N667FE
Service difficulty reports · 237
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N667FE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N667FE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA2018082182092Floor Panel · crackedFWD CARGO FLOOR PANEL 151VF WAS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. CLASSIFED AS A CAT A MAJOR REPAIR.SDR FDEA2018082182091Floor Panel · crackedAFT CARGO FLOOR PANEL 152TF WAS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. CLASSIFED AS A CAT A MAJOR REPAIR.SDR FDEA2018082182090Floor Panel · crackedAFT CARGO FLOOR PANEL 152QF WAS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. CLASSIFED AS A CAT A MAJOR REPAIR.SDR FDEA2018082182089Floor Panel · crackedAFT CARGO FLOOR PANEL 152PF WAS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. CLASSIFED AS A CAT A MAJOR REPAIR.SDR FDEA2018082182088Floor Panel · crackedAFT CARGO FLOOR PANEL 151MF WAS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. CLASSIFED AS A CAT A MAJOR REPAIR.SDR FDEA2018082182086Floor Panel · damagedFWD CARGO FLOOR PANEL 132QC HAD EDGE DAMAGE. FABRICATED A FLOOR PANEL IAW SRZ 25-005. CLASSIFED AS A CAT A MAJOR REPAIR.SDR FDEA2018082182085Floor Panel · damagedFWD CARGO FLOOR PANEL 132NG WAS DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. CLASSIFED AS AN -A- MAJOR REPAIR.SDR FDEA2018082182084Floor Panel · delaminatedFWD CARGO FLOOR PANEL132LG HAD EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. CLASSIFED AS AN -A- MAJOR REPAIR.SDR FDEA2018082182080Floor Panel · delaminatedFWD CARGO FLOOR PANEL 132KG HAD EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. CLASSIFED AS AN -A- MAJOR REPAIR.SDR FDEA2018082182079Floor Panel · delaminatedFWD CARGO FLOOR PANEL 131RG HAD EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. CLASSIFED AS AN -A- MAJOR REPAIR.SDR FDEA201808182078Floor Panel · delaminatedFWD CARGO FLOOR PANEL 131PG HAD EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. CLASSIFED AS AN -A- MAJOR REPAIR.SDR FDEA20180821077Floor Panel · delaminatedFWD CARGO FLOOR PANEL 131MG HAD EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. CLASSIFED AS AN -A- MAJOR REPAIR.SDR FDEA201808212075Floor Panel · delaminatedFWD CARGO FLOOR PANEL 131SG WAS CRUSHED ON THE EDGE. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. CLASSIFED AS AN -A- MAJOR REPAIR.SDR FDEA201808212074Floor Panel · delaminatedFWD CARGO FLOOR PANEL 131QG HAD EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. CLASSIFED AS AN -A- MAJOR REPAIR.SDR FDEA201808212073Floor Panel · delaminatedFWD CARGO FLOOR PANEL 131NG HAD EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. CLASSIFED AS AN -A- MAJOR REPAIR.SDR FDEA201808212072Floor Panel · delaminatedFWD CARGO FLOOR PANEL 131LG, HAD EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. CLASSIFED AS AN A MAJOR REPAIR.SDR FDEA2018081752045Floor Panel · crackedMAIN CARGO FLOOR PANEL 242TH WAS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRZ-25-005. MAJOR REPAIR. INSTALLED ON WORK CARD 240-FL-FIT.SDR FDEA2018081752044Floor Panel · crackedMAIN CARGO FLOOR PANEL 251XG WAS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRZ-25-005. MAJOR REPAIR. INSTALLED ON WORK CARD 250-FL-FIT.SDR FDEA2018081752043Floor Panel · crackedMAIN CARGO FLOOR PANEL 232TG WAS MISSING AN INSERT AND CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRZ-25-005. MAJOR REPAIR. INSTALLED ON WORK CARD E6-5321-E0339394 PT6.SDR FDEA2018081752042Floor Panel · crackedMAIN CARGO FLOOR PANEL 252GF