N654UA
Service difficulty reports · 382
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N654UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N654UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012080804272Chiller · failedGALLEY CHILLER INOPERATIVE AT C62. CIRCUIT BREAKER TRIPPED. REPLACED FAILED CHILLER PER AMM.SDR UALA2012071203782Cdu · inoperativeRIGHT CDU INOPERATIVE, STUCK IN MENU PAGE NO BUTTONS WORK ON RIGHT CDU. REPLACED RIGHT CDU.SDR UALA2012071103727Bracket · brokenO2 CANISTER HOLD DOWN STRAP FWD MID GALLEY RT SIDE IS BROKEN. REPLACED BRACKET AND INSTALLED CANISTER.SDR UALA2012070503596Light · intermittentCARGO FIRE DISC LIGHT IS INOPERATIVE. PERFORMED INDICATOR LIGHT TEST. DISCHARGE LIGHT ILLUMINATED, OPS AS NORMALSDR UALA2012070203527Receptacle · failedAFT F/A MICROPHONE INOPERATIVE, CONNECTOR ON ACFT BAD. REPLACED RECEPTICAL D2537 ON FLIGHT ATTENDANT PANEL, DOOR 2R. OPS NORMAL.SDR UALA2012060803129Pump · faultyRIGHT ENGINE FLAMEOUT DESCENDING THROUGH 180. RESTARTED ON ITS OWN PASSING 150. AFTER FDR INFO HAS BEEN EVALUATED, ACCOMPLISH ENGINE FLAMEOUT FIM 73-21-00. DUE TO RIGHT ENGINE FLAME OUT & R ENG FUEL VALVE LIGHT ON ACCOMPLISH FIM. ACCMP'D FIM-76-11-00 FIG 1SDR UALA2012060803122Flap System · out of adjustFLAP DISAGREE MESSAGE FLICKERING DURING FLAP 5 THROUGH FLAP 20 POSITION DURING MOVEMENT. ADJUSTED LT FLAPS IAW AMM, OPS CHECKED GOOD.SDR UALA2012060503116Structure · corrodedAFT CARGO STRUCTURE BS 1263, RBL 44 SHOWS SIGNS OF CORROSION. BLENDED OUT CORROSION, FABRICATED AND INSTALLED FILLER PER ECRA 5330-04248 AND EA PT67-53-011. ACCOMPLISHED HFEC PER NDTM 51-00-16, PRT 6 AND 51-00-19, PRT 6. NO DEFECTS NOTED.SDR UALA2012060503114Skin · damagedON LEFT SIDE OF AIRCRAFT AT STR 35L AT APPROX STA 1263 3 LOCK FASTENERS ON THE LAP JOINT STRINGER ROW HEADS ARE PULLED OR MISSING. FABRICATED AND INSTALLED FILLER, DOUBLER, TRIPLER, STRINGERS, U-CHANNELS, J-CHANNELS PER ECRA 5360-01202 AND EA PT67-53-011. ACSDR UALA2012060303067Blocker Door · crackedNR 2 ENGINE INBOARD, TR PANEL ASSY BETWEEN L5 AND L6 BLOCKER DOORS CRACKED. REPLACED NR 2 ENGINE INBOARD, TR PANEL ASSY BETWEEN L5 AND L6 BLOCKER DOORS.SDR UALA2012052702972Oxygen Mask · misinstalledALL RT PAX O2 MASKS ARE IMPROPERLY PACKED. REPACKED ALL RT PAX O2 MASKS IN REF AMM 35-21-14.SDR UALA2012052702971Oxygen Mask · misinstalledALL LT PAX O2 MASKS ARE IMPROPERLY PACKED. REPACKED ALL LT PAX O2 MASKS IAW AMM 35-21-14.SDR UALA2012052702969Oxygen Mask · misinstalledALL CENTER PAX O2 MASKS ARE IMPROPERLY PACKED. REPACKED ALL CENTER PAX 