N667NK
Service difficulty reports · 95
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N667NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N667NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ERKR2026102200887Access Panel · corrodedFUEL TANK ACCESS PANEL 540KB HAS EVIDENCE OF CORROSION ON THE FASTENER HOLES.SDR GTIA2025040738835Door · damagedMODERATE VIBRATION 6 TO 7 STRONG THUMPS IN NOSE AREA. PAX FAS ALSO NOTICED WERE CONCERNED SMELL OF BURNING RUBBER MID CABIN -DURING INSPECTION OF NOSE GEAR FOUND LOOSE HARDWARE ON NLG LEG DOOR-ASSY. R&R HARDWARE ON NLG LEG DOOR ASSEMBLY IAW AMM 32-22-15. PERFOSDR GTIA2025032738822Slide · deployedRH ESCAPE SLIDE FIN 7771MM DEPLOYED. REQUIRES R AN R-R + R RH ESCAPE SLIDE FIN 777144. IAW AMM 25-62-47SDR GTIA2025031038793Seal · faultyAIR WING LEAK R PASSING THROUGH 27K FEET-TIGHTENED CLAMP ON PACK 2 IAW AMM 21-52-41. R&R PERI SEALS ON WING BLEED AIR SYSTEM IAW AMM 36-11-48. OPS CHECK GOOD AT THIS TIMESDR GTIA2025030638787Rib · corrodedCORROSION AROUND FASTENERS AT INNER REAR TOP SKIN, GEAR RIB ATACHMENT AND REAR FALSE SPAR ON RH WING. PERFORMED PERMANENT REPAIR LOC ON RH WING TOP SKIN PANEL 2 - GEAR RIB - 5 TO RIB 4 REAR SPAR AND AFT OF FALSE REAR SPAR IAW EA 57-0011-25 AND A321 SRM 51-21SDR GTIA2025030638786Skin Panel · corrodedCORROSION AROUND FASTENERS AT INNER REAR TOP SKIN, GEAR RIB ATACHMENT AND REAR FALSE SPAR ON RH WING. RAF-01 3577668-01 GENERATED.-PERFORMED PERMANENT REPAIR LOC ON RH WING TOP SKIN PANEL 2 - GEAR RIB - 5 TO RIB 4 REAR SPAR AND AFT OF FALSE REAR SPAR IAW EA 5SDR GTIA2025030638785Skin Panel · corrodedCORROSION ON LH WING TOP SKIN BTW RIB AND RIBS RAF-01 3577669-02 GENERATED.-PERFORMED PERMANENT REPAIR OF LH WING TOP SKIN PANEL 2 BTW RIB 4 TO RIB 5 ALONG REAR SPARK-UPPER SURFACE I.A.W. DOSSIER 81543621 AND EA #57-0013-25. THIS REPAIR IS CATEGORY A.SDR GTI2025F00001Knob · brokenL1 MEGAPHONE VOLUMNE KNOB BROKEN-R/R L1 MEGAPHONE IAW CMM 25-60-01. MOC 70318SDR GTIA2024112538553A/C Pack · odorF/A REPORTED OIL SMELL IN CABIN PERFORMED QRH PRUCEDURE SHUT OFF PACK 2 SMELL WENT AWAY -PREFORMED TSM 05-50-810-831 FOUND AFT TRASH BIN WITH HEAVY ODOR. NO THER ODOR DETECTED PREFORMED LEVEL A DECONTAMINATION IAW AMM 21-00-00-615-802-A. A/C OK FOR SERVICESDR GTIA2024082838341Actuator · fault messageSHUTDOWN ENG1 DUE TO ENG 1 COMPRESSOR VANE ECAM-REF. LOG PAGES 3411279-1,2, 3411281-2, 3411282-1 & 3411283-1 & 2 FOR R&R OF VSV ACT. OPS & LEAK CK & HIGH PWR RUN GOOD AS PER AMM 71-00-00.SDR GTIA2024071938240Megaphone · inoperativeDURING OPS CHK OF MEGAPHONES, BOTH FWD AND AFT FAILED TO TEST. -R/R BOTH FWD AFT MEGAPHONES IAW NKS DRAWING A320-EMER EQUIP-2. BOTH OPS CHK GOOD. NO FURTHER DEFECT NOTED.SDR GTIA2024071238229Megaphone · inoperativeFWD FA MEGAPHONE INOP-REMOVED AND REPLACED FWD FA MEGAPHONE IAW AMM 25-65-51 AND DRAWING # A321 CEO*-EMER EQUIP MOC 70318SDR GTIA2024021037895Computer · warning messageF/CTL FLAP TIP BRK FAULT ECAM AT CRUISE ALT-R/R SFCC (21CV) IAW AMM 27-51-34. OPS CK GOOD AT THIS TIMESDR GTIA2024012637813Slide · unwanted deployINADVERTENT DEPLOYMENT OF L3 SLIDE -R+R L3 OFFWING SLIDE AND INFLATION RESERVOIR IAW AMM 