N657AE
Service difficulty reports · 220
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N657AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N657AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2021091300462Seat Track · corrodedRH OUTBD SEAT TRACK SUPPORT IS CORRODED AT FR 46. PERFORMED REPAIR OF SEAT TRACK SUPPORT AT FR 46 IAW EMB 145 SRM 53-00-11 REPAIR TYPE C.SDR HNAA2021091300461Floor Support · corrodedRH OUTBD FLOOR SILL #4 IS PITTED. REMOVED AND REPLACED RH OUTBD FLOOR SILL #4 IAW EMB 145 SRM 51-40-02.SDR HNAA2021091300460Floor Support · corrodedRH OUTBD FLOOR SILL #3 IS PITTED. REMOVED AND REPLACED RH CABIN FLOOR SILL #3 IAW EMB-145 SRM 51-40-02.SDR HNAA2021091300459Door Sill · corrodedCARGO DOOR CUTOUT LWR SILL IS CORRODED IN MULTIPLE AREAS. REMOVED AND INSTALLED SERVICEABLE CARGO DOOR CUT OUT LOWER CENTER SILL IAW EMB 145 SRM 51-40-02.SDR HNAA2021091300458Floor Support · corrodedLAV LH CENTER FLOOR GUSSET IS CORRODED AT FWD AND AFT SCREW HOLES. REMOVED CORRODED AND INSTALLED NEW L/H LAV CENTER BEAM GUSSET IAW EMB 145 SRM 51-40-02.SDR HNAA2021091300457Floor Support · corrodedLAV CENTER FLOOR GUSSET IS CORRODED AT AFT SCREW HOLE.(PREVIOUS BLEND) REMOVED CORRODED AND INSTALLED NEW LAV CENTER FLOOR GUSSET IAW EMB 145 SRM 51-40-02.SDR HNAA2021091300456Floor Support · corrodedLAV RH CENTER FLOOR GUSSET IS CORRODED AROUND 3 SCREW HOLES. REMOVED CORRODED CENTER RH LAV GUSSET AND INSTALLED SERVICEABLE GUSSET IAW EMB 145 SRM 51-40-02.SDR HNAA2021091300449Gusset · corrodedCENTER OMEGA BEAM GUSSET #3 IS PITTED. REMOVED AND REPLACED CENTER OMEGA BEAM GUSSET #3 IAW EMB145 SRM 51-40-02.SDR HNAA2021091300448Floor Support · corrodedRH OUTBD FLOOR SILL #1 IS PITTED. REMOVED AND REPLACED RH #1 OUTBD FLOOR SILL AS REQUIRED IAW EMB 145 SRM 51-40-02.SDR HNAA2021091300447Floor Support · corrodedLH OUTBD FLOOR SILL #3 IS PITTED. REMOVED AND INSTALLED NEW LH OUTBD FLOOR SILL #3 IAW EMB 145 SRM 51-40-02.SDR HNAA2021091300446Floor Support · corrodedLH OUTBD FLOOR SILL #2 IS PITTED. REMOVED AND REPLACED LH OUTBD FLOOR SILL #2 IAW EMB145 SRM 51-40-02.SDR HNAA2021091300445Floor Support · corrodedLH OUTBD FLOOR SILL #4 IS PITTED. REMOVED AND INSTALLED NEW AND SERVICEABLE LH OUTBD FLOOR SILL #4 IAW EMB145 SRM 51-40-02.SDR HNAA2021091300444Floor Support · corrodedRH OUTBOARD FLOOR SILL #2 IS PITTED. REMOVED AND INSTALLED NEW SERVICEABLE OUTBOARD FLOOR SILL #2 IAW EMB145 SRM 51-40-02.SDR HNAA2021091300467Rib · crackedRH WING RIB 21 IS CRACKED