N654UA
Service difficulty reports · 382
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N654UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N654UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2013100291658Oxygen Mask · leakingOBSERVERS MASK ON P61 PANEL FOUND TO BE LEAKING. R & R OBSERVERS O2 MASK IAW AMM, LEAK & FLOW CHECKED GOOD.SDR CALA2013100191622Control Panel · unsecureCONTROL PANEL ABOVE FA JUMP SEAT AT DOOR 2R NEEDS TO BE RESECURED. RESECURED CONTROL PANEL AT DOOR 2L ABOVE FA JUMP SEAT.SDR CALA2013092691494Actuator · malfunctionedEICAS AILERON LOCKOUT ON DESCENT LEAVING 8,000. EICAS CLEARED ITSELF IAW REF LM7279. INSTALLED SERVICEABLE RT AILERON LOCKOUT ACTUATOR. OPERATIONS CHECKED NORMAL.SDR CALA2013092591459Actuator · faultyRIGHT AILERON LOCKOUT EICAS DISPLAYED. DUE TO HISTORY OF AILERON LOCKOUT EICAS MESSAGE DISPLAYED, IAW SVC TIP MM27-11-44 PG 200A REPLACED THE RIGHT AILERON LOCKOUT ACTUATOR IAW MM. IAW IPC 27-11-44-01 ITEM 56 PCN (563-9035). INSTALLED SERVICEABLE RIGHT AILEROSDR CALA2013090991140Battery · faultyMAIN BATTERY CHARGER STATUS MESSAGE DISPLAYED. REPLACED BATTERY & CHARGER. BATTERY PART NO BA06-01, SN 099395, CHARGER PART NO 8-930-03, SN C2364, IAW AMM 24-31-01 & 24-31-02. CHECKED FOUND OKAY.SDR CALA2013090991124Charger · faultyBATTERY CHARGER STATUS MESSAGE ON EICAS. REPLACED BATTERY CHARGER IAW AMM. ALL CHECKED NORMAL.SDR CALA2013082690743Oil Filter · dirtyAFTER ENGINE START, RT ENGINE OIL FILTER BYPASS EICAS MESSAGE. CHECKED ALL CHIP DETECTORS, OKAYED. REPLACED RT ENGINE OIL FILTER IAW AMM 79-35-00, OKAYED. IDLE LEAK CHECK ACCOMPLISHED. NO LEAKS OKAYED.SDR CALA2013081490456Transceiver · failedWEATHER RADAR FAILED TEST. REPLACED WEATHER RADAR TRANSCEIVER IAW MM, ALL OPS & INDICATIONS NOW NORMAL.SDR CALA2013081390428Wire · exposedP52, PIGTAIL AFT GALLEY EXPOSED WIRES. WIRES ARE STILL INSULATED. CB PULLED AND COLLARED. REPLACED: REPLACED PIGTAIL. OPS CK NORMAL.SDR CALA2013081290332Skin · scratchedFOUND SCRATCH IN RT TOP CORNER AFT BULK CARGO DOOR. SCRATCH IS ON FUSELAGE RT SIDE NEAR BULK CARGO DOOR FWD OF STATION 1461 AND ABOVE S-26L, DIMENSION L=1.57, W=0.03, DEPTH AFTER CLEANUP 0.03. NO CRACKS FOUND, NO LOOSE RIVETS IAW SRM 53-00-01, DMG 1. EVALUATSDR CALA2013080990294Wire · chafedLEFT GENERATOR KICKED OFF IN FLIGHT. FOUND CHAFED WIRE ON NR 1 ENG. FOUND MSG GEN-WIRING ON BPCU. CHECKED IAW FIM 24-20-00 AND