N663NK
Service difficulty reports · 80
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N663NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N663NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2025100239111Bottle · low pressureL4 DOOR ASSIST BOTTLE PRESSURE LOW-SERVICED L4 DOOR ASSIT BOTTLE TO IT PROPER LEVEL REF AMM 52-10-00.SDR GTIA2025091139073Unknown · odorDIRTY SOCK SMELL ON TAKE OFF, PACK 1 OFF AND SMELL DISSIPATED. DESCRIPTION OF ODOR/FUMES: PERSISTENT, MUSTY DRY SMELL. APPARENT CABIN SOURCE: UNKNOWN. NO VISIBLE SMOKE/HAZE. NO MEDICAL ATTENTION REQUIRED. -REF TSM 05-50-00-810-831A . APU VERIFIED NO LEAKS. PRESDR GTIA2025072138995Unknown · odorROTTEN EGG SMELL REPORTED AFT CABIN BY THE FAS ISOLATED PACK 2 ODOR WENT AWAY FOR ABOUT 40 MINS. THE SMELL CAME BACK, PROCEDING TO ISOLATE PACK 1, SMELL DISSIPATED FOR A FEW MINS. EVENTUALLY ODOR CAME BACK SO WE PERFORMED THE AIR PACK 1+2 PROCEDURE AND DESCENDSDR GTIA2025032038809Bottle · low pressureDURING SERVICE CHECK FOUND L4 DOOR ASSIST BOTTLE BELOW LIMITS. INSTALLED SAFETY DEVICE.-SERVICED DOOR ASSIST BOTTLE IAW AMM 52-22-00. BOTTLE SAFETY DEVICE DISENGAGED AND SECURED.SDR GTIA2025030338773Flashlight · inoperativeL-3 FLASHLIGHT IS FLASHING RED LIGHT-R&R FLASHLIGHT @ ZONE K MID RH F/A STA. OPS V GOOD REF CMM 25-60-13. OK FOR CONT. SVCSDR GTIA2025020338712Bottle · low pressureL4 DOOR ASSIST BOTTLE NEED SERVICING-SERVICED L4 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2024093038403Bottle · low pressureL4 DOOR ASSIST ACCUMULATOR BELLOW LIMITS-SERVICED L4 ASSITS DOOR IAW AMM 52-10-00SDR GTIA2024062438192Valve · faultyHYD. Y ENG 2 PUMP LO PR.-R+R FLUID SAMPLING VALVE OF YELLOW HYD SYS IAW AMM 29-13-34 PERFORMED LEAK CHECK NO LEAKS NOTED AT THIS TIME. A/C OK FOR SERVICE.SDR GTIA2024041438064Flashlight Assy · inoperativeL2 FA SEAT FLASHLIGHT INOP ( FLASHLIGHT AND HOLDERS (FLIGHT DECK OR CABIN) )-REMOVED AND REPLACED L2 FA FLASHLIGHT IAW AIRCRAFT DRAWING EMER EQUIP REV 3 DATED 5/19/22. THIS CLOSES DMI 3298503-1. MOC NOTIFIED. PLACARD REMOVEDSDR GTIA2024020637832Connector · faultedL/G LGCIU 2 FAULT-SEE ITEM # 3489776-1 FOR CORRECTIVE ACTION, REF RIN-15591 R+R PROX SNSR 29GA-A CONNECTOR IAW ESPM 20-44-11-01 & 20-48-21-01. BITE TEST OK IAW MM 32-69-00-710-001-A NO FAULT NOTEDSDR GTIA2024020637831Bottle · dischargedPASSENGER / CREW DOOR L/4 DOOR ASSIT BOTTLE NEED SERVICING -SERVICED PASSENGER / CREW DOOR L/4 IAW AMM 52-10-00SDR GTIA2024012337795Kit · unsecureLOUD THUMPING HEARD AND FELT CLIMBING THROUGH 5000MSL INCREASING NOSE UP PITCH ABOVE 5 MADE IT WORSE LOWERING GEAR CAUSED ABNORMAL INDICATION AND NOISE TO DISSAPEAR.-REF. TSM 05-50-00-810-801-A PERFORMED DETAIL INSPECTION AND OPS CHECK OF ALL FLIGHT CONTROLS. SDR GTIA2023122637721Unknown · unknown"PREVIOUS REPORTED ROTTEN EGG SMELL DESCENDING THROUGH 12,000 FT FROM REAR OF A/C. -PERFORMED OPS CHECK OF APU AND PACKS, NO DEFECTS/OR ODORS NOTED AT THIS TIME CHK DONE IAW TSM 05-50-00 (SUSPECTED MISCELLANEOUS TYPE 10 PAX/AMBIENT AIR ODOR).
