N653UA
Service difficulty reports · 315
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N653UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N653UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010062302233Actuator · leakingLEAK APPEARS TO BE COMING FROM AFT OTBD AREA OF WHEEL WELL AREA. DOOR WAS WET ON AFT EDGE AND WIPED DOWN. UNABLE TO LOCATE, PULLED FROM ACFT. RT WHEEL WELL. REPLACED SIDE BRACE ACTUATOR, NO LEAKS FOUND. OPS CHECKS GOOD.SDR UALA2010061402093Eec · faultyWITH ONLY THE RT ENGINE RUNNING YOU GET NO MESSAGE BUT WITH BOTH ENGINES RUNNING YOU GET RT ENG CONTROL MESSAGE. REPLACED NR 2 ENG EEC, NO HELP. MESSAGES (R ENG EEC C2 & R ENG CONTROL) STILL DISPLAYED AND WILL NOT ERASE AFTER ENG RUNS. REPLACED EEC ALTERNATORSDR UALA2010060902003Skin · damagedFOUND DAMAGE ON ARRIVAL, DAMAGE IS AN EDGE GOUGE AFT OF FWD CARGO DOOR STA 618 APPROX 3.5' ABOVE BOTTOM OF DOOR FRAME. GOUGE IS THE FULL DEPTH OF SKIN AT THE EDGE OF THE FRAME 0.160", GOUGE STARTS 3-16" FROM AN EDGE OF A RIVET, THE RIVET CTR IS 13-16" FROM THESDR UALA2010060701972Relay · faultyALL FLIGHT DECK QTY INDICATORS SHOW 0.01, BATTERY CHARGER INDICATES 0, AND MOST OF THE CABIN LIGHTING INOP. FOUND GRD SERVICE TRANSFER RELAY K102 AT FAULT. REPLACED RELAY K102 BAT CHGR, HYD QTY AND CABIN LIGHTING CK GOOD. ALL BUSES POWERED. NO FAULTS DETECSDR UALA2010052501790Battery Pack · dischargedEMERGENCY LIGHTS INOP ROW 22GH TO 19GH. REPLACED BATTERY PACK, OP CHECKS GOOD.SDR UALA2010041601274Bpcu · faultyEICAS MSG(L, R)UTIL BUS OFF DISPLAYED. UTILITY BUS OFF LIGHT ILLUMINATED SYS FAILED TO RESET. THIS OCCURRED DURING (GRD OPRN, 2 GEN OPRN INFLT). (01=L,02=R,03=L&R) 3 BITE OF BPCU SHOWED (REPLACE BPCU) AND SERIAL DATA LINK FAILED. REPLACED BPCU. RAN BOTH ENGINSDR UALA2010041401257Control Panel · faultyRUDDER TRIM FAILED TO TRIM IN EITHER DIRECTION. TRIM WILL INTERMITTENTLY WORK FOR VERY SHORT TIME. FAILED 90 PERCENT OF TIME. REPLACED RUDDER TRIM ACTUATOR AND RUDDER TRIM AILERON CONTROL PANEL AND ACCOMPLISH TESTS IAW MM AND ALL CHECKS.SDR UALA2010041201234Actuator · faultyWENT INOP DURING FLIGHT, RUDDER TRIM CB' S TOUCHED AND RUDDER TRIM WORKED FINE. REPLACED RUDDER TRIM ACTUATOR AND REPLACED RUDDER AND AILERON TRIM CONTROL MODULE. ALL OP'S CHECKED NORMAL.SDR UALA2010040501107Fitting · looseALT DISAGREE EICAS, RTFL. TROUBLESHOT SYS AND FOUND FITTINGS LOOSE ON F/O PITOT HEAD. SECURED FITTINGS. ACCOMPLISHED THE LOW RANGE AND HIGH RANGE LEAKAGE CHECK, SYS TESTS GOOD.SDR UALA2010031900915Transmitter · faultyHYD QTY READS ZERO, HYD