N667NK
Service difficulty reports · 95
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N667NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N667NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2020080335300Bottle · low pressureL4 DOOR ASSIST ACCUMULATOR PRESSURE LOW -SERVICED L4 DOOR ASSIST ACCUMULATOR IAW AMM 52-10-00.SDR GTIA2020071635262Bottle · low pressureR1 + L2 DOOR ASSIST BTL NEED SERVICING. SERVICED R1 + L2 ASSIST BTL IAW AMM 52-10-00.SDR GTIA2020071335245Megaphone · failedAFT MEGAPHONE DOESENT SOUND EMERGENCY TONE WHEN PIN IS PULLED. R/R MEGAPHONE IAW CMM 25-60-01. OPS CHECKED GOOD.SDR GTIA2020061535201Bottle · low pressureL2 DOOR ASSIST BOTTLE READING ZERO PRESSURE. SERVICED L2 DOOR ASSIST BOTTLE IAW AMM CH 52-22-22.SDR GTIA2020032335120Bottle · low pressureR1 AND L2 DOOR BOTTLE ASISTANCE REQUIRED SERVICE.-SERVICED R1 AND L2 BOTTLE ASSISTANCE TO PROPER LEVEL IAW AMM 52-10-00.SDR GTIA2020030935077Bottle · low pressureSERVICING REQUIRED FOR L2 DOOR ASSIST BOTTLE-SERVICED L2 DOOR ASSIST BOTTLE IAW AMM 52-10-00. OPS AND LEAK CHECK GOODSDR GTIA2020021095000Bottle · low pressureL2 EMERGENCY DOOR ASSIST BOTTLE CHARGE LOW-SERVICED L2 EMERGENCY DOOR ASSIST BOTTLE TO PROPER PRESSURE IAW AMM 52-10-00. LEAK CHECK GOODSDR GTIA2020010634915Unknown · odorMID CABIN FA( SAME DAY, DIFFERENT PERSON) ALSO REPORTED SMELLING A CHEMICAL SMELL DURING TAKE OFF AND DESCENT-ACCOMPLISHED TSM 05-50-00-810-831 FOR CABIN ODOR RAN BOTH ENGINES, PACKS AND APU COULD NOT DUPLICATE ODOR. SUSPECT PASSENGER BODY FRAGARANCESDR GTIA2019122433891Bottle · low pressureR1 AND L2 DOOR ASSIST BOTTLE REQUIRES SERVICING-SERVICED R1 AND L2 DOOR ASSIST BOTTLES IAW AMM 52-10-00SDR GTIA2019112514808Bottle · low pressureR1 DOOR BOTTLE ASSISTANCE REQUIER SERVICE -SERVICE R1 DOOR BOTTLE ASSISTANCE TO PROPER LEVEL IAW AMM 52-10-00SDR GTIA2019112514807Bottle · low pressureL2 DOOR BOTTLE ASSISTANCE REQUIER SERVICE -SERVICE L2 DOOR BOTTLE ASSISTANCE TO PROPER LEVEL IAW AMM 52-10-00SDR GTIA2019100324663Bottle · low pressureL2 DOOR ASSIST BOTTLE REQUIRES SERVICE. SERVICED L2 DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001.SDR GTIA2019082633571Bottle · low pressureL2 DOOR ASSIST ACCUMULATOR LOW. -SERVICED L2 DOOR ASSIST ACCUMULATOR TO PROPER PRESSURE IAW AMM 52-22-00.SDR GTIA201908223564Bottle · low pressureR1 DOOR ASSIST BOTTLE VELOW WEEKLY LIMIT-SVC R1 DOOR ASSIST BOTTLE TO PROPER LEVEL IAW AMM 52-10-00SDR GTIA2019081204547Bottle · low pressureLEFT EMERGENCY DOOR ASSIST BOTTLE CHARGE LOW. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00. LEAK CHECK GOOD.SDR GTIA2019072103497Bottle · low pressureL2 AND R1 DOOR ASSIST BOTTLE PRESSURE IS LOW. SERVICED L2 AND R1 DOOR ASSIST BOTTLES IAW AMM 52-10-00-614-001.SDR GTIA2019070203450Bottle · low pressureFOUND L2 DOOR ASSIST BOTTLE LOW PRESSURE. SERVICED BOTTLE PER AMM 52-10-00 TO NORMAL PRESSURE.SDR GTIA2019052403369Bottle · low pressureL1 EMERGENCY DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED L1 EMER DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2019051803357Assist System · low pressureL2 DOOR ASSIST LOW. L2 DOOR ASSIST SERVICED TO PROPER LEVEL IAW 52-10-00.SDR GTIA2019051803356Assist System · low pressureR1 DOOR ASSIST LOW-SERVICED R1 DOOR ASSIST TO PROPER LEVEL IAW 52-10-00.SDR GTIA2019040853269Bottle · low pressureL2 & R3 DOOR ASSIST BOTTLES ARE LOW-SERVICED L2 AND R3 DOOR ASSIST BOTTLES IAW AMM 52-22-00. LEAK CHECK GOODSDR GTIA2019020703144Bottle · low pressureL2 AND R3 DOOR ASSIT BOTTLE LOW PRESSURE -SERVICED L2 AND R3 DOOR ASSIST TO PROPER PRESSURE IAW AMM 52-10-00SDR GTIA2018122703049Bottle · low pressureL2 AND R3 DOOR ASSIST BOTTLE LOW -SVCD L2 AND R3 DOOR ASSIST BOTTLE IAW AMM 52-22-00SDR GTIA2018121082999Bottle · low pressureL2 AND R3 DOORS ASSIST BOTTLE PRESSURES ARE LOW-SERVICED L2 AND R3 DOOR ASSIST BOTTLES IAW AMM 52-10-00 LEAK CK GOODSDR GTIA2018120602994Bottle · low pressureDURING WEEKLY CHECK FOUND, L2 AND R3 DOOR BOTTLES ARE LOW.