N663NK
Service difficulty reports · 80
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N663NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N663NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2020022735052Bottle · low pressureR4 DOOR ASSIST HAS LOW PRESSURE-SVCD THE R4 DOOR ASSIST IAW AMM 52-10-00SDR GTIA2020021753518Oxygen Box · leakingCREW O2 PRESSURE EXCESSIVE DROP 20LB 10 MIN 1630-1510-REPLACED F/O O2 MASK STORAGE CONTAINER PER AMM 35-12-41. TEST OK NO LEAKS NOTED AT THIS TIME.SDR GTIA2020012734972Bottle · low pressureR4 DOOR ASSIST REQUIRES SERVICING-SERVICED R4 PAX DOOR ASSIST CYLINDER IAW AMM 52-10-00SDR GTIA2019120984849Bottle · low pressureDOOR ASSIST BOTTLE FOR BOTH LEFT AND RIGHT AFT CREW PASSENGER DOOR REQUIRE SVC-SVC BOTH LEFT AND RIGHT AFT CREW / PASSENGER DOOR ASSIST BOTTLES IAW AMM 52-10-00SDR GTIA2019110134753Bottle · low pressureR4 DOOR ASSIST BOTTLE REQUIRES SERVICING-SERVICED R4 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2019100744667Bottle · low pressureR2 DOOR ASSIST BOTTLE REQUIRES SERVICING-SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00. LEAK AND OPS CHECK NORMALSDR GTIA2019091534627Blower · faultedON CLIMBOUT ON THEECAM VENT BLOWER AND EXTRACT APPEARED SUSPECTING POSSIBLE AVIONICS SMOKE HOWEVER NO OTHER INDICATIONS WERE PRESENT. PERFORMED AEVC TEST IAW 21-26-00. PFR SHOWS INLER EXTRACT FAULT AND VENT BLOWER FAULT. CLASS 3 FAULTS SHOW'S AEVC. OBSERVED DUSDR GTIA2019090634600Bottle · low pressureR2 DOOR ASSIST BOTTLE LOW. SERVICED R2 DOOR ASSIST BOTTLE TO PROPER LEVEL IAW AMM 52-10-00.SDR GTIA2019072203499Bottle · low pressureR4 PASSENGER DOOR ASSIST BOTTLE REQUIRES SERVICING. SERVICED R4 PASSENGER DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2019071503482Bottle · low pressureRIGHT HAND (R4 DOOR) DOOR ASSIST BOTTLE NEEDS SERVICING. SERVICED DOOR ASSIST BOTTLE FOR R4 DOOR IAW AMM 52-10-00-614-001 LEAK CK NORMALSDR GTIA2019051703348Bottle · low pressureR4 DOOR ASSIST BOTTLE REQUIRES SERVICING. SERVICED R4 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2019042953301Unknown · odorFA C REPORTED ON TAKE OFF AND THAT A STORAGE ODOR. GAVE HER A HEADACHE AND RUNNY EYES DURING CRUISE TWO EVENTS OF A STRANGER SMELL ROW R4-PERFORMED TSM 05-50-00-810-831A TYPE 9 MISCELLANEOUS NO FURTHER DEFECTS NOTED A/C OK FOR SVC.SDR GTIA2019032803251Bottle · lowR4 DOOR ASSIST BOTTLE REQUIRES SERVICING. SERVICED R4 DOOR ASSIST BOTTLE IAW AMM 52-10-00. NO FURTHER DEFECTS NOTED AT THIS TIME.SDR GTIA2019031703223Unknown · odorUPON DECENT FA'S (B)(D)(E) STATED RUBBER BURNING SMELL COMING FROM AFT GALLEY. DECLARED EMERGENCY. AFTER TALKING WITH LEAD FA, IT WAS CONTANINED ONLY TO AFT GALLEY AND POSSIBLE FUME EVENT. FA (B) HEADACHE, FA (D) EYES ITCHING AND TWITCHING, FA(E) HEADACHE, SCRSDR GTIA2019020873143Bottle · low pressureR4 DOOR ASSIST BOTTLE NEEDS SERVICING-SERVICED R4 DOOR ASSIST BOTTLE TO PROPER LEVEL IAW AMM 52-22-00SDR GTIA201812243035Bottle · low pressureR4 DOOR ASSIST NEED SERVICE-SERVICE DOOR TO CORRECIT LIMIT IAW AMM 52-10-00.SDR GTIA2018121733019Bottle · low pressureR4 PAX DOOR ASSIST BOTTLE LOW PRESS -SERVICED R4 PAX DOOR ASSIST BOTTLE TO PROPER PRESSURE IAW AMM 52-10-00SDR GTIA2018100102872Bottle · low pressureR2 DOOR ASSIST BOTTLE LOW -SVCD R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA201808202808Bushing · looseBUSHING ON THE L4 DOOR ASSIST BOTTLE CAME LOOSE. SECURED THE BUSHING IAW AMM 52-13-14, OPS CHECKED GOOD.SDR GTIA201808202807Bottle · low pressureR3 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2017111202241Bottle · low pressureL1 DOOR ASSIST BOTTLE IS LOW. CHARGED THE BOTTLE IAW AMM 52-10-00. NO LEAKS NOTED.SDR GTIA2017101202192Bottle · low pressureL1 DOOR ASSIST ACCUMULATOR HAD LOW PRESSURE. SERVICED THE DOOR ASSSIT BOTTLE IAW AMM 52-10-00SDR GTIA2017091502170Cylinder · low pressureDURING RON CHECK FOUND L1 PAX DOOR ASSIST BOTTLE BELOW RON LIMITS. SERVICE L1 PAX DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2017090702169Bottle · low pressureL1 DOOR ASSIST BOTTLE LOW. SERVICED L1 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2017082802157Bottle · low pressureL1 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED THE DOOR ASSIST BOTTLE IAW 52-51-00.SDR GTIA2017071802089Bottle · low pressureL1 DOOR ASSIST PRESSURE LOW . SERVICED L1 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2017061601980Bottle · low pressureDURING WEEKLY CHECK OF MAIN CABIN, FOUND THE L1 DOOR BOTTLE ASSIST PRESURE BELOW LIMITS. SERVICED THE L1 DOOR BOTTLE ASSIST TO PROPER PRESSURE IAW AMM 52-10-00-614-001-A.SDR GTIA2017060601965Bottle · low pressureL1 DOOR ASSIST BOTTLE LOW. SERVICED L1 DOOR BOTTLE IAW AMM 52-10-00, NO LEAKS NOTED.SDR GTIA2016122301714Bottle · low pressureL1 DOOR ASSIST BOTTLE REQUIRES SERVICE. SERVICED L1 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2016092901612Bottle · low pressureL1 DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED L1 DOOR ASSIST BOTTLE WITH NITROGEN IAW AMM 52-10-00.
Back to N663NK