02 MASKS IN REF TO AMM.SDR UALA2012060503115Skin · dentedDENT IN SKIN MEASURES 9.7 5 INCHES BY 5.75 INCHES WITH A DEPTH 0F .149 INCH. THE \A\ OVER \Y\ = 38. THE MAX DEPTH ALLOWED IS .125 INCH. DENT INCORPORATED IN LARGER REPAIR PER ECRA 5360-01202 AND EA PT67-53-011.SDR UALA2012051802810Lap Joint · damagedON LEFT SIDE OF AIRCRAFT AT STR 35L AT APPROX STA 1263 3 EACH LOCK FASTENERS ON THE LAP JOINT STRINGER ROW HEADS ARE PULLED OR MISSING. INSTALLED 3 BLIND FASTENERS REF ECRA 5330-04239.SDR UALA2012041702311Windshield · damagedBROWN BURN MARKS ON LOWER FWD F/O WINDSHIELD R1. REPLACED WINDSHIELD PER MM, OPS CHECKS NORMAL.SDR UALA2012032201813Cover · unsecurePIGTAIL P52 GIVES ELEC SHOCK. SECURED COVER ON BACK SHELL, OPS CHECK GOOD.SDR UALA2012032201812Seal · tornCREW REPORT: UNBEARABLE HI PITCH NOISE IN COCKPIT REPEAT GRIPE. FO'S SLIDING WINDOW SEAL HAS A 1" TEAR AT THE UPPER AFT CORNER. RPLC'D SEAL. REQUIRES SEALANT APPLIED PER AMM. SEALANT TO BE APPLIED WITHIN 50 HRS. PCN FOR QUICK SETTING SEALANT IS 841-0750. SDR UALA2012022701178Hsi · malfunctionedCAPTAIN'S EHSI WENT INOP, FLIGHT DIVERTED. CREW REPORTS CAPT EHSI IS BLANK, SWITCHING INST SOURCE SELECT SW TO ALT HAS NO EFFECT. REPLACED EHSI, ALL OPS CHECKS SATISFACTORY.SDR UALA2012022000998Rvdt · misriggedT/E FLAP DISAGREE EICAS ON FLAP EXTENSION FOR LANDING. FOUND ON INITIAL EVALUATION ON FSEU M603 FLAP LEVER RVDT MISRIG SEC1 AND M548 OUTBD SLAT PDU RVDT MISSRIG, RAISED FLAPS UP ELECTRICALLY, CHECKED NR 2 OUTBD SLATS PDU INDICATOR ALL NORMAL AS PER MM. PERFOSDR UALA2012022101059Valve · faultyEICAS MESSAGE FOR COCKPIT TEMP DISPLAYED AND COCKPIT TEMP INOPERATIVE LIGHT ILLUMINATED IN AUTO. MANUAL OPERATION NORM. FOUND COCKPIT TRIM AIR VALVE SLOW TO MOVE. REPLACED TRIM AIR VALVE.SDR UALA2012022101058Controller · inoperativeCOCKPIT AUTO TEMPERATURE CONTROL INOPERATIVE, WORKS IN MANUAL. FOUND CABIN TEMP CONTROLLER FAILED BITE. REPLACED CONTROLLER AS PER AMM. ALL OPS NORMAL, BITE TEST AND OPS CHECKED OKAY.SDR UALA2012020600688Feeder Cable · damagedCLEANERS VACUUMED UP PORTION OF EEL LIGHTING AFT OF DOOR 1L. REPLACED FEEDER CABLE. GROUND CHECKS NORMAL.SDR UALA2012010400100Shutoff Valve · failedRAN NR 2 ENGINE AT IDLE. NR 2 BLEED SLOW TO RISE TO 34 PSI AND WHEN THERE IS A DEMAND (IE. PACK OR ADP) BLEED DROPS TO 5 PSI. ONCE DESELECTING DEMAND IT GOES BACK TO 34 PSI. REMOVED PRSOV MR36159-146, REPLACED NR 2 PRSOV PER MM, OPS CHECKED GOOD.SDR UALA2011121906972Anti-Ice Valve · malfunctionedRIGHT ENG ANTI ICE ILLUMINATED. FOLLOWED CHKLIST KEPT VALVE OPEN PER QRH. SAMC