WAS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRZ-25-005. MAJOR REPAIR. INSTALLED ON WORK CARD 250-FL-FIT.SDR FDEA201808152041Floor Panel · crackedMAIN CARGO FLOOR PANEL 252NH WAS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRZ-25-005. MAJOR REPAIR. INSTALLED ON WORK CARD 250-FL-FIT.SDR FDEA2018081752040Floor Panel · crackedMAIN CARGO FLOOR PANEL 252DF WAS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRZ-25-005. MAJOR REPAIR. INSTALLED IAW WC 250-FL-FIT.SDR FDEA201808152039Floor Panel · crackedMAIN CARGO FLOOR PANEL 252HH WAS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRZ-25-005. MAJOR REPAIR. INSTALLED ON WORK CARD 250-FL-FIT.SDR FDEA2018081752038Floor Panel · crackedMAIN CARGO FLOOR PANEL 252PH WAS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRZ-25-005. CLASSIFIED AS A CAT A MAJOR REPAIR.SDR FDEA201808142025Floor Panel · delaminatedCOURIER FLOOR PANEL 221QF WAS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW DWG SRZ-25-005. MAJOR REPAIR.SDR FDEA201808142024Floor Panel · delaminatedCOURIER FLOOR PANEL 221GF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW DWG SRZ-25-005. MAJOR REPAIR.SDR FDEA201808142023Floor Panel · delaminatedCOURIER FLOOR PANEL 222QF WAS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW DWG SRZ-25-005. MAJOR REPAIR.SDR FDEA201808142022Floor Panel · delaminatedCOURIER FLOOR PANEL 221LF WAS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW DWG SRZ-25-005. MAJOR REPAIR.SDR FDEA201808142021Floor Panel · delaminatedCOURIER FLOOR PANEL 221HF WAS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW DWG SRZ-25-005. MAJOR REPAIR.SDR FDEA2018082302001Floor Panel · crackedMAIN CARGO FLOOR PANEL 241JF WAS CRACKED. FABRICATED A NEW FLOOR PANEL IAW DWG SRZ-25-005, REV M. MAJOR REPAIR.SDR FDEA2018121891977Seat Track · corrodedMAIN DECK COMPARTMENT FRAME 41-44, SEAT TRACK Y0 HAS CORROSION AS MAKED 7 PLACES. SEAT TRACK FOUND TO BE CORRODED OUT OF LIMITS IAW SRM 53-10-16 FIG 103. TRACK REMOVED AND REPLACED IAW SRM 51-40-21 FR41-44 MAJOR REPAIRSDR FDEA2018081491968Floor Panel · crackedMAIN CARGO FLOOR PANEL 241DF HAD A BROKEN INSERT, AND CRACKED. FABRICATED A NEW FLOOR PANEL IAW DWG SRZ-25-005 REV M. MAJOR REPAIR.SDR FDEA2018080761926Doubler · damagedDAMAGE FOUND ON THE DOUBLER AT THE FWD CARDO DOOR CUTOUT, FRAME 20 LOWER SECTION. REMOVED AND REPLACED THE DOUBLER IAW SRM 51-40-21, DRAWING SR30-53-001, SRM 51-40-21, AND SRM 51-23-00. MAJOR REPAIR.SDR FDEA2018061281431Window · crackedON DEPARTURE, DURING CLIMB OUT AT 3500FT CAPTIANS SLIDING WINDOW INSIDE SURFACE CRACKED. ENTIRE WINDOW SPIDER WEBBED. REPLACED LEFT HAND (CAPTAINS) SLIDING WINDOW PER AMM 56-12-11-04. CKS OK FOR SVC.SDR FDEA201712033331Outflow Valve · failedPDIS 667 21-30 9291 03DEC17 MEM OPEN U LOGPAGES:2686339 DURING CLIMBOUT AIRCRAFT FAILED TO PRESSURIZE W/ EITHER AUTO PRESSURE CONTROLLER. LEVELED OFF AT 10,000, CONSULTED QRH, CHECK APU BLEED SWITCH, DOOR PAGE, AND PRESSURE OF PACKS, ALL OKASDR FDEA201710132937Autothrottle Sys · malfunctionedDURING TAKE OFF, OVERHEAD ATS LEVER POPPED OFF TWICE. WOULD NOT RESET. ABORTED TAKEOFF AND RAN QRH, SECOND ATTEMP SUCCESFUL. PERFORMED AN ADJUSTMENT AND TEST OF AUTOTHROTTLE IAW AMM 22-30-00-05-01, NO DEFECTS NOTED. PERFORMED AFS - LAND TESTS IAW AMM 22-4SDR FDEA201706131630Slide · out of positionR1 DOOR WILL NOT ARM. REPOSITIONED SLIDE MATERIAL AT GIRT BAR, ALL SYSTEMS OPERATED NORMALY IAW AMM 52-10-00-03-02, AND AMM 52-10-00-00-02 ACFT OK FOR CONTINUED SERVICE.SDR FDEA201702100506Idg · leakingLOW SPEED (75KTS) REJECT DUE TO A NR 2 IDG FAULT, FOLLOWED