25-62-44 AND 25-62-49SDR GTIA2024011037764Unknown · unknownDURING CRUISE, F/A REPORTED STRONG SMOKY/OILY SMELL IN AFT TO MID CABIN ESPECIALLY AROUND L2/L3 AREA. FWD CABIN AND OCKPIT WERE NOT AFFECTED, SEE AIR QUALITY REPORTING FORM FOR DETAILS -PERFROMED TSM 05-50-00-810-831-A REF. LG PG # 3363966-01 FOR WORKED ACCOMPSDR GTIA2023081937427Unknown · unknownR1 DOOR BOTTLE LOW -SERVICED R1 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER IAW AMM 52-10-00-614-001-A NO DEFECTS NOTEDSDR GTIA2023052537214Slide · damagedREF TASK CARD 256241-07-1 REMOVAL OFFWING RESERVOIR WO # 272202 SLIDE UNRAVLED DURING NREMOVAL-R&R RESERVOIR ASSY IAW AMM 25-62-46 R&R L2 OFFWING SLIDE IAW AMM 25-62-49SDR GTIA2023040637092Flashlight · inoperativeREF MEL 3022398-1 L1 JUMPSEAT FLASHLIGHT INOP-R/R L1 JUMPSEAT FLASHLIGHT IAW AMM 25-65-00. OPS CHECK OK THIS ACTION CLEARS MEL 3022398-1 MOC NOTIFIED DMI LOG UPDATED. PLACARD REMOVEDSDR GTIA2023021336968None · noneR1 DOOR ASSIST BOTTLE REQUIRES SERVICE. REF TC ZL-831-04-1-R.-SERVICED BOTTLE PER AMM 52-10-00.SDR GTIA2022050936410None · leakingL2 DOOR ASSIST ACTUATOR LEAKING-REMOVED AND INSTALLED L2 DOOR ASSIST ACTUATOR IAW AMM 52-22-14SDR GTIA2022041436379None · noneDURING CHECK FOUND L2 DOOR PRESSURE LOW ON ASSISST BOTTLE -SVCD L2 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2022040436362None · noneL2 DOOR ASSIST NEEDS SERVICING-SERVICED L2 DOOR ASSIST IAW AMM 52-10-00SDR GTIA2022031036316None · noneL2 DOOR ASSIST OPEN REQUIRES SERVICING-SERVICED L2 DOOR ASSIST OPEN IAW AMM 52-22-00SDR GTIA2022021436273None · noneAFTER TAKE OFF LANDING GEAR DID NOT GO UP AFTER WE MOVED LG LEVER UP, GOT NUMMEROUS ECAM WARNINGS, RECYCLED THE LANDING GEAR AND IT WENT UP. AT 10,000 RECYCLED AGAIN TO CHECK SAMETHING -REF TSM 32-31-00-810-842 R/R PROXIMITY-SENSOR (25GA). IAW AMM 32-31-73. BISDR GTIA2022020336258None · noneL2 DOOR ASSIST BOTTLE LOW PRESSURE -SVCD L2 DOOR ASSIST BOTTLE TO PROPER PRESSURE IAW AMM 52-22-00SDR GTIA2022013136262None · noneL2 DOOR ASSIST BOTTLE LOW PRESSURE -SVCD L2 DOOR ASSIST BOTTLE TO PROPER PRESSURE IAW AMM 52-22-00SDR GTIA2022010436200None · noneR1 AND L2 DOOR ASSIST BOTTLE PRESSURE LOW-SERVICED R1 AND L2 DOOR ASSIST BOTTLE PRESSURE TO PROPER LEVEL IAW AMM 52-10-00.SDR GTIA2021120236160None · noneL2 EMER EXIT DOOR ASSIST BTL REQUIRES SERVICING.-SVCD L2 EMER EXIT DOOR ASSIST BTL IAW AMM 52-22-00.SDR GTIA2021110136084None · nonePASSENGER/ CREW DOOR R1 AND L2 DOOR ASSIST BOTTLE NEEDS SERVICING.-SERVICED PASSENGER/CREW DOOR R1 AND L2 IAW AMM 52-10-00SDR GTIA2021102536066None · noneFOUND L2 DOOR ASSIST BOTTLE LOW.-SERVICED L2 DOOR ASSIST BOTTLE IAW AMM 52-10-00. NO LEAKS DETECTEDAT THIS MOMENT.SDR GTIA2021100736033None · noneL2 & R1 DOORS ASSIST BOTTLE REQUIRE SERVICING.-SERVICED L2 & R1 DOOR ASSIST BOTTLES IAW AMM 52-10-00.SDR GTIA2021093036018None · noneL2 DOOR ASSIST BOTTLE REQ SERVICE-SERVICED L2 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2021093036015Blower · failedVENT BLOWER FAULT ECAM WITH ASSOSIATED BURNT SMELL ( BLOWER FAN (AVIONICS VENTILATION) VENT AVNCS SYS FAULT NOT DISPLAYED )-R/R FAN BLOWER (20HQ) IAW AMM 21-26-51 OPS CHECK OK NO FAULTS NOTED AT THIS TIME. THIS CLEARS DMI # 2872935-1 MOC NOTIFIED PLACARD REMOVSDR GTIA2021090935979Bottle · low pressureL2 DOOR ASSIST BOTTLE REQUIRES SERVICING -SERVICED L2 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2021083035961Bottle · low pressureL2 DOOR ASSIST BOTTLE REQUIRES SERVICING.