TEXT: PER CREW COMMENT THE RT ENG ANTI ICE VLV IS STUCK IN THE OPEN POSITION. RT ENG ANTI ICE VLV CHK FOR FREE MOVEMENT, ALL NORMAL. ELECTR CONNECTOR CLEANED. FOR REF USED SERSDR UALA2011121206790Priority Valve · faultedCREW REPORTED NO RT HIGH STAGE BLEED AT 80 PERCENT N1. RT BLEED DUCT OSCILATES BETWEEN 20-40 PSI DURING CLIMB. IN DESCENT RT DUCT 20 PSI LESS THAN LEFT. VALVE IN LOCKED IN INTERMEDIATE POSITION. FAULTING FAN AIR TEMP SENSOR. ON TAKEOFF AND CLIMBOUT RIGHT DSDR UALA2011120906773Controller · faultedRIGHT BLEED DUCT OSCILLATES B-W 20-40 PSI DURING CLIMB. IN DESCENT RT DUCT 20 PSI LESS THAN LEFT. VALVE IN LOCKED INTERMEDIATE POSITION. FAULTING FAN AIR TEMP SENSOR. ON TAKEOFF AND CLIMBOUT RIGHT DUCT PRESSURE RAPIDLY FLUCTUATED BETWEEN 20 AND 40 PSI, PER CSDR UALA2011120906767Controller · faultyFWD CABIN TEMP EICAS DISPLAYED. NO FAULTS ON GRD, BITE OKAY. REPLACED ZONE TEMP CONTROLLER PER MM, BITE OK. ALSO CLEANED FWD ZONE TEMP SENSOR.SDR UALA2011120806748Valve · faultyRIGHT DUCT PSI FLUCTUATES +-25 PSI ON CLIMB & DESCENT. ACCOMPLISHED AIR SUPPLY BITE MODULE PROC PER MM. RIGHT PRV FAULT INDICATED. REPLACED NR 2 ENG PRV PER MM & ACCOMPLISHED GRD RUN PER JRH, ALL OPS & INDS NOW NORMAL. AIR SUPPLY MODULE BITE PROC.SDR UALA2011111406235Floor Panel · delaminatedRIGHT AISLE AT WING EXT FLOOR SOFT. PANEL DELAMINATION FOUND AT SEAT ROW 21KJ RT AISLE. DELAMINATED AREA IS APPROX ONE FOOT BY ONE FOOT. INTERIM REPAIR PERFORMED PER AMM.SDR UALA2011101805637Unknown · smokeCAPTAIN NOTICED WHITE SMOKE OUTSIDE OF SLIDING WINDOW. INSPECTED WINDOWS FOR ANY DELAM OR DISCOLOR, OPENED RADOME, WALKED THROUGH E/E TUNNELS NO EVIDENCE FOUND OF SMOKE OR DAMAGE. NO PRIOR AMIS HISTORY. WINDOW HEAT TEST OKAY.SDR UALA2011101005484Switch · intermittentCAPTAIN'S PUSH TO TALK ON COMM PANEL & PTT ON CAPTAIN'S GLARESHIELD PANEL ARE INTERMITTENT. REPLACED CAPTAIN'S AND SPARE MINITEL, OPS CHECKED OKAY.SDR UALA2011100305356Coupling · tornFOUND WATER POURING OUT OF DRAIN BILGE PORT JUST FORWARD OF WASTE SERVICE PANEL. FOUND DRAIN COUPLING ASSY TORN. REPAIRED DRAIN COUPLING, LEAK CHECKED GOOD.SDR UALA2011092105106Control Panel · inoperativeTHE 2ND OBS AUDIO CONTROL PANEL HAS INOPERATIVE INTERPHONE FUNCTION. REPLACED AUDIO CONTROL PANEL.SDR UALA2011091905054Control Panel · stuckCAP RADIO 1 PANEL PTT BUTTON ON LOWER PANEL OR SIDE PANEL CAUSED STUCK MIC IN LHR. REPLACED NR 1 RADIO CONTROL PANEL, OPS CHECK NORMAL.SDR UALA2011082304525Ballast · faultyF/A'S REPORT BURNING ELECTRICAL ODOR IN AFT GALLEY ON PUSHBACK. FOUND AFT CEILING LIGHTS