QTY LIGHT ILLUM. EICAS MSG DISPLAYED (L,R,C) HYD QTY HYDRAULIC LOW PRESS LIGHT IS EXTINGUISHED. POS 1 (01=L,02=R,03=C). REPLACED HYD QTY IND PER MM. REPLACED HYD QTY MONITOR UNIT. OPS CHECK OKAY. SERVICED HYD LEFT SYSTEM.SDR UALA2010031700891Trim System · malfunctionedRUDDER TRIM ISSUE. NO MOVEMENT OF RUDDER WITH RUDDER TRIM KNOB. AFTER TURNING, TRIM OPERATION RETURNED TO NORMAL. RUDDER TRIM FUNCTION CHECK ACCOMPLISHED. NO DEFECT NOTED. SAMC ADVISED NO ACTION REQUIRED. THE SAMC CONTROLLER AND MANAGER CONCURR THAT THE SDR UALA2010022300665Connector · contaminatedON DEP STATUS MSG ENG RT FIRE LOOP 2. SWAPPED AFLOTS CARDS PER MM AND NO HELP. RESWAPPED CARDS. TRIED NEW CARD M684 PER MM AND NO HELP. REFITTED ORIGINAL. FOUND STRUT PLUG D4154P CONTAMINATED WITH WATER. CLEANED PLUG AND MSG CLEARED. TESTS NORMAL.SDR UALA2010021200529Circuit Card · faultyRT ENG OH LP2 INOPERATIVE. REPLACED CARD M684, FIRE TEST PASSED. NO MESSAGE.SDR UALA2010021200528Circuit Card · faultyRT ENG FIRE LOOP 2 INOPERATIVE. REPLACED LOOP 2 CARD M684, FIRE TEST PASSED.SDR UALA2010021200530Nut · wrong partFOUND MAIN OIL FILTER HOUSING CAP NUTS NOT MATCHING. FOUND SELF-LOCKING NUTS INSTEAD OF KNURLED NUTS.INSTALLED 4 SELF-LOCKING NUTS WHICH EXCEED THE STRENGTH & PERFORMANCE OF THE ORIGINAL PARTS. LEAK CHECK, OKAY.SDR UALA2010020500457Transmitter · faultyLATE IN TAKEOFF ROLL FUEL RT FLUCTUATED AT 1700 LBS FF DID NOT MATCH UNTIL LATER IN FLT IAW CREW ALL OTHER ENGINE INDICATIONS NORMAL. R & R FUEL FLOW TRANSMITTER. ACCMP'D LEAK CHK. NO LEAKS NOTED.SDR UALA2010020100413Cable · damagedAPU GEN WILL NOT STAY ON LINE. FIELD LIGHT FOR APU GEN LIGHT ON P-61 TRIED MANY TIMES TO RESET, NO JOY. TRIED NEW GCU, NO HELP. FOUND GEN FEEDER CABLES BROKEN AT LUG T2 TERM BLOCK, STUDS ON GEN LOOSE, MAY NEED TO REPLACE 4 LUGS FOR GEN FEEDER CABLES. PULLED SDR UALA2010011500188Pressure Switch · damagedFUEL PRESSURE SWITCH PROBLEM. DURING EC6251-1 ACCOMPLISHMENT FOUND FUEL DIFFERENTIAL PRESSURE SWITCH CONNECTOR (D2064) LOOSE AND GETTING APART. FURTHER INVESTIGATION REVEALED SWITCH AND CONNECTOR THREADS ARE DAMAGED. REPLACED FUEL DIFFERENTIAL SWITCH, IDLE LESDR UALA2009102303319Static Inverter · malfunctionedCREW REPORT STANDBY INVERTER MSG ON EICAS WITH SMOKE IN COCKPIT. STATIC INVERTER REPLACED. ALL CHECKS GOOD.SDR UALA2009082002556Indicator · malfunctionedALTITUDE DISAGREE, RTFL. CHECKED F/O SIDE WITH CASTLEBERRY AND VERIFIED FLUCTUATION. REPLACED RT AIR DATA COMPUTER AND RE-TESTED. SYSTEM CHECKED OK WITH CASTLEBERRY. NEEDS CHECK CONFIRMATION