N659AE
Service difficulty reports · 177
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N659AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N659AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2022052600210Floor Support · corrodedE914351 - RH #6 OTBD FLOOR SILL HAS PITTING .... REMOVED AND REPLACED RH #6 MOTBD FLOOR SILL IAW EMB145 SRM 51-40-02.SDR HNAA2022052600208Floor Support · corrodedE914349 - LH #6 OTBD FLOOR SILL HAS PITTING .... REMOVED AND REPLACED LH #6 OTBD FLOOR SILL IAW EMB145 SRM 51-40-02.SDR HNAA2022052600207Floor Support · corrodedE914332 - RH #3 OTBD FLOOR SILL HAS PITTING. R & R RH #3 OTBD FLOOR SILL IAW EMB145 SRM 51-40-02.SDR HNAA2022052600209Floor Support · corrodedE914350 - LH #7 OTBD FLOOR SILL HAS PITTING .... REMOVED AND REPLACED LH #7 OTBD FLOOR SILL IAW EMB145 SRM 51-40-02.SDR HNAA2022052600205None · noneE913854 - FR 72 IS CRACKED BTW STR 17L-16L ....REPAIRED FR 72 CRACK BETWEEN STR 17L-16L IAW PIEDMONT EO1-53-22-0093.SDR HNAA2022052600211Floor Support · corrodedE914503 - GALLEY LH INBD SEAT TRACK #1 IS CORRODED .... RAR GALLEY LH INBD SEAT TRACK #1 IAW EMB 145 AMM 53-01-06SDR HNAA2022031600124None · nonePDIS 659 29-13 2671141 13MAR22 DAY CLOSE
HYD 2 LO QTY MSG ON EICAS IN FLIGHT, CREW FOUND SOME POSSIBLE HYD LEAK UNDER #2 ENGINE LOWER COWLING.
FACT 14MAR22 12:54 DAY
LEAK UNDER NO2 ENG IS ANTI ICE FLUID. DISCOVERED BOTH RUDDSDR HNAA2021112900565None · nonePDIS 659 36-11 2572481 18NOV21 PHL CLOSE
BLD 2 LOW TEMP DISPLAYED ON DESENT WITH N2 ABOVE 86 PERCENT.
FACT 19NOV21 16:03 PHL
CMC MESSEGE PRECOOLER 2 TEMP CTL FAIL.R/R FAN AIR CONT THERMOSTAT.REQUIRES OPS CHECK.REF AMM 36-11-06.SDR HNAA2021112900564None · nonePDIS 659 30-10 2572473 18NOV21 PHL CLOSE
WING A/I FAIL DISPLAYED IN AND OUT OF ICING CONDITIONS.
FACT 19NOV21 16:10 PHL
R/R CLAMPS OPS/LEAK CHECK FAIL.STILL LEAKING. FOUND ANOTHER COUPLING LEAKING SAME AREA. TRANSCRIBED TO HA-3SDR HNAA2021112900563None · nonePDIS 659 30-10 2572471 18NOV21 ALB CLOSE
WING A/I FAIL ON EICAS WHEN ENTERING ICING CONDITIONS. FOLLOWED QRH (TURN OFF WG A/I) WITH WING 1&2 A/I VLV FAIL AND WING 2 A/I LEAK
FACT 18NOV21 18:32 ALB
FOUND SPLICE AT #2 WING THERMOSDR HNAA2021090700443Bulb · smokeDURING TAKEOFF BETWEEN 400-2000FT FUMES SMELL IN COCKPIT AND FWD CABIN. SEE LP 249922-2 AND 249923-1 FOR TROUBLESHOOTING AND ENGINE RUNS. WHILE TROUBLESHOOTING, FOUND GALLEY COURTESY LIGHT BULB TO BE SMOKING WHILE OPERATING. R+R'D LIGHT BULB. NEW BULB OPERATESSDR HNAA2021090700442Fuse · overheatedON DESCENT FROM 19K - 10K FT