WDM 24-21-11 FOUND RES TO BE NORMAL IAW TABLE 102, PG 170 AND 171. IDG REPLACED X2, CHECKED NEUTRAL AND T1, T2, T3 FEEDERS FOR OPSDR CALA2013080890271Generator · deactivatedLEFT ENGINE GENERATOR DROPPED OFF LINE IN FLIGHT.SDR CALA2013080790235Generator · trippedLEFT ENGINE GENERATOR FELL OFF LINE. COULD NOT DUPLICATE, NO DAMAGE FOUND.SDR CALA2013080690182Panel · damagedRIGHT INBD WING ROOT PANEL DAMAGE. CARRIED OUT TEMP REPAIR IAW ENGINEERING HIGH SPEED TAPE APPLIED SLAT POS .6 RT WING.SDR CALA2013080590132Insert · missingMETAL HOLDING UP PIGTAIL UNATTACHED. TWO INSERTS IN UNDERSIDE OF COUNTER MISSING, REMOVED PIGTAIL AND GUARD AT P61, CIRCUIT BREAKER COLLARED.SDR UALA2013071204893Splice Plate · looseNR 2 ENGINE HEATSHIELD HAS SEVEN LOOSE FASTENERS ON THE INBD SIDE OF PYLON. DURING REPAIR IAW AMM 54- 50-98 PG 802, BORESCOPE SHOWED A CRACKED RT PYLON AFT SPLICE PLATE. FABRICATED A REPLACEMENT SPLICE PLATE IAW DWG 313T3355 AND INSTALLED IAW AMM.SDR UALA2013070904782Drain Line · cloggedBUSINESS CLASS GALLEY DRAIN CLOGGED. FOUND CLOGGED BETWEEN SINK AND DRAIN STRAINER. HAD TO STOP WORK DUE TO CATERING AMD AC MOVE. IS FIRST CLASS GALLEY DRAIN CLOGGED.SDR UALA2013062704503Panel · missingNR 1 ENGINE NACELLE HAS ONE STRUT ACCESS PANEL MISSING OTBD 436AL. I INSTALLED PANEL 436AL OTBD NR 1 PYLON.SDR UALA2013061704163Sliding Window · faultyNEED TO REPLACE COCKPIT SLIDING WINDOW RT SIDE. INSTALLED NEW WINDOW, NR 2 POSITION IN COCKPIT IAW REF AMM.SDR UALA2013061304067Headset · broken1ST OBSERVERS MINITEL HEADSET BROKEN. REPLACED WITH SPARE. ITEM DEFERRED IAW MEL. REPLACED MINITEL HEADSET.SDR UALA2013060703991B-Nut · leakingFUEL LEAKING FROM LOWER FUEL LINE TO FUEL OIL COOLER. FOUND LARGE B-NUT LOOSE. SECURED AND MOTORED ENG, NO LEAKS.SDR UALA2013052403615Microphone · stuckFIRST OFFICER`S HAND MICROPHONE STICKS RESULTING IN A STUCK MIC. R & R HAND MIC, OPS CHECKED NORMAL.SDR UALA2013052403601Seal · leakingWINDOW SQUEAL BEGINS AT 3.3 PSID. APPEARS TO BE LEAKING FROM BOTTOM CENTER. R2 WINDOW REPAIRED.SDR UALA2013052103499Lamp · inoperativeEMERGENCY LIGHT AT LEFT AFT CROSS AISLE INOPERATIVE. REPLACED LAMP, OPS CHECKED NORMAL.SDR UALA2013052103498Lamp · inoperativeEMERGENCY LIGHT AT SEAT ROW 9JK INOPERATIVE. REPLACED LAMP, OPS CHECKED NORMAL.SDR UALA2013052003468Transceiver · failedDURING WEATHER RADAR TEST, RECEIVED A "WXR FAIL RT" MESSAGE. REPLACED WEATHER RADAR