WITH LAVERSAB TESTER. CHECKED ADC'S FOR FAULTS. ACCOMPLISHED ADSDR UALA2009061501679Acoustic Liner · crackedNR 1 ENGINE ACOUSTIC LINER HAS A 1.25 INCH CRACK LOCATED 0.25 INCH FWD OF THE FAN RUBSTRIP AT THE 10 O'CLOCK POSITION. THE DAMAGED CRACKED AREA IS ALSO DENTED FROM CRACK AFT TO RUBSTRIP JOINT. CRACK MUST BE CHECKED PRIOR TO EACH DEPARTURE AND INLET COWL MUSTSDR UALA2009043001264Access Door · dentedFWD ACCESS DOOR SECTION 41 SUSTAINED DAMAGE. MAJOR REPAIR ACCOMPLISHED, DENT OUT OF LIMITS. CUTOUT DAMAGED DOOR SKIN, INSTALLED DOUBLER REPAIR.SDR UALA2009042901238Cable · kinkedLT OVERWING EXIT DOOR EXTERNAL STEP DID NOT FREEFALL DUE TO CABLE BEING KINKED. INSTALLED NEW CABLES (2) ON OVERWING EXIT DOOR EXT STEP.SDR UALA2009042901237Housing · crackedLEFT OVERWING SLIDE COMPARTMENT DISCONNECT HOUSING IS CRACKED. INSTALLED NEW DISCONNECT HOUSING.SDR UALA2009042901236Pin · burnedAPU GENERATOR FEEDER CONNECTOR D4016P PIN 'A' IS BURNED AND SHOES SIGNS OF ARCING. REPLACED PIN 'A' OF APU CONNECTOR AND OPS CHECKS GOOD.SDR UALA2009042701198Latch · out of adjustLT OVERWING SLIDE COMPARTMENT DOOR FAILED LATCH TORQUE CHECK, TORQUE WAS IN EXCESS OF 250 IN. LB. INSTALLED 4 EA LATCHES AT LT SLIDE COMPT DOOR. LATCH ALIGNMENT CHECK GOOD. LATCH INSTALL TEST GOOD.SDR UALA2009031000681Blower · faultyAFT DETECTOR FAN POS-1 DISPLAYED. REPLACED BLOWER & RELAY. NO STATUS OR MAINTENANCE MSGS DISPLAYED. ACP TEST OF THE SMOKE DETECTOR BLOWER INSTALLATION PER MM 26-16-02, OPS CHECKS NORMAL WITH ASSOCIATED MSGS. RELAY K322 OPS NORMAL DURING TEST.SDR UALA2009030200681Blower · faultyAFT DETECTOR FAN POS-1 DISPLAYED. REPLACED BLOWER & RELAY. NO STATUS OR MAINTENANCE MSGS DISPLAYED. ACP TEST OF THE SMOKE DETECTOR BLOWER INSTALLATION PER MM26-16-02, OPS CHECKS NORMAL WITH ASSOCIATED MSGS. RELAY K322 OPS NORMAL DURING TEST.SDR UALA2008121106841Detector · faultySTATUS MSG R ENG OH LP2 DISPLAYED. REPLACED SUSPECT HEAT DETECTOR.SDR UALA2008111306301Connector · unsecureFWD EEL CROSS-AISLE LIGHT IS INOP. SECURED RIBBON CONNECTOR. CHECKS GOOD.SDR UALA2008111306300Connector · unsecureMID CABIN EEL CROSS-AISLE LIGHT IS INOP. SECURED RIBBON CONNECTOR. CHECKS GOOD.SDR 2008UALA06301Light · inoperativeFWD EEL CROSS-AISLE LIGHT IS INOP.SDR 2008UALA06300Light · inoperativeMID CABIN EEL CROSS-AISLE LIGHT IS INOP.SDR 2008UALA05842Panel · splitRT WING LOWER PANEL 651VB (REAR OF LDG GEAR) HAS 5.5 INCH SPLIT IN FWD EDGE. REPAIRED T/E PANEL ON R&R. COMPLETED GEAR SWINGS FOR ADEQUATE CLEARANCE BTWN RIGHT GEAR FIXED STRUT DOOR & LWR WING PANEL.