BURNING SMELL IN COCKPIT AND CABIN APPEARED 3 TIMES WITH BOTH BLEEDS AND PACKS RUNNING AND APU OFF. RAN BOTH ENGINE BLEED AND PACKS. NO DEFECTS NOTED. SEE ALSO W/C 36-10-03 FOR OTHER MX DONE. INSPECTED R/H+L/H ELECTRICAL DIST BUS PSDR HNAA2021081000355Sleeve · failedWING AI FAIL MSG DURING AI TEST IN FLT (TWICE) W NO OPEN INSCRIPTION AND NOT IN ICING CONDITIONS. R&R FLEX SLEEVE ON #1 WING A/ICE DUCT IAW AMM 30-11-01. REQUIRES OPERATIONAL CHECK. OPS CHECK ANTI ICE SYSTEM IAW AMM 30-00-00 OPS CHECK GOOD. OK FOR SERVICE.SDR HNAA2021060100228A/C Pack · odorDURING CRUISE FLT AT 25000FT STRONG BURNING PLASTIC SMELL IN COCKPIT FOLLOWED SHORTLY IN CABIN. FOLLOWED QRH AND SMELL MITIGATED BUT REMAINED UNTIL ON GROUND. NO SMOKE NOTED. INSPECTED PACK SYSTEMS FOR BURNING SMELL. MX FOUND BURNING SMELL IS FROSDR HNAA2021030700088Warning Message · false activationSPS 1 INOP ON TAKEOFF ROLL. CMC MSG OF SPC FAIL. CMC MSG SPC FAIL FOLLOWED FIM 27-36-00-810-807-A BLOCK 1 OPS CHECK AMM 27-36-00-700-801-A SPS OPS CHECK GOOD FOUND TO BE TRANSITORY CONDITION. OK FOR SERVICE.SDR HNAA2021011100009A/C Pack · overheatedPACK 2 OVERHEAT WITH STRONG BURNING SMELL WHEN THRUST LEVERS AT HIGH SETTING. C/W FIM TASK 21-51-00-810-804-A BLOCK 2 RESULT IN NO PACK 2 OVERHEAT EICAS MESSAGE. NO RESULT BLOCK II TRANSITORY CONDITION OF AIR CONDITIONING SYSTEM. FOUND WON AND LEAKING SLEEVSDR HNAA2020092100257Lever · bindingPDIS 659 32-30 2423781 19SEP20 CLT CLOSE IN FLIGHT, LANDING GEAR LEVER WAS JAMMED AND WOULD NOT RAISE FACT 19SEP20 17:03 CLT. R & R RELAY K0024. PERFORMED OPS CHECK OF LANDING GEAR LEVER, IAW AMM 32-32-00-700-802-A. OPS CHECK GOOD. OK FOR SERVICE.SDR HNAA2020030400086Light · inoperativeLH SIDE OVERWING EMERGENCY LIGHT INOP....FIX: R&RD EMERGENCY LIGHT ON LHS IN REF TO AMM 33-50-10-000/400-801-A. OPS CHECK GOOD.OK FOR SERVICE.SDR HNAA2020010600002Warning Message · false activationPDIS 659 32-41 2242582 02JAN20 CLT CLOSE
MULTIPLE BRAKE DEGRADED MSG DURING TAXI
DFRL 04JAN20 00:13 MDT
TRANSCRIBED TO HA300 SEQ 5 ON WORK PACKAGE DATED
01/03/2020.///CHECKED WIRES @ P3718 CANNON PLUG PIN 23 TO 24,78 TO SDR HNAA2019120900379Filter · dirtyREJECTED TAKEOFF DUE TO BLD 2 OVTEMP WARNING. FOLLOWED BY PACK 2 OVERHEAT. MX PERFORMED C/W VISUAL INSPECTION OF PRE COOLER LINE REGION. NO DISCONNECTED OR DAMAGED COMPONENTS. CLEANED FAN VALVE FILTER AND C/W OPS CHECK I/A/W M/M 36-11-03 AND TASK 36-00-00-700-SDR HNAA2019111100352Unknown · smokePDIS 659 05-50 2243021 10NOV19 CLT CLOSE
TOW TEAM REPORTED SMOKE IN COCKPIT DURING TOW.