TRANSCEIVER IAW MM.SDR UALA2013052103511Fairing · missingRT ENGINE LOOKING AFT FROM ENGINE 5 O'CLOCK POSITION COMPRESSOR INTERMEDIATE CASE FAIRING RT SIDE PANEL SECTION MISSING. REPAIRED PER AMM 72-34-05. REPLACED MISSING FAIRING.SDR UALA2013051303317Unknown · leakingNR 2 ENGINE FUEL LEAK AT 6 O'CLOCK POSITION. NO LEAKS NOTED. ENG GROUND RUN IAW JRH. REINSPECTED, NO LEAKS NOTED. REPLACED FUEL DISTRIBUTION VALVE IAW AMM. RAN NR 2 ENGINE, NORMAL OPERATION, NO LEAKS.SDR UALA2013051303316Blade · nickedNR 2 ENGINE FAN BLADE NR 10 HAS NICK ON L/E. DAMAGE IS 10 INCHES FROM ROOT TO A DEPTH OF 1MM. DAMAGE BLENDED OUT IAW MM.SDR UALA2013042502902Pcu · leakingLEFT HYD FLUID LOSS, FLIGHT DIVERTED. REPLACED MIDDLE RUDDER PCU DUE TO A RUNNING LEAK IAW MM. OPS CHECKED NORMAL, NO LEAKS.SDR UALA2013032501822B-Nut · leakingCREW REPORTED LEFT HYD QTY BEGAN TO DECREASE AFTER ENGINE START. SUPPLEMENTAL DATA UPDATE AFTER SERVICING L HYD SYSTEM, ACCOMPLISHED ENG RUN PER JRH 2-6-1, EXERCISED ALL FLT CONTROLS SEVERAL TIMES,CHECKED CENTER RUDDER PCA, UNABLE TO FIND HYD LEAK. FOUND LT YSDR UALA2013031801602Shutoff Valve · faultyLEFT PRV TO BE REPLACED, UNABLE TO OPEN VALVE. REPLACED PRV, NOW OKAY.SDR UALA2013020100604Motor · faultyAPU FAILED TO START 2 ATTEMPTS. REPLACED STARTER MOTOR AS PER AMM MFG 651-1150 AND REPLACED APU CONTROLLER AS PER AMM 49-61-05. APU OPS CHECK OK NOW.SDR UALA2013011700311Shutoff Valve · faultyLEFT AND RIGHT DUCT SPLIT. REF DF548, TROUBLESHOOT PROBLEMS IN ENGINE PNEUMATIC SYSTEM TO PRV & PRC. REMOVED AND REPLACED NR 2 ENGINE PRV & PRC PER MM. REF PNEUMATIC HEALTH CHECK, FOUND HPSOV SQUEAKING AND WORN. REMOVED AND REPLACED HPSOV.SDR UALA2012121407223Fan · malfunctionedELECTRICAL SMOKE SMELL IN COCKPIT WITH FWD EQ EXH FAN STATUS MESSAGE. FOUND AS STATED. ACRID SMELL IN E AND E DOORS OPENED AND APU CONDITIONED AIR APPLIED. FWD EXHAUST FAN CONFIRMED INOP (BURNED OUT) SUPPLY FAN OPERATION CONFIRMED NORMAL CBS COLLARED OUT PESDR UALA2012112606787O-Ring · damagedRIGHT HYDRAULIC QUANTITY EICAS. FOUND LEAK IN RT ALT BRAKE SELECTOR VLV CHANGED O-RING, NO LEAKS FOUND. OPS CHECK GOOD. SERVICED RIGHT SYSTEM BACK TO NORMAL.SDR UALA2012112006708Actuator · leakingNR 2 T-R LIFT ACTUATOR LEAKING HYD. ON AOG.SDR UALA2012111206498Switch · inoperativeRIGHT FWD FUEL BOOST PUMP PRESS LIGHT INOP. REPLACED SWITCH PER MM, OPS CHECK OKAY.SDR UALA2012101905995Slide · low