What was found
AFT DETECTOR FAN POS-1 DISPLAYED. REPLACED BLOWER & RELAY. NO STATUS OR MAINTENANCE MSGS DISPLAYED. ACP TEST OF THE SMOKE DETECTOR BLOWER INSTALLATION PER MM 26-16-02, OPS CHECKS NORMAL WITH ASSOCIATED MSGS. RELAY K322 OPS NORMAL DURING TEST.