25722 00 VAG
HISTORY: NONE
FACT 10NOV19 13:58 CLT
OPS CK APU BLEEDS RAN HYD PUMP FOR SSDR HNAA2019080600209Light · inoperativeRH AND LH OVERWING PANEL EMERGENCY LIGHTS DO NOT COME ON....FIX: R&RD LH & RH EXTERNAL EMERGENCY LIGHT ASSY,S AND OPS CHECK GOOD IAW EMB AMM 33-50-10SDR HNAA2019080200208Web · damagedCARGO DOOR INNER WEBBING IS GOUGED IN 5 AREAS. REPAIRED IAW EO1-52-19-0300 AND 3 AREAS TO BE WITH-IN LIMITS OF SRM 52-30-01 TABLE 104SDR HNAA2019080200207Web · damagedCARGO DOOR INNER WEBBING IS CORRODED AROUND 6 SCREW HOLES AND NUMEROUS SCREW HOLES HAVE PRIMER DAMAGE. ONE AREA REPAIRED IAW PIEDMONT EO1-52-19-0299 THE OTHER FIVE AREAS WERE FOUND TO BE WITH-IN LIMITS OF EMB145 SRM 52-30-01 TABLE 104.SDR HNAA2019061800174Wire · brokenTHE SERVICE DOOR EMERGENCY EXIT LIGHT IS INOP. INVESTIGATION FOUND WIRE W716-0007-20 BROKEN. REPAIRED WIRE, OPS CHECK GOODSDR HNAA2019061100170Bleed Valve · inoperativeBLEED 1 VALVE FAIL MESSAGE WITH ASSOCIATED WING AND STAB ANTI-ICE MESSAGE. R & R THE NR 1 ENG BLEED VALVE IAW AMM TASK 36-11-05-000/4-00-801-A, OPS CHECK GOOD, NO BLEED FAIL MESSAGES OR LEAK MESSAGES,OK FOR SERVICESDR HNAA2019050200137Warning System · false activationPDIS 659 30-10 1922203 03MAY19 GRR CLOSE ON TAKEOFF ROLL MASTER WARNING OF ICE COND ANTI ICE FAIL. CMC MESSAGE OF WG 2 ANTI ICE LEAK. FACT 03MAY19 21:53 GRR C/W FIM TASK 30-11-00-810-807-A FOUND NO DEFECTS, PERFORMED OPS CHECK IAW AMM 30-00-00-05 OSDR HNAA201812310032Flashlight · odorPDIS 659 25-60 1868881 28DEC18 PHL CLOSE
COCKPIT FLASHLIGHT ASSY HAS A HOT ELECTRICAL SMELL.
FACT 28DEC18 08:28 PHL
REPLACED FLASHLIGHT ASSY IN COCKPIT. OPS CHECK GOOD.