L227 & L230 INOP. BALLAST M665 CAUSE OF SMELL. FOUND AFT RT LAV SMOKE DETECTOR BURNT. REPLACED DETECTOR. CHECKED ALL WIRES AT CONN D2864 FOR M665 BALLAST & FOUND NO PSDR UALA2011081504310Processor · faultyFUEL QUANT INDIC AND RFUEL TANK INDIC BOTH WENT BLANK ON TAXI-OUT. REPLACED FUEL QUANTITY PROCESSOR, OPS CHECK GOOD.SDR UALA2011080504085Nozzle · obstructedFIRE EXT NOZZLE PARTIALLY COVERED WITH PIT TAPE. AFT NOZZLE IN AFT PIT. TAPE PARTIALLY BLOCKING NOZZLE TRIMMED PER MM, OTHER NOZZLES CHECKED IN FWD, AFT & BULK PITS. ALL OKAY.SDR UALA2011080304041Switch · faultySTANDBY POWER SWT ON OVERHEAD PANEL DOES NOT HAVE DETENT FROM AUTO TO OFF. INSTALLED SWITCH, TESTED STNDBY PANEL ACCORDING TO AMM. SWITCH PCN (586-2220) PN 3600-5478. NO TAG ATTACHED ACCORDING SAMC.SDR UALA2011071303542Pump · out of tolerancePER SW2304 FOUND LEFT FWD FUEL PUMP OUT OF TOLERANCE. REPLACED FUEL PUMP PR MM. TESTED AND LEAK CHECKED OKAY.SDR UALA2011071103445Pump · leakingEVIDENCE OF HYD LEAK FROM RT MAIN WHEEL WELL LOWER CTR LINE. FOUND THE CTR ELEC HYD PUMP 1 LEAKING. REMOVED CTR PUMP 1 PER MM. REPLACED C1 PUMP PER MM. NO LEAKS.SDR UALA2011070103266Actuator · defectiveCREW REPORT: C HYD SYS MAINT MSG. ELECT C1 PUMP PRESSURE IS 2690 PSI, C2 ELECT PUMP PRESSURE IS 2410 AND ADP PRESSURE IS 2990 PSI. REPLACED CENTER HYD PRESS TRANSMITTER, NO HELP. WITH CENTER WING HYD SHUTOFF VALVE OFF, ELEC HYD PRESSURES RETURNED TO ABOVE SDR UALA2011070103265Actuator · defectiveLEFT INBD AILERON INBD ACT REQUIRES REPLACEMENT. INSTALLED NEW ACTUATOR PER MM. SYSTEM WITHIN TOLERANCE.SDR UALA2011062003026Control Panel · faultyAUTOLAND NO LAND 3 ILLUM CB E34 POPPED. REPLACED AFCS MODE CONTROL PANEL PER MM.SDR UALA2011053102660Pump · inoperativeRIGHT AFT BOOST PUMP CIRCUIT BREAKER FOUND POPPED. MADE INOPERATIVE PUMP PER MEL 2822N. REPLACED RT AFT BOOST PUMP REF MM, TESTS OKAY.SDR UALA2011052502553Generator · crackedAPU OIL QTY STATUS MESSAGE SAMC TEXT: BRUMM SERVICED APU AND FOUND OIL LEAK FROM CRACK IN APU GENERATOR HOUSING. REPLACED APU GENERATOR IAW AMM.SDR UALA2011052402531Unknown · leakingCREW REPORT: APU OIL QTY STATUS MESSAGE. SUPPLEMENTAL DATA UPDATESDR UALA2011050302175Oxygen Mask · leakingCAPTAIN'S OXYGEN MASK LEAKING. REPLACED CAPT O2 MASK.SDR UALA2011040401607Light · shortedEEL LIGHTING AT SEATS 8AB THRU 14AB INOPERATIVE. FOUND LIGHT ASSY SHORTED AT SEAT 8AB, REPLACED SAME, OP CHECKS NORMAL.SDR UALA2011030701111Union · leakingNR 2 ENG HAS HEAVY COKING ON VSV UNISON RINGS AT TOP OF ENGINE FROM FLUID LEAK AT PYLON. REMOVED & REPLACED NR 2 ENGINE.