N66057

Service difficulty reports · 76

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N66057' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR CALA2017011600119Light · inoperativeR2/L1 EXTERIOR EMERGENCY LIGHTS INOP. RELAMPED L1 DOOR EMERGENCY EXT LIGHT. REPLACED FUSE IN R2 DOOR EMERGENCY LIGHT PWR SUPPLY SYSTEM. OPS CHECKED NORMAL REF AMM 33-51-06.Jan 16, 2017 · N66057 · Boeing 767424ER · Emergency LightingSDR CALA2017011600118Light · inoperativeEMERGENCY CEILING LIGHT INOP 36F AND 43D. RELAMPED EMERGENCY CEILING LIGHT AT POS 36F(RT) AND 43D(LT). SYS OPS CHECKED NORMAL REF AMM 33-51-04.Jan 16, 2017 · N66057 · Boeing 767424ER · Emergency LightingSDR CALA2016111800934Lamp · inoperativeEMERGENCY LIGHTS INOPERATIVE AT SEAT ROW 17D & 38D. REPLACED THE LAMP, OPS CHECKED GOOD.Nov 18, 2016 · N66057 · Boeing 767424ER · Emergency LightingSDR CALA2015071400563Seal · dirtyAT FL 340 LOUD CYCLING SQUEAL FROM RT COCKPIT WINDOW AT AFT PORTION BEHIND PLASTIC COVER WITH HIGH DIFFERENTIAL PRESS. THE SOUND STOPPED DESCENDING THROUGH FL 320 & DID NOT OCCUR AGAIN DURING DIVERT AT FL 220. ACCOMPLISHED VISUAL INSPECTION OF NR 2 & 3 RT WIJul 12, 2015 · N66057 · Boeing 767424ER · Flight Compartment WindowsSDR CALA2015030200137Connector · not seatedEMERGENCY EXIT LIGHTS AT SEAT ROWS 4 & 5 ARE INOPERATIVE. RESEATED EEPL CONNECTOR ON SEAT ROW 6 IAW WDM 33-51-18. EMER LIGHTS CHECKED GOOD IAW AMM 33-51-00-715-001.Mar 2, 2015 · N66057 · Boeing 767424ER · Light System WiringSDR CALA2014120801507Battery Pack · weakSUPPORT TASK R4 DOOR ABOVE ATTENDANTS SEAT EXIT SIGN FOUND DIM. R4 DOOR ATTENDANTS SEAT BATTERY REPLACED & EMER LIGHT TEST FOUND NORMAL IAW AMM 33-51-01.Dec 6, 2014 · N66057 · Boeing 767424ER · Emergency LightingSDR CALA2013011600041Pcu · leakingHYDRAULIC PRESSURE LOW, COMPLIED WITH UNABLE TO EXTEND T/E FLAPS BEYOND 5. L/E SLAT DISAGREE T/E FLAP DISAGREE, R & R LT, INBD (CTR HYD SYS) ELEVATOR ACTUATOR, L/E SLAT INBD MOTOR & T/E FLAP PDU ELECTRIC MOTOR, OPS CHECKED GOOD.Jan 16, 2013 · N66057 · Boeing 767424ER · Elevator Control SystemSDR CALA2012032000200Floor Support · corrodedBS 325 LBL 88 LONGITUDINAL FLOOR SUPPORT CORRODED. CABIN BS 325 LBL 88 LONGITUDINAL FLOOR SUPPORT REPAIRED AS PER ECRA 5310-05464 REV HFEC NIL CRACK FOUND ATTACH MAINTAINED WORK SHEET FORM 44.0008 ITEM 1 TO ITEM 3 ACCOMPLISHED.Mar 20, 2012 · N66057 · Boeing 767424ER · Fuselage Miscellaneous StructureSDR CALA2012032000203Floorbeam · corrodedCABIN BS 325 LBL 52 TO 57 FLOORBEAM CORRODED. CABIN BS 325 LBL 45" TO LBL 61" FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 201 AND HFEC NIL CRACK FOUND ATTACH MAINTENANCE WORK SHEET FORM 44.0008 ITEM 1 TO ITEM 21 ACCOMPLISHED.Mar 20, 2012 · N66057 · Boeing 767424ER · Fuselage Main, Floor BeamSDR CALA2012032000202Floorbeam · corrodedCABIN BS 3043 LBL 20 TO 35 FLOORBEAM CORRODED. CABIN BS 303 LBL 20 TO LBL 35 FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 201 AND HFEC NIL CRACK FOUND ATTACH MAINTENANCE WORK SHEET FORM 44.0008 ITEM 1 TO ITEM 24 ACCOMPLISHED.Mar 20, 2012 · N66057 · Boeing 767424ER · Fuselage Main, Floor BeamSDR CALA2012032000201Floorbeam · corrodedCABIN BS 325 RBL 22-33 FLOORBEAM CORRODED. BS 325 RBL 13 TO RBL 35 FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 21 AND HFEC NIL CRACK FOUND ATTACH MAINTENANCE WORK SHEET FORM 44.0008 ITEM 1 TO ITEM 21 ACCOMPLISHED.Mar 20, 2012 · N66057 · Boeing 767424ER · Fuselage Main, Floor BeamSDR CALA2012030500144Fitting · corrodedCABIN: BS 1592 LBL 15 AND LBL 50 GALLEY TIE DOWN FITTING CORRODED. CABIN BS 1592 LBL 15 AND LBL 50 GALLEY TIE DOWN FITTINGS REPLACED AS PER AMM 25-31-04 AND SRM 51-40-04 (2EA).Mar 2, 2012 · N66057 · Boeing 767424ER · Fuselage, Equipment Attach FittingsSDR CALA2012030500143Fitting · corrodedCABIN: BS 1614 LBL 50 AND RBL 50 GALLEY TIE DOWN FITTING CORRODED. CABIN BS 1614 LBL 50 AND RBL 50 TIE DOWN FITTINGS REPLACED AS PER AMM 25-31-04 AND SRM 51-40-04 (2EA).Mar 2, 2012 · N66057 · Boeing 767424ER · Fuselage, Equipment Attach FittingsSDR CALA2011072200503Unknown · malfunctionedWITH FLAPS UP AT 230 KNTS APPROXIMATELY 15 MINUTES PRIOR TO LANDING THE L/E SLAT ASYM EICAS MESSAGE ILLUMINATED, DECLARED AN EMERGENCY AND COMPLIED WITH QRH. INSPECTED L/E SLATS & T/E FLAPS, NO DEFECTS NOTED, FOUND MSG 27 -81021 ON PSEU, PERFORMED PSEU BITE, Jul 21, 2011 · N66057 · Boeing 767424ER · Leading Edge Slat Position Indicating SystemSDR CALA2011062900456Relay · failedPASSENGER OXYGEN PSU MANUAL DEPLOY TEST FAILED OXYGEN CONT MANUAL DEPLOY TIME DELAY RELAY K466 REPLACED AND OXYGEN PSU MANUAL DEPLOY OPERATION TEST CARRIED OUT NORMAL REF AMM 35-21-00.Jun 29, 2011 · N66057 · Boeing 767424ER · Passenger Oxygen SystemSDR CALA2010041500140Unknown · odorSMELL ODOR OF BURNING PLASTIC AT ROWS 18ABC AND SEAT 24AB. ENTERTAINMENT UNIT BELOW SEAT 18C FOUND TO BE WARMER HOTTER THAN THE OTHER UNITS ADJACENT TO IT. SHUTDOWN ENTERTAINMENT SYSTEM AS A RESULT. COULD NOT VERIFY FAULT. SMELL ODOR ACTUALLY ORIGINATED ATApr 15, 2010 · N66057 · Boeing 767424ER · Air Distribution SystemSDR