BY A NR 2 GENERATOR FAULT ON ECAM. RECONNECTED NR 2 IDG. FOUND FIREWALL CONNECTOR VC4962P LOOSE. TIGHTED IAW WDM 24-11-02. RAN ENGINE IAW JRH. VOLTS/FREQS GOOD UNDER LOAD. NO FAULTS ON GPCU. AFTER ESDR FDEA201601110112Crossbeam · crackedMDCC CROSSBEAM CRACKED AT FRAME 64, Y-1150. REMOVE THE CRACK IAW SRM 51-73-10. REWORK THE REPAIR AREA IAW SRM 53-10-15 FIG 211. CHECK FOR CRACKS TO CUT EDGE & REWORKED AREA IAW NTM 51-10-08 & NO CRACK FOUND. MAKE THE REPAIR PROFILE IAW SRM 53-10-15 FIG 211SDR FDEA201601110111Crossbeam · crackedMDCC CROSSBEAM CRACKED AT FRAME 67, Y1700. CUT THE CRACKED AREA & DEBURR IAW SRM 53-10-15 FIG 211. REWORK THE REPAIR AREA IAW SRM 53-10-15 FIG 211. CHECK FOR CRACKS TO CUT EDGE & REWORKED AREA IAW NTM 51-10-08 & NO CRACK FOUND. MAKE THE REPAIR PROFILE IAW SDR FDEA201601110110Crossbeam · crackedMDCC CROSSBEAM CRACKED AT FRAME 27, Y-700. CUT THE CRACKED PARTIAL IAW SRM 53-10-15 FIG 212. PERFORM HEFC INSPECTION TO THE CUT OUT IAW NTM 51-10-08 & NO CRACK FOUND. FABRICATE THE REPAIR PARTS & DRILL THE FASTENER HOLES & INSTALLED THE REPAIR PARTS IAW SRSDR FDEA201601110109Crossbeam · crackedMDCC CROSSBEAM CRACKED AT FRAME 30, Y1700. CUT THE CRACKED PARTIAL IAW SRM 53-10-15 FIG 21. PERFORM HEFC INSPECTION TO THE CUT OUT IAW NTM51-10-08 & NO CRACK FOUND. FABRICATE THE REPAIR PARTS & DRILL THE FASTENER HOLES & INSTALLED THE REPAIR PARTS IAW SRM 5SDR FDEA201601110108Crossbeam · crackedMDCC CROSSBEAM CRACKED AT FRAME 31, Y1700. CUT THE CRACKED PARTIAL IAW SRM 53-10-15 FIG 212. PERFORM HEFC INSPECTION TO THE CUT OUT IAW NTM 51-10-08 & NO CRACK FOUND. FABRICATE THE REPAIR ANGLE & FILLER & DRILL THE FASTENER HOLES & INSTALL THE REPAIR ANGLE SDR FDEA201601110107Crossbeam · crackedMDCC CROSSBEAM CRACKED AT FRAME 32, Y1700. REWORK THE REPAIR AREA IAW SRM 53-10-15 FIG 212. CHECK FOR CRACKS TO CUT EDGE & REWORKED AREA IAW NTM 51-10-08 & NO CRACK FOUND. MAKE THE REPAIR PROFILE IAW SRM 53-10-15 FIG 212. PERFORMED PENETRANT INSPECTION TO SDR FDEA201601100094Frame · crackedCENTER WING JOINT AT FRAME 40 LT, UPPER FASTENER HOLE FOUND CRACK SIGNAL. COMPLIED WITH EA 6-5710-T0322811 P 1. REPAIR CATEGORY IS B. THRESHOLD INTERVAL 2250 FC & 4860 FH. METHOD IN THE REPAIRED HOLE, ROTO TEST IAW NTM 51-10-01, BASED ON NTM 57-10-39 PART 6SDR FDEA201512033878Unknown · malfunctionedRIGHT CABIN DOOR SLIDE WILL NOT SHOW ARMED ON RT ECAM WHEN PUT IN THE ARMED POSITION. PERFORMED TEST OF R1 DOOR SLIDE ARMING / DISARMING IAW MM 52-73-13-05-02, SYSTEM CHECKS GOOD. NO HISTORY 99 DAYS. A/C OK FOR SERVICE.SDR FDEA201510203280Warning Message · false activationREJECTED TAKEOFF BELOW 80 KTS, FOR A MOMENTARY YELLOW HYD LOW PRESSURE ECAM ALERT. ANOTHER SUCCESSFUL TAKEOFF ATTEMPT WAS MADE. SYSTEM OPS NORMAL THROUGHOUT ALL PHASES OF FLIGHT. PERFORMED HYDRAULIC PRESSURE INDICATING FUNCTIONAL TEST PER AMM 29-32-00-05SDR FDEA201510053075Floor Panel · crackedMAIN DECK FLOOR PANEL 232YG HAS CRACK, BETWEEN FRAME 28 - 30, -Y450, -Y953. FABRICATED NEW PANEL 232YG ON T15 1165123 IAW DWG SRZ 25-005 REV L. CLASSIFIED AS MAJOR CAT A REPAIR.SDR FDEA201510053074Floor Panel · damagedMAIN DECK FLOOR PANEL 242EK HAS MISSING INSERTS, BETWEEN FRAME 51 - 54, -Y450, -Y953. FABRICATED NEW PANEL 242EK ON T15 1165124 IAW DWG SRZ 25-005 REV L. CLASSIFIED AS MAJOR CAT A REPAIR.SDR FDEA201510053073Floor Panel · damagedMCD BETWEEN FRAME 47 & 51, BETWEEN -Y450 & -Y953 FLOOR PANEL IS SPONGY & HAS MOVEMENT WHEN STEPPED ON. FABRICATED NEW PANEL 242ZJ ON T15 1165068 IAW DWG SRZ 25-005 REV L. CLASSIFIED AS MAJOR CAT A REPAIR.
Back to N667FE