-SERVICED L2 AND R3 DOOR BOTTLES WITH N2 IAW AMM 52-10-00. LEAK CHECK GOOD.SDR GTIA2018111962974Bottle · low pressureR1 , R3 , L2 , L4 DOOR ASSIST BOTTLE BELOWLIMIT -SERVICED R1 , R3, L2 & L4 DOOR ASSITBOTTLES IAW AMM 52-10-00. TO PROPER LEVELS. OPS CHECK GOOD.SDR GTIA2018080642787Diaphragm · leakingL2 DOOR WONT HOLD ASSIST BOTTLE PRESSURE. REMOVED & REPLACED THE DOOR ASSIST BOTTLE DIAPHRAGM IAW AMM 52-22-00. OPS & LEAK CHECKED GOOD.SDR GTIA2018072702775Unknown · odorFLT ATTENDANT REPORTED ODOR SMELL IN FWD GALLEY. PERFORMED OPS CHECK OF THE AIR COOLING SYSTEM IAW AMM 21-52-00. NO ODOR NOTED IN FWD GALLEY.SDR GTIA2018021702442A/C Pack · odorAFTER TAKE OFF, A DIRT SOCK MUSTY ODOR WITH THE NR 1 PACK OFF. ODOR DISAIPATED, TRIED THE NR 1 PACK AFTER 5 MINUTES, THE ODOR RETURNED, BURNING EYES, AND HEADACHES REPORTED BY FLIGHT CREW. ODOR REPORTED BY F/A. IAW TSM 05-50-00-810-831-A FOUND THE CSDR GTIA2018012502364Bottle · low pressureL2 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-22-00. NO LEAKS NOTED.SDR GTIA2018011902351Bottle · low pressureFOUND DOOR ASSIST BOTTLE HAD LOW PRESSURE AT THE R1 DOOR. SERVICED THE ASSIST BOTTLE IAW AMM 52-10-00, & 52-22-00SDR GTIA2018010102320Megaphone · inoperativeFA REPORTED THE MEGAPHONE INOPERATIVE. R & R THE MEGAPHONE IAW AMM 25-65-51. OPS CHECKED GOOD.SDR GTIA2017120502271Bottle · low pressureL2 DOOR ASSIST BOTTLE IS LOW. SERVICED L2 DOOR ASSIST BOTTLE TO CORRECT PSI IAW AMM 52-22-00.SDR GTIA2017120502270Bottle · low pressureR3 DOOR ASSIST BOTTLE IS LOW. SERVICED R3 DOOR ASSIST BOTTLE TO CORRECT PSI IAW AMM 52-22-00SDR GTIA2017100502195Bottle · low pressureR1 DOOR ASSIST BOTTLE LOW PRESSURE . SERVICED THE DOOR ASSIST BOTTLE AMM 52-10-00.SDR GTIA2017081002145Knob · missingFWD MEGAPHONE VOLUME KNOB MISSING . REPLACED FWD MEGAPHONE IAW DRAWING NK321F2476EQ REV 6SDR GTIA2017073102131Bottle · low pressureR3 DOOR ASSIST BOTTLE REQUIRES SERVICE. SERVICED R3 DOOR ASSIST BOTTLE TO SERVICABLE LIMITS IAW AMM 52-22-00. LEAK CHECKED GOOD.SDR GTIA2017071902093Bottle · low pressureDURING WEEKLY CHECK, FOUND R3 DOOR ASSIST BOTTLE REQUIRES SERVICING. SERVICED R3 DOOR ASSIST BOTTLE TO SERVICEABLE LIMITS IAW AMM 52-22-00. LEAK CHECKED GOOD.SDR GTIA2017071902092Bottle · low pressureDURING WEEKLY CHECK, FOUND R1 DOOR ASSIST BOTTLE REQUIRES SERVICING.. SERVICED R1 DOOR ASSIST BOTTLE TO SERVICEABLE LIMITS IAW AMM 52-10-00. LEAK CHECKED GOOD.SDR GTIA2017062202004Bottle · low pressureR1 DOOR ASSIST BOTTLE LOW. SERVICED THE BOTTLE IAW AMM 52-22-00. LEAK CHECKED GOOD.SDR GTIA2017032901847Megaphone · defectiveWHILE PERFORMING T/C 256551-01 FOUND SETSCREW STRIP ON FWD MEGAPHONE. R&R FWD MEGAPHONE IAW EMERGENCY EQUIP LAYOUT DRAWING NKS321-2560EQ.SDR GTIA2017011601745Bottle · low pressureR3 DOOR ASSIST BOTTLE REQUIRES SERVICING. SERVICED R3 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2016112901676Bottle · low pressureFOUND R-1 L1 AND R-3 DOOR ASSIST BOTTLES LOW. SERVICED R-1 L1 AND R3 DOOR ASSIST BOTTLES WITH NITROGEN IAW AMM 52-10-00.SDR GTIA2016091101588Bottle · low pressureR3 DOOR ASSIST BOTTLE EMPTY. SERVICED THE ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2016082301576Bottle · low pressureR3 DOOR ASSIST BOTTLE HAS LOW PRESSURE. SERVICED THE R3 DOOR ASSIST BOTTLE IAW AMM 52-10-00
Back to N667NK