CALA2009042700216Socket · corrodedDOOR L4 OUTSIDE EMERGENCY LIGHT INOPERATIVE. FOUND LIGHT SOCKET WITH CORROSION, CLEANED SOCKET CHECKS GOOD PER AMM 33-51-00.Apr 25, 2009 · N66057 · Boeing 767424ER · Emergency LightingSDR CALA2009042700215Connector · looseEMERGENCY CEILING LIGHT AT ROWS 2 AB INOPERATIVE. FOUND CONNECTION LOOSE ON CEILING EMERGENCY LIGHT AT ROW 2 A, B GROUND, CHECKS GOOD PER AMM 33-51-00.Apr 25, 2009 · N66057 · Boeing 767424ER · Light System WiringSDR CALA0700220Charger · inoperativeTHE EMERGENCY LIGHTS AT ROWS 18-21DEF WERE FOUND INOPERATIVE. THE BATTERY AND CHARGER WERE REPLACED IAW MM 33-51-07, PAGE 201.Apr 29, 2007 · N66057 · Boeing 767424ER · Emergency LightingSDR CALA0600448Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT BS 325, LBL 54. THE FLOORBEAM WAS REPAIRED IAW SRM 53-00-51, REPAIR 1, FIGURE 201.Oct 26, 2006 · N66057 · Boeing 767424ER · Fuselage Main, Floor BeamSDR CALA0600447Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT BS 303, LBL 30. THE FLOORBEAM WAS REPAIRED IAW SRM 53-00-51, REPAIR 1, FIGURE 201.Oct 26, 2006 · N66057 · Boeing 767424ER · Fuselage Main, Floor BeamSDR CALA0600434Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT BS 303, LBL 30. THE FLOORBEAM WAS REPAIRED IAW SRM 53-00-51, REPAIR 1, FIGURE 201.Oct 26, 2006 · N66057 · Boeing 767424ER · Fuselage Main, Floor BeamSDR CALA0600433Floor Support · corrodedINSPECTION FOUND FLOOR SUPPORT CORRODED AT BS 303-325, LBL 30. THE FLOOR SUPPORT WAS REPLACED IAW SRM 51-10-02, PAGE 8.Oct 26, 2006 · N66057 · Boeing 767424ER · Fuselage Miscellaneous StructureSDR CALA0500438Charger · inoperativeTHE EMERGENCY LIGHT BATTERY FAILED TEST PER W/C 64-3350-1-3800. THE BATTERY PACK AND CHARGER WERE REMOVED AND REPLACED IAW MM 33-51-07.Dec 13, 2005 · N66057 · Boeing 767424ER · Emergency LightingSDR CALA0400620Wire Harness · burnedSMOKE WITH ELECTRICAL ODOR APPEARED IN CABIN SHORTLY AFTER TAKEOFF. ELECTRICAL SPARKING IN CEILING AREA FORWARD OF L-3 DOOR. LIGHTS & NSFSB SIGNS FLICKERED & PA SPEAKERS CRACKLED. HALON FIRE EXTINGUISHER WAS USED ON OVERHEAD AREA OF FORWARD CENTER LAV J. LAug 26, 2004 · N66057 · Boeing 767424ER · Electrical Power System WiringSDR CALA0200535Fuse · blownTHE EMERGENCY LIGHTS ON PASSENGER SEATS ROW 23-28 LT AND RT SIDE WERE FOUND INOPERATIVE. INSPECTION FOUND LOOSE CONNECTOR AT SEAT 22D AND BLOWN FUSE IN POWER SUPPLY FOR EMERGENCY LIGHTS AT STA 785 RT SIDE. SECURED LOOSE CONNECTOR AND REPLACED POWER SUPPLY.Nov 8, 2002 · N66057 · Boeing 767424ER · Emergency Lighting
Back to N66057