MOC 68083 "SDR GTIA2023120137669Megaphone · inoperativeL1 MEGAPHONE LOW VOLUME-R&R L1 MEGAPHONE IAW SPIRIT AIRLINES EMERGENCY EQUIPMENT LAYOUTSDR GTIA2023071337325Unknown · unknownDESCENDING THROUGH PL 220 FA REPORTED US WETSOCK ODOR. RAN SUPPLEMENTAL PROCEDURE FOR ELIMINATION OF ODOR/ FUME AND FA REPORTED THE WET SOCK SMELL WENT AWAY -PERFORM IDENTIFICATION OF THE CAUSE IAW TSM 05-50-00. NO WET SOCK ODOR NOTED. AIRCRAFT OK FOR SERVICESDR GTIA2023051937198Unknown · unknownL4 & R4 DOOR ASSIST PRESSURE LOW-SVCD L4 & R4 DOOR ASSIST BOTTLES IAW AMM 52-10-00SDR GTIA2023020636940Not Reported · not reportedAFT CABIN CREW REPORTED ODOR MAKING THEM NAUTIOUS. PERFORMED COM 3.226 AND ISOLATED PACK 2. CREW REPORTED ODOR HAD SUBSIDED AFTER.-COMPLETED INSPECTION OF CABIN A.C. USING AIR QUALITY REPORTING FORM. NO ODOR NOTED AT THIS TIME. IAW TSM 05-50-00-810-831A.SDR GTIA2022112636799Bottle · low pressureL2 DOOR (DAMPER) ASSIST BOTTLE FOUND TO BE BELOW 1000 PSI.-SERVICED L2 DOOR ASSIST BOTTLE PRESSURE TO APPLICAL TEMPERATURE IAW AMM TASK 52-10-00-614-050-C.SDR GTIA2022092936685None · noneDURING WEEKLY CHECK FOUND L-3 DOOR ASSIST BOTLE NEED SERVICING.-SERVICED DOOR ASSIST BOTTLE ON L-3 DOOR IAW AMM 52-10-00SDR GTIA2022072136550None · nonePER WEEKLY FOUND L3 AND L4 DOOR EMERGENCY ASSIST BOTTLE REG SERVICE-SERVICED DOOR L3 AND L4 EMERGENCY ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2022060236463None · none"L4 DOOR ASSIST REQ SERVICE -SERVICED L4 DOOR ASSIT IAW AMM 52-10-00
NK791/NK2643
02/23.....02/23"SDR GTIA2022052636439None · none"L 2,3,& 4 DOOR ASSIT REQUIRE SERVICE -SERVICED L 2,3,& 4 DOOR ASSIT IAW AMM 52-10-00
GAUGE NK2643 CAL DUE 2/23
T/W NK791 CAL DUE 2/23"SDR GTIA2022050236405None · noneL4 DOOR ASSIST REQUIRES SERVICE-L4 DOORS ASSIST BOTTLE SERVICED IAW AMM 52-10-00 LEAK CK GOODSDR GTIA2022032836351Bottle · low pressureL4 DOOR ASSIST BOTTLE REQUIRES SERVICE-SERVICED L4 DOOR BOTTLE IAW AMM 52-10-00SDR GTIA2022021436275None · noneR4 ASSIT BOTTLE NEEDS SERVICING -SERVICED R4 DOOR ASSITS BOTTLE IAW AMM 52-10-00. NO LEAK NOTED AT THIS TIMESDR GTIA2022013136248Floor Panel · corrodedREF MDDR 20794 FWD INBD FA FLASHLIGHT-R/R FWD INBD FA FLASHLIGHT IAW CMM 25-60-13. THIS