OK FOR SERVICESDR HNAA2018122100327Bulb · malfunctionedR/H FWD FUSELAGE EMERGENCY LIGHT DIM. R/R BULB IAW AMM 33-50-10-400-801-ASDR HNAA2018071800151Hydraulic System · contaminatedBRAKE DEGRADED EICAS CAUTION MESSAGE DISPLAYED WHILE TAXIING. RETURNED TO GATE AND NR 1 HYD FLUID DOWN 25 PERCENT. BLED AIR FROM NR 1 AND NR 2 HYD SYSTEMS IAW AMM 29-10-00-803-A. PRESSURIZED HYD SYSTEM IAW AMM 29-10-00-860-801-A. OPS CHECK GOOD. NO LEAKS NOTEDSDR HNAA2018070600134Fuse · blownEMERGENCY LIGHT ON PAX DOOR INOP. REMOVED EMERGENCY BATTERY ASSY AND BOUGHT TO SHOP TO CHECK. FOUND NR 2 LIGHT CIRCUIT INOP. R&R F2 PICO FUSE. RE-INSTALLED BATTERY ASSY WITH RETAINED HARDWARE, PERFORMED SELF TEST ON THE BATTERY ASSY, SELF TEST GOOD.SDR HNAA2018070600132Battery · dischargedEMERGENCY LIGHT AT LT EMERGENCY DOOR INOP. INSTALLED EMERGENCY BATTERY ASSY 3 AND RE SECURED WITH RETAINED HARDWARE.SDR HNAA2018021400029Warning Message · false activationEMERGENCY LIGHTS NOT ARMED CAUTION MESSAGE, DISPLAYED RANDOMLY 4 - 5 TIMES ON EICAS, SWITCH WAS VERIFIED TO BE IN THE ARMED POSITION. OPS CHECKED THE EMERGENCY LIGHTING SYSTEM, FOUND GOOD AT THIS TIME IAW 33-50-00. NO ERRONEOUS MESSAGES NOTED. OK FOR SERVICESDR HNAA2018021400028Unknown · multiple failAT APPROXIMATELY 500 FT, THE AUTOPILOT WAS SELECTED ON, ONLY YAW DAMPER ENGAGED, LANDING GEAR AIR GROUND FAIL MESSAGE DISPLAYED ON EICAS. APPROXIMATELY 20 SECONDS LATER, NR 1 & 2 ENGINE REVERSERS DISAGREE MESSAGE DISPLAYED ON EICAS. OPS CHECK OF THE AIR -SDR HNAA2018011100004Fuse · failedHYDRAULIC SYSTEM 1 FAIL EICAS MESSAGE. HYD PRESSURE ZERO PSI WITH ELECTRIC PUMP IN AUTO OR ON POSITION. R & R NR 1 HYDRAULIC FUSE F0155 IAW SB 145-29-007. OPS CHECKED OK.SDR HNAA2017112800384Door · unsecureCARGO DOOR OPEN INDICATION CAME ON AT FL 300, FELT DECOMPRESSION IN CABIN. CREW VERIFIED DECOMPRESSION ON EICAS. PERFORMED A CARGO DOOR ACTUATING AND LOCKING MECHANISM OPS CHECK IAW AMM 52-31-00-700-801-A.SDR HNAA2017081800277Warning Message · false activationCARGO DOOR OPEN EICAS MESSAGE AND INDICATION ON MFD. MAINTENANCE PERFORMED AMM 52-76-01-000-801-A, DUE TO NUISANCE MESSAGE. COMPLIED WITH FLIGHT CREW PROCEDURES.SDR HNAA2017052700191Elec Connector · dirtyBRAKES DEGRADE EICAS MESSAGE DISPLAYED WHEN BRAKES WERE APPLIED. CLEANED THE ELECTORICAL CONNECTORS AT BCU, OPS CHECKED IAW AMM32-41-00. OPS CHECKED GOOD, OK FOR SERVICE.SDR HNAA2017041000112Fadec · failedNR 1 ENGINE HAS NO FADEC INDICATION, CYCLED THE CIRCUIT BREAKER, NO FIX. R & R THE NR 1 FADEC IAW MM 73-25-10. GROUND RAN ENGINES IAW MM 72-00-00. OPS CHECKED GOOD. OK FOR SERVICE.SDR SIMA20170125008Cup · corrodedDURING INSPECTION, QA FOUND THE