-SERVICED L2 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2021082335943Bottle · low pressureL2 DOOR BOTTLE ASSISTANCE LOW -SERVICE L2 DOOR BOTTLE ASSISTANCE TO PROPER LEVEL IAW AMM 52-10-00SDR GTIA2021080935918Bottle · low pressureL2 DOOR ASSIST BOTTLE LOW ON PRESSURE-SERVICED L2 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2021080235901Bottle · low pressureL2 DOOR BOTTLE ASSISTANCE REQUIER SERVICE-SERVICE L2 DOOR BOTTLE ASSISTANCE TO PROPER LEVEL IAW AMM 52-10-00SDR GTIA2021072935898Unknown · odorSOCKS SMELL DURING APPROACH. ISOLATING PACK 2 OFF HELPED DISSIPATE THE ODORS. TURNING PACK 2 OFF AND RUNNING PACK 1 HELPED DISSIPATE THE ODORS.-REF LP 2727034-2 FOR PACK BURNOUT.REPLACED RECIRCULATION FILTERS REF: AMM 21-21-41. PROBABLE SOURCE OF ODOR EVENT: ASDR GTIA2021072235888Bottle · low pressureL2 DOOR ASSIST LOW PRESSURE-SERVICED L2 DOOR ASSIST BTL TO LEVEL IAW AMM 52-10-00.SDR GTIA2021070835855Bottle · low pressureEMERGENCY DOOR L1 ASSIST BOTTLE NEED SERVICING-SERVICED EMERGENCY DOOR L1 ASSIST BOTTEL IAW AMM 52-10-00SDR GTIA2021020835586Bottle · low pressureDURING WEEEKLY FOUND FWD L EMERGENCY EXIT DOOR ASSIST BOTTLE LOW-SERVICED FWD L EMER EXIT DOOR ASSIST BOTTLE IAW AMM 52-10-00 NO LEAKS NOTEDSDR GTIA2021020435582Megaphone · inoperativeFORWARD MEGA PHONE INOP-R+R FWD MEGA PHONE IAW SPIRIT A321 EMERGENCY EQUIPMENT DRAWINGSSDR GTIA2021011135541Bottle · low pressureL2 DOOR ASSIST BOTTLE REQUIRES SERVICING. SERVICED L2 DOOR ASSIST BOTTLE, IAW AMM 52-10-00. LEAK AND OPERATIONS CHECK GOOD.SDR GTIA2021010435531Bottle · low pressureL2 EMERGENCY DOOR EXIT ACCUMULATOR FOR DOOR ASSIST REQUIRES SERVICE. L22 EMERGENCY DOOR EXIT ACCUMULATOR FOR DOOR ASSIST WAS SERVICED, IAW AMM 52-10-00.SDR GTIA2020120735490Bottle · low pressureR1 AND L2 DOORS ASSIST BOTTLE NEED SERVICE. SERVICED R1 AND L2 DOORS ASSIST BOTTLE TO PROPER PRESSURE, IAW AMM 52-10-00.SDR GTIA2020111935451Unknown · odorON DESCENT, AFTER LEVEL OFF AND ENGINE SPOOL UP WE BRIEFLY SMELLED A CHEMICAL OR WET PAINT TYPE SMELL. NO SMELL WAS NOTICED IN CABIN. PERFORMED TSM 05-50-00-810-23-A (TYPE 5) INSPECTED PACK NR 1 FOR CONTAMINATION, IAW AMM 21-51-00. FOUND NO EVIDENCE OF CONTSDR GTIA2020111935442Unknown · odorON DESCENT, AFTER LEVEL OFF AND ENGINE SPOOL UP WE BRIEFLY SMELLED A CHEMICAL OR WET PAINT TYPE SMELL. NO SMELL WAS NOTICED IN CABIN. PERFORMED TSM 05-50-00-810-23-A (TYPE 5) INSPECTED PACK NR 1 FOR CONTAMINATION, IAW AMM 21-51-00. FOUND NO EVIDENCE OF CONTSDR GTIA2020110935436Fan · failedGRINDING NOISE AT CRUISE FH FOLLOWED BY BURNING SMELL VENT EXTRACT FAULT AT GATE. INSTALLED NEW AVIONICS FAN, IAW AMM 21-26-11. OPERATIONS CHECK GOOD. A/C OK FOR SERVICE.SDR GTIA2020091435359Accumulator · low pressureL2 DOOR ASSIST ACCUMULATORS REQUIRES SERVICE. L2 DOOR ASSIST ACCUMULATORS WAS SERVICE, IAW AMM 52-10-00.
Back to N667NK