CLEARS MEL. PLACARD REMOVED.SDR GTIA2022010636208A/C Pack · contaminatedSTRONG ODOR SMELLED IN COCKPIT DURING DECENT SMELL WENT AWAY AFTER TURNING OFF PACK #1 -PERFORMED DECONTAMINATION OF #1 PACK PER AMM 21-00-00. WITH ENG #1 & APU NO ODOR AT THIS TIME.SDR GTIA2021092436003Unknown · odorAIR QUALITY EVENT DURING DESCENT OIL SMELL DURING 11000FT, PACU 1 OFF SMELL WENT AWAY ( PACKS A321 WITH MOD. 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/ MP K6443 (ENHANCED ECS) - FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED )-PERFORMED SDR GTIA2021092135999None · noneCAPTAIN REPORT FUEL LEAKING FROM #1 ENG , FUEL LEAK INCREASE ON DESCENT-REMOVED FCOC REPLACED PACKING AND REINSTALLED FCOC OPS AND LEAK CHECK GOOD IAW AMM 79-21-43 NK2224 DUE 2/22 NK1926 DUE 2/22SDR GTIA2021090335971Bottle · low pressureL3, R4, L4 DOOR ASSIST BOTTLE PSI LOWER THAN WEEKLY LIMIT -SVC L3, R4, L4 DOOR ASSIST BOTTLES TO PROPER PRESSURE AS PER AMM 52-10-00SDR GTIA2021081335933Bottle · low pressureL4 AND R4 DOOR ASSIST BOTTLE BELO PRESS-SERVICED L4 ANBD R4 DOOR ASSIST BOTTLE TO PROPER PRESS IAW AMM 52-10-00SDR GTIA2021081335932Bottle · low pressureL3 DOOR ASSIST BOTTLE BELOW WEEKLY PRESS-SERVICED L3 DOOR ASSIST BOTTLE TO PROPER PRESS IAW AMM 52-10-00SDR GTIA2021072935899Unknown · odorAFTER ROTATION , VERY STRONG SMELL IN COCKPIT ( LIKE CLEANING PRODUCTS ) -PER TSM 05-50-00-810-831-A . ENG# 1 BLEED VERIFIED NO LEAKS. A/C W/APU NO SMELL NOTED ISOLATED PACK, NO SMELL NOTED. RAN ENG #1 ISOLATED BLEED, NOSE SMELL NOTED. ALL STEP ACCOMPLISHED RESDR GTIA2021070135839Bottle · low pressureL4 AND R4 DOOR BOTTLES( ASSIST) REQUIRE SERVICING-SERVICED L4 AND R4 ASSIST BOTTLES REF A321 AMM 52-10-00SDR GTIA2021060735778Bottle · low pressureL4 DOOR ASSIST BOTTLE LOW -SERVICES L4 DOOR IAW AMM 52-10-00.SDR GTIA2021060135775Unknown · odorDURING DESCENT AFT FA"S REPORTED SMELL OF OIL NEAR AFT LAV-ACCOMPLISHED TSM 05-50-00-810-831 FOR CABIN ODOR RAN BOTH PACKS ON ENG BLEED ISOLATED PACKS NO SIGN OF CONTAMINATION ON ENG 1 OR ENG 2 NO ODOR NOTED WITH THE AEROTRACER. A/C OK FOR SVC & AMM 71-00-00 FSDR GTIA2021051735741Bottle · low pressureL4 + R4 DOOR ASSIST ACCUMULATORS LOW-SERVICED L4 + R4 DOOR ASSIST ACCUMULATORS