INSIDE PANEL 651CB. INSTALLED DOUBLER, FILLER AND SHIM FOR REPAIR OF RH WING RIB 21 INSIDE PANEL 651CB IAW EMB145 SRM 57-20-07RE, ITEM 4, FIG 203 AND PIEDMONT EO1-57-21-0233.SDR HNAA2021051200201Handle · out of positionMAIN CABIN DOOR WILL NOT OPEN FROM THE INSIDE. FOUND PAX DOOR HANDLE INCORRECTLY POSITIONED. REMOVED HANDLE AND RE INSTALLED IN CORRECT POSITION PER AMM 52-18-05. OPS CHECK GOOD. OK FOR SERVICESDR HNAA2021041300141Smoke Detector · false activationLAV SMOKE EICAS MSG DISPLAYED IN FLT. PERFORMED INSPECTION OF LAV SMOKE DETECTOR. NO DEFECTS NOTED. C/W LAV SMOKE DETECTION SYSTEM IAW 26-14-00. SYS OPS NORMAL. OK FOR SERVICE. SUSPECT VAPING IN LAVSDR HNAA2019111400354Light · inoperativeRH OVER WING EMERGENCY LIGHT INOP....FIX: R&RD RH OVER WING EMERGENCY LIGHT IAW 33-50-10-000/400-801-A.OPS CHECK GOODSDR HNAA2019110400340Engine · leakingMDIS 657 72-13 2081341 02NOV19 CLT ASSGN
OIL LEAK #2 ENG AFT END NEAR DIFFUSER. FIRE IN EXHAU
ST FOR 1 TO 2 MINUTES
26631 00 EK
ENGINE CHANGE IS CURRENTLY IN PROGRESS FIX: R&RD #2 ENGINE IAWSDR HNAA2019101900311Bulb · inoperativeR/H AFT EMERGENCY EGRESS LIGHT INOP....FIX: REMOVED LENS REPLACED BULB, INSTALLED LENSSDR HNAA2019091300270Warning System · malfunctionedPDIS 657 31-50 2067831 11SEP19 PHL ASSGN CAPT CAUTION LIGHT DOES NOT EXTINGUISH. MEL 11SEP19 21:28 PHL C25422 31-7-1
MASTER CAUTION LIGHTS.SDR HNAA2019062400182Unknown · odorFA/PASSENGERS CALLED COCKPIT FOR BURNING SMELL IN CABIN ON TAXI. NO SMOKE NOTED. CAPTAIN AND FO SMELLED BURNING IN FLT DECK, NO SMOKE NOTED. RAN QRH PROCEDURE, GOT A/C IN SAFE STATE. RAN BOTH PACKS OF APU AND ENGINE BLEEDS, CHECKED FOR SMELLS AND SMOKE, NONESDR HNAA2019041100093Extinguisher · leaking657 26-15 1935221 10APR19 ROC CLOSE
BAGBAY EXT. BOTTLE INOP EICAS MESSAGE DISPLAYED. DISCOVERED HALON LEAKING IN BAGBAY.
10APR19 16:11 ROC C10009 26-8
BAG BAY FIRE EXTINGUISHER
FACT 11APR19 02:37 PHL
R&R BAGGSDR HNAA2018121800320Clamp · loosePDIS 657 21-11 1915522 16DEC18 PHL CLOSE
AFTER TAKEOFF BLD 1 LEAK EICAS MSG ALONG WITH RED INSCRIPTION ON BLEED SWITCH. AFTER QRH, MESSAGES EXTINGUISHED. HISTORY: YES
FACT 16DEC18 14:35 PHL