TOILET WASTE DRAIN VALVE CUP CORRODED. AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE TOILET WASTE DRAIN VALVE CUP IAW SRM 51-40-02, 51-20-01, 51-40-06, AND 51-20-03.SDR SIMA20170122007Beam · crackedDURING MBV INSPECTION, QA FOUND A CRACK AT AFT NUT PLATE HOLE ON LAV RT HAT BEAM. AIRCRAFT WAS REMOVED FROM SERVICE FOR MBV INSPECTION AND WILL BE RETURNED TO SERVICE AFTER MBV INSPECTION. REMOVED DAMAGE AND INSTALLED DOUBLER TO RT HAT BEAM AT AFT NUT PLATE HSDR SIMA20170122006Beam · corrodedDURING MBV INSPECTION, QA FOUND CORROSION AT THE FWD NUT PLATE HOLE OF THE LAV RT HAT BEAM. AIRCRAFT WAS REMOVED FROM SERVICE FOR MBV INSPECTION AND WILL BE RETURNED TO SERVICE AFTER MBV INSPECTION. REMOVED DAMAGE AND INSTALLED DOUBLER TO RT HAT BEAM AT FWD NSDR SIMA20170120006Channel · corrodedDURING MBV INSPECTION, QA FOUND CORROSION ON FR 22 AROUND LOWER NUT PLATE HOLE. AIRCRAFT WAS REMOVED FROM SERVICE FOR MBV INSPECTION AND WILL BE RETURNED TO SERVICE AFTER MBV INSPECTION. REPAIRED FR 22 CORROSION AROUND LOWER NUT PLATE HOLE IAW SRM 53-00-04 RESDR SIMA20170114003Yoke · crackedDURING MBV INSPECTION, QA FOUND LT PYLON LOWER FORWARD ENGINE MOUNT SUPPORT YOKE CRACKED. AIRCRAFT WAS REMOVED FROM SERVICE FOR MBV INSPECTION AND WILL BE RETURNED TO SERVICE AFTER MBV INSPECTION. REMOVED AND REPLACED LT PYLON LOWER FORWARD ENGINE MOUNT SUPPOSDR SIMA20170114004Yoke · crackedDURING MBV INSPECTION, QC FOUND RT ENGINE FWD LOWER YOKE FITTING CRACKED. AIRCRAFT WAS REMOVED FROM SERVICE FOR MBV INSPECTION AND WILL BE RETURNED TO SERVICE AFTER INSPECTION. REMOVED AND REPLACED RT ENGINE FWD LOWER YOKE FITTING IAW EO-EM-54MR-386. AIRCRAFT SDR SIMA20161204002Bulb · burned outEXTERNAL EMERGENCY LIGHT ON THE RT LOWER FAIRING BURNED OUT. R & R EXTERNAL EMERGENCY LIGHT BULB IAW AMM 33-50-10. OPS CHECKED GOODSDR SIMA20161129004Connector · brokenEMERGENCY FLOOR STRIP BETWEEN SEAT ROW 14 AND ROW 16 HAS A BROKEN CONNECTOR. REMOVED AND REPLACED EMERGENCY FLOOR STRIP BETWEEN SEAT ROW 14 AND ROW IAW AMM 33-50-12SDR SIMA20160908001Door · dirtyF/A HAVING DIFFCULTY OPENING MAIN DOOR. CLEAN AND LUBED PASSENGER DOOR IAW AMM 52-10-00. OPC GOOD.SDR SIMA20160906005Light · inoperativeSERVICE DOOR EMERGENCY LIGHT INOPERATIVE. R & R SERVICE DOOR EXTERNAL EMERGENCY LIGHT LAMP IAW AMM 33-50-10-000-801-A & 33-50-10-400-801-A, OPS CHECK GOOD AT THIS TIME.SDR SIMA20160826003Lock · fodMAIN CABIN DOOR WILL NOT OPEN FROM THE INSIDE WILL ONLY OPEN FROM THE OUTSIDE. INSPECTED MAIN CABIN DOOR IAW AMM 52-10-01 FOUND LATCH SPRING MECHANISM BRKOEN. DURING TROUBLESHOOTING FOUND FOD IN LOCK MECHANISM, REMOVED FOD AND C/W OPS CHECK IAW AMM 52-18-00,
Back to N659AE