SDR 2008UALA05564Mechanism · underservicedEXIT DOOR 2R ARMING LEVER & BUTTON HARD TO OPERATE. FOUND MECHANISM UNDERSERVICED. CLEANED & LUBED ARMING MECHANISM. OPS CHECKED NORMAL.SDR 2008UALA05515Slide · lowDOOR 1L ESCAPE SLIDE PRESSURE LOW. FOUND SLIDE PRESSURE LOW. REPLACED 1R ESCAPE SLIDE PACK. OKAY FOR SERVICE.SDR 2008UALA04349Starter · failedNR 1 ENGINE STARTER FAILED DURING ENGINE START. STARTER FAILURE. REPLACED ENGINE STARTER. OPS CHECK NORMAL.SDR UALA2008111303782Connector · defectiveVIBRATION FELT IN CONTROL COLUMN. FLIGHT DIVERTED. FOUND DEFECTIVE CONTACTS ON CONNECTOR 4367J AND REPAIRED. PERFORMED SINGLE SYSTEM ELEVATOR TEST GOOD. PERFORMED SINGLE SYSTEM RUDDER TEST GOOD.SDR 2008UALA03782Control Column · vibrationVIBRATION FELT IN CONTROL COLUMN. FLIGHT DIVERTED.
SDR 2008UALA03712Unknown · unknownWATER SYSTEM PROBLEM. RTFL.SDR 2008UALA03700Bracket · crackedCRACK FOUND IN L2 WINDOW TRACK BRACKET. REPLACED L2 WINDOW BRACKET.SDR 2008UALA03468Seal · noisyWINDOW SEAL BEGAN TO SQUEAL LOUDLY. CAPTAIN REPORTED, NOISE IS TOO LOUD TO OPERATE SAFELY, RTFL. REPLACED SEAL. APPLIED SEALANT AROUND FILLET. PERFORMED PRESSURE CHECK. ALL CHECKS NORMAL.
SDR 2008UALA02882Skin · dentedRT WING INBD FLAP T/E IS DENTED. REPAIRED IAW GN-6-0-2-19. AC OK FOR SERVICE.
SDR 2008UALA02792O-Ring · leakingLOW BOTTLE PRESSURE. BOTTLE TO VALVE O-RING LEAKING. REPLACED O-RING.SDR 2008UALA02710Control Valve · malfunctionedLEFT PACK FLOW CONTROL VALVE WILL NOT OPEN. AFTER TROUBLE SHOOTING FOUND FLOW CONTROL, SHUTOFF VALVE FAULTY. REPLACED LT PACK FLOW CONTROL VALVE. OPS CHECKED GOOD.AC OK FOR SERVICE.SDR 2008UALA02693Hose · collapsedRIGHT OVERWING SLIDE INFLATION HOSE COLLAPSED. SUSPECT AC MAINTENANCE. REPLACED HOSE ASSEMBLY. AC OK FOR SERVICE.SDR 2008UALA02406O-Ring · leakingCREW REPORTS 1R DOOR SLIDE LOW PRESSURE. SUSPECT FAULTY O-RING.REPLACED 1R DOOR SLIDE ASSEMBLY REF MM 25-66-01.AC OK FOR SERVICE.SDR 2008UALA02199Fan Blade · damagedNR 2 ENGINE SEVERAL FAN BLADES DAMAGED NR 11, 25 AND 30. LEADING EDGE CLOSE TO TIP.SDR 2008UALA01840Idg · malfunctionedR GEN DRIVE LIGHT ON CONTINUOUSLY. REPLACED NR 2 ENG IDG. OP CHECKED AND LEAK CHKD OK. A/C OK FOR RETURN TO SERVICE.SDR 2008UALA01086Sensor · out of adjustAN 'AIR-GND DISAGREE' EICAS MSG DISPLAYED. PERFORMED THE MM32-09-07-210 AIR-GRD SENSOR TEST IN AIR MODE BY JACKING THE ACFT. FOUND S268 TILT SENSOR OUT OF RANGE PER MM 32-61-99 PG 601. REPLACED S268 TILT SENSOR. ACFT OK FOR SERVICE.