INSPECTED ENGINE 1 BLEED VALVE AND FSDR SIMA2018121030005Skin · crackedRH EXTERNAL FUSELAGE SKIN CRACKED AROUND 2 RIVETS FR 78-C/A-RH EXTERNAL FUSELAGE SKIN CRACKED AROUND 2 RIVETS FR 78 REPAIRED IAW ERS-EM-53MR-3518SDR SIMA2018121029004Wire · broken#4 FLOOR EMERGENCY LITE STRIP HAS BROKEN WIRE-C/A-RAR #4 EMERGENCY LITE STRIP IAW EMB 145 AMM 33-50-12 OCK GOODSDR SIMA201812108007Connector · brokenFR20 FLOOR PROXIMITY LIGHT #1 WIRES BROKEN CONNECTORS-C/A-REPAIRED FR 20 FLOOR PROXIMITY LIGHT #1 WIRES IAW EMB 145 SWPM 20-21-00. FOUND DURING OPEN UP.SDR SIMA2018121070003Connector · missingEMERGENCY LIGHT STRIP #8 CONNECTOR AT FLOOR PANEL 261BF MISSING (AIRCRAFT SIDE)-C/A-INSTALLED MISSING CONNECTORS AT FLOOR PANEL 261BF (AIRCRAFT SIDE) SP9212 WIRE W192-8832-22 AND SP9213 WIRE W192-8833-22 IAW EMB 145 SWPM 20-50-00SDR SIMA2018121050002Door Sill · corrodedCENTER SERVICE DOOR SILL CORRODED AROUND FWD AND AFT NUTPLATE HOLES-C/A-REMOVED AND REPLACED SERVICE DOOR CUTOUT LOWER CENTER SILL IAW EMB145 SRM 51-40-02SDR SIMA2018121040002Frame · crackedFRAME 73 IS CRACKED BETWEEN STRINGERS 16R - 17R-C/A-REMOVED AND REPLACED FRAME 73 (LOWER FRAME) IAW EMB 145 SRM 51-40-02SDR SIMA2018121030006Floor Support · corrodedLH OMEGA BEAM IS CORRODED AT CROSSBEAM FR-29-C/A-REPAIRED LH OMEGA BEAM CORROSION AT FRAME 29 IAW ERS-EM-53MR-3510.SDR SIMA2018121000004Skin · crackedBAGGAGE DOOR EXTERNAL SKIN IS CRACKED NEAR HANDLE-C/A-PERFORMED PERMANENT REPAIR ON BAGGAGE DOOR IAW ENVOY ERS-EM-52MR-928SDR SIMA2018121020005Skin · damagedNUTPLATE ON RUDDER II LH SIDE ELONGATED HOLES-C/A-ACCOMPLISHED PERMANENT REPAIR OF RUDDER II BOTTOM LH SIDE SKIN IAW ERS-EM-55MR-717SDR SIMA2018121019004Profile · corrodedCORROSION ON BAGGAGE DOOR LOWER INTERNAL PROFILE BRACKET AT PREVIOUS REPAIR-C/A-REMOVED AND REPLACED BAGGAGE DOOR LOWER PROFILE IAW EMB 145 SRM 51-40-02SDR SIMA2018121016007Mount · crackedRH ENGINE PYLON FWD LOWER YOKE CRACKED-C/A-REMOVED AND REPLACED RH FWD LOWER YOKE IAW EO EM-54MR-698SDR SIMA2018121015004Hinge Fitting · wornRH ELEVATOR SPRING TAB CENTER HINGE FITTING WORN-C/A-REMOVED AND REPLACED RH ELEVATOR SPRING TAB CENTER HINGE SUPPORT IAW EMB 145 AMM 55-22-01 AND ENVOY ETN-EM-55-086SDR SIMA2018121106009Skin · crackedR/H EXTERNAL FUSELAGE SKIN CRACKED AROUND RIVET FR-77 MARKED-C/A-COMPLETE:REPAIRED SKIN CRACK AT 1 LOCATION ON T HE RH EXTERNAL FUSELAGE SKIN AT FR77 IAW EMB 145 SRM 53-32-01 (ITEM 9) AND ETN-EM-53-194R1 AND ETN-EM-53-276R2. SEE TURNOVER FOR DETAILSSDR SIMA2018121106008Skin · crackedR/H EXTERNAL FUSELAGE SKIN CRACKED AROUND RIVET FR-79 MARKED-C/A-COMPLETE:REPAIRED SKIN CRACK AT 1 LOCATION ON THE RH EXTERNAL FUSELAGE SKIN AT FR79 IAW EMB 145 SRM 53-32-01 (ITEM 9) AND ETN-EM-53-194R1 AND ETN-EM-53-276R2. SEE TURNOVER FOR DETAILSSDR SIMA2018121106007Escape Rope · frayedPILOTS ESCAPE ROPE FRAYED.