TO PROPER PRESSURE IAW AMM 52-10-00SDR GTIA2021051735740Bottle · low pressureL3 DOOR ASSIST ACCUMULATOR LOW-SERVICED L3 DOOR ASSIST ACCUMULATOR TO PROPER PRESSURE IAW AMM 52-22-00SDR GTIA2021011435544Bottle · low pressureL3 DOOR ASSIST BOTTLE REQUIRES SERVICE. SERVICED L3 DOOR ASSIST BOTTLE, IAW AMM 52-10-00.SDR GTIA2020121435498Slide · detachedAIR RETURN DUE TO L1 DOOR ESCAPE SLIDE COMING OFF THE DOOR SHORTLY AFTER TAKE OFF. R & R L1 DOOR SLIDE, IAW AMM 25-62-44. OPERATIONS CHECK GOOD, NO DEFECTS NOTED. INSPECTED SLIDE ATTACH POINTS, BOLTS FOUND DEFECTIVE. NO OTHER DEFECTS NOTED, PER 25-62-00.SDR GTIA2020111935454Bottle · low pressureL2, L3, R2, R3, & R4 DOOR ASSIST BOTTLES LOW. SERVICED L2,L3,R2,R3, & R4 DOOR, IAW AMM 52-22-00.SDR GTIA2020101535392Bottle · low pressureR4 DOOR ASSIST BOTTLE NEED SERVICE. SERVICED R4 DOOR ASSIST BOTTLE TO PROPER LEVEL, IAW AMM 52-10-00.SDR GTIA2020101535391Bottle · low pressureL4 DOOR ASSIST BOTTLE NEED SERVICE. SERVICED L4 DOOR ASSIST BOTTLE TO PROPER LEVEL, IAW AMM 52-10-00.SDR GTIA2020100535375Bottle · low pressureL3 DOOR ASSIST BOTTLE REQUIRE SERVICING. SERVICED L3 DOOR ASSIST BOTTLE, IAW AMM 52-10-00.SDR GTIA2020091735360Accumulator · low pressureR4 AND L3 DOOR ASSIST ACCUMULATORS REQUIRES SERVICE. R4 AND L3 DOOR ASSIST ACCUMULATORS WERE SERVICED, IAW AMM 52-10-00.SDR GTIA2020081335309Bottle · low pressureR2 DOOR ASSIST BOTTLE LOW PRESSURE-SERVICED R2 DOOR ASSIST BOTTLE TO PROPER PRESSURE IAW AMM 52-10-00.SDR GTIA2020071635261Bottle · low pressureDURING WEEKLY CHECK L3 EMER EXIT DOOR ASSIST BOTTLE FOUND TO BE LOW. SERVICED L3 EMER EXIT DOOR ASSIST BOTTLE IAW AMM 52-22-00 TO PROPER LIMITS.SDR GTIA2020071635260Bottle · low pressureDURING WEEKLY CHECK R4 DOOR ASSIST BOTTLE FOUND TO BE LOW. SVC R4 DOOR ASSIST BOTTLE IAW AMM 52-10-00 TO PROPER LIMITS.SDR GTIA2020062535211Bottle · low pressureR4 DOOR BOTTLE ASSISTANCE REQIER SERVICE. SERVICE R4 DOOR BOTTLE ASSISTANCE TO PROPER LEVEL IAW AMM 52-00-00.SDR GTIA2020031635088Unknown · odorFA REPORT MUST/DRY DIAPER SMELL DURING LANDING -PERFORMED INSPECTION AND IDENTIFICATION OF THE CAUSE FOR CABIN ODOR. NO ODOR REPRODUCED WITH EACH PACK RUNNING IAW AMM 05-50-00-810-831-A A/C OK FOR SERVICE