHECKED GOOD.