-C/A-COMPLETE:REMOVED AND REPLACED PILOTS ESCAPE ROPE IAW EMB 145 AMM 25-60-07.SDR SIMA201812106006Light · inoperativeLH PASSENGER ESCAPE HATCH LINING LOWER EMERGENCY LIGHT INOP.-C/A-COMPLETE:REMOVED CONNECTED AND REINSTALED LH PASSENGER ESCAPE HATCH LINING LOWER EMERGENCY LIGHT OP CK CW IAW EMB 145 AMM 33-50-13SDR SIMA201812106005Bulb · inoperativeEMERGENCY LIGHT ON SERVICE DOOR INOP-C/A-COMPLETE:REMOVED AND REPLACED SERVICE DOOR EMERGENCY LIGHT BULB IAW EMB 145 AMM 33-50-09. ILLUMINATION CHECK GOOD.SDR SIMA201811086002Bolt · unsecureUPON GATE ARRIVAL UNABLE TO OPEN MAIN PAX DOOR FROM INSIDE. HAD TO BE OPEN FROM OUTSIDE.-C/A-RE SECURED DOOR HANDLE ATTACH BOLT AN OPERATED DOOR SEVERAL TIMES FROM INSIDE. IAW EMB145 AMM52-18-05. REF AML LOG 4442071 ITEM 2 FOR FUNCTIONAL TEST. PERFORMED MAIN CSDR SIMA2018062019002A/C Pack · malfunctionedCLIMBING THROUGH FL220, CREW RECEIVED PACK 1 & 2 FAIL MESSAGES AND NOTED THE CABIN ALTITUDE WAS 10,000 FT. AND CLIMBING. DECLARED AN EMERGENCY, BEGAN A DESCENT. CREW WAS ABLE TO RESET THE PACKS AND PRESSURIZATION RETURNED TO NORMAL. CREW CONTINUED TO DESTSDR SIMA201805295001Lamp · inoperativeROW 16 CEILING EMERGENCY LIGHT WAS INOPERATIVE. R & R THE LAMP IAW AMM 33-50-08. OPS CHECKED GOOD.SDR SIMA2018052118001Flashlight · inoperativeFWD FA FLASHLIGHT INOPERATIVE. R & R THE FWD FA FLASHLIGHT, OPS CHECKED GOOD IAW AMM 33-50-16.SDR SIMA201805140002Handle · unsecureMAIN ENTRY DOOR UNABLE TO OPEN WITH DOOR HANDLE, DOOR HANDLE NOT SECURE. SECURED THE DOOR HANDLE IAW AMM 52-10-01, OPS CHECKED GOOD, NO DEFECT NOTED.SDR SIMA2018051501001Pneumatic System · leakingBLEED 1 LEAK DURING DEPARTURE, RAN QRH, MESSAGE DID NOT EXTINGUISH AND RETURNED TO DEPARTURE. EMERGENCY DECLARED. PERFORMED OPC OF E1 BLEED AIR SYSTEM AS PER EMB145 AMM 36-00-00. OPS CHECKED GOOD. PERFORMED LEAKAGE TEST OF LT AIR BLEED SYSTEM DUCTS IAW AMM 3SDR SIMA20171219002Light · inoperativeDURING PS-1 FOUND EMER PATH LIGHTING STRIP BETWEEN ROWS 5 AND 7 INOP. R&R FLOOR PROXIMITY STRIP LIGHT IAW AMM 33-50-12, OPS CHECK GOOD.SDR SIMA20171218002Light · inoperativeEMERGENCY LIGHT AT ROW 6 - 7A INOPERATIVE.SDR SIMA20171004003Bulb · inoperativeEMERGENCY LIGHTS AT MAIN ENTRANCE AND GALLEY INOPERATIVE. R & R THE BULBS IAW AMM 33-50-06, AND 33-50-09. OPS CHECKED GOOD.SDR SIMA20171004002Light · inoperativeRIGHT OVERWING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE EXTERNAL EMERGENCY LIGHT ASSY IAW AMM 33-50-10. OPS CHECKED GOOD.
Back to N657AE