pressureSLIDE 1R PRESSURE LOW. REPLACED NR 1 RIGHT MED SLIDE PER MM.SDR UALA2012101605903Control Rod · brokenNR 7 LEADING EDGE SLAT CONTROL ROD BROKEN AND PROTRUDING OUT WITH SLAT IN THE UP POSITION, FOUND ON ARRIVAL. REPLACED NR 7 L/E SLAT CONTROL ROD AND OPS CHECKED GOOD.SDR UALA2012101205821Fuel Line · leakingNR 2 ENGINE FUEL LEAK. DISCONNECTED THE NR 2 ENGINE FUEL LINE BETWEEN THE FUEL PUMP AND THE FUEL-OIL HEAT EXCHANGER DUE TO LEAK. REPLACED FUEL LINE BETWEEN FUEL PUMP PAD AND FUEL OIL HEAT EXCHANGER AS PER MM. ACCOMPLISHED LEAK CHECK AND REPAIRED LEAKING FUESDR UALA2012100505645Lug · defectiveGROUND LUG FOR NR 2 ENGINE IDG SHOW BROKEN STRANDS OF WIRE BEFORE LUG CRIMP. INSTALLED AND CRIMPED NEW LUG, HARNESS NEEDS TO BE SECURED. SECURED HARNESS.SDR UALA2012092405412Bpcu · faultyAFTER TAKEOFF LOST GALLEY POWER IN AFT ON LEFT SIDE. CYCLED UTILITY BUSES TO FIX. REPEAT WRITEUP. REMOVED AND REPLACED BPCU. OPS CHECKED NORMAL AT THIS TIME. OK TO CONTINUE FOR SERVICE IAW AMM CHP 24-41-03. NO FAULTS NOTED AT THIS TIME.SDR UALA2012091905315Floor Panel · damagedFLOOR BETWEEN SEATS 21C & 21D IS SPONGY. INTERIM REPAIR PERFORMED REF AMM. SMALL DELAMINATION REPAIR 16" X 24".SDR UALA2012091105103Panel · delaminatedNR 1 ENGINE PYLON LEFT SIDE PANEL 313T3381 JUST AFT OF ACCESS DOOR AND FORWARD OF PANEL 437DB, LOWER AFT CORNER HAS TWO DELAMINATED BUBBLES SIDE BY SIDE APPROXIMATELY 4.5 INS HIGH AND 15.5 INS LONG. PANEL WAS REMOVED, REPAIRED BY SHOP R&R #R92560. RE-INSTALLSDR UALA2012082904852Seat · unsecureROW 32 MIDDLE SEATS NOT BOLTED TO FLOOR. INSTALLED ROW 32 SEAT ASSY.SDR UALA2012082804843Liner · tornON WALK AROUND, FOUND OUTER FAN EXIT LINER AT THE 6 O'CLOCK POSITION TORN LOOSE AND STUCK IN BLOCKER DOOR ON NR 2 ENGINE. REPLACED LINER. . REPLACED ENGINE PER MM.SDR UALA2012082304740Hydraulic Line · leakingHAVE A POSSBLE NR 2 FEC. DUE TO FAN EXIT LINER SEGMENT DAMAGE, HAVE 724380-PW 564R WILL NEED CONVERSION TO 606R, ALSO RUNNING HYD LEAK. REPLACED HYD LINE.SDR UALA2012080604197Adc · malfunctionedCAPT'S ELECTRIAL ALTIMETER IS FAULTY, RETURNED TO FIELD. SELECTED ALTERNATE STATIC FIXES PROBLEM. FL340 CAPTAIN'S ALTIMETER FLUCTUATES + OR - 20 FT WHILE FIRST OFFICERS READS 34240 FT STEADY. FL280 CAPTAIN'S ALTIMETER STILL FLUCTUATES + OR - 20 FT AND FIRSSDR UALA2012080804273Chiller · vibrationCHILLER AFT GALLEY VIBRATS AND IS NOISY. REPLACED FAILED CHILLER PER AMM.